Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp. sensor (Optional) -stage fan speed control Dry contact for alarm High efficiency and high reliability Built-in battery rescue function Built-in Engine Start Battery (ESB) output function Protection: Short Circuit / Over Voltage / Over Temperature / Brown-out Withstand G vibration test RS- communication interface Output power OK signal Output Input Protection Function Environment Safety & EMC Others Note Note. MODEL C C C C0 C80 Battery Type Lead Acid / Li-ion / Gel / AGM Standard Boost Charge Voltage.V /.7V (Select by S-) Standard Float Charge Voltage.8V /.V (Select by S-) Main Rated Current A A A 0A 80A Current Range 0 ~ A 0 ~ A 0 ~ A 0 ~ 0A 0 ~ 80A Main Output ESB Output ESB Output Voltage / Current.8V / A.8V / A.8V / A Battery Charging Mode - stage charging capability (IUOU) Single Output Current Limit A A A 0A 0A Voltage Range 90 ~ 6VAC Power Factor (Typ.) PF > 0.9 at full load Frequency Range 7 ~ 6Hz Efficiency (Typ.) at 0VAC 87% 87% 87% 87% 87% AC Current (Typ.) Leakage Current Short Circuit Over Voltage Over Temperature Working Temp. Working Humidity Storage Temp., Humidity Temp. Coefficient Vibration Withstand Voltage Isolation Resistance EMI Conduction & Radiation Harmonic Current EMS Immunity. A / 00VAC.07A / 0VAC For earth < ma / 0VAC -0 ~ 0 C (refer to output load de-rating curve) 0 ~ 90% RH non-condensing -0 ~ +8 C, 0 ~ 90% RH ±0.0% (0 ~ 0 C) 0 ~ 00Hz, G 0min. / cycle period for 60min. each along, Y, Z axes I/P-O/P: VDC, I/P-FG: 768VDC, O/P-FG: 700VDC I/P-O/P: 00M Ohms / 00VDC. A / 00VAC.8A / 0VAC 6. A / 00VAC.8A / 0VAC EN 0; EN 0; EN 60-; EN 0-; EN 0- EN 6000--; EN 6000--; EN60-; EN 6000-6-; EN 6000-6- 8. A / 00VAC.6A / 0VAC Current is reduced to < A continued 0sec., fan will operate 0 seconds then turn off 7.V ±%, Protection type: Shut down output (recovery after resetting AC power on) Charger Over Temperature 00 ± C detected by heat sink Battery Over Temperature ± C (Optional device - COTEK temperature sensor), connect on CN Alarm Signal NC. / NO. Relay contact output ( Please refer to page Alarms Signal & Fan Control ) Power Mode Supply.V Current limit output voltage Temperature Compensation Charging Sleep Mode Note. -0mV / 0. C with COTEK temperature sensor By Remote Controller and S- DIP switch ( Please refer to page ~) Remote Controller Note. Support COTEK Remote Controller CR- setting Function (CN or ) Safety Standards Certified EN 60-, EN 60--9 Protection type: Auto recovery after heat sink temperature goes down to 0 C IEC 6000--,,,, 6, 8, ; ENV 00 Dimension (WxHxD) 8x7x.mm 8x7x.mm 8x7x6.mm x76.x7.mm x76.x.mm Packing.6kg.7kg.9kg.kg.0kg. A / 00VAC.A / 0VAC. All parameters not specially mentioned are measured at 0VAC input, rated load and C of ambient temperature.. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.. Before charging, make sure the battery charger and battery specifications are compatible.. When use sleep mode, please refer to charging current v.s. heat sink temperature de-rating curve.. Optional Remote Controller (CR-).
Cxx Mechanical Specification: Unit : mm[inch] MODEL: C// 7.mm C/ mm C 0mm C/.mm C 6.mm C/.mm C 6.7mm Air Flow 9 6. C STATUS S CN DC OUTPUT TEMP / CN AC INPUT 7mm ESB 8mm C/ STATUS S CN DC OUTPUT TEMP / CN AC INPUT 7mm ESB 8mm
Cxx Unit : mm[inch] MODEL: C0/80 0.mm C0 7.mm C80.mm Air Flow 9 6. C0 mm C80 8mm C0 60.mm C80 6.mm STATUS S CN DC OUTPUT TEMP / CN AC INPUT 76.mm mm
Cxx Charging Mode Setting (S): Status CC/CV Float Notes CC turn to CV voltage Float voltage.v. Without COTEK temperature sensor: No voltage and temperature.7v compensation (0 ). With COTEK temperature sensor: Output voltage changes per.v temperature changes (-0mV/0. ).8V Power Mode (Current limit output voltage).v.v No voltage, current and temperature compensation (Regulated by internal SENSOR) REMOTE Sleep mode / Charger / (Press the button for second to turn off the charger) & Sleep mode / (Once the charger is turned on, press the button for second to activate sleep mode) Limit the maximum fan speed (Output current is regulated by the temperature) Don't limit the maximum fan speed (Output current is regulated by the temperature) : Not applicable ---: Not applicable Charging Status and Indicator: Charging status LED Status Alternation in the charging Status Default setting Bulk- Orange fast Charging voltage >0.V and < float voltage NO Bulk- Orange slow.charging voltage > Float voltage and charging current >= Rating current.charging voltage = CV voltage and charging current < Rating current -- minutes 6 hours Absorption- Orange solid Charging current > 6% of rated current ( ±%) 6 hours Absorption- Green solid Charging current < 6% of rated current (±%) 8 hours Float Green flash LED colour change by the status change.charging voltage >.8V. The voltage goes up to CV voltage to charge the battery once every 88 hours 88 hours 8 minutes Unlimited circle Float to Bulk- -- Charging voltage <.8V 0 sec. Failure Indicator: Failure status LED Status Description Activate Recovery Input or Output Temperature Red solid Red fast Current is reduced to <A,Continued 0 sec., FAN turn on 0 sec then turn off. AC I/P unstable Output FUSE blown Battery over heat ( the indicator available when COTEK temperature sensor connected only) Battery in cold condition(the indicator is available when COTEK temp. sensor is connected) Output <V <8V,>70V Voltage difference >0.V,>0. sec. > <-8 AC Reset, Output>9V >90V,<6V AC Reset < >-0 Charger over heat (Heat Sink) >00 <0 Battery Voltage Red slow Battery over voltage Battery under voltage or output under voltage in CC mode. >7.V <0.V AC Reset, <.7V >0.V Fan Abnormality Red light flash twice Fan abnormality ----- ----- ESB Failure Red light slow ones ESB no output / output short < V & 0 sec. AC Reset
Cxx TEMP/CN 6 : 6 R_VCC GND TEMP BAT- DATA I/O BAT+ R_VCC BAT- NC. BAT- DATA I/O BAT+ ESB Connectors: + - VCC GND TEMP/CN 6 RJ- 6P6C 6 RJ- 6P6C ESB + - Alarms Signal and Fan Control Connectors Pin Definition(CN): Normally Closed Normally Open COM Sleep Mode Control GND CN - SHORT Sleep Mode - OPEN Sleep Mode Charging Curve at Temperature Compensation:.8VDC.VDC.8VDC.VDC.0VDC Volt system : -0mV / 0..VDC -.mv / per cell U Rer 0 In the CV=.V and float =.8V situation. Please follow this rule in other situation.
Cxx Charging curve: Charger Current vs Heat Sink Temperature De-rating Curve: Charging current Sleep mode (On) Sleep mode (Off) 00% 0% Operation area 0% -0 C 0 C 0 C 70 C 00 C Rescue Battery Curve: Output current and heat sink Rating Current.% Rating Current.8V.6V 0V 0V 6