Examples of Electric Drive Solutions and Applied Technologies

Similar documents
Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.

Development of Variable Geometry Turbocharger Contributes to Improvement of Gasoline Engine Fuel Economy

Subsynchronous Shaft Vibration in an Integrally Geared Expander-Compressor due to Vortex Flow in an Expander

Special edition paper

Development of Large-capacity Indirect Hydrogen-cooled Turbine Generator and Latest Technologies Applied to After Sales Service

Development of Two-stage Electric Turbocharging system for Automobiles

Next-generation Inverter Technology for Environmentally Conscious Vehicles

690-V Inverters Equipped with SiC Hybrid Module FRENIC-VG Stack Series

Hybrid Hydraulic Excavator HB335-3/HB365-3

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Hitachi Electric Drive Solutions that Contribute to Global Environment

MHI Integrally Geared Type Compressor for Large Capacity Application and Process Gas Application

Development of Emergency Train Travel Function Provided by Stationary Energy Storage System

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Technology of Estimating Short Circuit Current and Ground Fault for Direct Current Distribution Systems

Power Factor Improvement

Next-generation SCADA and Control Technologies for Large-scale Use of Photovoltaic Generation on Electric Power Grid

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

The 1,400-MW Kii-Channel HVDC System

Innovative Power Supply System for Regenerative Trains

Operating Results of J-series Gas Turbine and Development of JAC

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

The Circuit and Control Technology in the Power Conditioner and Converter for Wind Turbine Systems

Electrical Test of STATCOM Valves

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Tire Uniformity Machine, LIBROTA

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

Integration of Large Wind Farms into Electric Grids

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Newly Developed High Power 2-in-1 IGBT Module

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

Energy Storage for Traction Power Supply Systems

HVDC. TMT&D provides the best and most economical HVDC system.

The cement and minerals industry

DEVELOPMENT AND IMPLEMENTATION OF VFD ACTIVE DAMPING TO SMOOTH TORSIONAL VIBRATIONS ON A GEARED TRAIN

Working Principle of Power Saver as per Manufacture:

Counter Rotating Fan San Ace 92 9CRA type

ELG4125: Flexible AC Transmission Systems (FACTS)

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series

FRENIC-Mega Series of High-performance Multi-function Inverters

Development of the Regenerative Power Compensation Device SANUPS K23A (R Type)

Robust Control Technique for Grid-connected Power Conditioner

CHAPTER 1. Introduction and Literature Review

Technology for Reducing the Environmental Impact of Motors and Improving Their Reliability

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Statcom Operation for Wind Power Generator with Improved Transient Stability

Power Quality and Energy Management

VPP: New Stage in Energy Management Smart Utilization of Self-Generation Facilities with Automated DR System

Application of DSS to Evaluate Performance of Work Equipment of Wheel Loader with Parallel Linkage

Safe, fast HV circuit breaker testing with DualGround technology

E-15 Uninterruptible Power Systems (UPS)

Technical Explanation for Inverters

COMPARISON OF DIFFERENT METHODS FOR EXCITATION OF SYNCHRONOUS MACHINES

Hybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Retrofitting of Mitsubishi Low NOx System

Eastman Chemical Company Motor Analysis Stepping out of the Box

Doubly fed electric machine

Grid Stability Analysis for High Penetration Solar Photovoltaics

Energy Saving Technologies for Elevators

Development of the Single Phase PV Inverter SANUPS P61A

All-SiC Module for Mega-Solar Power Conditioner

Engine Transient Characteristics Simulation Technology using Zero-dimensional Combustion Model

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

TTM-04: The relationship of system efficiency and speed control using VSDs vs. EC motors

Technology that Evolves in Line with Market Changes

Workshop on Grid Integration of Variable Renewable Energy: Part 1

CI-TI Contactors - VLT Frequency Converters

Hybrid Wheel Loaders Incorporating Power Electronics

Lower-Loss Technology

E-15 Uninterruptible Power Systems (UPS)

Dynamic Behavior Analysis of Hydraulic Power Steering Systems

Targeted Application of STATCOM Technology in the Distribution Zone

Research on vibration reduction of multiple parallel gear shafts with ISFD

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Energy Management for Regenerative Brakes on a DC Feeding System

A starting method of ship electric propulsion permanent magnet synchronous motor

GREE Photovoltaic DC Inverter Centrifugal Chiller

VFD Best Practices: Getting the Most from Your VFD Investment

Japan s new motor standards and Top runner Scheme

Torque Measurement Primer

ELECTRICAL POWER and POWER ELECTRONICS

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Table of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1

Core Components for Large-scale PV Generation Systems

Asynchronous Generators with Dynamic Slip Control

INVESTIGATION OF THE IMPACT OF SWITCHING A HEAVILY LOADED TRANSMISSION LINE ON OPERATION OF A POWER PLANT WITH TURBINE-GENERATOR UNITS

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Generators for the age of variable power generation

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Transcription:

Examples of Electric Drive Solutions and Applied Technologies 2 Examples of Electric Drive Solutions and Applied Technologies Atsushi Sugiura Haruo Nemoto Ken Hirata OVERVIEW: Hitachi has worked on specific solutions for the reduction of CO 2 emissions in the oil and gas field by utilizing energy-saving technologies for rotating machinery. In particular, switching existing steam turbine drive equipment to electric drive has achieved a significant reduction in CO 2 emissions. Some implementation-related considerations apply when converting rotating machinery to electric drive, such as how to deal with resonance and higher harmonics. Hitachi has made efforts to meet these challenges, drawing upon its strength in analysis based on prior simulations and verification technologies. INTRODUCTION A number of centrifugal compressors with steam turbine drive, delivered during the 196s, are currently in operation at oil and gas plants in Japan. It is expected that significant energy savings and CO 2 emissions reductions can be achieved by utilizing existing equipment but replacing the steam turbines with drive systems that combine electric motors and inverters. This article outlines specific implementation examples and their supporting simulation technologies in terms of the solution menu stated in another article on the highlight pages, Hitachi Group s Involvement in Oil and Gas Industry. COMPRESSOR SYSTEM RETROFIT The first example is from an oil refinery in Japan and looks at the modification of a centrifugal compressor driven by a steam turbine to use an electric motor and inverter (see Fig. 1). [ Retrofit refers to the addition of new components (equipment) to improve older equipment.] Table 1 shows the major changes from the existing equipment. The benefits of converting to electric drive include: (1)Annual CO 2 reduction of 4 achieved by converting to an electric motor and inverter drive TABLE 1. Changes by Retrofitting These are the major changes to the existing equipment that resulted from the compressor system retrofit. Existing equipment Work classification Retrofitting Centrifugal compressor Steam turbine Boiler equipment Overhaul Removal Partial suspension, proper operation Diversion of existing equipment Change to electric motor, speed-up gear Introduction of inverter drive Before retrofit: 2,38-kW steam turbine Boiler drive Centrifugal compressor After retrofit: 2,43-kW induction motor Speed-up gear drive Centrifugal compressor Fig. 1 Compressor System Retrofit. The compressor system retrofit shown here achieved a 4 reduction in CO 2 emissions. Retrofit means adding new components (equipment) to improve older equipment.

Hitachi Review Vol. 8 (29), No. 1 21 (2)Appropriate operation of boiler (One boiler has become a standby unit.) (3)Reduced operational costs (4)Reduced drive maintenance costs () Improved control capability through the use of the inverter (acceleration and speed can be controlled independently.) Considerations for Conversion to Electric Drive The following issues need to be considered when converting to electric drive. (1)Available space for the installation (2)Explosion-proof type of the electric motor (3) How to deal with pulsating torque (torque ripple) after installation Regarding space availability (1), the platform on which the equipment was to be installed needed to be enlarged because the total length of the electric motor and the speed-up gear was longer than the steam turbine. Since higher harmonics from the inverter may cause instability in the shaft voltages, explosion-proof type (2) was addressed by internal pressurization. Countermeasures for Dealing with Pulsating Torque (Torque Ripple) The problem of pulsating torque described in the section above (3) is caused by higher harmonics in the motor current generating torsional vibrations in the drive shaft. If the frequency of the pulsating torque matches the natural torsional resonance frequency of the overall shaft system, resonance may increase the torsional vibration torque and cause damage to the machinery. To address this problem, Hitachi performed a simulation analysis that covered the machine shaft, electric motor and inverter unit, and developed a resonance control system that prevents excessive shaft torque by monitoring the inverter output voltage and modifying the voltage if pulsating torque is evident in the current waveform. The new control system was used in this project. Verification with Actual Equipment Fig. 2 shows verification data from the actual system. The results of an acceleration test from 6 to show that the equipment operates correctly as there was no particular waveform distortion. Evaluation of Electric Drive Conversion Project Commissioning of the compressor equipment retrofit project to use electric drive went smoothly thanks to a coordinated design that considered the compressor, motor, inverter and control system, as well as by the application of Hitachi s simulation technologies and vibration control technologies to deal with pulsating torque. Hitachi Group manufactures all of this equipment in-house and the success of this project shows that, by utilizing the group s broad-based strengths in areas ranging from control systems to analysis and simulation technology, this approach can be adopted in a wide range of scenarios both in Japan and overseas (see Fig.3). The next section describes an example of Hitachi s simulation technology that models electric drive systems from the drive itself through to the power supply system. HITACHI S SIMULATION TECHNOLOGIES SOLVE PROBLEMS OF OVERALL DRIVE SYSTEM In recent years, there have been an increasing number of systems that use a VSD (variable speed drive) to drive compressors and fan pumps for energy Speed bit shift 32% div. 32% 6 1 s 1 s 1 Primary voltage FB 1 bit shift 32% div. 32% 3 Fig. 2 Data from Actual Machine after Retrofitting. The results of testing acceleration from 6 to verify that the equipment worked normally and with no particular waveform distortion. Exciting current FB bit shift 2% div. Torque current FB bit shift 2% div. FB: feed back 2% 2% 7

Examples of Electric Drive Solutions and Applied Technologies 22 Solutions using Hitachi drive system Compressor shaft resonance Compressor Small power fluctuation system Issue Resonance in generation system Harmonic current Drive system solution Stability analysis of system Multi-winding transformer (no harmonic filter) Drive Resonance in compressor shaft Control to reduce torsional vibration Harmonic voltage Multi-level inverter Generation system resonance Analysis tools: Hitachi real-time simulator, etc. Generator Gas turbine Hitachi has the capability, experience, and technologies to supply a total compressor drive system from the power system through to the motor drive. Fig. 3 Solutions Using Hitachi Drive System Problems and solutions for both power side and drive side in drive system are shown. and power saving. As stated in the previous section, the VSD systems are prone to drive shaft damage caused by excessive torsional vibration torque in the shaft if the low-level pulsating torque generated by the VSD happens to match the mechanical resonance frequency of the drive shaft. Other problems include excessive distortion of the incoming voltage and instability in the power supply system caused by the interaction between the higher harmonic currents generated by the VSD and the power supply impedance. Therefore, the design needs to consider the total system to ensure the stability of all system components including the power supply, drive and load. The following section details the simulation technologies used to solve this problem. Shaft Resonance Analysis Technology As shown in Fig. 4, shaft torsional vibration means torsional resonance in the shaft generated when the frequency of the pulsating torque generated by the VSD or rotating machinery matches the mechanical resonance frequency of the drive shaft. Analyzing the shaft torsional vibration requires a lengthy analysis of the stability under acceleration and deceleration and multiple simulations where different operating speeds and load conditions are tested. However, it is difficult to conduct these analyses with VFD Torque pulsation frequency = VFD: variable frequency drive Shaft resonance frequency Rotating machinery Compressor, fan Damage to machine Need to use simulation analysis to avoid damage Fig. 4 Shaft Torsional Vibration. Shaft torsional vibration is generated under the condition that the frequency of the pulsating torque created by the VSD (variable speed drive) or rotating machinery matches the mechanical resonance frequency of the drive shaft. conventional simulators that have a long calculation time. In order to solve this problem, Hitachi Group uses real-time simulation technology. The real-time simulator performs simulation calculations in real time. Fig. shows the structures of a real-time simulator and a conventional simulator. Although conventional simulators implement models of the speed control circuit, converter, and load internally, the calculation time is tens or hundreds of

Hitachi Review Vol. 8 (29), No. 1 23 times longer than real time because the simulations require the use of small calculation steps. In contrast, a real-time simulator performs Traditional simulation Simulator (numerical model) control Data Real-time simulation circuit Control board Simulator (numerical model) Electrical signals circuit control Load Load Fig. Difference in Structure of Conventional Simulation and Real-time Simulation. The calculation time for real-time simulations is much faster than conventional simulations. simulations in real time using the actual VSD rather than a simulation model of the speed controller and then links this with the simulation models of the converter and other parts of the system that run in the computer. For this reason, the calculation time takes the same time as the analysis time (real-time operation) and means that all the necessary patterns can be simulated. In addition, since the actual control device is used, errors associated with a simulated model of the control system do not occur. Therefore, use of realtime simulation allows simulation of more analysis conditions than ever with greater accuracy, and so can be used to prevent or solve problems proactively. Fig. 6 shows simulation calculation results and measurement results from actual machine operation. Supply System Analysis Technology In a power supply system, the inductance in components such as power lines and transformers and Analysis of acceleration and slowdown operation Real-time simulator Actual machine Speed ref. s s Speed FB Fig. 6 Comparison of Results from Simulation and Actual Measurement. The graphs show the results from the simulation and from measurement of actual machine operation. Torque current FB Excitation current FB Electrical power plant Exciter Exciter transformer Boiler Turbine Generator Main transformer Axis torsional analysis swing analysis Stability analysis of system Phase adjuster transformer Cable Overvoltage/surge analysis Large-scale cable system line system flow analysis P, Q control Voltage control Converter Phase modifier Harmonic distortion analysis Axis torsional analysis Compressor Oil and gas plant STATCOM Voltage fluctuation suppression control Factory STATCOM: static synchronous compensator Fig. 7 Schematic Diagram of Transmission System. There is various phenomenon in the transmission system. The power supply system has a number of elements that need to be considered and this requires a complicated analysis model.

Examples of Electric Drive Solutions and Applied Technologies 24 the capacitance of components such as static capacitors, higher harmonics filters, and series capacitors can form a resonance circuit. In the case of parallel resonance of inductance and capacitance, equipment connected to the power supply system may be adversely affected by the distortion of the incoming voltage that results when this resonance frequency matches the frequency of higher harmonics output by the VFD (variable frequency drive). In the case of series resonance of inductance and capacitance, on the other hand, problems such as shaft damage and life shortening may be caused by shaft torsional resonance in generator systems if the resonance frequency is close to the shaft torsional resonance frequency of the generator and its power source. In addition, shaft torsional resonance in the generator system requires caution because it is known that, depending on system conditions, the resonance may be enhanced by interaction between power conversion devices such as VSDs and the generator system. Furthermore, the incoming voltage may become unstable due to interference between load control in the VSD and the voltage control in the generator. For this reason, it is necessary to verify the system stability with a combined simulation of the VSD and power supply system. As shown in Fig. 7, however, the power supply system has a number of elements that need to be considered, such as the load from other equipment and stray capacitance, and may require a complicated analysis model to cover all the elements depending on the phenomenon to be analyzed. In terms of analysis time, the analyzed time domain varies significantly, ranging from hundreds of microseconds when analyzing switching surges in the VSD to the order of seconds when analyzing the stability between the generator and VSD. As stated above, the required model size and the TABLE 2. Types and Characteristics of Simulation Tools The table lists the types of simulation tools and their characteristics. Category Digital program (Effective value analysis) Digital program (Instantaneous value analysis) Analog simulator Digital simulator Features Flow analysis, steady analysis of frequency analysis Transient phenomenon analysis for electric phenomena (large-scale analysis) Inrush current analysis for surges or transformers Analysis based on the VED waveform (small/medium-scale analysis) Performs analysis under conditions close to actual phenomenon (smaller-scale analysis). Analysis utilizing external equipment (small-scale analysis) Hitachi tools TSAP VSAP SHAFTOR HARMO Factory simulator Commercial tools PSS/E ETAP PSCAD/ EMTDC MATLAB HYPERSIM RTDS Fig. 8 Results from Generator Shaft Torsion Analysis. The figure shows results from a shaft torsion analysis of the generator based on simulations of a load disturbance (system failure) in a system where power lines have series capacitance. Thermal power station Boiler Transformer for excitation Exciter Breaker Modeling of turbine to generator HP Generator Turbine Main transformer K HL D HL LP K LG D LG GEN K GE D GE Disturbance line Spring EXC Damper D H D L D G D E Results from analysis of torque in each shaft (example) MN-M 1 Torque 1 EXC GEN 1 1 2 2 1 MN-M 1 1 1 1 2 2 MN-M 1 1.6 MN-M 3 3 4 4 Time (ms) 1.73 MN-M Torque 2 GEN LP 8.16 MN-M Time (ms) Torque 3 LP HP 1 1 2 2 1 Time (ms) 3 3 4 4 1.22 MN-M 2.4 MN-M 3 3 4 4 4.93 MN-M HP: high-pressure turbine D H : high-pressure turbine damping resistor K HL : high-pressure shaft rigidity modulus D HL : shaft damping resistor between highpressure and low-pressure turbine LP: low-pressure turbine D L : low-pressure turbine damping resistor K LG : high-pressure shaft rigidity modulus D LG : shaft damping resistor between lowpressure turbine and generator GEN: generator D G : generator damping resistor K GE : high-pressure shaft rigidity modulus D GE : shaft damping resistor between generator and exciter EXC: exciter D E : exciter damping resistor MN-M: Mega Nm

Hitachi Review Vol. 8 (29), No. 1 2 time domain vary greatly depending on the phenomenon being analyzed but there is no common simulation tool that can handle all the phenomena collectively. Therefore, it is necessary to perform analyses and reviews by selecting different simulation tools for each target phenomenon. Table 2 lists the characteristics of the major simulation tools used by Hitachi Group. Hitachi has technology to appropriately select and utilize all these simulation tools according to the analysis target s size, phenomenon, time scale, and customer demand. In addition, as an example of this simulation analysis, Fig. 8 shows results from a shaft torsion analysis of a generator when a load disturbance (system failure) is caused in a system where power lines have a series capacitance. Future Efforts In this chapter, the simulation analysis technologies owned by Hitachi Group were discussed. For energy and power saving, rotating machinery that uses VSD for applications such as compressors and fans is likely to become even more common. Hitachi Group will utilize simulation analysis technologies to contribute to preventing and solving problems caused by the application of VSD. CONCLUSIONS Specific examples of electric drive solutions and applied simulation technologies were described in this article. The scope for saving energy through the use of inverter drives is not limited to oil and gas plants and significant benefits can also expected in other air and fluid powered equipment such as fans, pumps, and blowers. Hitachi Group will improve the reliability of its overall drive products particularly in the field of rotating machinery as stated above, and will take a systematic approach to the global roll out of solutions for energy saving and CO 2 emissions reduction in oil and gas plants. ABOUT THE AUTHORS Atsushi Sugiura Joined Hitachi, Ltd. in 1991, and now works at the Overseas Business Promotion Office, the Industrial Electric & Machine Systems Division, the Public & Industrial Systems Division, the Industrial Systems. He is currently engaged in the planning and sales promotion of replacing mechanical drives with electric motor and inverter drives. Haruo Nemoto Joined Hitachi, Ltd. in 1992, and now works at the Drive System Center, the Electrical Control Systems Division, the Information & Control Systems Division, the Information & Telecommunication Systems. He is currently engaged in the development and design of industrial inverters. Ken Hirata Joined Hitachi, Ltd. in 1999, and now works at the Energy and Environmental Solutions Center, the Projects Administration Division, the Total Solution Division. He is currently engaged in the planning and promotion of energy conservation solution business for oil and gas industries.