C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Similar documents
Troubleshooting Guide for N1225-1/N1237-1/N Alternators

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

N1233 Series Troubleshooting Guide for N Alternator

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

600 Series Troubleshooting Guide for C651 and C654 Alternators

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

500 Series Troubleshooting Guide for C520 Alternators

N1387 Series Troubleshooting Guide for N Alternators

N1240/N1243 Series Troubleshooting Guide for N1240-3/N Alternators

700 Series Troubleshooting Guide for C711/C712 Alternators

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Troubleshooting Guide

Troubleshooting Guide

THE ALT AL ERNA RN T A OR

A/C Generator Systems

Batteries, Alternators, and Chargers

Table No. 1 provides a means of identifying the various alternator systems. Note: All output figures are rated at 3600 RPM. TABLE NO.

ELECTRICAL. Contents - Wiring Diagrams

ELECTRICAL. CDTA Technical Training Center

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation

ST Charger. Industrial Battery Charger

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

24-00 ELECTRICAL POWER


Troubleshooting Guide

ADVANCED PID TROUBLESHOOTING



Phase 1 Workshop Home Study Guide

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

TROUBLESHOOTING GENERATOR UNITS

Battery Operation. Battery Construction. Battery State Of Charge. Battery Load Test. Battery Rating Systems 2/14/12

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME

NOTE: SPECIFICATION TABLES BEGIN ON PAGE 41 OF THIS SECTION.

Electrical Systems. Introduction

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION. Batteries Battery connections

1984 Jeep CJ7. IGNITION SYSTEM - SOLID STATE' 'Distributors & Ignition Systems MOTORCRAFT SOLID STATE IGNITION (SSI)

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

User s Manual. Automatic Switch-Mode Battery Charger

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

ELECTRICAL / GENERAL INFORMATION

1. SPECIFICATION

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Table of Contents P E A R S O N C U S T O M L I B R A R Y. 1. Introduction to Hybrid Electric Vehicles James D. Halderman

ELECTRICAL TABLE OF CONTENTS

DIAGNOSIS AND TESTING

Battery, Mounting and Cables - Battery and Cables Description and Operation

BASIC DIAGNOSTIC PROCEDURES

MODEL No s: PP3, PP3K

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

SECTION 1E ENGINE ELECTRICAL

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

2003 Explorer/Mountaineer Workshop Manual

STANDARD AND GROUND SWITCHED APPLICATIONS

2000 F-150 Workshop Manual

J1 Plug Pin Identification


Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

MCC Automatic Start-Stop Microcomputer Charger Control

Welcome VA School Bus Technicians From

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

STARTING & CHARGING SYSTEM

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

GRD502-B Flow Chart 02/05/09

Model: SE-4020-CA Automatic Battery Charger

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Modulating Furnace Information. Warning on Meter Setting - Read First!

WARRANTY WILL BE VOID If These Steps are Not Performed Before Installing The Control STEPS TO PERFORM BEFORE CONTROL INSTALLATION

1. SPECIFICATION Typ. HPS EPS Capacity 120 A 140 A. 76/140 A at 1,800/6,500 rpm. 70/120 A at 1,800/6,500 rpm. Normal output.


2002 Ford Explorer STARTING & CHARGING SYSTEMS' 'Generators & Regulators - Explorer & Mountaineer STARTING & CHARGING SYSTEMS

F - BASIC TESTING Toyota Celica INTRODUCTION PRELIMINARY INSPECTION & ADJUSTMENTS VISUAL INSPECTION MECHANICAL INSPECTION

DIAGNOSIS AND TESTING Procedure revision date: 06/21/2000

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

1999 Toyota RAV ACCESSORIES & EQUIPMENT Cruise Control Systems - RAV4

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

ALTERNATOR - HITACHI

AC CONVERTER / BATTERY CHARGER

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Electric Motor Controls BOMA Pre-Quiz

Alternator, Leece-Neville 15.00

PowerLevel s e r i e s

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

STARTING & CHARGING SYSTEM SECTIONSC CONTENTS IDX

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Troubleshooting Manual

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

ANTI-LOCK BRAKE SYSTEM

Transcription:

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide Hazard Definitions These terms are used to bring attention to presence of hazard(s) of various risk levels or to important information concerning product life. Indicates presence of hazard(s) that CAUTION will or can cause minor personal injury or property damage. NOTICE Table of Contents Indicates special instructions on installation, operation or maintenance that are important but not related to personal injury hazards. Section A: Wiring Diagrams... 2 3 Section B: Basic Troubleshooting...4 Section C: Advanced Troubleshooting... 5 10 Battery Conditions Until temperatures of electrical NOTICE system components stabilize, these conditions may be observed during cold-start voltage tests. Maintenance/Low Maintenance Battery Immediately after engine starts, system volts are lower than regulator setpoint, amps are medium. 3 5 minutes into charge cycle, system volts increase, amps decrease. 5 10 minutes into charge cycle, system volts increase to, or near, regulator setpoint and amps decrease to a minimum. Low maintenance battery has same characteristics with slightly longer recharge times. Maintenance-free Battery Immediately after engine starts, system volts are lower than regulator setpoint, low charging amps. Once charge cycle begins, low volts and low amps are still present. After alternator energizes, voltage will increase several tenths. Amps will increase gradually, then quickly, to medium to high amps. Finally, volts will increase to setpoint and amps will decrease. The time it takes to reach optimum voltage and amperage will vary with engine speed, load, and ambient temperature. High-cycle Maintenance-free Battery These batteries respond better than standard maintenance-free. Charge acceptance of these batteries may display characteristics similar to maintenance batteries. AGM (Absorbed Glass Mat) Maintenance-free Battery These dry-cell batteries respond better than standard maintenance-free. If battery state of charge drops to 75% or less, batteries should be recharged to 95% or higher separately from the engine s charging system to avoid damaging charging system components and to provide best overall performance. Charge acceptance of these batteries may display characteristics similar to maintenance batteries. Battery Charge Volt and Amp Values Volt and amp levels fluctuate depending on the battery state of charge. If batteries are in a state of discharge as after extended cranking time to start the engine system volts will measure lower than the regulator setpoint after the engine is restarted and system amps will measure higher. This is a normal condition for the charging system; the greater the battery discharge level, the lower the system volts and the higher the system amps. The volt and amp readings will change as batteries recover and become fully charged: system volts will increase to regulator setpoint and system amps will decrease to low level (depending on other loads). Low Amps: Minimum or lowest charging system amp value required to maintain battery state of charge, obtained when testing the charging system with a fully charged battery and no other loads applied. This value will vary with battery type. Medium Amps: System amps value which can cause the battery temperature to rise above adequate charging temperature within 4-8 hours of charge time. To prevent battery damage, the charge amps should be reduced when battery temperature rises. Check battery manufacturer s recommendations for proper charge amp rates. High Amps: System amps value which can cause the battery temperature to rise above adequate charging temperature within 2-3 hours of charge time. To prevent battery damage, the charge amps should be reduced when battery temperature rises. Check battery manufacturer s recommendations for proper charge amp rates. Battery Voltage: Steady-state voltage value as measured with battery in open circuit with no battery load. This value relates to battery state of charge. Charge Voltage: Voltage value obtained when the charging system is operating. This value will be higher than battery voltage and must never exceed the regulator voltage setpoint. B+ Voltage: Voltage value obtained when measuring voltage at battery positive terminal or alternator B+ terminal. Surface Charge: Higher than normal battery voltage occurring when the battery is disconnected from battery charger. The surface charge must be removed to determine true battery voltage and state of charge. Significant Magnetism: Change in strength or intensity of a magnetic field present in alternator rotor shaft when the field coil is energized. The magnetic field strength when the field coil is energized should feel stronger than when the field is not energized. Voltage Droop or Sag: rmal condition occurring when the load demand on alternator is greater than rated alternator output at given rotor shaft RPM. Page 1

Section A: Wiring Diagrams CEN N1601, N1602, N1603, N1604 Alternator and Regulator Description and Operation The alternators listed below are self-rectifying. All windings and current-transmitting components are nonmoving, so there are no brushes or slip rings to wear out. Energize switch activates regulator. Field coil is then energized. N1601 28 V 400 A N1602 28 V 400 A with optional 28 V/ 14 V (50 A maximum on 14 V) N1603 28 V 450 A N1604 28 V 400 A N3107 regulator used on some N1601, N1603, and N1604 alternators maintains alternator output voltage at regulated setting as vehicle electrical loads are switched on and off. Alternator output current is selflimiting and will not exceed rated capacity of alternator. The regulator has: an AC terminal to provide optional AC voltage output tap. overvoltage cutout (OVCO). Regulators with OVCO (overvoltage cutout) will trip at vehicle electrical system voltages above 32 volts that exist longer than 3 seconds. OVCO feature detects high voltage and reacts by signaling relay in field control circuit to open. This turns off alternator. Restarting engine resets OVCO circuit. The following regulators receive energize signal after engine is running: N3118 used on some N1602 alternators N3211 used on some N1601 and N1603 alternators N3223 used on some N1602 alternators N3236 used on some N1604 alternators N3237 used on some N1602 and N1603 alternators N3245 used on some N1602 and N1603 alternators Regulator monitors alternator rotation and provides field current only when it detects alternator shaft rotating at suitable speed. After regulator detects alternator rotation, it gradually applies field current, preventing an abrupt mechanical load on accessory drive system. The soft start may take up to 10 seconds at full electrical load. These regulators: are negative temperature compensated. Setpoints are 28.0 ± 0.2 V (and on N3118 and N3223, 14.0 ± 0.2 V. See below.) at 75F. N3237 and N3245 regulators are negative temperature compensated according to switch-selected battery type. Customer selects position per application. provide overvoltage cutout (OVCO). Regulator will trip OVCO when system voltage rises above 32 V in a 28 V system (16 V in a 14 V system) for longer than 3 seconds. OVCO feature detects high voltage and signals the field circuit to open, turning off alternator. Restarting engine resets OVCO circuit. maintain alternator output voltage at regulated settings as vehicle electrical loads are switched on and off. N3118 and N3223 regulators can be used in single 28 V or dual voltage applications. The regulators: allow single-voltage operation (28 V only). 14 V single voltage application is not available with these regulators. provide optional 28 V/14 V output only from the regulator when phase cable from alternator is connected to regulator. Page 2

Section A: Wiring Diagrams (CONT D) B+ connections on alternator Both positive terminals must be connected together at battery positive potential, using interconnect cable and cable of suitable size as part of vehicle cabling, when alternator is installed in vehicle and during operation. Positive cables from vehicle Interconnect cable 14V B+ terminal (N3118 and N3223 only) IGN terminal AC terminal Case ground: N1601, N1603 Isolated ground: N1604 Figure 3 N1601-1 thru -4, N1603-1/-2, and N1604-1/-2 Wiring Diagram B connections on alternator Both B terminals must be connected to the vehicle s common ground, using interconnect cable and cable of suitable size as part of vehicle cabling, when alternator is installed in vehicle and during operation. Figure 1 N1601, N1602, and N1603 Alternator and Regulator Terminals B+ connections on alternator Both positive terminals must be connected together at battery positive potential, using interconnect cable and cable of suitable size as part of vehicle cabling, when alternator is installed in vehicle and during operation. N3223 only J1939 connector Positive cables from vehicle Interconnect cable Figure 4 N1602-1, -2, -4, -5, -6 Wiring Diagram IGN terminal AC terminal B connections on alternator Both B terminals must be connected to the vehicle s common ground, using interconnect cable and cable of suitable size as part of vehicle cabling, when alternator is installed in vehicle and during operation. Figure 2 N1604 Alternator and Regulator Terminals Figure 5 N1602-3/-7 and N1603-3 Wiring Diagram Page 3

Section B: Basic Troubleshooting Tools and Equipment for Job Digital Multimeter (DMM) Ammeter (digital, inductive) Jumper wires Identification Record List the following for proper troubleshooting: Alternator model number Regulator model number Setpoint listed on regulator Preliminary Check-out Check symptoms in Table 1 and correct if necessary. SYMPTOM Low Voltage Output High Voltage Output 28 V Output 14 V Output TABLE 1 System Conditions ACTION Check: loose drive belt; low battery state of charge. Check: current load on system is greater than alternator can produce. Check: defective wiring or poor ground path; low regulator setpoint. Check: defective alternator or regulator. Check: wrong regulator. Check: high regulator setpoint. Check: defective regulator. Check: alternator. Check: broken drive belt. Check: battery voltage at alternator output terminal. Check: defective alternator or regulator. Go to Chart 2, page 7. Basic Troubleshooting 1. Inspect charging system components for damage Check connections at B cables, B+ cables, B+ interconnect cable, B interconnect cable, and alternator-to-regulator harness. Repair or replace any damaged component before troubleshooting. 2. Inspect all vehicle battery connections Connections must be clean and tight. 3. Determine battery voltage and state of charge If batteries are discharged, recharge or replace batteries as necessary. Electrical system cannot be properly tested unless batteries are charged 95% or higher. In addition, open circuit voltages must be within ± 0.2 V. 4. Connect meters to alternator Connect red lead of DMM to alternator anti-drive end B+ terminal and black lead to alternator anti-drive end B terminal. Clamp inductive ammeter on anti-drive end B+ cable. 5. Operate vehicle Observe charge voltage at batteries with engine running (nom. 27-28 V or 13.5-14.0 V). If charge voltage is above CAUTION 32 V for 28 V system or 16 V for 14 V system, immediately shut down system. Electrical system damage may occur if charging system is allowed to operate at excessive voltage. Go to Table 1 at left. If voltage is at or below regulator setpoint, let charging system operate for several minutes to normalize operating temperature. 6. Observe charge volts and amps Charge voltage should increase and charge amps should decrease. If charge voltage does not increase within ten minutes, continue to next step. 7. Batteries are considered fully charged if charge voltage is at regulator setpoint and charge amps remain at lowest value for 10 minutes. 8. If charging system is not performing properly, go to: N1601, N1602, N1603 Chart 1 on page 6 N1604 Chart 4 on page 9 Page 4

Section C: Advanced Troubleshooting Advanced Troubleshooting Shut down vehicle and restart engine. If alternator functions normally after restart, a no output condition was normal response of voltage regulator to overvoltage condition. Inspect condition of electrical system, including loose battery cables, both positive and negative. If battery disconnects from system, it could cause overvoltage condition in electrical system, causing OVCO circuit to trip. If you have reset alternator once, and electrical system returns to normal charge voltage condition, there may have been a one time, overvoltage spike that caused OVCO circuit to trip. N3223 only: If OVCO circuit repeats cutout a second time in short succession and shuts off alternator field circuit, try third restart. If OVCO circuit repeats cutout a third time, check color of LED while engine is running and go to Chart 3a or 3b, page 8. Other regulators: If OVCO circuit repeats cutout a second time in short succession and shuts off alternator F circuit, try third restart. If OVCO circuit repeats cutout, go to Chart 3 on page 8; or for N1604, go to chart 5 on page 10. N3223 Regulator DESCRIPTION AND OPERATION N3223 regulator with OVCO is attached directly to the outside of alternator. Regulator setpoint has flat temperature compensation. Voltage setpoint is 28.0 ±1.0 V and 14.0 ±0.5. Main diagnostic feature of regulators consists of two tricolored (red, amber, green) LEDs located on the side of the regulator. One LED indicates 28 V system performance, the other LED indicates 14 V system performance. The two LEDs work independently of each other. See Table 2 for diagnostic features and LED explanations. OVCO (overvoltage cutout) operation: 14 V side trips at voltage higher than regulator setpoint that exists longer than 3 seconds of reading voltage above 16 V. OVCO feature detects overvoltage and reacts by disabling the alternator field circuit. This turns off alternator (14 V LED is steady RED light). OVCO circuit will reset automatically when: restarting engine OR system voltage falls below 11 V. 28 V side trips at voltage higher than regulator setpoint that exists longer than 3 seconds of reading voltage above 32 V. OVCO feature detects overvoltage and reacts by disabling the alternator field circuit. This turns off alternator (28 V LED is steady RED light). OVCO circuit will reset automatically when: restarting engine OR system voltage falls below 22 V. TABLE 2 N3223 Regulator LED Operation Modes LED COLOR FLASHING Amber Red STEADY Green Amber STATUS AC/rotation. See Chart 1 on page 6 for 28 V systems, Chart 2 on page 7 for 14 V systems. Alternator is shut down and is not producing power for either voltage. 28 V side trips after 3 seconds of reading voltage above 32 V. 14 V side trips after 3 seconds of reading voltage above 16 V. Regulator remains in this mode until reset by restarting engine or if system voltage drops below 22 V or 11 V, respectively. See Chart 3a or 3b on page 8. Respective system voltage is at regulated setting and operating under control. Respective system voltage is below regulated setting. Alternator is not producing power or circuit is overloaded. See Chart 1 on page 6 for 28 V systems, Chart 2 on page 7 for 14 V systems. Page 5

Section C: Advanced Troubleshooting (CONT D) Chart 1 N3107, N3118, N3211, N3223, N3237, N3245 28V Alternator Output Test Charging Circuit (N1604: start with Chart 4 on page 9) STATIC TEST KEY ON, ENGINE OFF Shut down vehicle and restart engine. Does alternator function normally after restart? Regulator responded to overvoltage condition. Go to Chart 3 on page 8 to troubleshoot OVCO. Shut off engine. With key off, engine off: Test for battery voltage at alternator 28 V B+ terminal. Does battery voltage exist? Repair vehicle ignition circuit wiring as necessary. Continue test. With key on, engine running: Test for battery voltage between IGN terminal on regulator and alternator B terminal. Does 28 V battery voltage exist? Repair vehicle ignition circuit wiring as necessary. Continue test. With key off, engine off: Remove alternator-to-regulator 4-pin harness from regulator. Test for battery voltage across sockets D and C in harness plug. Does 28 V battery voltage exist? With DMM, check resistance across field coil. Connect red lead of DMM to socket A in alternator-to-regulator harness plug. Connect black lead to B+ terminal on alternator. Does meter show 1.0 ± 0.2 ohms? Connect jumper wire from socket A in regulator harness plug to B terminal on alternator. Spark will occur. Touch steel tool to shaft to detect significant magnetism. Is shaft magnetized? Test phase signal into regulator (AC). Set meter to diode tester: Connect red lead of DMM to socket C of regulator harness and black lead to socket B. Meter should show voltage drop value. Then reverse meter lead connections. Meter should show OL (blocking). Regulator is defective. SOCKET CONNECTIONS A F B Phase Signal AC C B D 28 V B+ Figure 5 Alternator-to-Regulator 4-Socket Harness Plug Page 6

Section C: Advanced Troubleshooting (CONT D) Chart 2 N3118 and N3223 only 14 V Alternator Output Test Charging Circuit Shut off engine. With key off, engine off: Test for battery voltage of 14 V output terminal on regulator. Does +14 V battery voltage exist? Repair vehicle wiring as necessary. Set DMM to diode tester. Connect red lead of DMM to socket C of regulator harness plug and black lead to each phase pin in phase harness plug. Meter should show voltage drop value. Then reverse meter lead connections. Meter should show OL (blocking). Regulator is defective. SOCKET CONNECTIONS A F B Phase Signal AC C B D 28 V B+ Figure 6 Alternator-to-Regulator 4-Socket Harness Plug PIN CONNECTIONS A Phase P1 B Phase P2 C Phase P3 Figure 7 Phase Connection 3-Pin Harness Plug Page 7

Section C: Advanced Troubleshooting (CONT D) Chart 3 N3107, N3118, N3211, N3223, N3237, N3245 OVCO Trip Determine 28 V or 14 V (LEDs on N3223 will determine affected output) With meter red lead on 28 V B+ at battery and black lead on chassis ground, start engine. Watch meter dial: Does meter read charge voltage above 29 V? 28 V side tripped OVCO circuit. Go to Chart 3b. 14 V side tripped OVCO circuit. Go to Chart 3a. Chart 3a N3118, N3223 14 V Alternator Output Test OVCO Circuit (14 V LED on N3223 steady RED) Unplug alternator-to-regulator 4-socket harness from regulator. At receptacle on regulator, connect red lead from DMM to socket C. Connect black lead to B terminal. Does resistance read OL (out of limits)? Replace regulator with known good regulator. Run engine. Does OVCO trip? Alternator is defective. Original regulator is defective. Chart 3b N3107, N3118, N3211, N3223, N3237, N3245 28 V Alternator Output Test OVCO Circuit (28V LED on N3223 steady RED) Unplug alternator-to-regulator 4-socket harness from regulator. Connect red lead from DMM to socket A in plug. Connect black lead to socket D in plug. Does resistance read 1.0 ± 0.2 ohms? With red lead from DMM connected to socket A in plug, connect black lead to B terminal. Does resistance read OL (out of limits)? Replace existing regulator with known good regulator. Run engine. Does OVCO trip? Original regulator is defective. SOCKET CONNECTIONS A F B Phase Signal AC C B D 28 V B+ Figure 8 Alternator-to-Regulator 4-Socket Harness Plug Page 8

Section C: Advanced Troubleshooting (CONT D) Chart 4 N1604-all models Output Test for battery voltage across and diagonally between both alternator B+ terminals and alternator B- terminals. Does battery voltage exist? Repair vehicle wiring as necessary. Continue test. Install a jumper from anti-drive end B+ terminal on alternator to IGN terminal on regulator. Touch shaft with steel tool to detect significant magnetism. Is shaft magnetized? Repair vehicle circuit to IGN terminal. Vehicle charging circuit test is complete. Unplug alternator-to-regulator wiring harness. Install a jumper from socket A in harness plug to anti-drive end B terminal on alternator. Touch shaft with steel tool to detect significant magnetism. Is shaft magnetized? Connect DMM across socket D and socket C in harness plug. Does battery voltage exist? Using diode tester, attach red lead to alternator anti-drive end B terminal and black lead to socket B in harness. Continuity should exist. Reverse leads. continuity should exist. Regulator is defective. SOCKET CONNECTIONS Pin A F Pin B AC Terminal Pin C B Pin D B+ Figure 9 Alternator-to-Regulator Harness Plug Page 9

Section C: Advanced Troubleshooting (CONT D) Chart 5 N1604-all models Alternator Output Test OVCO Circuit With engine off, unplug alternator-to-regulator harness. Connect DMM red lead to socket A on harness plug. Connect black lead to alternator anti-drive end B+ terminal. Does resistance measure about 1.0 ± 0.2 ohms? Connect DMM red lead to socket A on alternator-toregulator harness plug. Connect black lead to alternator anti-drive end B terminal. Does continuity exist? Connect DMM red lead to socket A on alternator-to-regulator harness plug. Connect black lead to alternator case. Does continuity exist? Regulator is defective. SOCKET CONNECTIONS Pin A F Pin B AC Terminal Pin C B Pin D B+ Figure 10 Alternator-to-Regulator Harness Plug If you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Dealer, please contact us at: C. E. Niehoff & Co. 2021 Lee Street Evanston, IL 60202 USA TEL: 800.643.4633 USA and Canada TEL: 847.866.6030 outside USA and Canada FAX: 847.492.1242 E-mail us at service@ceniehoff.com Page 10