Degussa Construction Chemicals (Schweiz) AG Division CONICA Technik Industriestrasse 26 CH 8207 Schaffhausen October 19, 2004

Similar documents
Synthetic Sports Surfacing Suitability Test acc. to DIN V : Description Type Single Layer with flat texture, porous

TECHNICAL INFORMATION

MATERIAL DATA SHEET* ALPANA d.o.o.

President For the Accreditation Council Certificate Number Valid to August 31, 2008

DILLARD'S INC TEST PROTOCOL FOR DILL USA- (V13) KEYCHAIN / BATTERY OPERATED KEYCHAIN / KEYCHAIN WITH LIGHT

MIRTA-KONTROL d.o.o. LABORATORY DEPARTMENT

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

Certificate of Accreditation

Full extension concealed slide with soft closing and self-closing

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

Sealon Adhesive PTFE Gasket Tape. Technical Data Sheet

FABRIC-RUBBER CONVEYOR BELTS, GENERAL PURPOSE

It may not be used for commercial purposes, unless it is reproduced in its entirety

Incinerator Monitoring Program Ash Characterization Summary

Why compromise on infill quality?

CERTIFICATE OF ACCREDITATION

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Evaluation report. tests of material samples for the parameters heavy metals (Pb, Cd, Cr, Cu, Ni, Zn, Hg) LVHH, BTEX, PDH, PAH and EOX

No. HKGEC Date: 13 Oct 2017 Page 1 of 10

Incinerator Monitoring Program Ash Characterization Summary

Water Supply and Sewerage Approved Products Manual - February 2006

Certificate of Accreditation

Korea Eco-label Standards EL764 Revised 19. JUL Ministry of Environment Batteries EL764:2012

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Introduction to the ICAO Engine Emissions Databank

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

Permaglide lead-free The new generation of materials. Technical Product Information

DECLARATION OF CONFORMITY REGARDING END-OF LIFE VEHICLES (EL V)

APPENDIX: TECHNICAL INFORMATION

EU RO Mutual Recognition Technical Requirements

Components: Dimensions / Order Codes Clamp Body. * 1st part of STAUFF Group 4. * Exact outside diameters Ø D1 / Ø D2 (mm) Clamp Body.

: PARTICLE INDUSTRIES, INC 126 POST ST, 4TH FLOOR, SAN FRANCISCO, CA USA SUMMARY OF TEST RESULTS

Restriction of the use of certain hazardous substances (RoHS) Summary Report

Certificate of Accreditation

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Use of New High Performance Thin Overlays (HPTO)

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

DECLARATION OF CONFORMITY REGARDING RESTRICTIONS OF HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

DRB Power Transmission Belts

TEST REPORT. Version:V1.0 Page 1 of 9. Client company : Berdis Lighting Co., LTD.

Technical Report No D Dated

Components: Dimensions / Order Codes

Name of Laboratory : SGS CAMBODIA LABORATORY Accreditation Number : Testing : 1076 A-C, Street 371, Sangkat Stung Meanchey, Khan Meanchey,

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BRISTLE BLASTING SURFACE PREPARATION METHOD FOR MAINTENANCE. Neil Wilds

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac

Good crack bridging ability Mechanically resistant if broadcast Watertight Easy application Solvent free

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

Components: Dimensions / Order Codes. Clamp Body * *1*06*PP * * * * Clamp Body. ød2. Pipe / Tube / Hose Bore (1 Clamp Body)

Hoist Chains. Hebezeugketten

DILLARD S TEST PROTOCOL FOR DILR US LUGGAGE (V26)

Test Report No. C Date: Sep 14, 2016 Page 1 of 11

1996, or for which modification is commenced on or before March 16, 1998, shall not exceed the

To the participants of AQS Baden-Württemberg Dear Madam or Sir,

Test Report. CHTC JIAHUA NONWOVEN CO.,LTD No.99,WaGou New Village, Pengchang,Xiantao,Hubei, CHINA

TECHNICAL CERTIFICATE

VALSIR SUPPLY SYSTEMS MIXAL

Safety and Quality 2.0 Bike Specifications

LITHIUM MANGANESE DIOXIDE

Technology on Your Wavelength

PRODUCT SAFETY DATA SHEET

Atut Sp. z o.o. INDUSTRIAL FILTRATION INDUSTRIAL FILTRATION PAGES. Dystrybucja:

Melos Infill EPDM ST. Made for top performances: Infill Granules by Melos. »Our aim: Infill granules for the perfect artificial turf system«

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

MITRAS MATERIALS GMBH

Tyre Performance Enhancement with Plasticising Oils

PE-HDXc pipes (physically cross-linked polyethylene pipes)

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Mauro Fedeli 18 th November green System. Goglio Group foundation

APPLICATION FOR SAFETY OF TOYS DIRECTIVE On Behalf of. Nanjing Feeling Rubber & Plastic Produces Co., Ltd. EPDM Rubber Granule

Test Report Electrochemical Impedance Spectroscopy

2-part PUR highly elastic, crack-bridging coating. Sikafloor -350 N Elastic is a two part, solvent free, highly elastic polyurethane resin.

Implementation and Thickness Optimization of Perpetual Pavements in Ohio

Product Data Sheet 624 NR. The engineer's choice

Obtaining ASTM D6400- D6868 Approval

PRESSURE MONITORING.

: JUSTFOG DONGGUAN CO., LTD. BLDG, 3, DASHADUN INDUSTRIAL PAPK, WUSHAJIANGBEI VILLAGE, CHANG AN TOWN, DONGGUAN. SUMMARY OF TEST RESULTS

Surface Protective Systems

Experiences with domestic waste treatment and co-processing of Solid Recovered Fuels (SRF)

Automotive Testing and Engineering Services

LFS-UFP-T4. No Clean Solder Paste SAC 305 (Sn96.5/Ag3.0/Cu0.5) Lead Free DESCRIPTION APPLICATION BENEFITS REFLOW EQUIPMENT AND CIRCUIT CLEANING

TRACE ELEMENTS IN URINE. Event #3, 2012

Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

Test Report No. BR Rev. 0 Date: Barueri, 27 Jul 2017 Page 1 of 7

TUFCOTE 3.3 PR HIGH SOLIDS FAST DRY ALKYD PRIMER (formerly DuPont 681 FD )

Benteler Distribution. Steel tube solutions for hydraulic and pneumatic applications

TEST REPORT Test Report # 17A E Date of Report Issue: April 24, 2017 Date of Sample Received: April 14, 2017 Pages: Page 1 of 8

Sequence VH Report Forms Version Conducted For

Elevator parts. Supplier of spare parts for the international bulkhandling industry. Bechtel supplies various components for elevators:

Technical Report No Rev. 00 Dated

Inductive conductivity meter

Locking Assemblies for use with bending loads

Surface Protective Systems

Transcription:

Degussa Construction Chemicals (Schweiz) AG Division CONICA Technik Industriestrasse 26 CH 8207 Schaffhausen October 19, 2004 L A B R E P O R T USSL Reference: Subject: 5928US/Kol/gl Synthetic Sports Surfacing Suitability Test acc. to DIN V 18035-6:2004-10 1. Description of Sample Name of Product CONIPUR SP Description Type Synthetic Surface with Structural Spray Coating, impermeable Top Layer CONIPUR Structural Spraycoat Grain Size of EPDM Granules 0.5/1.5 mm Amount above Base Layer: 1000 g/m 2 (total application rate about 2000 g/m 2 ) Base Layer Black Rubber Granules, bound by CONIPUR Binder Thickness 12 mm Total Thickness 13 mm 2. Sampling Identification of material deposited with USSL Location Degussa Construction Chemicals Date November 2003 This report consists of 6 pages. Reproduction or printing is only admissible in whole and in conformity with the original. Update October 19, 2004: Merger of Reports dated January 16, 2003 and January 19, 2004 acc. DIN V 18035-6:2004-10 506 Cedar Lane Hopewell, VA 23860 804/541-7212 804/541-7207 (Fax) E-mail postmaster@ussl-testing.com IAAF Accredited Laboratory

Page 2 of 6 Report #5928US, October 19, 2004 3. Delivery of Samples Date November 11, 2003 Amount and Size of Samples 4 sections 50 cm x 50 cm Sample No. 5204 4. Test Procedures The tests reported in paragraph 5 were performed according to DIN 18035-6:1992. The climate during testing was Type 23/50 according DIN 50014 if not indicated otherwise. The test results are opposed to the requirements of DIN V 18035-6:2004-10. Since the test procedures (paragraph 5) have not changed since 1992, results can be assessed with reference to the 2004 version of DIN 18035-6. 5. Test Results (DIN V 18035-6, Table 4, Line 1-9) 5.1 Modified Vertical Deformation Temperature +0 C +23 C +40 C Modified Vert. Deformation 0.7 mm 0.9 mm 1.0 mm Requirement: 4.0 (PF) 0.6 1.8 mm (RT) PF = Playing Fields; RT = Running Track 5.2 Force Reduction Temperature +0 C +23 C +40 C Force Reduction KA 55 31 % 37 % 39 % Requirement: >45% (PF) none (RT)

Page 3 of 6 Report #5928US, October 19, 2004 5.3 Thickness Total thickness of Surface 13 mm (absolute) Requirement:. >13 mm (RT) >20 mm (PF) 5.4 Abrasion rel. Abrasion ra = 3.8 Requirement (PF+RT) >1.0 (structuredttexture) > 5.0 (flat texture) After 5 Cycles the Abrasion was about 32 % of the Abrasion after 20 Cycles 5.5 Permeability Waterpermeability 0.039 cm/sec Requirement (PF+RT): min. 0.01 cm/sec (if permeable) 5.6 Friction Surface Condition Test Sole Sliding Coefficient DIN V 18035-6/TRRL Dry Requirement: <0.0 (PF) > 1.1 (RT) Wet Requirement >0.5 (PF/RT) Leather Leather 0.68 0.50

Page 4 of 6 Report #5928US, October 19, 2004 5.7 Spikes Resistance Class I acc. DIN V 18035-6 Requirements: PF none RT min. Class I 5.8 Remaining Indentation max. Indentation when loaded Remaining Indentation (RI) Requirement (PF+RT): RI 1.0 5.7 mm 0.4 mm 5.9 Tensile Properties Tensile Strength 0.75 N/mm 2 Requirement (PF+RT): 0.3 Elongation at Break 69 % Requirement(PF+RT): 40

Page 5 of 6 Report #5928US, October 19, 2004 5.10 Ageing Exposure (Climate) Tensile Strength N/mm 2 Q Z Elongation at Break % Q B Modulus of Deform. N/mm 2 Q E Change of Color Class: Standard Climate 23/50 DIN 50014 0.75 / 1.00 69 / 1.00 2.53 / 1.00 - Constant Climate w/ Condensation SK 40/100 DIN 50017 0.76 / 1.07 62 / 0.90 3.09 / 1.22 5 Constant Heat Climate 80 C 0.95 / 1.27 75 / 1.09 2.98 / 1.18 5 Combined Climate of Heat, Humidity and Light DIN 53387 0.84 / 1.12 72 / 0.90 2.72 / 1.07 4-5 Requirements (PF+RT): Q z 0.75, Q B 0.75; Q E 0.75-1.25 In all tests, the change of color and brightness of the exposed samples in compared with the initial condition of the samples was rated equal or better than 'Color Change Class 4 according to DIN 54001 (Class 1 = worst, Class 5 = best). Requirement (PF+RT): Class 3

Page 6 of 6 Report #5928US, October 19, 2004 6. Environmental Compatibility Pollutant Content of Extract (DIN V 18035-6, Table 6, Lines 1-13) Parameter Results of Analysis mg/l Limits according DIN V 18035-6:2004-10 mg/l DOC - 48 h Result 7 max. 40 or 20 resp. EOX Extraction ----*) max. 100 mg/kg Lead (Pb) < 0.005 max. 0.04 Cadmium (Cd) < 0.0005 max. 0.005 Chromate total (Cr) < 0.005 max. 0.05 Chromate VI (CrVI) < 0.008 max. 0.008 Mercury (Hg) < 0.0002 max. 0.001 Zinc (Zn) 0.8 max. 3.0 Tin (Sn) < 0.005 max. 0.05 Biological Decomposition ---- No requirement**) Smell no smell Description Visual condition not muddy Description Inhibition of Nitrification ---- No requirement *) Determination of EOX only if DOC >20 **) Determination when needed only 7. Conclusions The synthetic surfacing tested complied with the requirements of DIN V 18035-6:2004-10 in respect to Light Athletic Sports Areas. The test results listed above describe the properties of the submitted sample. They apply to the product in general if the product is manufactured/installed using the same material components and the same installation technique as used with the sample tested. Dipl.Ing. H.J. Kolitzus