0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring Covers Optional Output Meter for Local Indication The Displacer Sensor Measures Changes in Liquid Level, Specific Gravity, or Interface Level, and the Controller or Transmitter Sends a Pneumatic Signal that is Proportional to the Changes The Series Displacer is Contained in a Rugged Cage for Mounting on the Side of a Tank, or the Displacer can be Suspended in a Tank without a Cage Tank Flanged Connections to -Inch Size General Specifications.... - Performance............ - Power Supply........... - Temperatures........... - Materials.............. -0 Sensor Sizes, Connections, and Ratings............. - Classifications.......... - Connection Styles and Positions............ -
0- Level-Trol Series General Specifications Transmitter Selections (Also Refer to Sensor Table) Options Performance Input Signal Output Signal Span Adjustment Zero Adjustment Electronic liquid level transmitter: Type 0 or 0B (Refer to the Classifications section for ratings) Liquid level, interface level, or density changes move the displacer up or down to provide rotary motion ot the torque tube shaft to 0 ma dc (direct increasing input increases output; or reverse increasing input decreases output) 0 to 00% of displacer length for level applications using a standard volume displacer 00% of displacer length Ambient Relative Humidity 0 to % Type 0 and 0B liquid level transmitters Transmitter output reference accuracy Hysteresis Repeatability Analog output meter Heat insulator; Series Level Sensor Gauge glass for presures to bar at C or 0 psig at 0 F; and Reflex gauges for high temperature and pressure Transmitter (Specific Gravity of.0) 0.% of full scale output 0.% of full scale 0.% of full scale Dry span calibration.% of full scale at a specific gravity of.0 Optional analog output meter.% of full scale Transmitter and Sensor (Specific Gravity of.0; Standard Torque Tube) Independent linearity Hysteresis 0.% of full scale output 0.% of full scale output W#??? Optional Output Meter W00-/IL Cageless Sensor W-/IL Caged Sensor -
0- Level-Trol Series Power Supply Standard to V dc with reverse polarity protection Temperatures Temperaturere LCIE or PTB (CENELEC) Approved to. V dc for intrinsically safe (PTB) and to V dc (with reverse polarity protection) for flameproof (LCIE) Type or Material CSA or SAA Certified or FM Approved to 0 V dc with reverse polarity protection C Temperature Capability Load Resistance Refer to the Load Resistance curve. Maximum for a -0 ma circuit is 00 ohms at V F TRANSIENT POWER SURGE PROTECTION No damage for a line-to-line surge of up to 00 kilowatts for 00 nanoseconds or. kilowatts for millisecond Ambient Type 0 and 0B 0 to 0 0 to Cast iron sensor parts to 0 to 0 For process temperatures Steel sensor parts to 0 to 0 below C or 0 F and for guidance on the need for Stainless steel sensor parts to to 0 a heat insulator, contact your Process N000 torque tube to to 00 sales office. Graphite/stainless steel If the ambient dew point is to to 00 gaskets higher than the process temperature, ice might form Monel/PTFE gaskets to 0 00 to 00 and cause instrument Combination of ambient and process Some combinations of process and ambient temperatures within the above require an optional heat insulator to protect the instrument from high or low temperatures. For example, an ambient temperature of 0 C or F and a process temperature of 00 C or F require a heat insulator. malfunction and reduce insulator effectiveness. Notes -
0- Level-Trol Series Materials Part Sensor Type Standard Material Notes Cage, head, and torque tube arm Torque tube Sensor Cast iron CP CFM ( stainless steel) K, L, and N Steel P and V All except CP CP All except CP and L Cast iron or steel N000 (K-Monel) S00 ( stainless steel) S000 (0 stainless steel) Displacer CP S00 L A00F (solid aluminum) Bolting Case and cover Internal parts All Transmitter B steel studs or cap screws and H steel nuts Aluminum Plated steel, aluminum, and stainless steel; conformal coating on printed wiring board For optional materials and for parts not shown, contact your sales office. - - - -0
0- Level-Trol Series Sensor Sizes, Connections, and Ratings Rating Size Connection Type Class or 0; cast iron Caged Displacers PN 0/, /0, or /00; steel DN 0 PN 0/ or /0; steel DN 0 -/ or inches Screwed or flanged inches Flanged Flanged Sensor Type Number Class 00; steel NPT or socket-welding ends BF Class 0, 00, or 00; steel -/ or inches Class 00; steel Class 00; steel Class 00; steel -/ or inches inches (if a top connection is specified, it will be -inch flanged) -/ or inches Top-Mounted Cageless Sensors Ring-type joint flanged Class 0, 00, or 00; stainless steel inches Raised-face flanged CP PN0/, /0, or (Ratings to PN 0 also available); steel or stainless steel Class 00 or 00; steel or stainless steel DN 00 inches Flanged Class 0 through 00; steel or stainless steel or inches Raised-face flanged Side-Mounted Cageless Sensors Class or 0; cast iron inches Flat-face flanged Class 0; steel Class 00 through 00; steel inches inches flat-face flanged Class 00; steel inches Ring-type joint flanged Class 0; stainless steel Class 00, 00, or 00; stainless steel Displacer Lengths and Volumes Sensor Type Number inches inches Displacer Length flat-face flanged Displacer Volume Caged Displacers mm Inches cm Inches or or BF K L N Top-Mounted Cageless Sensors CP P Side-Mounted Cageless Sensors V,,,,,,,, 0,,, 0,,,, 0, 0 K L N P V Type e CP: Type e CP: 0 All others: All others: 00 -
0- Level-Trol Series Classifications The Type 0 and 0B are available with the European CE Mark ( ) and Australian C-Tick Mark ( ). AGENCY TYPE NUMBER TYPE OF PROTECTION INTRINSIC SAFETY OR NON-INCENDIVE ENCLOSURE RATING FM 0 Class I, Division, Groups A, B, C, D--T NEMA CSA 0 Class I, Division, Groups A, B, C, D--TA Type X PTB 0B EEx ia IIC T IP BASEEFA 0B EEx ia IIC ET AL SAA 0 FLAMEPROOF Ex ia IIC T Ex n IIC T IP SAA 0 Ex d IIC T (T amb = 0 C) IP NOTE Contact your sales office for the appropriate FM entity ratings and CSA parametric ratings for each group. Applicable for Class II, Division, Groups E, F, and G if barrier approval permits. LCIE 0B EEx d IIC T IP - - - DIVISION FM 0 CSA 0 FM 0 CSA 0 Class I, Division, Groups A, B, C, D Class II, Division, Groups F, G Class I, Division, Groups A, B, C, D Class II, Division, Groups E, F, G EXPLOSION PROOF Class I, Division, Groups A, B, C, D--T Class II, Division, Groups E, F, G--T Class I, Division, Groups A, B, C, D--T Class II, Division, Groups E, F, G--T NEMA Type X NEMA X Type X Poured seal is is requiredwithin mm or inches. -
0- Level-Trol Series Connection Styles and Positions TOP CON- NECTION ALTERNATE POSITIONS FOR LEFT OR RIGHT HAND MOUNTING UPPER SIDE CONNECTION APPROXIMATE DISPLACER LENGTH LEFT HAND MOUNTING (INSTRUMENT ON LEFT OF SENSOR WHEN VIEWED AS SHOWN) LEFT TANK LOWER SIDE CONNECTION BOTTOM CONNECTION A/IL A/IL Connection Types: T = Threaded F = Flanged Style Style Style Style Connection Upper size and Upper side and Locations: Top and bottom Top and lower side lower side bottom Example: F- means flanged connections at the top and bottom of the cage. -