Tank Car Fire-Tite Top-Loading and Unloading Valves

Similar documents
Railroad Ball Valves Series 5REB3

Standard Bore Flanged Ball Valves Series 7150, 730S & , 4 & 6 (DN 80, 100 & 150) Class 150 & 300

Reduced Bore Thread-end Ball Valves Series 33R Model C. 1/2 2 (DN 15-50) AAR No. E079024

3-Piece Ball Valves Series 4000 Model A

3 AND 4 CLASS 300 STANDARD BORE SERIES 730S AND 7300 REACTOR DISCHARGE VALVES. Installation, Maintenance and Operating Instructions

ICV & ICVA Flanged Injection Control Valves 2 (DN 50) Type Installation, Maintenance and Operating Instructions

Series 7000 Railroad, Standard Bore Flanged Ball Valves

SERIES CLASS 300 FULL-BORE REACTOR DISCHARGE VALVES. Installation, Maintenance and Operating Instructions

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES

SERIES 2 4 (DN ) 6300, 2 6 (DN ) 6150, 6 (DN 150) 5300 & 530S, 6 & 8 (DN 150 & 200) 5150 BALL VALVES

3, 4 & 6 (DN 80, 100 & 150) CLASS 150 & 300 STANDARD BORE SERIES 7150, 730S & 7300 FLANGED BALL VALVES EQUIPPED WITH KEROTEST HANDLE ASSEMBLIES

JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150. Installation, Maintenance and Operating Instructions

CLINCHER 2-Piece Thread-end Ball Valves Series 2000

VALUE-LINE 3-Piece Ball Valves Series 3A & 3C 1/2 2 (DN15-50) Installation, Maintenance and Operating Instructions

Series 7000 & 9000 Ball Valves

3-Way Flanged Ball Valves Series AM150FD & AM150FB Model A

Installation, Maintenance and Operating Instructions

Flanged Ball Valves Series 5000 Model B & C. Series 6000 Model B & C. ½ - 2 (DN15-50) Class 150 & 300. ½ 1 ½ (DN15-40) Class 150 & 300

3-Way Flanged Ball Valves 6, 8 & 10 (DN150, 200 & 250) Model D Series DM150FD 6 & 8 (DN150 & 200) Series DM150FB Model D

REACTOR DISCHARGE VALVES S AND WITH MD, QA AND QC CONVERSIONS AND ESSD STEM SEAL OPTION

ICV & ICVA Injection Control Valves Series 4000 Model C. Installation, Maintenance and Operating Instructions

3-Way Flanged Ball Valves Series AM150FD & AM150FB Model A 3 & 4 (DN80 & 100) Class 150. Installation, Maintenance and Operating Instructions

3-Way Flanged Ball Valves 12 (DN300) Series DM150FD Model A

Series 7000 & 9000 Ball Valves Non-Trunnion

Installation, Maintenance and Operating Instructions

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES

VALV-POWR VALUE-LINE DOUBLE-OPPOSED PISTON ACTUATORS MODEL A. Installation, Maintenance and Operating Instructions

VALVCON Universal ADC-Series Sealed Lead Acid Back-Up Battery Upgrade Kits. Installation, Maintenance and Operating Instructions

Installation, Maintenance and Operating Instructions

EMISSION-PAK SERIES 7000 AND 9000 BALL VALVES

Cryogenic Wafer-Sphere Butterfly Valves

NELES SOFT SEATED BALL VALVES, SEAT SUPPORTED, FULL AND REDUCED BORE, SERIES X

Delayed Coker Switch Ball Valve

Wafer-Sphere Butterfly Valve Series 835W & 835L (DN )

EMERGENCY SHUTOFF AND FIRESAFE VALVES FIGURE 1075

NELES BO SERIES BUTTERFLY VALVE FOR RECOVERY OF OXYGEN IN VACUUM PRESSURE SWING ADSORPTION (VPSA) PLANTS

Wafer-Sphere Butterfly Valve Model C

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Wafer-Sphere, High Performance Butterfly Valves

K815W, K815L, K830W, K830L, K860W, & K860L Wafer-Sphere Butterfly Valve. Installation, Maintenance and Operating Instructions

HAND WHEEL OPERATOR For cylinder actuators Types B1C_K/L/R and B1C_RK/RL/RR Installation, Maintenance and Operating Instructions

Wafer-Sphere 14" 20" Butterfly Valve. Installation, Maintenance and Operating Instructions

1/4 2 (DN 8 50) ELIMINATOR 2000 CWP AND ASME CLASS 600 THREADED END BALL VALVE

Wafer-Sphere Butterfly Valve Series K815W, K815L, K830W & K830L Model A Cryogenic

1/4" 2" (DN 8 50) A-STYLE MODEL D THREADED END 2000 CWP BALL VALVE

NELES RE2-SERIES V-PORT SEGMENT VALVE

MAPAG Butterfly valve - Type BK For cryogenic applications. Installation, Maintenance and Operating Instructions

4" 9RET/REL FULL-PORT BOTTOM- OUTLET VALVES (AAR NO. E079011)

IMO -272 ISSUE 6/95 SERIES MBV, METAL-SEATED FLANGED BALL VALVES 3", 4" AND 6" CLASS 150 AND 300 STANDARD BORE, MB AND MC

PNEUMATIC CYLINDER UNIT. Series CP Installation, Maintenance and Operating Instructions

Wafer-Sphere Butterfly Valves

Valv-Powr VPVL Mod C Value-Line Double-Opposed Piston Actuators. Installation, Maintenance and Operating Instructions

1/4" 2" (DN 8 50) Clincher Series 2000 Threaded-End Ball Valves

Polymerization High cycle valves

SERIES 835 PROCESS-RATED CLASS 150 WAFER-SPHERE HIGH-PERFORMANCE BUTTERFLY VALVES

NELES TRUNNION MOUNTED BALL VALVE, FULL BORE Series XH Installation, Maintenance and Operating Instructions

Control Valves Globe 3-way, Diverting & Mixing type Series GW Installation, Maintenance and Operating Instructions

Control Valves Globe 3-way, Diverting & Mixing type Series GW Installation, Maintenance and Operating Instructions

NELES METAL SEATED BALL VALVES, SEAT SUPPORTED, FULL AND REDUCED BORE, SERIES X

Series VC Pneumatic cylinder actuators

VALV-POWR SERIES VPVL MODEL D DOUBLE-ACTING AND SPRING-RETURN RACK- AND-PINION COMPACT PNEUMATIC ACTUATORS

CAPPING VALVE. Series PZ Installation, Maintenance and Operating Instructions

1/4" 2" (DN 8 50) ELIMINATOR 2000 CWP AND ANSI CLASS 600 THREADED END BALL VALVE

Control Valves Globe-Unbalanced Single Seated, Series GU Installation, Maintenance and Operating Instructions

NELES RE-SERIES V-PORT SEGMENT VALVE

Control Valves Globe-Omega, Multistage trim Series GM Installation, Maintenance and Operating Instructions

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

1/4" 2" (DN 8 50) ELIMINATOR 2000 CWP AND ANSI CLASS 600 THREADED END BALL VALVE

NELES R-SERIES SEGMENT VALVE Flanged RE and Wafer RE1

6D15 DIGESTER CAPPING VALVES

Ceramic Ball Valves. Series E2 and E6. Installation, Maintenance and Operating Instructions

PNEUMATIC CYLINDER UNIT. Series CS Installation, Maintenance and Operating Instructions

NELES RA SERIES V-PORT SEGMENT VALVE

Double Acting Cylinder Actuator Series VC Installation, Maintenance and Operating Instructions

MANUAL GEAR ACTUATORS

METSO NELES HIGH PERFORMANCE TRIPLE ECCENTRIC DISC VALVE, METAL SEATED SERIES BW

Steam reforming. The product is then ready to be used in refinery applications or for synthesis of ammonia or methanol. APPLICATION REPORT CLOSEOPEN

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

TRUNNION MOUNTED FULL BORE MBV BALL VALVE Series XG, XM Installation, Maintenance and Operating Instructions

JAMESBURY VALVCON ESR-SERIES ELECTRONIC SPRING RETURN ELECTRIC ACTUATOR

V-port segment valves Series R1L Titanium Series R21L Titanium Series R2_S High consistency. Installation, Maintenance and Operating Instructions

VALV-POWR SERIES VPVL MODEL C DOUBLE-ACTING AND SPRING-RETURN RACK- AND-PINION COMPACT PNEUMATIC ACTUATORS

Metso Product Portfolio Valve & Actuator Overview

JAMESBURY VALVCON QX-SERIES ELECTRIC ACTUATOR

DIN FLANGED BALL VALVES

1/4 2 (DN 8 50) CLINCHER SERIES 2000 THREADED-END BALL

Pneumatic Cylinder Actuators Series B1C Installation, Maintenance and Operating Instructions

Series A Installation, Maintenance and Operating Instructions

Fisher TBX Hydro Plug Fixture

Jamesbury High-Performance Actuators. Maximizing cycle life. Lowering Costs.

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Fisher CVX Hydro Plug Fixture

Jamesbury Wafer-Sphere World s Best Gate Crasher

IMO - 528EN Issue Date: 1/11

Spring Diaphragm Actuator Series VD Installation, Maintenance and Operating Instructions

Fisher RSS Lined Globe Valve

Propane Dehydrogenation Continuous catalyst regeneration applications

NELES HIGH CAPACITY TRIPLE ECCENTRIC DISC VALVE, METAL SEATED NELDISC SERIES L6

Fisher RSS Lined Globe Valve

Transcription:

Tank Car Fire-Tite Top-Loading and Unloading Valves 1 & 2 7RRR & 7RRT, 2 7RRU Installation, Maintenance and Operating Instructions IMO-R21 EN 11/2017

2 IMO-R21 EN TABLE OF CONTENTS 1. GENERAL... 3 1.1 Scope of the Manual... 3 1.2 Valve Markings... 3 1.3 Safety Precautions... 3 2. TRANSPORTATION AND STORAGE... 3 3. INSTALLATION... 4 3.1 General... 4 3.2 Handles... 4 3.3 Installing on tank car... 4 3.4 Commissioning... 4 4. MAINTENANCE... 4 4.1 General... 4 4.2 Disassembly... 5 4.3 Checking Parts... 5 4.4 Assembly... 6 4.5 Testing the Valve... 7 5. REPAIR KITS... 7 6. SERVICE/SPARE PARTS... 7 READ THESE INSTRUCTIONS FIRST! These instructions provide information about safe handling and operation of the valve. If you require additional assistance, please contact the manufacturer or manufacturer s representative. Addresses and phone numbers are printed on the back cover. See also www.metso.com/valves for the latest documentation. SAVE THESE INSTRUCTIONS! Subject to change without notice. All trademarks are property of their respective owners.

IMO-R21 EN 3 1. GENERAL 1.1 Scope of the Manual This instruction manual contains important information regarding the installation, operation and troubleshooting of the Jamesbury 1 (DN 25) and 2 (DN 50) 7RRR and 7RRT and 2 (DN 50) 7RRU Tank Car Fire-Tite Top-Loading and Unloading Valves. Please read these instructions carefully and save them for future reference. AS THE USE OF THE VALVE IS APPLICATION SPECIFIC, A NUMBER OF FACTORS SHOULD BE TAKEN INTO ACCOUNT WHEN SELECTING A VALVE FOR A GIVEN APPLICATION. THEREFORE, SOME OF THE APPLICATIONS IN WHICH THE VALVES ARE USED ARE OUTSIDE THE SCOPE OF THIS MANUAL. IF YOU HAVE ANY QUESTIONS CONCERNING THE USE, APPLICATION OR COMPATIBILITY OF THE VALVE WITH THE INTENDED SERVICE, CONTACT METSO FOR MORE INFORMATION. 1.3 Safety Precautions DO NOT EXCEED THE VALVE PERFORMANCE LIMITATIONS! EXCEEDING THE PRESSURE OR TEMPERATURE LIMITATIONS MARKED ON THE VALVE IDENTIFICATION PLATE MAY CAUSE DAMAGE AND LEAD TO UNCONTROLLED PRESSURE RELEASE. DAMAGE OR PERSONAL INJURY MAY RESULT. SEAT AND BODY RATINGS! THE PRACTICAL AND SAFE USE OF THIS PRODUCT IS DETERMINED BY BOTH THE SEAT AND BODY RATINGS. READ THE IDENTIFICATION PLATE AND CHECK BOTH RATINGS. THIS PRODUCT IS AVAILABLE WITH A VARIETY OF SEAT MATERIALS. SOME OF THE SEAT MATERIALS HAVE PRESSURE RATINGS THAT ARE LESS THAN THE BODY RATINGS. ALL OF THE BODY AND SEAT RATINGS ARE DEPENDENT ON VALVE TYPE AND SIZE, SEAT MATERIAL, AND TEMPERATURE. DO NOT EXCEED THESE RATINGS! 1.2 Valve Markings The valve has an identification plate (22) attached to the flange (see Figure 1). BEWARE OF BALL MOVEMENT! KEEP HANDS, OTHER PARTS OF THE BODY, TOOLS AND OTHER OBJECTS OUT OF THE OPEN FLOW PORT. LEAVE NO FOREIGN OBJECTS INSIDE THE TANK CAR. WHEN THE VALVE IS ACTUATED, THE BALL FUNCTIONS AS A CUTTING DEVICE. FAILURE TO DO THIS MAY RESULT IN DAMAGE OR PERSONAL INJURY. 2. TRANSPORTATION AND STORAGE Check the valve and the accompanying devices for any damage that may have occurred during transport. Figure 1 Identification plate Identification plate markings: 1. Ball/Stem material 2. Valve catalog code & Serial Number 3. Seat Material 4. Body Material 5. Maximum operating pressure 6. Maximum/minimum shut-off pressure/temperature 7. Approvals/Special Service marking 8. Valve Model 9. Assembly date Store the valve carefully. Storage indoors in a dry place is recommended. Do not remove the protective packaging or flow port protectors until installing the valve. Move the valve to its intended location just before installation. The valve is usually delivered in the open position. If the valve(s) will be stored for a long period, follow the recommendations given in IMO-S1 to maintain the valve integrity.

4 IMO-R21 EN 3. INSTALLATION 3.1 General Remove the protective packaging and flow port protectors and check that the valve is clean inside. Clean valve if necessary. Flush the tank car carefully before installing the valve. Foreign objects, such as sand or pieces of welding electrodes, will damage the ball and seats. Read and follow all WARNINGS! 3.4 Commissioning Ensure that there is no dirt or foreign objects left inside the valve or tank car. Flush the tank car carefully. Make sure that the valve is fully open when flushing. Ensure that all nuts and fittings are properly fastened. GOOD PRACTICE DICTATES THAT ONCE INSTALLED, BUT PRIOR TO FIRST USE, THE VALVE IS LEAK TESTED IN PLACE TO ASSURE LEAKTIGHTNESS HAS NOT BEEN COMPROMISED BY THE INSTALLATION PROCESS. INSTALLATION ACTIONS THAT CAN CAUSE LEAKAGE INCLUDE, BUT ARE NOT LIMITED TO; WRENCHING, SOLDERING, WELDING AND/OR HOISTING. SEE SECTION 4.5 SERIES 7RRR, 7RRT AND 7RRU VALVES ARE DESIGNED FOR MANUAL USE ONLY AND ARE NOT INTENDED FOR AUTOMATION! DO NOT FABRICATE OR ADD ON ANY TYPE OF AUTOMATING ACCESSORY. The Jamesbury Series 7RRR, 7RRT and 7RRU are an end entry design with an internal insert. The insert contains a hex drive which can be identified by looking into the end of the valve before installation. 3.2 Handles If the Series 7RRR, 7RRT or 7RRU valve handle (17) has to be removed for any reason, the handle must be remounted with the handle as shown in Figure 8 or 9. FAILURE TO PROPERLY MOUNT THE HANDLE MAY RESULT IN IMPROPER VALVE OPERATION, DAMAGE OR PERSONAL INJURY. 3.3 Installing on tank car THE VALVE SHOULD BE TIGHTENED BETWEEN FLANGES USING APPROPRIATE GASKETS AND FASTENERS COMPATIBLE WITH THE APPLICATION, AND IN COMPLIANCE WITH APPLICABLE PIPING CODES AND STANDARDS. CENTER THE FLANGE GASKETS CAREFULLY WHEN FITTING THE VALVE BETWEEN FLANGES. DO NOT ATTEMPT TO CORRECT MISALIGNMENT BY MEANS OF FLANGE BOLTING! The valve may be installed in any position and offers tightness in both directions. It is recommended, however, that the valve be installed with the insert (2) towards the tank car. Refer to the Section 4, MAINTENANCE for stem seal adjustment. If there is weepage past the stem seals upon installation, it means the valve may have been subject to wide temperature variations in shipment. Leak-tight performance will be restored by a simple stem seal adjustment described in the MAINTENANCE section. 4. MAINTENANCE 4.1 General Good operating procedure requires periodic observation to ensure that the valve is functioning well. The frequency of observation will depend on the application. Routine maintenance consists of tightening the bonnet cap screws (item 29 in Figure 8 or 9) periodically to compensate for stem seal wear. More frequent observation is recommended under extreme operating conditions. Overhaul maintenance consists of replacing seats and seals. A standard repair kit consisting of these parts may be obtained through your authorized Metso Distributor. NOTE: Repair kits include stem bearings (13), secondary stem seal (7), seats (5), body seal (6) and stem seal (8). Refer to the Repair Kit chart (see Table 3). FOR YOUR SAFETY IT IS IMPORTANT THE FOLLOWING PRECAUTIONS BE TAKEN PRIOR TO INSTALLATION, SERVICING OR REMOVAL OF THE VALVE FROM THE TANK CAR OR BEFORE ANY DISASSEMBLY: 1. WEAR ANY PROTECTIVE CLOTHING OR EQUIPMENT NORMALLY REQUIRED WHEN WORKING WITH THE FLUID INVOLVED. 2. DEPRESSURIZE THE TANK CAR AND CYCLE THE VALVE AS FOLLOWS: A. PLACE THE VALVE IN THE OPEN POSITION AND DRAIN THE TANK CAR. B. CYCLE THE VALVE TO RELIEVE RESIDUAL PRESSURE IN THE BODY CAVITY BEFORE REMOVAL FROM THE TANK CAR. C. AFTER REMOVAL AND BEFORE ANY DISASSEMBLY, CYCLE THE VALVE AGAIN SEVERAL TIMES. 3. THESE VALVES ARE SUITABLE FOR A WIDE VARIETY OF FLUIDS AND GASES. BE CERTAIN THAT THE VALVE MATERIALS SELECTED ARE SUITABLE FOR THE APPLICATION.

IMO-R21 EN 5 5. Close the valve. 6. Clamp the valve body (1) securely in a vise in the vertical position with the insert end up, taking care not to damage any valve sealing surfaces. 7. Unscrew and remove insert (2). The insert design requires that the insert be unscrewed in a counterclockwise motion. Figure 2 1 (DN 25) & 2 (DN 50) 7RRR NOTE: lf complete disassembly becomes necessary; it is recommended to replace all seats and seals. Refer to the Repair Kit chart (see Table 3). NOTE: Always use original OEM parts to make sure that the valve functions properly. 8. Remove and discard the old body seal (6). BE CAREFUL NOT TO DAMAGE THE SEALING SURFACES. 9. With the ball in the closed position, remove ball (3) and seats (5). NOTE: A piece of wood or other soft material may be used to unseat the parts from the opposite side by gently tapping the ball from the end opposite the insert. BE CAREFUL NOT TO DAMAGE THE BALL OR SEATING SURFACES IN THE BODY. Figure 3 1 (DN 25) & 2 (DN 50) 7RRT 10. Press the stem (4) into the body (1) and remove it through the insert side of the valve. It may be necessary to tap it with a piece of wood or some other soft material. BE CAREFUL NOT TO DAMAGE THE STEM OR BODY SEALING SURFACES. 11. Carefully remove and discard the stem seal (8) and stem bearings (13) and secondary stem seal (7). BE CAREFUL NOT TO DAMAGE THE SEALING SURFACES. DAMAGING SEALING SURFACES WILL NEGATIVELY AFFECT VALVE SEALABILITY AND PERFORMANCE. 4.2 Disassembly Figure 4 2 (DN 50) 7RRU 1. Comply fully with ALL WARNINGS prior to working on the valve. 2. Open and close the valve and leave in the half open position. 3. Remove the handle nut (16), washer (19) and handle (17). 4. Remove cap screws (29), disc springs (31), and compression plate (20). 4.3 Checking Parts NOTE: For detailed instructions on visual inspection of critical components, refer to IMO-R26. 1. Clean all disassembled parts. 2. Check the stem (4) and ball (3) for damage. Pay particular attention to the sealing areas. 3. Check all sealing and gasket surfaces of the body (1) and insert (2). 4. Replace any damaged parts.

6 IMO-R21 EN NOTE: When ordering spare parts not included in the standard repair kits listed in Table 3, always include the following information: a. Valve catalog code from Identification plate, b. The serial number (stamped on the valve Identification plate), c. From Figure 8 or 9, the ballooned part number, part name and quantity required. 4.4 Assembly Refer to standard repair kit shown in Table 3 for replacement seats and seals. Apply a good lubricant compatible with the flow medium lightly to insert (2) and bonnet cap screws (29) threads to facilitate assembly. 1. Clean all valve parts, if not previously cleaned. 2. Inspect the parts to ensure sealing surfaces are in good condition and all parts are properly cleaned and prepared for assembly. Look for damage to the seating areas, body and insert. Check stem finish in the sealing area. If there are marks, use 600 or greater grit sand paper and polish circumferentially not up and down. Replace any damaged parts. 7. Holding the stem in place from the inside, install the stem seal (8) and the compression plate (20) over the end of the stem protruding out of the body stem bore as shown in Figure 8 or 9. 8. Place the disc springs (31) on the cap screws (29). Disc spring orientation shall be as shown in Figure 8 and 9. Insert cap scews (29) with springs into body and tighten finger-tight. 9. While pressing the stem (4) outward from inside the body, tighten the cap screws (29), apply torque evenly, alternating between the two nuts so that the compression plate will be parallel with the valve body. Rotate the stem gently to assure proper seating. 10. Tighten the cap screws (29) to the torque provided in (Table 2) (Hex head cap screw (29) torque). 11. Make sure there is no dirt and grit in the insert (2) threads. Apply a lubricant compatible with the flowing media to the threads and screw the insert (2) into the body (1) by hand until it is fully seated. Mark the position as shown in (Figure 6). Counting the number of turns, remove the insert. 3. Clamp the valve body (1) securely in a vise in the vertical position with the insert end up, taking care not to damage any valve sealing surfaces. 4. Place one valve seat (5) sidewise into the body cavity (1) to just below the stem hole and tilt it into place so that the proper face will come in contact with the ball (3) (see Figure 5). Figure 6 12. Align the stem (5) to the ball slot. Insert the ball (3) rotating it onto the stem (4) in the closed position. If necessary turn the stem blade to align with the ball slot. Figure 5 Seats should be in this position at Assembly. 5. Place the stem bearings (13) and secondary stem seal (7) on the stem (4) shown in Figure 8 or 9. 6. Insert the stem (4) with the bearings into the valve body and through the stem bore in the body, as shown in (Figure 2, 3 or 4). Press it gently up into the stem bore until resistance is felt from the lower stem bearing. Be careful not to scratch or damage the seals. 13. Insert the second seat (7) with the seat sealing surface towards the ball. (See Figure 5). 14. Insert the body seal (6) onto the insert (2). 15. Make sure there is no dirt and grit in the insert (2) threads. Using a thread lubricant compatible with the media, screw the insert (2) into the body (1) and tighten the insert. Insert must be tightened the same number of turns as in step 11, insuring that the marks are either lined up or insert mark is +/ 1/8 (Dimension A) either side of the body mark, as shown in Figure 7.

IMO-R21 EN 7 5. REPAIR KITS We recommend that valves be directed to our service center for maintenance. The service centers are equipped to provide rapid turnaround at reasonable cost and offer new valve warranty with all reconditioned valves. Standard Repair Kits (Table 3) include seats, seals, and stem bearings. 6. SERVICE/SPARE PARTS For further information or assistance on repair kits and spare parts visit our website at www.metso.com/valves. Figure 7 16. Install handle (17), lockwasher (19) on the stem (4), matching the flats on the stem and handle. The handle should be in the orientation as shown in Figure 2, 3 or 4 in the closed position. Thread handle nut (16) onto the stem and tighten per Table 2. 17. Cycle the valve slowly with a gentle back and forth motion to build gradually to the full quarter turn. A fast turning motion at this point may cut the seats before they have a chance to form the proper seal. NOTE: When ordering spare parts not included in repair kits, always include the following information: a. Valve catalog code from Identification plate, b. If the valve is serialized - the serial number (stamped on the valve body), c. From Figure 8 or 9, the ballooned part number, part name and quantity required. 4.5 Testing the Valve WHEN PRESSURE TESTING, EXERCISE CAUTION AND MAKE SURE ALL EQUIPMENT USED IS IN GOOD WORKING CONDITION AND APPROPRIATE FOR THE INTENDED PRESSURE. If the valve is to be tested prior to returning to service make sure the test pressures are in accordance with an applicable standard. When testing the valve for external tightness, keep the ball in the half open position. If testing the valve seat tightness, please contact Metso for advice. WHEN PERFORMING ANY TESTS, NEVER EXCEED THE MAXIMUM OPERATING PRESSURE OR MAXIMUM SHUT-OFF PRESSURE LISTED ON THE IDENTIFICATION PLATE!

8 IMO-R21 EN EXPLODED VIEW & PARTS LIST 16 19 17 26 23 29 31 20 8 ITEM NO. DESCRIPTION QTY. 1 BODY 1 2 INSERT 1 3 BALL 1 4 STEM 1 5 SEAT 2 6 BODY SEAL 1 7 SECONDARY STEM SEAL 1 8 STEM SEAL 1 13 STEM BEARING 2 16 HEX. JAM NUT 1 17 HANDLE 1 19 SHAKEPROOF WASHER 1 20 COMPRESSION PLATE 1 22 IDENTIFICATION PLATE 1 23 POP RIVET 3 26 HANDLE STOP 1 29 HEX. HEAD CAP SCREW 2 31 DISC SPRING 4 22 1 5 PROPER DISC SPRING ARRANGEMENT (UNCOMPRESSED) 3 5 6 2 13 7 13 4 1 (DN 25) & 2 (DN 50) 7RRR & 7RRT Figure 8

IMO-R21 EN 9 16 19 17 26 29 31 20 8 ITEM NO. DESCRIPTION QTY. 1 BODY 1 2 INSERT 1 3 BALL 1 4 STEM 1 5 SEAT 2 6 BODY SEAL 1 7 SECONDARY STEM SEAL 1 8 STEM SEAL 1 13 STEM BEARING 2 16 HEX. JAM NUT 1 17 HANDLE 1 19 SHAKEPROOF WASHER 1 20 COMPRESSION PLATE 1 22 IDENTIFICATION TAG 1 23 POP RIVET 3 26 HANDLE STOP 1 29 HEX. HEAD CAP SCREW 2 31 DISC SPRING 4 23 22 1 PROPER DISC SPRING ARRANGEMENT (UNCOMPRESSED) 5 3 5 6 2 13 7 13 4 2 (DN 50) 7RRU Figure 9

10 IMO-R21 EN TABLE 2 1 7RRR/7RRT 2 7RRR/7RRT 2 7RRU Insert (2) Torque 150 FT LBS (203 N m) 350 FT LBS (476 N m) 350 FT LBS (476 N m) Hex Head Cap Screw (29) Torque 20 IN LBS (2.3 N m) 32 IN LBS (3.6 N m) 32 IN LBS (3.6 N m) Handle Nut (16) Torque 23 FT LBS (31 N m) 33 FT LBS (45 N m) 33 FT LBS (45 N m) TABLE 3 Repair Kits Seat Material 1 7RRR/7RRT 2 7RRR/7RRT 2 7RRU Xtreme seats RKN-356XT RKN-359XT RKN-359XT PTFE seats RKN-356TT RKN-359TT RKN-359TT

IMO-R21 EN 11 HOW TO ORDER As the use of the valve is application specific, a number of factors should be taken into account when selecting a valve for a given application. Therefore, some of the situations in which the valves are used are outside the scope of this manual. If you have any questions concerning the use, application or compatibility of the valve with the intended service, contact Metso for more information. EXAMPLE: 1 7RRR valve with raised face, 316 stainless steel body and trim, Xtreme seats, stainless steel bolting. 1 2 3 4 5 6 1 7RRR 3600 XTZ 2 A 1 Valve Size 1 1 2 2 2 Series 7RRR ASME Raised face x ASME Raised Face 7RRT ASME Raised face x ASME Tongue 7RRU ASME Raised face x AAR Tongue (2 Only) 3 Valve Construction Body and Body Cap Ball and Stem 2235 Carbon Steel (WCB) Alloy 20 2236 Carbon Steel (WCB) Stainless Steel 316 3600 Stainless Steel 316 (CF8M) Stainless Steel 316 4 Seat/Seal Materials Seat Seals (Stem & Body) - Standard Fire-Tite TTT Virgin Teflon (PTFE) Virgin Teflon (PTFE) & TFM or PTFE XTZ Xtreme TFM & TFM or PTFE Bolting Material 5 Bolts Nuts 1 ASTM A193 Gr. B7 ASTM A194 Gr. 2H 2 ASTM A193 B8, B8C, B8M or B8T Class 2 6 Model A Model A ASTM A194 Gr. 8B, 8CB, 8MB, 8TB or 8FB

12 IMO-R21 EN Subject to change without prior notice. Metso Flow Control Inc. Europe, Vanha Porvoontie 229, P.O. Box 304, FI-01301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151 North America, 44 Bowditch Drive, P.O. Box 8044, Shrewsbury, M A 01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172 South America, Av. Independéncia, 2500-Iporanga, 18087-101, Sorocaba-São Paulo, Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748 Asia Pacific, 238B Thomson Road, #17-01 Novena Square Tower B, Singapore 307685. Tel. +65 6511 1011. Fax +65 6250 0830 China, 11/F, China Youth Plaza, No.19 North Rd of East 3rd Ring Rd, Chaoyang District, Beijing 100020, China. Tel. +86 10 6566 6600. Fax +86 10 6566 2583 Middle East, Roundabout 8, Unit AB-07, P.O. Box 17175, Jebel Ali Freezone, Dubai, United Arab Emirates. Tel. +971 4 883 6974. Fax +971 4 883 6836 www.metso.com/valves