Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Similar documents
Smart Trak. AU18, AU28, AU38, AU48, AV16, AV26, AV36, AV46, AZ18, AZ28, AZ38 & AZ48 Series Owner s Manual. w/ Compact Junction Box

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

Optic Level Switch LO10 Series Owner s Manual

LA19 Series Ricochet Battery Powered Level Transmitter and Display

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

Thermo Flo Thermal Dispersion Flow Switch FT10 & GT10 Series Manual

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

XP88 & XP89 Series Quick Start

Smart -Trak. AU23, AV23, AZ23 Series Manual. With Compact Relay Controller

LU27 Series Quick Start

LU23, LU28 & LU29 Series Quick Start

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

Switch Pro Remote Level Controller LC40, LC41 & LC42 Series Manual

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter

EchoPod. UG01 & UG03 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Switch, Controller & Transmitter

Switch-Tek. LZ12, LU10, LP15 and LO10 Series Manual. Powered Level Switch

Intrusive RF Capacitance Level Switch LP10 Series Owner s Manual Provided by:

INTRODUCTION / TABLE OF CONTENTS

Switch-Tek Powered Level Switches LZ10, LU10, LP15, LP10, and LO10 Series Owner s Manual

INTRODUCTION / TABLE OF CONTENTS

EchoSonic. LU23, LU27, LU28 & LU29 Series Manual. Ultrasonic Liquid Level Transmitter

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

CDS-JOHN BLUE COMPANY

MAXIGARD A2000 SPEED SWITCH. Introduction

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

CDS-JOHN BLUE COMPANY

EchoPod DL14, DL24 & DL34 Series Manual Revision A.3

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Switch-Tek Powered Level Switches LZ12, LU10, LP15, LP10, and LO10 Series Owner s Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

MS40 MS40/EX Explosion

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

1 2-Inch Station Outlet Valves

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

INSTALLATION AND OPERATION MANUAL

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

Broadband PowerShield. CP27U Models. User Manual

PARTS AND INSTALLATION MANUAL

INSTALLATION DATA MANUAL Model 510 Pressure Transmitter

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Installation and Operating Manual

CDS-JOHN BLUE COMPANY

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

PVI 60KW, PVI 82KW, PVI 95KW

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

G8 Portable Fuel Transfer Pump Owner s Manual

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

TABLE OF CONTENTS. Page 1

To order call or visit -

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

BMRX Series ROTARY LEVEL CONTROL

MS Rev c ( ) DCN0530

Full View Flow Indicator

Effective June 1, 2013 This guide supersedes all previous versions

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Owner s Manual & Safety Instructions

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

A Member of the. Integrated Metering Technologies

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

A Member of the. Integrated Metering Technologies

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

25 GALLON PORTABLE OIL LIFT

Installation & Operators Manual

DC to DC Step Up Converter Model: VTC305

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

EchoPod. DL10, DL14, DL24, DL34, DS14, DX10 Series Manual. Ultrasonic Liquid Level Transmitter, Switch and/or Controller

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Motorized Stainless 2-Way Valves

10 S e r i e s PRESSURE SWITCH. features

MULTIPOSITION AIR CYLINDER

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

A5000GEC-24VDC ZERO SPEED SWITCH

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

BroadBand PowerShield. 20 AHr Battery. User Manual

CRD400 Fitting Inserter OPERATIONS MANUAL

Transcription:

Warranty, Service & Repair To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows: www.flowline.com On-line Warranty Registration can be found under Contact Us in the Navigation Bar along the side of the home page. If for some reason your product must be returned for factory service, contact Flowline Inc. at (562)598-3015 to receive a Material Return Authorization number (MRA), providing the following information: 1. Part Number, Serial Number 2. Name and telephone number of someone who can answer technical questions related to the product and its application. 3. Return Shipping Address 4. Brief Description of the Symptom 5. Brief Description of the Application Once you have received a Material Return Authorization number, ship the product prepaid in its original packing to: Flowline Factory Service MRA 10500 Humbolt Street Los Alamitos, CA 90720 To avoid delays in processing your repair, write the MRA on the shipping label. Please include the information about the malfunction with your product. This information enables our service technicians to process your repair order as quickly as possible. Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual Version 0.3A 2006 FLOWLINE Inc. All rights reserved. Manual # LM900007 06/06 WARRANTY Flowline warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service for a period which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products. This warranty covers only those components of the products which are non-moving and not subject to normal wear. Moreover, products which are modified or altered, and electrical cables which are cut to length during installation are not covered by this warranty. Flowline s obligation under this warranty is solely and exclusively limited to the repair or replacement, at Flowline s option, of the products (or components thereof) which Flowline s examination proves to its satisfaction to be defective. FLOWLINE SHALL HAVE NO OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSON- AL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON. This warranty does not apply to products which have been subject to electrical or chemical damage due to improper use, accident, negligence, abuse or misuse. Abuse shall be assumed when indicated by electrical damage to relays, reed switches or other components. The warranty does not apply to products which are damaged during shipment back to Flowline s factory or designated service center or are returned without the original casing on the products. Moreover, this warranty becomes immediately null and void if anyone other than service personnel authorized by Flowline attempts to repair the defective products. Products which are thought to be defective must be shipped prepaid and insured to Flowline s factory or a designated service center (the identity and address of which will be provided upon request) within 30 days of the discovery of the defect. Such defective products must be accompanied by proof of the date of purchase. Flowline further reserves the right to unilaterally wave this warranty and to dispose of any product returned to Flowline where: a. There is evidence of a potentially hazardous material present with product. b. The product has remained unclaimed at Flowline for longer than 30 days after dutifully requesting disposition of the product. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and liabilities of Flowline under it are exclusive and instead of, and the original purchaser hereby waives, all other remedies, warranties, guarantees or liabilities, express or implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTIC- ULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF MERCHANT ABILITY OF THE PRODUCTS. This warranty may not be extended, altered or varied except by a written instrument signed by a duly-authorized officer of Flowline, Inc.

SPECIFICATIONS Step One Specifications: Switch point: 1 (set by factory) Orientation: ± 20 horizontal Process temp.: F: -40 to 194 C: -40 to 90 Pressure: AU1_: 150 psi (10 bar) AZ1_: 150 psi (10 bar) Wetted material: AU15: PP / PFA AZ18: PP-Ryton Process mount: 3/4 NPT (3/4 G) Enclosure rating: NEMA 4X (IP65) Encl. material: PP, UL94VO Conduit entrance: Single, 1/2" NPT Termination: 2-4 poles CE compliance: EN 61326 EMC EN 61010-1 safety Dimensions (w/ ultrasonic sensor): 2.8" (71 mm) 3/4" NPT (3/4" G) 2.3" 2.1" (57 mm) (54 mm) 2.8" (71 mm) 2.8" (71 mm) 7.5" (191 mm) Sensor Technologies: Ultrasonic (LU10 series) Broadly applied in chemical, solvent, hydrocarbon and light weight oil media Supply voltage: 12-36 VDC Consumption: 25 ma maximum Contact type: (1) SPST relay Contact rating: GP: 120 VAC/VDC @ 1A IS: 32 VDC @ 0.5A Contact output: Selectable NO/NC Classification: Intrinsically safe Vibration (LZ12 series) Typically applied in wastewater media with light coating and/or foaming characteristics Supply voltage: 12-36 VDC Consumption: 25 ma maximum Contact type: (1) SPST relay Contact rating: 120 VAC/VDC @ 1A Contact output: Selectable NO/NC Classification: General purpose Dimensions (w/ vibration sensor): 2.8" (71 mm) 3/4" NPT (3/4" G) 2.3" 2.3" (57 mm) (57 mm) 2.8" (71 mm) 3.0" (76 mm) 7.7" (196 mm)

COMPONENTS Step Two Standard Configuration: AU15-113_ or AU15-213_ AZ18-113_ AU15-1130 1 x LU10-1405 1 x LC06-1001 Ultrasonic AU15-2130 1 x LU10-2405 1 x LC06-1001 AZ18-1130 1 x LZ12-1405 1 x LC06-1001 Vibration AZ18-1134 1 x LZ12-1425 1 x LC06-1051 AU15-1134 1 x LU10-1425 1 x LC06-1051 AU15-2134 1 x LU10-2425 1 x LC06-1051 Component List: Compact Relay Controller P/N: LC06-1001 or LC06-1051 Switch-Tek Level Switch P/N: LU10-1405, LU10-1425, LU10-2405, LU10-2425 Switch-Tek Level Switch P/N: LZ12-1405 or LZ12-1425

SAFETY PRECAUTIONS Step Three About this Manual: PLEASE READ THE ENTIRE MAN- UAL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on the Switch Pro with Compact Junction Box: AU15-_13_ and AZ18-113_. The units are identical except for the material of construction and the sensors technology. User's Responsibility for Safety: Flowline manufactures a wide range of liquid level sensors, controllers, and mounting systems. It is the user's responsibility to select components that are appropriate for the application, install them properly, perform tests of the installed system, and maintain all components. The failure to do so could result in property damage or serious injury. Proper Installation and Handling: Use a proper sealant with all installations. Never overtighten the components. Always check for leaks prior to system start-up. Material Compatibility: Polypropylene (PP, a polyolefin): Sensor, Junction Box. Perfluoroalkoxy (PFA, Teflon ): Sensor (AU15-213_ only). Ryton (glass filled): Vibration Sensor Only. Make sure that the application liquids are compatible with the materials that will be wetted. To determine the chemical compatibility between the components and its application liquids, refer to the Compass Corrosion Guide, available from Compass Publications (phone 858-589-9636). Temperature and Pressure: Switch Pro is designed for use in application temperatures up to 90 C (194 F). The Vibration and Ultrasonic packages are designed for pressurized applications up to 150 psi (10 bar). Wiring and Electrical: Electrical wiring of any liquid level control system should be performed in accordance with all applicable national, state, and local codes. Take care not to cut or break the outer insulation jacket of wiring that may be immersed while routing cables in the Switch Pro system. Such breaks of the liquid seal of the sensor system may lead to component failure. Flammable, Explosive and Hazardous Applications: Switch Pro may be used within flammable or explosive applications only if the associated components are rated intrinsically safe for such use. In hazardous applications, use redundant measurement and control points, each having a different sensing technology. ASSEMBLY OF SWITCH PAK Step Four About Switch Pro : Flowline s Switch Pro with Compact Junction Box Assembly is an single-point mounting system for installing one level sensor horizontally within a tank. The compact junction box features termination for the various wires from each level switch as well as a 1/2 conduit connection. Switch Pro mounts horizontally through a standard 3/4" NPT fitting. Level Switches: Switch Pro includes a single level switch used to identify it s own unique wet / dry condition. The technologies used to indicate level are either Ultrasonic or Vibration. Each technology features a unique wiring/power configuration (Ultrasonic and Vibration technologies require 12 to 36 VDC power for operation, see below). The switch is terminated in the Compact Junction Box. The Compact Junction Box provides a 1/2 Conduit connection and 6 poles for wire termination. Vibration (LZ12-1405 or LZ12-1425) Wire Configuration: Red Black White Green Orange RELAY (+) (-) N/A N/A N/A Shld Compact Junction Box (inside shown) Ultrasonic (LU10-_405 or LU10-_425) Wire Configuration: RELAY Red (+) Black (-) White N/A Green N/A Shld Make a Fail-Safe System: Design a fail-safe system that accommodates the possibility of system or power failure. In critical applications, Flowline recommends the use of redundant backup systems and alarms in addition to the primary system.

INSTALLATION Step Five Through Wall Installation: Flowline s Switch-Pro A_1_ Series may be installed through the side wall of a tank. The sensor has male 3/4" NPT (3/4 G) threads on one side of a 15/16" wrench flat. This enables the user to select the sensor s mounting orientation, installed outside of the tank in. Ultrasonic Orientation: Install the switch such that the gap is aligned up and down, allowing for liquid to easily leave the gap. Avoid aligning the gap horizontally. This could allow material to collect on one of the flat surfaces in the gap. See the illustrations below for further information. WIRING Step Six Ultrasonic and Vibration Switches (LU10-1305, LU10-1325, LZ12-1405, LZ12-1425): The LU10-13_5 and LZ12-14_5 switch can be wired normally open or normally closed for your application requirement. Each switch requires 12-36 VDC power to operate the sensor and switch the relay. The relay output can be wired as a dry contact. All illustrations below identify a Dry switch state as the normal position of the relay. Switching a Normally Open DC Load: The Red wire connects to Positive (+) of the power supply and the Black wire connects to Negative (-). The can be attached to either the Green or White wires. Complete the circuit by either connecting the Green to (+) VDC power or White to (-) VDC power (see illustration below). [Dry Condition] Vibration Orientation: Install the switch such that the forks are aligned up and down, allowing for liquid to easily leave the space between the forks. Avoid aligning the gap horizontally. This could allow material to collect on one of the forks. See the illustrations below for further information. Do not squeeze the forks together. Doing so could damage or break the sensor and void the warranty. Sensor (NO) RED GRN SHLD WHT BLK Switching a Normally Closed DC Load: The Black wire connects to Positive (+) of the power supply and the Red wire connects to Negative (-). The can be attached to either the Green or White wires. Complete the circuit by either connecting the Green to (+) VDC power or White to (-) VDC power (see illustration below). OR [+] [-] [Dry Condition] BLK GRN SHLD WHT RED [+] Sensor (NC) OR [-] Maintenance Alarm (LZ12 Vibration only): For optimum performance and proactive maintenance, the sensor automatically adjusts for coating, and if necessary, outputs a preventative maintenance alarm. The Orange wire is a NPN transistor designed to switch when a build-up of material prevents the vibration switch from operating at its operational frequency. Use the Orange wire to identify when the Vibration switch requires cleaning (see the LZ12 manual for wiring information).

MAINTENANCE Step Seven Step Eight General: The Switch Pro with Compact Junction Box requires no periodic maintenance except cleaning as required. It is the responsibility of the user to determine the appropriate maintenance schedule, based on the specific characteristics of the application liquids. Cleaning Procedure: 1. Power: Make Sure that all power to the sensor, controller and/or power supply is completely disconnected. 2. Sensor Removal: Make sure that the tank is in a state where it is safe to remove the sensors. Carefully, remove the Switch Pro from the installation. 3. Cleaning the Sensor: Use a soft bristle brush and mild detergent, carefully wash the Switch Pro. Do not use harsh abrasives such as steel wool or sandpaper, which might damage the surface sensor. Do not use incompatible solvents which may damage the sensor's PP or Ryton plastic body. 4. Sensor Installation: Follow the appropriate steps of installation as outlined in the installation section of this manual. Testing the installation: 1. Power: Turn on power to the switches and/or power supply. 2. Immersing the switch: Immerse the sensing tip of each switch in its application liquid, by filling the tank up to the switches point of actuation. An alternate method of immersing the switch during preliminary testing is to hold a cup filled with application liquid up to the switch's tip. 3. Test: With the switch being fluctuated between wet and dry states, the switch will open or close depending on wiring status. If the system doesn't have an input indicator, use a multimeter to ensure that the switch produces the correct signal. Current Test (Ultrasonic and Vibration only): Used to verify if the sensor is indicating a wet or dry condition. This test uses only two wires (Red and Black). The sensor draws 5 ma (ultrasonic) or 8 ma (vibration) when it is dry, and 19 ma when wet. The White and Green wires are not used. Red + - 24 VDC Power Supply Black - + Multimeter (ma)