Extraction arm FX100 Original

Similar documents
BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2 100 Original

BenchTop Extraction Arm FX2

Bench Top Extraction Arms

BenchTop Extraction Arm FX2

LOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.

Mini Arms 4" Diameter

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

NCF fans 50 Hz. Protection class IP 55

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

4m. Extension arm. HVU Arm. ASX ATEX arm. HVU Arm

Extraction arms for every type of application

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

FlexPAK 800 DX. The leading extraction solution. Always the right capacity.

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

ALSIDENT SYSTEM 50. A small flexible extraction arm

Exhaust rail system 920 for stationary vehicles

FTM-TECHNOLOGIES : 78, rue Raymond Poincaré Nanterre FRANCE Tél Fax:

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

For installation into ductwork

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

BenchTop Extraction Arm FX2

NCF 60 Hz. Protection class IP 55

Exhaust rail system 920 for stationary vehicles

Manual Use and Maintenance ALSIDENT SYSTEM 75

NCF fans 60Hz. Protection class IP 55

Ventilation grilles for installation into walls, sills or rectangular

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information

Ventilation grilles for installation into walls, sills or rectangular

Fume Arms. AQC source capture equipment. Superior technology generating substantial operating savings. No internal adjustment

FilterMax F. Modular dust collector with integrated pre-separator. Models

Exhaust Extraction Systems for Stationary Vehicles

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

STANDARD VENTILATION UNIT (VK)

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

Exhaust Nozzles. High temperature resistant rubber and metal exhaust hoses

Tubular Centrifugal Fans

J L I e x h a u s t h o o d

SYSTEM10. Airflow Alarm

FilterMax F. Modular dust collector with integrated pre-separator

FilterMax DF. Modular dust multi purpose collector. Models

Ceiling swirl diffusers

Fume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment

FilterMax F. Modular dust collector with integrated pre-separator

Extraction Arms. Capturing fumes at the source

FILTER Pure advantage. A flexible modular filter for particles and gas

FilterMax DF. Modular dust multi purpose collector. Models

Volume Extraction Extraction Units

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Products, systems and solutions for improved workplaces 2009/2010

LCP Cartridge Dust Collector

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

FlowAir CATALOG.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

WALL VENTILATION GRILLES CBP

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

Tube Axial Inline Fans

Pneumatic Rail System (PRS)

Inline Fans [ 14 ] * UL is optional and must be specified.

Ceiling swirl diffusers with perforated face plate

15000 TT Series Tube Type

Catalog Swirl diffuser DAL 358

Fume cupboards and extraction devices

Medium Pressure Centrifugal Fans

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

Fume extractor is warranted for two years, parts and labor.

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Roof Upblast and Sidewall Exhaust

Ceiling swirl diffusers with perforated face plate

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

ACTIVENT System. Specifications. Product code example ACTA

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

2007 /

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

EXHAUST EXTRACTOR Pure advantage. Exhaust rails for rescue vehicles

Ceiling swirl diffusers

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES

Splash-proof Terminal HEPA Filter

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

SMART Application Structure Acoustics s n fa f o o R

1 of 8. Air Solutions Sdn. Bhd. Euro Carb. Box Type Chemical Filter

EXTRACTION ARMS. Capturing fumes at the source

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

Transcription:

Bench top extraction systems for all environments. The Nederman bench top systems can be used in every type of environment, from assembly stations, where soldering fumes are extracted, to laboratories, where protection against highly corrosive or noxious gases is vital. Bench top extraction systems are available both as complete packages and as individual components. A customised bench top extraction system consists of an extraction arm always with a mini hood (universal interface for other hoods), completed with different accessories such as brackets, extension arm, reducers, hoses etc. These parts are ordered separately. A bench top extraction system can be connected to a single extraction fan filter N3, or to a central extraction fan/filter. Unique maneuvrability with 360 rotation Optimal efficiency and low noise Ceiling, wall, floor or bench mounting Damper included Product name Noise level (db(a)) Installation Material Extraction arm FX100 Original 62 db(a) at 450 m3/h Indoor Aluminium, anodized. Joints in PP. Fume temperature Max 70 C (158 F) Extraction arm diameter (in) 4 Airflow (cfm) 265 www.nederman.com 1 8/17/2017

Description Arm length (ft) Weight (lbs) Model FX Ø100 Original, Connection double 3ft11in 11 70570144 FX Ø100 Original, Connection up 6 13 70570344 FX Ø100 Original, Connection up 8 15 70570544 www.nederman.com 2 8/17/2017

Accessory Part No FX-Bracket kit-d50/75/100-l190. Complete mounting kit, with the classic bracket,190 mm (7.48 inch) extension profile and associated parts, for mounting FX2 50/75/100 arms with 250mm from the vertical centre line of the arm to the wall FX-Classic bracket-d50/75/100. The classic bracket should be used together with Cut2fit extension profile for mounting FX2 50/75/100 arms on the ceiling, wall, floor or on top of other horizontal surface. FX-Cut2fit extension-l1100. Cut2fit extension could be cut at any length and should be assembled together with the classic bracket for mounting FX2 50/75/100 arms on the ceiling or wall. FX-Cut2fit extension-l2200. Cut2fit extension could be cut at any length and should be assembled together with the classic bracket for mounting FX2 50/75/100 arms on the ceiling or wall. 70501144 70501244 70501344 70374600 FX2-Bench bracket kit-d50/75/100, Complete mounting kit for mounting FX2 50/75/100 arms on the bench edge. 70501444 FX-Ceiling cover plate. Cover false/dropped ceiling openings caused by both extension profile and ducting. 70502644 Support collar 70502744 FX-Combi hood-original-d50/75/100. Transparant combi hood, made of PET-G plastic, arms is designed to capture contaminants with low energy. It can be attached directly on minihood, irrespective of arm size. The ergonomics of handle design on both sides of the hood make it easier to maneuver. FX-Metal hood-orig/chem-d50/75/100. Powder coated white metal hood, made of aluminum, is designed to capture contaminants in high temperature, aggressive fume where corrosion resistance must be assured or dust splatter. It can be attached directly on minihood, irrespective of arm size. FX-Flange hood-original-d50/75/100. Transparent flange hood, made of PET-G plastic, is designed to maximize the capture zone without hinder objects on the bench or the user. It can be attached directly on minihood, irrespective of arm size. FX-Dome hood-original-d50/75/100. Transparent dome hood, made of PET-G plastic, is designed to capture high dispersion contaminants. It can be attached directly on minihood, irrespective of arm size. The ergonomics of handle design on both sides of the hood make it easier to maneuver. 70500144 70500444 70502844 70376982 Reduction Kit Ø100 70500844 Reduction Kit Ø125 70500944 www.nederman.com 3 8/17/2017

Sound level X: airflow m³/h, Y: Sound level (db A) Pressure Drop X: airflow m³/h, Y: static pressure Pa Position of arm when measured Pressure Drop www.nederman.com 4 8/17/2017

Measures and Model number Note: Different spring mechanism are fitted depending on connection direction FX arms, connection Down. Floor mounted and Bench mounted FX arms, connection Up. Wall mounted and Ceiling mounted Connection Directions 1) FX arm with ventilation connection downwards 2) FX arm with ventilation connection upwards www.nederman.com 5 8/17/2017