Wiper Switch. For one Exalto H.D. wiper. Cat. no Quality Marine Equipment

Similar documents
Electronic Wiper Control

Electronic Wiper Control

Exalto Wipercontrol. For 2 to 5 wipers. Cat.no.: Quality Marine Equipment

Users manual for. Wiper Control. Imtra Corporation 30 Samual Barnet Boulevard New Bedford MA 02745, U.S.A. Part No.: EX210604

Exalto windshield wiper

External wiper housing

Exalt windshield wiper

User manual for. Exalto windshield wiper Type 223 BD 12/24 Volt

User manual for Exalto windshield wiper Type 223 BS 12/24 Volt

Exalto windshield wiper type 235 KK-HD 12/24 Volt

User manual for Exalto windshield wiper Type 233 BD 12/24 Volt. Cat.no /32/35/40/45/50 (12 Volt) Cat.no /32/35/40/45/50 (24 Volt)

DECCA. Heavy duty straight line wipers FOR ALL SHIP CATEGORIES

2D-1. Double Driver Wiper System. Presenting the latest in single-motor, double-driver wiper technology. ,Ff- PANTOGRAPH

Marinco Heavy Duty Plus Wiper Systems

The company 4. CM Series Engine Control Panel 6 CM 40 Series CM 20/30 Series CM 2A/3A Series CM 02 Series CM 60 Series

The modular structure makes it possible to build at least 5 configurations for each visual lens unit

User Manual. DECCA Heavy Duty Straight Line Wipers Thor Control System.

REDUCER BAT/17277: 10/6 T CONNECTORS BAT/17356: 10/10/10 BAT/16295: 10/6/10 BAT/17354: 6/10/6 BAT/21764: 6/6/6 WASH LOCKER

Timer Relays - Fixed & Adjustable

Smart Battery Charger

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

Handbook for. System D2NA

DKG-114 MANUAL AND REMOTE START UNIT

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

INSTRUCTION AND USE MANUAL

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

ThunderION. Static Neutralising System. GB User's Manual 2

IQL Helios Area-/Streetlight. User Manual

ACTUATORS POSITION SENSOR

Car Alarm System PCI0768/A

Battery Charger JCB-FCH20LI2

The WDS A Dimmer Users Manual Rev , 2012 City Theatrical, Inc.

Table of Contents. For latest version, visit:

PowerLevel s e r i e s

EQUIPMENT - MAIN BODY 7-1 SECTION 7 EQUIPMENT CONTENTS

INSTALLATION MANUAL (cod )

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

DC Master 24/ A

ECONOMISER SERIES E2T USER MANUAL

User Manual. (English)

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

c-go 24V/6A 24V/8A 24V/12A

M OTO R. The electric motor. DC - direct current voltage.

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

MOTOR. The electric motor. DC - direct current voltage.

Installation & Calibration

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

SMX 22, SMX52 & SMX 102 Installation and Operating Guide

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Tina 4A Connection block

Prewired position switches FF series

FMC-1/2 Tina Muting unit

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Tina 11A Connection block

CS-865RKE Series II REMOTE KEYLESS ENTRY SYSTEM

Installation instructions. Adapter AD 01 AD 02 AD 03

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

PCB & DRIVER LED SOLUTIONS

IFD AIR CLEANER SERVICE MANUAL

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

User Manual of Lead Acid Smart Fast Charger (6 A) for 48V Lead Acid Battery 6Ah- 60Ah (110V Only, Standard Female Tamiya plug)

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

LED Flasher. R1 R2 100 F + C1 100 F +

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

BOVIBOOSTER WDone & WDtwo

EA07. Generator Automatic Voltage Regulator Operation Manual

Transformers for Low-voltage Halogen Incandescent Lamps

Flaming River Ind. 800 Poertner Dr Berea, OH FR1057 Watch Dog Automatic Battery Disconnect Switch

GENERALITIES TECHNICAL FEATURES

CruzPro. Volts Amps Amp-Hour Monitor VAH110. Other CruzPro Products. website:

Max. 30A 2 Coils Normal Open Contact Type. Positive Car : Ground, or. Max. 20A 2 Coils Normal Open Contact Type. Battery. Positive Car : Ground, or

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

CARM INTERNATIONAL TOWING MODULES

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Capacitive level sensors CLS 23

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

smart irrigation solutions

The specifier s dream... the installer s delight

W I P E R S Y S T E M S

Reliable Electric Actuation for Industrial Control

CAUTION CM-SE CM-S21 CM-S41

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Declaration of Conformity

AUTO GLIDE INSTALLATION GUIDE MANUAL A

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES

DUAL BATTERY SYSTEMS SOLENOID ISOLATOR ELECTRONIC ISOLATOR DIODE ISOLATOR. A simple and cost effective method of installing a dual battery system.

Visit us at

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Switches Unlimited Contact: Phone: * Fax:

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Transcription:

Wiper Switch For one Exalto H.D. wiper Cat. no. 210341 Quality Marine Equipment

Contents 1 General... 4 1.1 Functions... 5 1.2 General description... 5 1.3 Power supply..................................................... 5 1.4 Technical specifications... 5 1.5 Declaration of conformity... 5 2 Installation... 6 2.1 Dimensions... 6 2.2 Installation... 6 3 Electric connections... 7 3.1 General lay out... 7 3.2 Wiring diagram... 8 4 Operation... 9 4.1 Functions of the push buttons... 9 4.2 ON/OFF switching... 9 4.3 Signal mode... 9 4.4 Wipe/wash program...10 5 Failure.... 11 5.1 Continuous flashing signal... 11

1 General 1.1 Functions Brief explanation of buttons and LED s. Please see section 4 for complete operating instructions. 1 2 3 Pos. Function 1 Main ON/OFF switch. 2 Increase speed/decrease time between strokes. 3 Decrease speed/increase time between strokes. 4

1.2 General description The 210341 is a micro-controller based intelligent switch for operating one Exalto H.D. wiper motor. It provides all the functions for a proper windscreen cleaning. It consists of a touch pad with 45 cm (17 ) connection cable. This wiper control offers: two continuous speeds three intermittent speeds perfect self parking due to dynamic brake wipe/wash program dimmer input Visual indications for: ON continuous and intermittent modes 1.3 Power supply This wiper control is available to operate under a power supply of 12 or 24V DC. Check the power supply of the unit supplied, before connecting it to the ship s electric system. 1.4 Technical specifications Power supply: 10-30V DC Internal fuse: 4A PTC Stand-by current: less than 20mA Motor output current: single or double speed 4A max. Working temperature: -10 to +50 C Storage temperature: -20 to +70 C Inputs: 1 parking signal, open in park pos. Outputs: 1 slow speed 1 high speed 1 wash pump/solenoid, positive pole 1.5 Declaration of conformity This wiper control complies with the European requirements for electromagnetic compatibility, as required from 89/366/EEC, 73/23/EEC and EN60945 directives. 5

2 Installation 2.1 Dimensions 67,5 11,5 36,5 49,5 11,0 91,0 21,0 24,0 All dimensions in mm. 2.2 Installation The touch pad is to be fitted at a location that is within reach of the helmsman, allowing ease of operation. Make sure that sufficient room is available for the cables and the connectors. The required mounting hole for the touch pad is 36.5 x 21 mm. There should be at least 100 mm space available under the front of the touch pad for the connection cable and plug. Please make sure you insert the connector (linked to the wiper motor) before connecting the power supply! 6

3 Electric connections 3.1 General lay out Wash Fast Slow + Power Supply Park M Park Slow Fast M M 5A (Recommended) Wash + 7

3.2 Wiring diagram Colour code and connection of wiring coming from the 210341 controller: Green is to be connected to the Self Park (53a) of the motor wire. Blue is to be connected to the Negative (31b) and Common leg (53e) of the motor wire. Yellow is to be connected to the Low Speed (53) of the motor wire. White is to be connected to the High Speed (53B) of the motor wire. Brown is to be connected to a pump or solenoid. Always refer to the User Manual as supplied with the Exalto Wiper before connecting the Exalto wiper to the wiper switch. Female plug Male plug Red Black Brown Green White Yellow Blue Battery + Battery Pump/Solenoid 53a = Self Park 53b = High Speed 53 = Low Speed 53e = Common Leg 31b = Negative To wiper motor Battery 12 or 24 Vlot 8

4 Operation 4.1 Functions of the push buttons All push buttons have a double function as described in the chart (see paragraph 4.3). 4.2 ON/OFF switching By pressing button 1 or 2, the wiper can be switched on. By pressing button 1, the wiper will stop; in the park position. 4.3 Signals mode The three LED s shows the controller operation setting. By pressing any button, the mode will change and the LED s: will flash as many times as the delay times (in seconds) between the wiper strokes. (If 4 seconds is the delay times between the wiper strokes, the LED will flash 4 times.) will have a light flash slowly if Slow speed is selected and quickly is Fast speed is selected. Mode LED ( = on) Signal FAST speed Fast slight blink SLOW speed Slow slight blink 2 sec. delay 2 slow blink 4 sec. delay 4 slow blink 8 sec. delay 8 slow blink OFF LED s OFF Wipe/wash Failure Asymm. Continuous 9

4.4 Wipe/wash program This wiper control has a built-in smart wipe/wash program. The program is as shown below. 3 seconds 4 seconds 3 seconds Spray Wipe Spray Wipe Change settings: to increase wash time or the spray/wipe time, keep button 1 or 2 pressed. After the wash program has ended, the wiper will return to the wipe setting that was previously used. 10

5 Failure 5.1 Continuous flashing signal A continuous flashing signal indicates that the 210341 does not receive a parking switch signal. This may occur if: parking switch is damaged or disconnected; motor does not run (damaged or disconnected); 10-pin connector has been inserted after power supply and control works as with one speed motor. 11

Exalto B.V. P.O. Box 40 3370 AA Hardinxveld-Giessendam The Netherlands T +31 (0)184 615 800 F +31 (0)184 618 200 E wipers@exalto.com I www.exaltowipers.com Exalto B.V. April 2009