MEDIUM VOLTAGE NETWORKS

Similar documents
HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

Energy Division. PCA Single Column Polymeric Surge Arrester

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Surge arresters Product overview

GENERAL. CONSTRUCTION External

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

Surge arrester POLIM-H..SD

3EQ Composite Housed Surge Arresters

Surge arrester POLIM-H.. ND

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

3EK7 Distribution Class Surge Arresters. Answers for energy.

Bowthorpe EMP LV/MV Outdoor Surge Arresters

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

3EK7 Distribution Class Surge Arresters. Answers for energy.

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

Zinc Oxide Surge Arrester PEXLIM Q

Surge arrester POLIM-C.. HD

Zinc Oxide Surge Arrester EXLIM R

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

DynaVar Arresters IEC Line Discharge Classes 2, 3, 4 & 5

Surge arrester POLIM-H..N

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Shielded surge arresters

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arrester 3EL2 superior protection up to 550 kv

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

High Voltage Surge Arresters Buyer s Guide Section PEXLIM R

Voltage limiting device HVL

Station Class Polymeric Surge Arresters

Zinc-Oxide Surge Arrester TEXLIM Q-C

Disconnectors and earthing switches up to 25 kv AC

3EP6 porcelain surge arrester

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

Voltage limiting device HVL

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Directly Molded Polymer Surge Arresters

GE TRANQUELLTM Surge Arresters

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

High Voltage Surge Arresters Station Class

Neutral section. Features. Sicat 8WL5545-4D/4F for overhead contact line systems. siemens.com/rail-electrification

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

GE TRANQUELL Surge Arresters

ABB Switzerland Ltd Phone Surge arresters Telefax:

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

UltraSIL polymer-housed VariSTAR surge arresters 5 ka and 10 ka Class 1 IEC for MV systems to 36 kv

Surge Arresters. UltraSIL Housed VariSTAR Surge Arresters 5 ka and 10 ka Class 1 IEC for MV Systems to 36 kv FEATURES.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Independent Testing Laboratory for High Voltage Equipment

AIR CORE REACTORS. Phoenix Electric Corporation

NXPLUS C Single busbar. Maintenance-free for lifetime

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Technical Specification

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

5 SPECIAL CRIMPING TECHNOLOGY

UltraSIL polymer-housed VariSTAR station-class surge arresters

Transmission Porcelain Surge Arresters

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Technical specifications for 10 ka, heavy-duty class 1, 3 kv and 3.33 kv VariSTAR MOV disks

Technical specifications for 10 ka, heavy-duty class 1, 4.5 kv and 5 kv VariSTAR MOV disks

High Voltage Surge Arresters Buyer s Guide Section PEXLIM P-Y

power cable accessories

ENERGY /// TRANSMISSION LINE SURGE ARRESTERS IEC. Bowthorpe EMP Transmission Line Surge Arresters (IEC)

OHIO BRASS AIKEN, SC, USA

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

a Nexans company Catalogue 2008

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

Surge Arresters. Supply Program. Answers for energy.

EE 741 Over-voltage and Overcurrent. Spring 2014

Medium-voltage surge arresters. Product guide. Version Catalogue HG siemens.com/energy/arrester

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Optima Distribution Class (PDV) and Riser Pole (PVR) Surge Arresters

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

TECHNICAL DESCRIPTION

TEKNISK RIKTLINJE TR05-10E

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

INSTRUCTION MANUAL CRS Combined insulation bushing

55 Series - Miniature General Purpose Relays 5-10 A

شركة كهرباء محافظة القدس المساهمة المحدودة

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Surge-Trap Pluggable STPT2 Series - 40kA

COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS

Company main topic [ Product ] TracFeed STR. English. Section Insulators. Made in Germany

LIGHTNING EQUIPOTENTIAL BONDING ISOLATING SPARK GAPS. EXFS L / EXFS KU for explosive Areas

Transcription:

MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP

OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc oxide varistor arresters and composite insulators. OUR PRODUCTS DERVASIL presents : A comprehensive range of latest generation arresters: - 5 ka or 10 ka arresters with fault indicators or disconnector. - Arresters for cutting off power follow currents. - Arresters for D.C. These arresters do not have any internal spark gaps. They have very stable characteristics, practically constant and very short response times (30 to 50 nanoseconds). The directly moulded silicone housing provides both absolute sealing, exceptional resistance to pollution and a non-dangerous character in case of short-circuits. They are tested according to the latest version of the publication IEC 60099-4. A new range of composite insulators, suspension insulators, anchoring insulators and support insulators. Fault indicators and surge counters for maintaining and monitoring arresters. OUR R & D RESOURCES DERVASIL has computing resources and test equipment for designing medium arresters and insulators. Our experience is available to customers for specific applications. QUALITY SYSTEM DERVASIL is a certified company ISO 9001 and ISO 14001. Our production unit is approved by EDF and integrates all the equipment required for the routine tests required by the publications IEC 60099-4, IEC 61109 and IEC 61952.

USER GUIDE OVERVOLTAGES ON DIRECT CURRENT RAILWAY NETWORKS On these networks, the switching overs are generally very energetic and the temporary overs are frequent and long. The direct current power supply also imposes an additional stress. The AZE range was specially designed for this use and the leakage is highly increased to the high pollution generated by the friction of pantograph on the catenary. The varistors are designed to the continuous DC. The model can be selected using the table below: Nominal Voltage (V) Highest continuous Umax 1 (V) Highest over of duration 300 s Umax 2 (V) Highest over of duration 20ms Umax 3 (V) Recommanded AZE arrester 500 700 650 850 AZE 010T 600 720 800 1010 AZE 010T 750 900 1000 1270 AZE 010T 800 960 1050 1350 AZE 012T 1000 1200 1300 1700 AZE 012T 1200 1450 1600 2030 AZE 015T 1500 1800 1950 2540 AZE 020T 2400 2900 3200 4050 AZE 030T 3000 3600 3900 5080 AZE 040T 3500 4200 4650 5900 AZE 050T AZE 012T model 11

NETWORK PROTECTION MEDIUM VOLTAGE 10 ka AZE---T SERIES ARRESTER 10 ka 40 GENERAL CHARACTERISTICS AZE---T NETWORK PROTECTION MEDIUM VOLTAGE 39

NETWORK PROTECTION MEDIUM VOLTAGE 10 ka CLASS 2 AZE--- T GENERAL CHARACTERISTICS ACCORDING TO IEC 60099-4. Zinc oxide varistors. Silicone rubber housing. Outdoor and indoor use. High resistance to vibrations. High resistance to vandalism. Can be connected to line with aluminium or copper cables from 25 to 148 mm 2 (with or without terminal). Single-arrester packed in a cardboard box. Ordering example: 1 AZE 040T PHYSICAL CHARACTERISTICS Insulation of housing Leakage Height Unit weight Arrester type H 1 2 (kg) Lightning impulse 50 Hz 1.2/50 µs (kvc) wet (kvrms) Mounting clearances AZE 010T 400 174 1,2 29 160 160 AZE 012T 400 174 1,2 29 160 160 AZE 015T 400 174 1,3 38 180 160 AZE 020T 400 174 1,4 38 180 160 AZE 030T 400 176 1,4 38 190 160 AZE 040T 400 176 1,4 43 210 160 AZE 050T 400 176 1,5 46 230 160 A min A H 40 120

10 ka CLASS 2 NETWORK PROTECTION MEDIUM VOLTAGE ELECTRICAL AND MECHANICAL CHARACTERISTICS Nominal discharge current 10 ka 8/20 µs impulse Line discharge class 2 High current 2 x 100 ka 4/10 µs impulses Long duration current 20 x 600 A 2000 µs impulses Energy absorption capacity 5.5 kjoule/kv of Uc for one 2000 µs impulse Service temperature - 40 C to + 50 C (+60 C short duration) Permanent cantilever strength 100 N.m Max cantilever strength for one minute 250 N.m Max torsion strength 30 N.m Pollution area IEC 60815 3 Short circuit rating after over failure 20000 A for 0.2 s / 600 A for 1 s according to IEC 60099-4 Partial discharge level at 1.05 Uc < 3pc CAPABILITY TEMPORARY OVERVOLTAGE AZE---T line arresters do not have spark gaps in series. The zinc oxide ceramics are designed to the continuous phase to ground of the network. They are capable of bearing increased operational s for a limited period. The temporary over characteristics give the duration T and corresponding TOV with respect to continuous Uc. The curve E = 0 is valid for arresters without any energy preloading. The other curve is valid for arresters that have already absorbed impulses corresponding to their maximum energy absorption capacity. K = TOV / Uc Energy absorbed = 0 Energy absorbed = max. capacity T(s) TOV duration PROTECTIVE CHARACTERISTICS Arrester type Nominal Voltage (V) Highest Continuous Voltage Umax1(V) Highest over of duration 300s Umax2 (V) Highest over of duration 20 ms Umax3 (V) 2,5 ka 8/20µs Max. Residual (kvc) LIGHTNING IMPULSE 5 ka 8/20µs 5 6 10 ka 8/20µs Max. Residual (kvc) at 10 ka 1/20µs STEEP CURRENT IMPULSE Max. Residual (kvc) SWITCH IMPULSE 250 A 500 A AZE 010T 750 900 1000 1270 2,4 2,5 2,7 3,0 3,3 2,9 2,0 2,1 2,2 AZE 012T 1000 1200 1300 1700 3,0 3,2 3,4 3,7 4,2 3,7 2,5 2,6 2,7 AZE 015T 1200 1450 1600 2030 5,3 5,7 6,1 6,7 7,5 6,7 4,5 4,7 4,9 AZE 020T 1500 1800 1950 2540 5,9 6,3 6,8 7,5 8,3 7,5 5,0 5,2 5,4 AZE 030T 2400 2900 3200 4050 8,4 9,0 9,7 10,6 11,8 10,6 7,1 7,4 7,7 AZE 040T 3000 3600 3900 5080 8,9 9,5 10,2 11,2 12,5 11,2 7,5 7,9 8,1 AZE 050T 3500 4200 4650 5900 11,9 12,6 13,6 15,0 16,7 15,0 10,0 10,5 10,8 20 ka 8/20µs 40 ka 8/20µs 125 A 1 2 5 6 See page 14 41

ACCESSORIES 43 ARRESTER MOUNTING BRACKETS 43 STANDARD. 43 TYPE DIN. 44 NEMA. 44 INSULATING. 45 ARRESTER LINE CONNECTIONS 46 AUTOMATIC DISCONNECTION DEVICE 46 SURGE COUNTER WITH LEAKAGE CURRENT METER 42 ACCESSOIRES 46 47 48 BIRD PROTECTIVE INSULATING CAP FAULT INDICATOR 47 MODELS TO MOUNT ON ARRESTER. 47 MODELS TO MOUNT ON THE GROUND CABLE OF ARRESTERS. ARCING HORNS 48 FOR LINE POST INSULATORS. 48 FOR SUSPENSION AND TENSION INSULATORS.

ACCESSORIES ARRESTER MOUNTING BRACKETS STANDARD Ø 12,5 Ø 13 Ø 14 60 L Strip L 50 EZX 1 100 EZX 2 150 EZX 3 210 EZX AZ 200 152 203 50 Ø 13 50 200 AZPTR AZ 50-50 TYPE DIN Ø 13 Ø 13 25,4 60 Ø 13 152 197 197 Ø 13 14,5 25,4 60 152 AZX 1 AZX 2 43

ACCESSORIES NEMA 100 80 min. AZNEMA INSULATING 197 150 197 150 24,5 24,5 114-140 Ø 10 Ø 12 Ø 14 Ø 14 SUP M10 SUP M12 44

ACCESSORIES ARRESTER LINE CONNECTIONS 30 30 M 12 50 +3 0 30 min. 30 min. M 10 M 12 M 12 A M 12 38 +3 0 50 +3 0 M 12 B M 16 33 57,5 M 12 C M 12 D 45

ACCESSORIES AUTOMATIC DISCONNECTION DEVICE DEC M10 Device for disconnecting an arrester in the event of arrester failure to prevent a permanent fault and provides a visible signal of the faulty arrester. The operator can energize the line again and re-establish the service. However, the over protection is removed. Periodic maintenance inspections must be scheduled to replace disconnected arresters. The device must be connected to ground by a flexible cable to enable an effective operation and provide a visual indication of the disconnection. Disconnector on a normally operating arrester To order this accessory, use the references with the figure 2: Examples : EZBD 122 - AZBD 122 - AZC 122 - AZE 0122 T. Faulty arrester. The disconnector has fallen SURGE COUNTER WITH LEAKAGE CURRENT METER ZC B1-M The ZC B1-M surge counter is supplied for monitoring arresters with the purpose of preventive maintenance. It is used to measure the leakage current circulating in the arresters and record the number of discharges that it absorbs. The counter must be connected between the arrester and the ground, ideally by an insulated cable of the shortest possible length. The arrester will be replaced when the leakage current will exceed three times the initial value when arrester was installed. The current must be read under normal, dry atmospheric conditions. Indeed, wet or rainy conditions can increase the value of the current due to additive surface currents circulating on the arrester housing. Insulator support Earth ground BIRD PROTECTIVE INSULATING CAP CAP M10 The Dervasil insulating cap (Polyamid moulded) is specially designed for fitting on the arrester top. 46

ACCESSORIES FAULT INDICATORS Designed to indicate the failure of an arrester without disconnecting the arrester from the network. The line can be energised again after replacing the failed arrester. The fault indicator enables the maintenance staff to quickly locate the damaged arrester and replace it to re-establish the service. Three indicator types are available. MODELS TO MOUNT ON THE ARRESTER MX 481 Device operating from 15 A for compensated or high impedance grounded neutral networks. To order this accessory, use the references with the letter P: Examples : EZP 12 - AZP 12 - AZCP 12 - AZE P 012 T. Visual indication Indicator in normal condition Indicator after arrester failure INDIC 150 A Device operating from 150 A for low impedance or solidly grounded neutral networks. To order this accessory, use the references with the figure 1: Examples : EZBD 121 - AZBD 121 - AZC 121 - AZE 0121 T. Indicator in normal condition Faulty arrester. The indicator has fallen MODEL TO MOUNT ON THE GROUND CABLE OF ARRESTER MX 480 Ground cable Normal condition RESET After removal of faulty arrester, reset with the device MX-480/test Metal strip Fault condition TEST Before installation, test with the device MX-480/test Mounting on the ground connection cable 47

ACCESSORIES ARCING HORNS For isolated cable overhead lines, large installation of over protection is absolutely necessary. We provide an economical solution by combining arcing horns with the arrester. This device is installed in parallel to line post, suspension or tension insulators. FOR LINE POST INSULATORS Ø12 20 13 R12 25 97 119 R20 R20 Ø20 70 45 L R20 90 M10 Ø 24 90 160 R20 30 EPARAF EPHASE FOR SUSPENSION AND TENSION INSULATORS R12 maxi 60 28 R10 Ø11 4 22 50 + - 1 Ø12 50 80 10 R20 Ø12 45 30 CORNE 1 CORNE 2 48

INSULATORS FOR RAILS NETWORKS RC 60-3A1 TENSION INSULATOR 3 kv CC INFRABEL (BELGIUM) COMPLIANT WITH IEC 61952 STANDARD AND INFRABEL SPECIFICATION I405 460003 Insulator Reference RC 60-3 Type A1 Typical line CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) 3 60 374 164 3/2 100/64 1,2 Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative 75 38 95 95 RC 60-3B2 TENSION INSULATOR 3 kv CC INFRABEL (BELGIQUE) COMPLIANT WITH IEC 61952 STANDARD AND INFRABEL SPECIFICATION I405 460003 Reference Insulator RC 60-3 Type B2 Nominal CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) 3 60 374 164 3/2 100/64 1,4 Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative 75 38 95 95 51

INSULATORS FOR RAILWAY NETWORKS RC 70-4 TENSION INSULATOR 3 kv CC RFI TYPE (ITALY) COMPLIANT WITH IEC 61109 STANDARD AND RFI SPECIFICATION TE 128 Reference Insulator Nominal (kvcc) CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative 3 70 330 216 2 80 1,6 RC 70-4 90 55 125 138 RC 9-4 SUSPENSION INSULATOR 3 kv CC COMPLIANT WITH IEC 61952 STANDARD AND RFI SPECIFICATION TE SP IFS 009 A Reference Insulator Nominal (kvcc) CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative RC 9-4 3 40 350 150 3 120 2,2 55 50 125 138 52

INSULATORS FOR RAILWAY NETWORKS RC 6-1 SUPPORT INSULATOR 3 kv CC COMPLIANT WITH IEC 61952 STANDARD AND INFRABEL SPECIFICATION I405-464.002 254 110 Reference Insulator Nominal (kvcc) CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative 3 25 385 165 5 110 3,2 RC 6-1 68 38 130 143 IC 50-3 SUPPORT INSULATOR 25 KV AC COMPLIANT WITH IEC 61952 STANDARD Reference Insulator Nominal CTS specified tensile load (kn) Leakage Arcing Number of sheds Shed diameter Weight (Kg) Dry power Wet power Lightning impulse 1.2/50 µs Positive Negative IC 50-3 25 50 860 310 7/6 120/80 2,2 125 100 200 255 53

This documentation is not contractual. The items featured are available while stocks last. DERVASIL reserves the right to interrupt manufacturing them or to modify their characteristics without prior notification. Non-contractual photos

MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS Distributed by: Dervasil / Route de Popenot 42800 Saint Joseph Tel : +33(0)4 77 83 22 81 Fax : +33 (0)4 77 83 22 80 Email : info@dervasil.com SICAME GROUP