High Temperature Marker Tag

Similar documents
B 344 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers.

BRADY SAS Parc Eurocit- Bat 12 45, Ave de l Europe RONCQ Cx Tel : Fax :

RPL "Raised Panel Label"

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product

Halogen Free, Flame-retardant Polyether based TPU

Safety Mat System Installation Instructions

SilFORT* SHP401. Technical Data Sheet. SilFORT* SHP401. Description SilFORT AS4000 Hard Coat

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF

VentureClad Insulation Jacketing Tapes 1577 Series

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

3 Automotive Structural Adhesives

Metallic Systems TYPE SPTC

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer

TAIYO S-200W LP WHITE THERMAL CURE LEGEND INK

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

SIGMACOVER 805. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

3M TM Dyneon TM Fluoroplastics. Product Comparison Guide.

SIGMAZINC 105. PRODUCT DATA SHEET December 15, 2014 (Revision of July 1, 2013) DESCRIPTION. Two-component, zinc epoxy primer PRINCIPAL CHARACTERISTICS

SIGMAZINC 102 HS. PRODUCT DATA SHEET December 15, 2014 (Revision of December 1, 2012) DESCRIPTION

Installation, Operation & Maintenance. Model 7678 End of Line Deflagration Flame Arrester ATEX Certified

SIGMAZINC 68 SP / AMERCOAT 68 SP

Directive 1999/13/EC, SED: max g/kg max g/l (approx. 2.6 lb/us gal) 6.6 m²/l for 100 µm (265 ft²/us gal for 4.

NOVAGUARD 890. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Paraplex Resins for Industrial Coatings

Chenguang Fluoroelastomer

MACP TB. 23 db Coupler MHz Rev. V1. Features. Functional Schematic. Description. Pin Configuration 4. Ordering Information 1,2

SIGMADUR PRODUCT DATA SHEET December 12, 2014 (Revision of January 1, 2013) DESCRIPTION. Two-component, high solids polymeric urethane

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Electrostatic Fieldmeter

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

SIGMADUR 520. PRODUCT DATA SHEET December 12, 2014 (Revision of May 01, 2013) DESCRIPTION

ALPHA OM-5002 HIGH SPEED, PIN TESTABLE SOLDER PASTE

Neopolen. Contents. 1. Product 1.1 Description 1.2 Forms supplied 1.3 Delivery, Conveying, Storage

Installation Guide. Marking and Inspection Gauge. Marking Gauge. Inspection Gauge E 1. Marking and inspection gauges are combined into one gauge.

3 TM Cold Applied Barrier Boot System

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

PTC Thermistor for Automotive:TPM-C Series

Instruction Manual Part No

SIGMATHERM 230 / PPG HI-TEMP 230

NOVAGUARD 840. PRODUCT DATA SHEET January 21, 2015 (Revision of December 12, 2014) DESCRIPTION

KleerBanD. flange protectors & RADOLID PROTECTION CAPS ADVANCE PRODUCTS & SYSTEMS. I S O C e r t I f I e d C O m pa ny - fm

ATN3580 Series: Fixed Attenuator Pads

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

SIGMACOVER 350. PRODUCT DATA SHEET December 12, 2014 (Revision of June 1, 2014) DESCRIPTION

Terms and Conditions

Utility Controller Hand Air Operated

SIGMAGUARD 730. PRODUCT DATA SHEET December 15, 2014 (Revision of December 1, 2012) DESCRIPTION

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

UK PG 6/23(92) Appendix 3: max g/l (approx. 1.7 lb/us gal) 7.2 m²/l for 125 µm (289 ft²/us gal for 5.0 mils)

UK PG 6/23(92) Appendix 3: max g/l (approx. 3.6 lb/us gal) 5.7 m²/l for 100 µm (229 ft²/us gal for 4.0 mils)

PTC Thermistor for Automotive:TPM-C Series

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Polyline Polycarbonate Enclosures

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

Submersible Pond Pump with UV 800 Gallons Per Hour

NOVAGUARD 810. PRODUCT DATA SHEET December 11, 2014 (Revision of April 1, 2014) DESCRIPTION

POLYCAST CELL CAST ACRYLIC Solutions for Aerospace

Ducting & Ventilation Components

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

DRAIN WATER TEMPERING KIT

QCB Thermoplastic Bearing Units

SHINKONG SHINITE PBT. For Loose Tube

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Installation, Operation & Maintenance. Model 7688 In Line Deflagration Flame Arrester. ATEX Certified

LLumar Self-Healing Platinum Paint Protection Film

EMISSION CONTROL WARRANTY STATEMENT

Submersible Waterfall Pump 1200 Gallons Per Hour

Installation Instructions / Warranty

Electronic Materials Brochure

INSTALLATION INSTRUCTIONS. Feel free to contact us at with any questions you may have regarding your Lasergrips.

Penguin Gentoo 600B Cordless Sprayer User s Manual

Submittal Data. Fiberglass Bondstrand 3000A Pipe

Effects of wet lubrication on Bal Seal spring-energized seal performance

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

3M Three-Wall and Four-Wall Headers. Series 3XXX

MAINTENANCE NOTE: ANY LEAK FROM THE MAIN BODY OF THE LOAD IS AN INDICATION THAT THE UNIT SHOULD BE RETURNED TO THE FACTORY FOR REPAIRS.

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, CROSSLINKED CHLORINATED POLYOLEFIN, FLEXIBLE

ESE Series Cast Iron Sewage Pumps

User s Manual TX MHz Powercaster TM Transmitter

OPERATOR S MANUAL. MODEL ORDER # MODEL HD 2.0/10 Ed HE D HD 1.8/14 Ed HE D

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Installation Power Management Unit Battery Cables and Battery Harness

MODEL VG08001 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

INSTALLATION INSTRUCTIONS

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

OPERATOR S MANUAL HD 2.3/24 P CD HD 2.3/23 P CD

SIGMASHIELD PRODUCT DATA SHEET August 22, 2018 (Revision of April 18, 2018) DESCRIPTION

KLEERBAND FLANGE PROTECTORS & RADOLID PROTECTION CAPS ADVANCE PRODUCTS & SYSTEMS. ISO-9001 Ce r t i f i e d Co m p a n y - FM537405

Technical Data 3M Petroleum Sorbents

Thermaltake Warranty / Support Information

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

Transcription:

Tinley Park, IL 0487 High Temperature Marker Tag This specification is intended to outline the physical and chemical properties of PANDUIT s material for identification purposes. Printable Material Suffixes FPT FQT FQT-B PRODUCT SPECIFICATIONS: Description: Recommended Ribbons: Standard Colors: Thickness: Material is RoHS compliant (European Union directive 2002/95/EC). is a crosslinked, thermal transfer printable polyolefin. When printed using RMR*BL, RMER4BL-A, and RMH*BL thermal transfer ribbons it will also meet MIL-M- 81531. This product has been tested for use as an identification marker for use in (Class 1E) harsh environments in various high temperature power plants. RMR*BL, RMER4BL-A, RMH*BL (recommended for best print quality) White 24 +/- 2 mils Service Temperature Range: Minus 7F to 275F (Minus 55C to 135C) Storage Conditions: Store at 70 F(21 C) and 50% Relative Humidity PROPERTIES: PERFORMANCE: Tensile Strength: 1500 psi minimum (ASTM D38) Elongation Ultimate: 200% minimum (ASTM D 38) Dielectric Strength: 500 volts/mil minimum (ASTM D87) Water Absorption: 0.5% maximum (ASTM D570) Printability: Product meets print performance as per MIL-M-81531 Flammability: Product complies with the UL94-V2 flammability test Specific Gravity: 1.35 max (ASTM 792) QUV Outdoor Durability: The samples were tested in a QUV weather tester as per test procedure ASTM G-154. Observations made at *3000 hours exposure showed no loss in legend or change in material. Page 1 of 5

Tinley Park, IL 0487 *3000 hours equates to 5 years of assimilated outdoor UV exposure. CHEMICAL/SOLVENT RESISTANCE: The testing was conducted at room temperature. Samples were thermal transfer printed with Panduit Resin ribbon on Panduit printer. Chemical/Solvent 7 DAY IMMERSION DIP TEST RUB TEST 30% Sulfuric 10% Sulfuric 30% Hydrochloric 10% Hydrochloric 50% Sodium 2 1 1 3 1 1 Methyl Ethyl Ketone 3 3 3 Acetone 3 3 3 1:1:1 Trichloroethane 2 1 3 Isopropyl Alcohol 3 1 1 ASTM#3 Oil SAE 30 Oil Alconox Toluene 2 1 3 Mineral Spirits Glacial Acetic Acid 3 3 3 Diesel Fuel Chloride Water Gasoline 1 = No change 2 = Slight failure in Legibility 3 = Failure in Legibility 7 Day Immersion Immersed in reagent for 7 days Dip Test - Five 10 minute dips in reagent followed by 30 minute recovery Rub Test - Rubbed sample for 1 minute with swab soaked in reagent Marking Performance: MIL-M-81531: Print still legible after 20 eraser rubs with hard hand pressure. Page 2 of 5

Tinley Park, IL 0487 CHEMICAL/SOLVENT RESISTANCE: The testing was conducted at room temperature. Samples were thermal transfer printed with Panduit Hybrid ribbon on Panduit printer. Chemical/Solvent 7 DAY IMMERSION DIP TEST RUB TEST 30% Sulfuric 10% Sulfuric 30% Hydrochloric 10% Hydrochloric 50% Sodium 2 1 1 Methyl Ethyl Ketone 3 3 3 Acetone 3 3 3 1:1:1 Trichloroethane 3 1 3 Isopropyl Alcohol 3 1 3 ASTM#3 Oil 2 1 1 SAE 30 Oil Alconox Toluene 2 1 3 Mineral Spirits 3 1 2 Glacial Acetic Acid 3 3 3 Diesel Fuel 3 1 2 Chloride Water Gasoline 3 1 2 1 = No change 2 = Slight failure in Legibility 3 = Failure in Legibility 7 Day Immersion Immersed in reagent for 7 days Dip Test - Five 10 minute dips in reagent followed by 30 minute recovery Rub Test - Rubbed sample for 1 minute with swab soaked in reagent Marking Performance: MIL-M-81531: Print still legible after 20 eraser rubs with hard hand pressure. Page 3 of 5

Tinley Park, IL 0487 High Temperature Plant (Class 1E) Harsh Environment Test Result Summary marker tag has been tested for use as an identification marker for use in harsh environments in various high temperature power plants. Printed markers were subjected to radiation exposure, thermal aging and LOCA/MSLB environmental testing as shown in the three tables below. Test margins related to IEEE 323-2003 were used. General Environmental Test Result Summary Table Item Normal Accident Service Life: 40 years 1 year Temperature 140F (0C) 30F (182.2C) (peak) Pressure Atmospheric 57 psig (peak) Relative Humidity 90% 100% (max) Radiation 2.0E7 rads 2.0E8 rads (TID) *Halogen Content Marker with (Print) Print Permanence Fluorine < 1.0 ppm Bromine < 1.0 ppm Chlorine < 7.0 ppm Iodine < 1.0 ppm Print remained legible with Not Applicable Thermal Print -No significant change no change in print density Physical Integrity No significant change Some warping and splitting but remained attached on wire Containment Spray Test Information Table Item Short Term (Injection Phase) Long Term (Recirculation Phase) Duration 4 hours 30 days Temperature 0-30F (1-182C) 0-30F (1-182C) Spray Density (gpm/ft^2.) >0.2 (25.3 L/min/m 2 ) >0.2 (25.3 L/min/m 2 ) Chemical Composition Hydrazine (N 2 H 4) Boric Acid (H 3 BO 3 ) ph 0-50 ppm 4,400 ppm 4.0-10.0 0-50 ppm 4,400 ppm 7.0-8.5 LOCA /MSLB Combined Temperature/Pressure Test Information Table TIME Seconds Temperature Deg F ( Deg C) Pressure PSIG (kpa) 0 120 (49) 0 (0) 10 300 (149) 57 (393) 50 30 (182) 57 (393) 250 30 (182) 57 (393) 270 275.3 (135.2) 57 (393) 1 X 10 3 275.3 (135.2) 57 (393) 1 X 10 4 230 (110) 4 (317) 1 X 10 5 190 (88) 20 (138) 1 X 10 150 () 10 (9) 2.592 X 10 (30 days) 150 () 10 (9) 1.572 X 10 7 (182 days) 142 (1) 10 (9) 3.15 X 10 7 (35 days) 142 (1) 10 (9) *The chemical analysis method SM4110B (De-ionized Water Soluble Method) was performed to identify concentration of halogen ions in this material that could potentially leach onto materials such as stainless steel and promote corrosion, This chemical analysis does not identify the concentration of toxic gaseous effluents released by burning this material. Page 4 of 5

Tinley Park, IL 0487 LIMITED WARRANTY All PANDUIT Identification Solution Products (except for Software programs) are warranted to be free from defects in material and workmanship at the time of sale but our obligation under this warranty is limited to replacement of the product proved to be defective within months from the date of sale, or in the case of printers, within 90 days from the date of sale. This warranty is void if the products or printers are modified, altered or misused in any way. Use of PANDUIT printers with any product other than the specified PANDUIT products for which the printer was designed constitutes misuse. Before using, the user shall determine the suitability of the product for its intended use and user assumes all risk and liability whatsoever in connection therewith. The foregoing may not be altered except by an agreement signed by officers or seller and manufacturer. NEITHER PANDUIT OR SELLER SHALL BE LIABLE FOR ANY OTHER INJURY, LOSS OR DAMAGE, WHETHER DIRECT OR CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR THE INABILITY TO USE THE PRODUCT OR THE PRINTER. THIS WARRANTY IS MADE IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF PARTICULAR USE ARE SPECIFICALLY EXCLUDED. The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a guide or use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. This publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc. Page 5 of 5