BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

Similar documents
Bullet Valve (BV) Series

Bullet Valve (BV) Series

82 Series MAConnect with Sub-D

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

92 Series MAConnect with Sub D

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

B SERIES. Bulletin B-2017

Technical Bulletin. MAC Valves, Inc., is pleased to announce. Introduction - Plunger up / Plunger Cooling / Counterblow Solutions

Section 2 Proportional Quick Exhaust

Direct solenoid and solenoid pilot operated valves

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Introduction Section 1 Section 2 Section 3

42 Series MAConnect TM. 42 Series Plug-In Manifold

MAC VALVES EUROPE, INC.

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Bulletin H-Tech 03 High Pressure Valves Series H

Combined pump and gripper Medium

ELITE 2-BURNER PROPANE BARBECUE Assembly Manual

Limit Switches and Safety

Easytork Solenoid Valve IOM

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

Vacuum Automation 2.1. The future depends on good product choices

Miniature Valves MH1. Extremely small, fast and versatile. Info 206

SITRANS P measuring instruments for pressure

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

MAC Pulse Valve PV03 Series

HERION. MINI ISO VALVES Size 18 mm, V40 / V41 SERIES Size 26 mm, V44 / V45 SERIES. Flexible subbase system with a wide range of accessories

VAL /4" to 2" Solenoid Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves. Solenoid pilot operated spring return inline valves with nonlocking

Specifications 54 Series Valve

Flow Control Valve Instruction Manual

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Product Information. 16 Series ROSS CONTROLS

Miniature Multimedia Valves

Product Information ROSS CONTROLS

Gauge Adapter Instruction Manual

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Turn-Dex (CD) 1-1/4 Series

C Linear Positioner (Small)

MAC Pulse Valve PV06 Series

2012 Series Solenoid Pilot Actuated Valves

Manifold w/ Needle Valve Instruction Manual

KRONES DIRECT REPLACEMENTS

CONTROLS VALVES FOR AIR FLOW CONTROL

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Contact Air Incorporated for further assistance. Ph:

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Valves, Fittings, and Manifolds Catalog. We make things MOVE

LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

TYPE S RELAY VALVE (Volume booster) Service Manual

TPCA Power Clamps Catalog

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Solenoid pilot operated spring return inline valves with nonlocking overrides, 120V, 60 Hz, and cablegrip connector

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Service and Parts Manual. Minimum Filtration Required:

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

Proportional Valves. Proportional solenoid valves for pressure and flow control

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

J1 Plug Pin Identification

PROCESS & AUTOMATED VALVES

ROSS CONTROLS. Compact Valves 16 Series.

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Product Information. 36 & RM Series ROSS CONTROLS

NEW! MAXIMATIC SOLENOID VALVES

ES, ESO SERIES VALVES ES, ESO SERIES COMPACT VALVES. 210 Clippard Instrument Laboratory, Inc

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

ValVes for air flow Control

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

SUPERSPOOL II VALVE PNEUMATIC DIRECTIONAL CONTROL VALVE SERVICE INFORMATION

Pneumatic. PVD Everdure Ceramic Valves

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Tie rods cylinders to ISO standard

REV: 000. Super Seca Flash Cure Units

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

Val-U-Act Ball Valve Operators. Air-Oil Systems, Inc.

Pneumatic. PVD Ceramic Valves

Transcription:

THINK GLOBAL ACT LOCAL P A T E N T T E C H N O L O G Y TEL: 1-800-MAC VLVS TEL: 1 (48) 64-7700 FAX: 1 (48) 64-0549 www.macvalves.com mac@macvalves.com MAC VALVES, INC. 5555 ANN ABO OAD DUNDEE, MI 48131 TEL: 1 (734) 59-5099 FAX: 1 (48) 863-959 MAC VALVES EUOPE, INC. UE MAIE CUIE, 1 B- 4431 ANS (LIEGE) BELGIUM TEL: 3 (4) 39 68 68 FAX: 3 (4) 63 19 4 info@macvalves.be MAC VALVES ASIA, INC. NO. 45, DONGYUAN OAD JHONGLI CITY, TAOYUAN COUNTY TAIWAN TEL: 886 (3) 463-6868 FAX: 886 (3) 463-4576 mva@macasia.com.tw MAC VALVES PACIFIC, INC. P.O. BOX 11 PENOSE, AUCKLAND NEW ZEALAND TEL: 64 (9) 634-9400 FAX: 64 (9) 634-9401 www.macvalves.co.nz sales@macvalves.co.nz D BULLET VALVE Our global distribution network is keeping your machines running around the clock around the world MAC VALVES, INC. P.O. BOX 111 30569 BECK OAD WIXOM, MI 48393-7011 E 999BVBA

Bullet (BV) Series The patented Bullet represents yet another evolution in air valve technology from MAC. VEY FEW PATS LONG LIFE LIFTING SOLENOID ONE PIECE POPPET / AMATUE BALANCED DESIGN SOLENOID ISOLATED FOM CONTAMINATED AI UNIQUE MOUNTING The threaded cartridge configuration allows for a variety of mounting possibilities, such as direct integration into pneumatic actuators or vacuum generators without the need of external tubing or fasteners. -way & 3-way models of the BV cartridge are available. A surface manifold mount configuration is also offered. D-SEAL TECHNOLOGY Minimum Friction Wiping Action Isolates Solenoid From Contaminated Air LONG LIFE LIFTING SOLENOID SHOT STOKE - High Shifting Forces (Energized) OVESTOKE - Built In Wear Compensation ONE PIECE POPPET/AMATUE Balanced & epeatable Cushioning - educes Solenoid Wear STONG ETUN SPING High Shifting Forces (De-energized) s That Don t Stick SM

Function Flow [max] Manifold mounting Series / Up to 0.08 Cv Cartridge BV10A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type Cartridge (Standard) Cartridge (Axial Flow) Way BV10A-CA1-00-xxxx-xxx BV10A-CB0-00-xxxx-xxx 1 SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound EH 4VDC (.5W) EG 4VDC (4.0W) EK 1VDC (.5W) EJ 1VDC (4.0W) 0 No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads * High wattage - high speed options - consult factory High wattage configurations require intermittent duty cycles. ** EC - Energy eduction Circuitry - educes the effective wattage at continuous duty EC wattage reduction options - consult factory CICUIT BA xx = Number of stations Not available for flying leads cover Only option for Pico cover 5 Solenoid cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode b & LED (no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board Bullet valve type Cyl. port size Spacing (mm) Side cylinder port Bottom cylinder port Standard Axial flow Note: Pico covers PC-PL have a 3rd Pin which is a location pin #10-3 UNF 1 CCMV10A-00AAA-xx CCMV10A-00BAA-xx M5 1 CCMV10A-00AAB-xx CCMV10A-00BAB-xx M7 1 CCMV10A-00AAC-xx CCMV10A-00BAC-xx #10-3 UNF 1 - CCMV10A-00BDA-xx M5 1 - CCMV10A-00BDB-xx M7 1 - CCMV10A-00BDC-xx Note: for valves mounted to bar at factory, add -9 to model numbers.

Technical Data Fluid: Pressure range: Lubrication: Filtration: Temperature range: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to +50 C) Up to 0.08 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6960 Insertion/removal socket: AT-1181 (Bit) AT-1185 (Bit Holder) AT-1184 (Handle) Dimensions 55.95 Bullet with JST Cover and Circuit Board for LED., MOV., & Diode Options BV10A (-way) - Standard Watt 11.70 14.00 CCMV10A - SIDE POTS 1.00 STATION SPACING CYL. TYP. 8.00 18.90 63.55 4.5 76.00 67.50 "P" INDICATES B.S.P.PL. "T" INDICATES B.S.P.T. 1/8"-7 N.P.T.F. O 1/8"-8 B.S.P.PL O 1/8"-8 B.S.P.T 0.00 10.50 7.90 36.00 8.10 4.5 TYP. () STATION # 1 6 8.33 DIA. DILL - 10.0 DEEP 10º C'SINK TO 10.5 DIA. 1/8"-7 N.P.T.F. TAP TO GAGE TYP. () (1) EACH END

Function Flow [max] Manifold mounting Series 3/ NC, Universal Up to 0.09 Cv Cartridge BV310A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type 3 Way N.C. 3 Way Universal Cartridge (Standard) 3 1 BV310A-CC1-00-xxxx-xxx 3 1 BV310A-CD1-00-xxxx-xxx SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound HA 4VDC (1.0W) HF 1VDC (1.0W) HB 4VDC (1.8W) HG 1VDC (1.8W) HC 4VDC (.5W) HH 1VDC (.5W) HD 4VDC (3.0W) HJ 1VDC (3.0W) HE 4VDC (4.0W) HK 1VDC (4.0W) * High wattage - high speed options - consult factory ** EC wattage reduction options - consult factory CICUIT BA 0 No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads Not available for flying leads cover Only option for Pico cover Solenoid cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode & LED(no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board Note: Pico covers PC-PL have a 3rd Pin which is a location pin Port size Spacing (mm) Side cylinder port # 10-3 UNF M5 M7 1 1 1 CCMV10A-00ABA-xx CCMV10A-00ABB-xx CCMV10A-00ABC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model numbers. * High wattage configurations require intermittent duty cycles. ** EC - Energy eduction Circuitry - educes the effective wattage at continuous duty. 7

Technical Data Fluid: Pressure range: Lubrication: Filtration: Temperature range: Flow (at 6 bar ΔP=1bar): Voltage range: Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to +50 C) Up to 0.09 Cv -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-6963 Insertion/removal socket: AT-1181 (Bit) AT-1185 (Bit Holder) AT-1184 (Handle) Dimensions Bullet with JST Cover and Circuit Board for LED., MOV., & Diode Options BV310A (3-way) - Standard Watt 60.40 11.70 14.00 CCMV10A - SIDE POTS 1.00 STATION CYL. SPACING TYP. 8.00 13.10 63.55 "P" INDICATES B.S.P.PL. "T" INDICATES B.S.P.T. 0.00 76.00 4.5 67.50 1/8"-7 N.P.T.F. O 1/8"-8 B.S.P.PL O 1/8"-8 B.S.P.T 10.50 7.90 36.00 8.10 4.5 TYP. () STATION # 1 8 8.33 DIA. DILL - 10.0 DEEP 10º C'SINK TO 10.5 DIA. 1/8"-7 N.P.T.F. TAP TO GAGE TYP. (4) () EACH END

Function Flow [max] Manifold mounting Series 3/ NC, Universal Up to 0.08 Cv Manifold mount - Non plug-in BV310A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life How To Order VALVE Type 3 Way N.C. 3 Way Universal Manifold Mount - Non plug-in SOLENOID OPEATO 3 1 BV310A-LC1-00-xxxx-xxx X XX X - X XX 3 1 BV310A-LD1-00-xxxx-xxx Solenoid Voltage Lead wire length B ound HA 4VDC (1.0W) HB 4VDC (1.8W) HC 4VDC (.5W) HD 4VDC (3.0W) HE 4VDC (4.0W) HF 1VDC (1.0W) HG 1VDC (1.8W) HH 1VDC (.5W) HJ 1VDC (3.0W) HK 1VDC (4.0W) * High wattage - high speed options - consult factory ** EC wattage reduction options - consult factory 0 No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) B Cover For Manifold Body Not available for flying leads cover Only option for Pico cover Solenoid cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode & LED(no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board Note: Pico covers PC-PL have a 3rd Pin which is a location pin NON PLUG-IN CICUIT BA Port size Spacing (mm) Side cylinder port Bottom cylinder port # 10-3 UNF 1 CBMV10A-00ABA-xx CBMV10A-00BBA-xx M5 1 CBMV10A-00ABB-xx CBMV10A-00BBB-xx M7 1 CBMV10A-00ABC-xx CBMV10A-00BBC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model numbers. Options How to order bar configured for regulator BV310A- LC 1-00-xxxx-xxx CBMV10A-00 A BB- xx eplace with D for regulator - Side ports eplace with 0 for no manual operator eplace with E for regulator - Bottom ports * High wattage configurations require intermittent duty cycles Note: egulator must be ordered separately - see next page **EC - Energy eduction Circuitry - educes the effectiveness wattage at continuous duty 9

Technical Data Fluid: Pressure range: Lubrication: Filtration: Temperature range: Flow (at 6 bar ΔP=1bar): Voltage range: Spare parts: Dimensions Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to +50 C) Up to 0.08 Cv -15% to +10% of nominal voltage Pressure seal, body to base: 16985 Mounting screw, body to base: 35166 - pcs required egulator for bar: P44A-A0AX X = A 0 to 100 PSI Blank Station Cover Plate: N-BV008 B 0 to 60 PSI C 0 to 40 PSI D 0 to 15 PSI 61.4 BV310A Bar Manifold Assembly 1.0 Without regulator CBMV10A Circuit bar for BV310 11.5 With regulator 4.5 dia thru 71.4 80.0 10

Function Flow [max] Manifold mounting Series / Up to 0.4 Cv Cartridge BV14A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type -Way (standard) -Way (axial flow) 1 1 Cartridge BV14A-CA1-00-xxxx-xxx BV14A-CB0-00-xxxx-xxx SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound CA 4VDC (1.0W) CB 4VDC (1.8W) CC 4VDC (.5W) CD 4VDC (3.0W) CE 4VDC (4.0W) CF 1VDC (1.0W) CG 1VDC (1.8W) CH 1VDC (.5W) CJ 1VDC (3.0W) CK 1VDC (4.0W) CICUIT BA 0 * No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model numbers. 11 Solenoid cover Bullet valve type Cyl. port size Spacing (mm) Side cylinder port Bottom cylinder port Standard Axial flow *Not available for flying leads cover Only option for Pico cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode & LED (no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board GA MAC JAC Connector Note: Pico covers PC-PL have a 3rd Pin which is a location pin M7 17 CCMV14A-00AAA-xx CCMV14A-00BAA-xx 1/8 17 CCMV14A-00AAB-xx CCMV14A-00BAB-xx 5/3 tube recpt. 17 CCMV14A-00AAC-xx CCMV14A-00BAC-xx M7 17 - CCMV14A-00BDA-xx 1/8 17 - CCMV14A-00BDB-xx equires special spacing - - consult factory Note: Common inlet & exhaust are 1/4 NPTF For BSPPL or BSPT threads consult factory

Technical Data Fluid: Compressed air, vacuum, inert gases Pressure range: Vacuum to 10 PSI Lubrication: Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) Filtration: 40µ Temperature range: 0 F to 10 F (-18 C to +50 C) Flow (at 6 bar, P=1bar): Up to 0.4 Cv (4.0 W) Voltage range: -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-7331 Insertion/removal socket: AT-163 (Bit) AT-1185 (Bit Holder) AT-164 (Handle) Dimensions Flying leads JST Connector MAC Jac 69.4 ø 16.5 66.6 ø 16.5 69.7 ø 1.5 CCMV14A bar with BV14A valves 6.4 THU TYP. () 50.8 5.4 5.5 81.0 9.0 73.3 38.0 0.5 17.0 TYP. VALVE SPACING 1 1/4 NPTF TYP () (1) Each side

Function Flow [max] Manifold mounting Series 3/ Up to 0.4 Cv Cartridge BV314A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type 3-Way N.C. 3-Way universal valve 3 1 3 1 Cartridge BV314A-CC1-00-xxxx-xxx BV314A-CD1-00-xxxx-xxx SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound CA 4VDC (1.0W) CB 4VDC (1.8W) CC 4VDC (.5W) CD 4VDC (3.0W) CE 4VDC (4.0W) CF 1VDC (1.0W) CG 1VDC (1.8W) CH 1VDC (.5W) CJ 1VDC (3.0W) CK 1VDC (4.0W) CICUIT BA 0* No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads *Not available for flying leads cover Only option for Pico cover Solenoid cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode & LED(no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board GA MAC JAC Connector Note: Pico covers PC-PL have a 3rd Pin which is a location pin Cyl. port size Spacing (mm) Side cylinder port Bottom cylinder port M7 17 CCMV14A-00ABA-xx CCMV14A-00BBA-xx 1/8 17 CCMV14A-00ABB-xx CCMV14A-00BBB-xx 5/3 tube receptacle 17 CCMV14A-00ABC-xx CCMV14A-00BBC-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model numbers. 13 equires special spacing - - consult factory Note: Common inlet & exhaust are 1/4 NPTF For BSPPL or BSPT threads consult factory

Technical Data Fluid: Compressed air, vacuum, inert gases Pressure range: Vacuum to 10 PSI Lubrication: Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) Filtration: 40µ Temperature range: 0 F to 10 F (-18 C to +50 C) Flow (at 6 bar, P=1bar): Up to 0.4 Cv (4.0 W) Voltage range: -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-731 Insertion/removal socket: AT-163 (Bit) AT-1185 (Bit Holder) AT-164 (Handle) Dimensions Flying leads JST Connector MAC Jac 76. 75.3 76.5 16.5 16.5 CCMV14A bar with BV314A valves 1.5 6.4 THU TYP. () 50.8 5.4 5.5 81.0 9.0 79.3 44.0 1/4 NPTF TYP (4) () Each side 0.5 17.0 TYP. VALVE SPACING 14

Function Flow [max] Manifold mounting Series / Up to 0.6 Cv Cartridge BV1A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type -Way (standard) -Way (axial flow) 1 1 Cartridge BV1A-CA1-00-xxxx-xxx BV1A-CB0-00-xxxx-xxx SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound CA 4VDC (1.0W) CB 4VDC (1.8W) CC 4VDC (.5W) CD 4VDC (3.0W) CE 4VDC (4.0W) CF 1VDC (1.0W) CG 1VDC (1.8W) CH 1VDC (.5W) CJ 1VDC (3.0W) CK 1VDC (4.0W) Note: For CICUIT BA ordering information please consult factory Solenoid can (round) Solenoid cover 0 * No lead wire C For Top Cover M1 JST Pico Flying Leads A 18 Option and Can w/ B 4 Outer Threads C 36 C D 48 E E 7 F 96 G H 144 J L *Not available for flying leads cover Only option for Pico and M1 cover N TA BA No ground wire TC PC BC Blocking & suppr. diode & LED (no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board GA MAC JAC Connector Note: Pico covers PC-PL have a 3rd Pin which is a location pin 15

Technical Data Fluid: Compressed air, vacuum, inert gases Pressure range: Vacuum to 10 PSI Lubrication: Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) Filtration: 40µ Temperature range: 0 F to 10 F (-18 C to +50 C) Flow: Up to 0.60 Cv (4.0 W) Voltage range: -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-7571 Insertion/removal socket: AT-1365 (Bit) Dimensions Flying leads JST Connector M1 99.0 3.5 3.5 DIA. 99.7 3.5 DIA. 3.5 DIA. 107.7 3.5 3.5 DIA. DIA. BV1A valves 16 14

Function Flow [max] Manifold mounting Series 3/ Up to 0.6 Cv Cartridge BV31A OPEATIONAL BENEFITS 1. Short stroke with high shifting forces. Balanced poppet, immune to pressure fluctuations 3. Precise repeatability 4. Solenoid isolated from contaminated air 5. Very few parts 6. Extremely long life 7. Unique mounting - no fasteners or screws required How To Order VALVE Type 3-Way N.C. 3-Way universal valve 3 1 3 1 Cartridge BV31A-CC1-00-xxxx-xxx BV31A-CD1-00-xxxx-xxx SOLENOID OPEATO X XX X - X XX Solenoid Voltage Lead wire length B ound CA 4VDC (1.0W) CB 4VDC (1.8W) CC 4VDC (.5W) CD 4VDC (3.0W) CE 4VDC (4.0W) CF 1VDC (1.0W) CG 1VDC (1.8W) CH 1VDC (.5W) CJ 1VDC (3.0W) CK 1VDC (4.0W) CICUIT BA 0* No lead wire A 18 B 4 C 36 D 48 E 7 F 96 H 144 Solenoid can (round) C For Top Cover Option and Can w/ Outer Threads *Not available for flying leads cover Only option for Pico and M1 cover M1 C E G J L N Solenoid cover JST Pico Flying Leads TA BA No ground wire TC PC BC Blocking & suppr. diode & LED(no ground) TE PE BE Blocking & suppr. diode (no ground) TG PG BG LED (no ground) TJ PJ BJ MOV (no ground) TL PL BL LED & MOV (no ground) PN Transfer Board GA MAC JAC Connector Note: Pico covers PC-PL have a 3rd Pin which is a location pin Cyl. port size Spacing (mm) Side cylinder port Bottom cylinder port 1/8 5 CCMV1A-00ABA-xx CCMV1A-00BBA-xx 1/4 5 CCMV1A-00ABB-xx CCMV1A-00BBB-xx xx = Number of stations Note: for valves mounted to bar at factory, add -9 to model numbers. Note: Common inlet & exhaust are 3/8 NPTF For BSPPL or BSPT threads consult factory 17

Technical Data Fluid: Compressed air, vacuum, inert gases Pressure range: Vacuum to 10 PSI Lubrication: Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) Filtration: 40µ Temperature range: 0 F to 10 F (-18 C to +50 C) Flow: Up to 0.60 Cv (4.0 W) Voltage range: -15% to +10% of nominal voltage Tools: Manifold cavity step reamer: T-7573 Insertion/removal socket: AT-1365 (Bit) Dimensions Flying leads JST Connector M1 105.0 3.5 105.5 3.5 DIA. 105.0 3.5 DIA. 113.7 3.5 DIA. DIA. CCMV1A bar with BV31A valves 6.00 11.00 6.40 DIA.(M6 MTG. HOLE) TYP.() 7.00 7.00 TYP. BV31A VALVES MTG. HOLES TYP.() 4.50 5.00 TYP. SIDE POT 3/8" EXHAUST COMMON TYP. BOTH ENDS 1/8" SIDE CYLINDE POTS 113.1 APPOX. 18.50 4.50 58.50 58.50 EF. 30.35 TYP. CYLINDE POTS 44.00 TYP.() 3/8" INLET COMMON TYP. BOTH ENDS 4.50 5.00 TYP. SIDE POT 56.00 18 14 14.00

Connector Options BV10 Flying Leads (BA) 54.80 ØØ11.70 Flying Leads w/ LED (BC, BG, BL) 55.95 Ø11.50 11.70 JST Connector (TA) 43.60 ØØ11.70 JST Connector w/ LED (TG, TL) 56.15 ØØ11.70 Pin PICO (PN) 50.30 Ø 11.70 3 Pin PICO (PC, PE, PG, PJ, PL) 1 (POS) 4 (LOCATING PIN) 3 (NEG) 19 54.30 Ø 11.70

Connector Options BV310 Flying Leads (BA) 58.55 Ø11.70 Flying Leads w/ LED (BC, BG, BL) 60.40 ØØ11.70 JST Connector (TA) 58.06 ØØ11.70 JST Connector w/ LED (TG, TL) 60.60 Ø Ø11.70 Pin PICO (PN) 54.75 Ø 11.70 3 Pin PICO (PC, PE, PG, PJ, PL) 1 (POS) 4 (LOCATING PIN) 3 (NEG) 0 58.75 Ø 11.70

Connector Options BV14 Flying Leads (BA) Flying Leads w/ LED (BC, BG, BL) 69.4 Ø 16.5 JST Connector (TA) 7.1 Ø 16.5 JST Connector w/ LED (TC, TG, TL) 66.6 Ø 16.5 7.1 Ø 16.5 MAC Jac (GA) 69.7 Ø 1.5 Pin PICO (PN) 74.30 Ø 16.50 3 Pin PICO (PC, PE, PG, PJ, PL) 1 (POS) 4 (LOCATING PIN) 78.30 Ø 16.50 1 3 (NEG)

Connector Options BV314 Flying Leads (BA) Flying Leads w/ LED (BC, BG, BL) 76. Ø 16.5 79.0 Ø 16.5 JST Connector (TA) 75.3 Ø 16.5 JST Connector w/ LED (TC, TG, TL) 79.0 Ø 16.5 MAC Jac (GA) 76.5 Ø 1.5 Pin Pin PICO PICO(PN) 81.10 Ø 16.50 3 Pin 3 Pin PICO PICO(PC, PE, PG, PJ, PL) 1 (POS) 4 (LOCATING PIN) 85.10 Ø 16.50 3 (NEG)

Cartridge Modifications Our manufacturing process of the Bullet cartridge body enables flexibility with regards to offering potential modifications that meet your specific application needs. An example of such modifications is the axial flow cartridge body we are currently offering for the BV09, BV10 and BV14 series. The axial flow cartridge enables the valve to flow air between the bottom of the valve body and manifold it is housed in see figure below. This modification allows for a linear flow path out of the manifold producing measurably higher outlet pulse height (force) in blow off type of applications. We have currently used this modification for applications in the sorting industry with excellent results. If you have an application that would benefit from utilizing the axial flow cartridge option or wish to discuss other potential cartridge modifications, please consult your local MAC distributor (MDN Associate). By understanding your application and valve requirements we can optimize the valve settings accordingly. 3 15

N O T E S 4

PECAUTIONS AND WANINGS CONCENING THE APPLICATION, INSTALLATION AND SEVICE OF MAC VALVES AND OTHE MAC VALVES PODUCTS The warnings and precautions below are important to be read and understood before designing into a system any MAC s products, and before installing or servicing any MAC s product. Improper use, installation or servicing of any MAC s product in some systems could create a hazard to personnel or equipment. No distinction in importance should be made between the terms warnings and precautions. WANING :. Under no circumstances are MAC s products to be used in any application or in any manner where failure of the MAC s product to operate as intended could in any way jeopardize the safety of the operator or any other person or property. Do not operate outside of pressure range listed on a valve label or outside of the designated temperature range. Air supply must be clean and dry. Moisture or contamination can affect proper operation of the valve. Before attempting to repair, adjust or clean a MAC s product, consult catalog, parts & operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. If air line lubrication is used do not use any lubrication other than those recommended in the catalog, parts & operation sheet or by the factory. APPLICATION PECAUTIONS :. INDUSTIAL USE - MAC products are intended for general use in industrial pneumatic and/or vacuum systems. They are general purpose industrial products with literally thousands of different applications in industrial systems. These products are not inherently dangerous, but they are only a component of an overall system. The system in which they are used must provide adequate safeguards to prevent injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders, valves or any other component. POWE PESSES - MAC products are not designed nor intended to be used to operate and/or control the operation of clutch and/or brake systems on power presses. There are special products on the market for such use. -POSITION VALVES - Some MAC valves are -position, 4-way valves. When air is supplied to the inlet port(s) of these valves, there will always be a flow path from the inlet to one of the outlets regardless of which of the two positions the valve is situated. Therefore, if pressurized air retained in the system would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the trapped air. 3- POSITION VALVES- Some MAC valves are 3-position, 4-way valves. These valves are either double solenoid or double remote air operated. If either of the two operators is in control, air supplied to the inlet port(s) will pass through the valve to one of the outlets as on -position, 4-way valves. However, if neither operator is in control, the valve moves to a center position. Listed below are the various center position functions : A. CLOSED CENTE- With this type valve, when in the center position all ports are blocked (inlets and exhausts) meaning the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard in the application or servicing, a separate method in the system must be provided to remove the trapped air or this type valve should not be used. B. OPEN CENTE- With this type valve, when in the center position, the inlet port(s) is blocked and the two outlet ports are open to the exhaust port(s) of the valve. If having no air in either outlet port would present a hazard in the application or servicing, this type valve should not be used. C. PESSUE CENTE- With this type valve, when in the center position, the inlet port(s) is connected to both outlet ports of the valve. If having pressurized air to either or both outlet ports would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the retained air or this type valve should not be used. OPEATING SPECIFICATIONS - MAC s products are to be installed only on applications that meet all operating specifications described in the MAC catalog for the MAC s product. MANUAL OPEATOS- Most MAC valves can be ordered with manual operators. Manual operators when depressed, are designed to shift the valve to the same position as would the corresponding solenoid or remote air pilot operator if it were activated. Care must be taken to order a type, if any, that will be safe for the physical location of the manual operator in the system. If intentional or accidental operation of a valve by a manual operator could cause personal injury or property damage, a manual operator should not be used. EMOTE AI OPEATED VALVES Pilot valves supplying signal pressure to remote air operated valves should be 3-way valves with adequate supply and exhaust capacity to provide positive pressurizing and exhausting of the pilot supply line. Pilot lines should be open to exhaust when valves are deenergized. INSTALLATION PECAUTIONS :. A. Do not install any MAC s product without first turning off air (bleed system completely) and electricity to the machine. B. MAC s products should only be installed by qualified, knowledgeable personnel who understand how the specific valve is to be pneumatically piped and electrically connected (where applicable). Flow paths through the valve are shown in the catalog and on the valve by use of ANSI or ISO type standard graphic symbols. Do not install unless these symbols and the valve functions and operations are thoroughly understood. C. If air line lubrication is used do not use any lubrication other than those recommended in the catalog, parts & operation sheet or by the factory. SEVICE PECAUTIONS : A. Do not service or remove from service any MAC s product without first shutting off both the air and electricity to the valve and making certain no pressurized air which could present a hazard is retained in the system. B. MAC s products should only be serviced or removed from service by qualified, knowledgeable personnel who understand how the specific product is used and/or how the specific valve is piped and used and whether there is air retained in the connecting lines to the valve or electric power still connected to the valve. C. Before attempting to repair, adjust or clean a MAC s product, consult catalog, parts & operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. D. MAC s products are never to be stepped on while working on a machine. Damage to a MAC valve, or other product or lines to the product (either air or electrical lines) or accidental activation of a manual operator on the valve could result in personal injury or property damage. LIMITATION OF GUAANTEE. This Guarantee is limited to the replacement or rebuilding of any valve or other product which should fail to operate properly. s or other products, under the MAC Guarantee, must be returned (with or without bases) transportation prepaid and received at our factory within the Guarantee period. They will be returned to the customer at the expense of MAC s, Inc., and will carry the same guarantee as provided under the Flat ate ebuild Program. DISCLAIME OF GUAANTEE. No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not in the normal course of its use and maintenance during the warranty period. The guarantee does not apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes beyond the control of MAC s,inc. MAC s, Inc. shall in no event be liable for remote, special or consequential damages under the MAC Guarantee, nor under any implied warranties, including the implied warranty of merchantability. The above Guarantee is our manner of extending the engineering and service resources of the MAC s, Inc. organization to assure our customer long, and continued satisfaction. www.macvalves.com

THINK GLOBAL ACT LOCAL P A T E N T T E C H N O L O G Y TEL: 1-800-MAC VLVS TEL: 1 (48) 64-7700 FAX: 1 (48) 64-0549 www.macvalves.com mac@macvalves.com MAC VALVES, INC. 5555 ANN ABO OAD DUNDEE, MI 48131 TEL: 1 (734) 59-5099 FAX: 1 (48) 863-959 MAC VALVES EUOPE, INC. UE MAIE CUIE, 1 B- 4431 ANS (LIEGE) BELGIUM TEL: 3 (4) 39 68 68 FAX: 3 (4) 63 19 4 info@macvalves.be MAC VALVES ASIA, INC. NO. 45, DONGYUAN OAD JHONGLI CITY, TAOYUAN COUNTY TAIWAN TEL: 886 (3) 463-6868 FAX: 886 (3) 463-4576 mva@macasia.com.tw MAC VALVES PACIFIC, INC. P.O. BOX 11 PENOSE, AUCKLAND NEW ZEALAND TEL: 64 (9) 634-9400 FAX: 64 (9) 634-9401 www.macvalves.co.nz sales@macvalves.co.nz D BULLET VALVE Our global distribution network is keeping your machines running around the clock around the world MAC VALVES, INC. P.O. BOX 111 30569 BECK OAD WIXOM, MI 48393-7011 E 999BVBA