PSC-301 Pump Stroke Counter

Similar documents
HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

END USER TERMS OF USE

Submersible Pump Model FA10.78Z with 4 Pole, 1740 RPM Motor and Two Vane Impeller

PIPE FITTING ACCESSORIES EFFECTIVE FEBRUARY 5, 2018

VFL-280. Visible Fault Locator. Operating Manual

LU23, LU28 & LU29 Series Quick Start

RAM 1500, 2019 CLASSIC & 2010-ON 2500/3500 INSTALLATION INSTRUCTIONS

TL-105-D COLUMN HEATER

VLF-275 Visible Laser Fault Locator Operating Manual

CANT-Series Cantilever Carts Instruction Manual

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

AXD 530 MicroManometer

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Electric Actuator Installation, Operation & Maintenance Manual

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

ALULIFT Portable Aluminium Gantry Crane Operation & Maintenance Instructions

Effective June 1, 2013 This guide supersedes all previous versions

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Broadband PowerShield. CP27U Models. User Manual

BEAMER Tilt Beam Sensor

COLV-6 SERIES VERTICAL CROSSOVER LADDERS INSTRUCTION MANUAL

AD-7 THERMAL INDICATING AMMETER

A Member of the. Integrated Metering Technologies

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

PIPE FITTING ACCESSORIES EFFECTIVE JANUARY 14, 2019

MS40 MS40/EX Explosion

Advanced Calibration Designs, Inc. Release II

XP88 & XP89 Series Quick Start

HIGH VOLTAGE DIGITAL AMMETER

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Panel Mount Digital Tachometer Model

Thermaltake Warranty / Support Information

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

LU27 Series Quick Start

BP1204 INSTALLATION/OWNER'S MANUAL

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Care and use guide. Contents. page

A Member of the. Integrated Metering Technologies

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

MINISTICK TM UV Germicidal Ultraviolet Light

SUNTURA SOLAR TRACKER

i n s t r u c t i o n m a n u a l

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TIMER/CONTROLLER

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

Safety Sentry Electronic Breakaway Switch

Rig Master Power by Mobile Thermo Systems Inc.

Spy pocket Jeepmeter ope rati ng instructions

MODEL V-24 OWNER'S MANUAL PARTS

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Stainless Steel Kick Bucket and Stand

Model 4482 Waterproof Temperature Probe and Mounting Assembly User's Manual

Veterinary Anesthesia Gas Scavenging System (Active)

SUNTURA HD SOLAR TRACKER

i n s t r u c t i o n m a n u a l

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Warner Electric UNIBRAKE Motor Brakes

FAN POWERED HEPA FILTER UNIT

MS Rev c ( ) DCN0530

2019-ON RAM 1500 INSTALLATION INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Installation / Operation Instructions Sunnex ORION Series Exam Lights

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

User s Manual. Item no. 2561

ASSEMBLY / OPERATION INSTRUCTIONS. Low Profile Motorcycle Dolly

EQUIPMENT OWNERS MANUAL MATTHIESEN HEAVY DUTY SHAKER

INSTALLATION & OWNER'S MANUAL

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

INSTALLATION/OWNERS MANUAL

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

37SCENE 46SCENE 79SCENE

TECHNICAL INFORMATION

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

AXD 510 MicroManometer

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

Installation, Operating and Maintenance Manual

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc.

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

Operating and Service Manual

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Installation Power Management Unit Battery Cables and Battery Harness

COLT CELL BATTERY CHARGER Installation and Operating Instructions

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX)

Transcription:

PSC-301 Pump Stroke Counter 3 PUMP MODEL Operations and Maintenance Manual Rev 1000 WG Industries, Inc. 2825 Creek Bend Drive Friendswood, TX 77546 Ph 713 416 1585 Fax 281 404 9054 Toll Free 800 440 1153 www.wgindustries.com email sales@wgindustries.com or engineering@wgindustries.com

OPERATIONS AND MAINTENANCE MANUAL TABLE OF CONTENTS WGI PSC-301 SECTION 1 Systems General Information 1.A General Information 1.B Unpacking and Inspection 1.C Precautionary Information 1.D Personnel Qualifications SECTION 2 System Description 2.A Pump Stroke Counter 2.B Pump Stroke Switches 2.C Pump Stroke System Capabilities SECTION 3 Installation 3.A Pump Stroke Counter Installation 3.A.1 Pump Stroke Counter Display 3.A.2 Pump Stroke Counter Cables SECTION 4 Theory of Operation 4.A Pump Stroke Counting System SECTION 5 Calibration 5.A Pump Stroke Counting System SECTION 6 Maintenance 6.A Pump Stroke System SECTION 7 Warranty i

SECTION 1 Systems General Information 1.A General Information This manual describes the installation, operation and maintenance of the WGI Model PSC-301 Pump Stroke Counter System. This manual provides the user with information necessary to properly utilize the Pump Stroke Counter. Included here is all of the necessary information and procedures necessary to install and maintain this Pump Stroke Counter instrument. 1.B Unpacking and Inspection Upon receipt of the equipment, assure all items are accounted for on the packing list. If any are missing, immediately inform the shipper. Inspect all items for damage. If any are damaged, immediately inform the freight forwarder and WG Industries, Inc. 1.C Precautionary Information Assure all directions on the packages are followed during unpacking and handling. 1.D Personnel Qualifications This equipment requires experienced personnel to handle, install and maintain it. WGI offers technical training if the Customer desires. SECTION 2 System Description: 2.A Pump Stroke Counter One Pump Stroke Counter with input capacity for three pumps. 2.B Pump Stroke Switches Switches and cable assemblies are furnished by the customer, or the agent of WG Industries. 2.C Counter Capability WGI Pump Stroke counters are capable of a minimum of 8 strokes per minute and a maximum of 240 strokes per minute for each pump. 1

SECTION 3 Installation 3.A Pump Stroke Counter Installation 3.A.1 Pump Stroke Counter The Pump Stroke Counter is mounted in a driller s or choke control panel in a rectangular opening, with dimensions as described in figure 1. Four bolts are used to fasten the Pump Stroke Counter to the panel, which are normally 1 /4 stainless steel hex head bolts with flat washers under the head, and lock washers and nuts behind the panel. Care should be taken not to over-tighten these bolts, as the clear panel behind the front panel can fracture if torque sufficient to distort the stainless front panel is applied. 0.280 4 PLACES 3.156 6.313 8.375 9.125 4.188 4.563 CUTOUT DIMENSIONS PSC-301 3 PUMP STROKE COUNTER 3.313 6.625 FIGURE 1 2

3.A.2 Pump Stroke Counter Cables The cables are provided by either the customer or WGI Industries agents, and should be wired according the diagram in figure 2. The connector for this cable is centered at the lower rear of the Pump Stroke Counter housing. WG INDUSTRIES, INC. CONNECTION SPEC PSC-301 PUMP STROKE COUNTER SECTION 4 Theory of Operation 4.A Pump Stroke Counting System This system is comprised of a Control Head containing the necessary batteries, displays, control and external connector. All power is supplied by a 3.6 Volt battery contained inside the instrument housing. Under normal use this battery should last approximately 5 years. The required input to the Pump Stroke Counter is either a simple switch closure to common, or an open collector driver circuit from external electronic detectors. The input is intrinsically safe, and can only provide a maximum of 52 microamperes under short circuit conditions at each pump connection. The Pump Stroke Counter detects signal closures and openings, and counts them with one increment, while determining the pump rate via an internal microprocessor. The Pump Stroke Counter contains a crystal-controlled real-time clock, with an accuracy of better than 100 parts per million. 3 FIGURE 2

Using the Pump Stroke Counter There are 3 push-buttons(switches) on the front panel, one for power, and one each for clearing the count on each pump. The power switch is an alternate action type; Pressing it will turn the device on, and pressing it again will turn the device off. When the unit is on, there will be a Total Strokes displayed, and when the Mud Pump is operating, the rate will be displayed in the Strokes/Minute window. The other three push-buttons are for individually clearing the Total Strokes counters. Each time the switch is pressed, the count will be cflearen on the corresponding display. SECTION V Calibration 5.A No calibration is required for the Pump Stroke Counter. No calibration is required for the Pump Stroke Counter. The device contains an internal crystal clock, which is used for determining the pump stroke rate. SECTION VI Maintenance 6.A The internal battery will have to be replaced at the end of its life. The internal battery will have to be replaced at the end of its life. This will normally be several years a normal life is approximately 5 years but the life can be shortened with extremes of temperature. When the display segments appear to no longer have a high contrast, it is time to replace the battery. Turning the unit off when not in use will extend the battery life. 4

SECTION VII Warranty WG Industries, Inc. (WGI) warrants the unit for a period of one year from the date of shipment. The warranty covers replacement of those parts having defects in material or workmanship when used for Normal Oilfield Usage. For the purpose of this warranty, this is defined as normal oilfield monitoring applications. WGI will not honor the warranty if any evidence of tampering, misuse or intrusion is indicated, except by a WGI authorized agent. WGI will replace or repair as it deems appropriate any products covered by this warranty, after WGI s examination discloses to its satisfaction that the Pump Stroke Counter is defective and an adjustment is required. All products accepted under the provisions of this warranty shall be shipped prepaid to WGI or it s agents, and returned to the customer prepaid by WGI. WGI will not be responsible for repair or replacement of products resulting from improper handling, storage, installation, misuse, negligence or use in a manner contrary to the recommendations of WGI. WGI warrants only the products that it sells but manufactured by others to the extent of the other manufacturer s warranties. All warranty claims shall be made in writing to the nearest WGI agent or factory representative. WGI makes no other warranty of any kind, expressed or implied, and all implied warranties of merchantability or fitness for a particular purpose which exceeds WGI s aforementioned obligation are hereby disclaimed by WGI and excluded from warranty. This Warranty is non transferable, and WGI shall not be liable for any damage, or loss of property, or injury to persons, resulting from the use of any of WGI s products or equipment whether such damage, injury or loss results from, or is caused by manner of use, defects in materials, or workmanship or otherwise. 5

WGI The WGI Pump Stroke Counter (Model PSC-301) simultaneously monitors and displays the total accumulated pump strokes and the stroke rate, of three individual mud pumps. The stroke rate and the total stroke count are independently displayed at all times, with the stroke count being updated at every stroke, as is the stroke rate. The WGI battery is designed to operate continuously for 5 years. No calibration is required. The quartz crystal oscillator provides high precision stroke rates with no appreciable drift. The WGI Pump Stroke Counter is designed to be intrinsically safe, and is built to operate in Class I Division II hazardous locations. The stainless steel enclosure is completely sealed. Labels are permanently engraved on the front panel. The entire package is constructed to operate in harsh environments and high vibration conditions encountered in normal drilling rig operations. Specifications: Dimensions: Weight Case Material Front Panel Control Stroke Rate Range 10.125 L x 7.625 W x 3 D (20.3x20.3x10.2 cm) 8 lbs (3.63 Kg) Stainless Steel Power on/off, pump count clear (3 pushbuttons) 8 to 240 strokes per minute (SPM) Total Accumulated Strokes 9999 strokes (Counter will then roll over to 0) Battery Battery Life External Power Display Time Base Pump Switch Operating & Storage Temperatures 3.6 Volt Lithium Cell 5 year s continuous operation under normal usage None Required Liquid crystal display for total strokes & SPM Quartz Crystal oscillator Any dry contact, open collector or pulsed voltage inputs. For open collectors, the maximum permissive voltage presented at the connector is +3.6V. For pulsed voltages, the voltage range is ±25 VDC. The input is ESD protected to ±15kv for harsh industrial environments. -40º to +75º C 6