PRO series programmer

Similar documents
i n s t r u c t i o n m a n u a l

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

FILTRON 1-10 (DC/AC) BERMAD Irrigation

WIRING / CONNECTION GUIDE (20-PIN) SECONDARY CONNECTOR

710-xxxp Propagation & Irrigation Battery Operated Controller

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

Lt.Blue/Black. White. Orange. LED Blue LED Yellow LED Red

Battery Operated Advanced Computerized Irrigation Controller Installation and Operating Instructions

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

Model APS-101N Installation Manual

i n s t r u c t i o n m a n u a l

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

Model PRO 9644a Installation Manual

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Model AS-9234E. Owners Guides

WVC. Wireless Valve Controller. Multiple Station Battery Powered Irrigation Controller. Owner s Manual and Installation Instructions

DEEP SEA ELECTRONICS PLC

Model AS-9234 Owners Guide Upgrade Vehicle Security & Remote Start System

REVISION HISTORY REVISION HISTORY

12V PROGRAMMABLE POWER OUT

DEEP SEA ELECTRONICS PLC

June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

3200NT Timer Service Manual

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

AS-1585 SH Installation Guide

Model K20 installation guide. ProSecurity

Model PRO 9246CH Installation Manual

QUICK INSTALLATION GUIDE

ECONOMISER SERIES E2T USER MANUAL

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

Red #22 Power. Red #14. Brown #18. Ign/Acc/Start. White#14. Tachometer Foot-Brake Door Pin Pos Trunk/Hatch (open) (-) while running Lock Arm

Nortoft Electronic A/S, Sejrupvej 38, DK 7323 Give. Program Rain User Manual

Automatic Sensor Faucet Installation Manual CAT ALL-IN-ONE AUTO VALVE FAUCET HORIZONTAL WATER SPOUT. Revision

Indoor air quality sensor.

Model PRO-9675FT4 Owner's Manual

Ezyfit AC Controller INSTRUCTION BOOK 2 & 4 STATION UNITS

To ensure proper installation, digital pictures with contact information to before startup.

Installation and User Manual. with RAIN SENSOR.

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

INSTRUMENTATION & CONTROL

e-ask electronic Access Security Keyless-entry

Model PRO-9776 Owner s Manual

Model AX-510 Owner s Manual

ALEX-TRONIX SMART CLOCK TM. BATTERY POWERED TEMPERATURE BUDGETING CONTROLLER MANUAL Patent Pending A DIVISION OF GNA INDUSTRIES, INC.

i n s t r u c t i o n m a n u a l

Model CSI-300 Owner s Manual

AUTOMATIC SPRINKLER TIMER

4.2 Component Identification

Model JR-2 Current Interrupter. Operating Manual (Revised August 19, 2011)

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

Model APS-596 Owner s Manual

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

"WE'VE GOT THE EDGE ON SECURITY" INSTALLATION MANUAL AL-700 ATV / AL-900 ATV / AL-1000 ATV

INSTALLATION GUIDE Table of Contents

The ECLIPSE #9800 & The ECLIPSE #9800WC

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

INTRODUCTION. Specifications. Operating voltage range:

Model APS-25CH Installation Manual

Operators Guide: RoboSign Stop/Go Traffic Control System

Model: APS-610a Owner s Manual 4 Button Remote Security System with Dual Stage Shock Sensor

Congratulations. You ve just purchased the most advanced flasher available on the market today. This

IB INTERNATIONAL Pty Ltd OCMIS INSTRUCTION MANUAL AQUA SYSTEM 3

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

" MANUALLY OVERRIDING YOUR SYSTEM

Model APS-25N Installation Manual

Installing the gate post bracket with the cardboard arm template

Smart Wi-Fi Sprinkler Timer and Flow Meters

i n s t r u c t i o n m a n u a l

Owner s Guide CA2LED5

2005 Directed Electronics, Inc. Vista, CA N426V 07-05

Nortoft Electronic A/S Sejrupvej 38 Sejrup DK-7323 Give Denmark

CA-210 Installation Instructions

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Installation Guide TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER

Doc: MGA-µS Version: 1.0 Page 2 of 6

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

LUBRICATION PUMP PMP CENTRAL LUBRICATION

PRODUCT GUIDE HCF900A DOCUMENT NUMBER REVISION DATE

Model PRO 9649 Owner s Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

TIP SHEET T0937. Installation Tips For RS00/PS00 + ADS-TBSL-PL + SPDT

twin engine two battery bank split charge system

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

Instruction Manual MINI IRRIGATION CONTROLLER.

IRRIGATION CONTROLLER

PRODUCT GUIDE FT-DC2-S DOCUMENT NUMBER REVISION DATE

MSD Programmable Shift Controller PN 75591

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

SURE TRIP SLT-201 SECONDARY TEST SET

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator.

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

TIP SHEET T0937. Installation Tips for RS00 + Passlock-sl2(4) + SPDT

Transcription:

PRO series programmer Instructions for use and programming Thank you for using the RPE PRO Series battery programmer. The PRO Series controller is equipped with the most modern and easy to use programming technology. The following instructions explain how to use the programmer; You should pay particular attention to the NOTES which provide important tips for the programmer usage.

PROGRAMMER SPECIFICATIONS The PRO series programmer is able to operate simultaneously a MASTER valve and an irrigation Controller using RPE latching 9V solenoids. The controller is watertight, therefore it can be installed inside sumps. But it is important to dry the programmer before opening the battery and programming covers. It is also important to make watertight all the connections in order to preserve all electronic components from faults or breakdowns Black wire is common to all valves Master Valve Red wire zone 1 Green wire zone 2 INSTALLATION INSTRUCTIONS Place the valve in the well, connect the controller support to the RPE Bistable solenoid, connect the cables to the latching solenoids. For proper installation of the programmer with RPE valves is necessary that the colour of the wires between the solenoid and the programmer are connected correctly: PRO SERIES 100-200-400 Do not cut if a climate sensor is not to be fitted Blue wire zone 3 Yellow wire zone 3 NOTE: The brown wire can also control a 9V latching relay to activate a pump or other utilities. Do not connect the 9V battery until you have connected the various zone cables.

Connect the 9 volt ALKALINE battery, close the lid and check the battery charge through the LED in the front panel. The display is a sequence of LED flashes, coded as follows: GOOD LEVEL LOW LEVEL INSUFFICIENT LEVEL (battery charged) three consecutive flashes (battery charge limit) two consecutive flashes (battery flat) one flash With a GOOD battery level the programmer will work correctly. If the charge is INSUFFICIENT the programmer will not function and you will have to replace the battery. CONNECTING THE RAIN SENSOR The PRO series programmer can be connected to a MINI CLICK sensor (not included) with wires. Cut the white wires and connect them to the two wires of the rain sensor using waterproof connectors. The programmer is compatible with a normally closed (NC) climate sensor that does not need power. If the climate sensor is activated during an irrigation cycle, the execution of the program will be stopped, until the inactivity condition of the sensor. PLANNING PANEL NOTE: The use of NON-ALKALINE or a DAMAGED battery could result in serious permanent damage to the electronic circuit. It is important to insert the battery with the programmer completely dry: if moisture enters the compartment, the battery may deteriorate. During the battery test, a closing pulse is sent to the solenoid valves. For this reason the solenoids should be connected to the programmer before you insert the batteries.

SELECTOR Irrigation delay : means the time that must elapse between the cycle memory and the first irrigation. SELECTOR Irrigation frequency : means the time that must elapse between the first and subsequent irrigation. SELECTOR 1-2-3-4 Zone : means the amount of irrigation time in the selected area. MAN BUTTON: has the function to initiate an irrigation cycle with immediate effect and for the pre-set time as stored in the program. NOTE: If you run a manual watering cycle before storing the program, the programmer will run with default time of 30 secs. SAVE BUTTON: has the function of storing the selected cycle (position), and will commence counting the time delay. NOTE: The memory function cannot be activated if the battery test or an irrigation cycle is in progress. The stored irrigation data timings are also used for manual watering cycles. PROGRAMMING The setting is done through the dials on the front panel. To create an irrigation program rotate the selectors to select the desired values. The delay time which is selected with Irrigation delay will start from the moment you press SAVE button. NOTE: Performing a manual cycle after saving a program does not delay the commencement of the first automatic irrigation cycle. The time selected with the selector Irrigation frequency will be counted from the beginning of the first irrigation until the beginning of the subsequent irrigation. NOTE: If you set a time of frequency lower than the total time of irrigation, the irrigation programmer will not run the excess irrigation time. (e.g.: frequency 1 hour, duration 90 min. - irrigation time will be for 90 min and the second cycle will not start). The time selected with the selector 1-2-3-4 Zone will be used to maintain the valve open on the affected area. The execution of various irrigation areas will occur starting from zone 1 to zone 4 (where applicable). NOTE: The master valve opens a few seconds before the first zone is activated in the program and remains open for as long as irrigation of various areas (1-4) is required.

After setting the various operating times, press and hold the SAVE button for at least three seconds. In this way the programmer will save the data set and will begin to count the delay time before activation. NOTE: After pressing the SAVE button for three seconds, the controller s LED will flash three times. This indicates successful data storage and the commencement of delayed start counting. If, after storing the program, new irrigation data is selected, the programmer does not store the new selection until you press the SAVE button. You cannot save the program during an irrigation cycle or during the initial battery test. MANUAL IRRIGATION You can run at any time a manual mode irrigation by pressing and holding the MAN button for three seconds. The run time used will be that stored for the automatic program. The confirmation of the start of the manual cycle will be indicated by two fast flashes of the LED on the front panel. To stop watering before the end of the set time press and hold the MAN button for three seconds. Confirmation of the manual cycle stopping is shown by two quick flashes of the LED on the front panel. NOTE: You cannot run the manual cycle during the battery test or during an automatic cycle. If a manual cycle is started before the data storage, default factory times will be set (30 sec). PROGRAMMER MEMORY The controller has a volatile type of memory that is erased when the battery is replaced.

PROGRAMMER POWER SUPPLY The programmer works only with 9V ALKALINE BATTERIES, be sure NOT to use rechargeable or other non-alkaline batteries. The use of other batteries than those prescribed will invalidate the warranty. A 9-volt alkaline battery can power the system for one year. NOTE: If the programmer is not used for a long period, remember to remove the battery to prevent any potential acid leakage damaging the controller. IRRIGATION PROGRAM SET DATE: --------------- TIME: --------------------- START DELAY FREQUENCY DURATION TIME ZONE 1 DURATION TIME ZONE 2 DURATION TIME ZONE 3 DURATION TIME ZONE 4 SET PROGRAM - TRACEABILITY FORM Cut the paper along the dotted lines, fill in the required values, keep it to check the settings stored in the programmer. www.rpesrl.it

IRRIGATION PROGRAM SET DATE: --------------- TIME: --------------------- START DELAY FREQUENCY DURATION TIME ZONE 1 DURATION TIME ZONE 2 DURATION TIME ZONE 3 DURATION TIME ZONE 4 www.rpesrl.it

IRRIGATION PROGRAM SET DATE: --------------- TIME: --------------------- START DELAY FREQUENCY DURATION TIME ZONE 1 DURATION TIME ZONE 2 DURATION TIME ZONE 3 DURATION TIME ZONE 4 www.rpesrl.it

rpe - 06/2011 RPE s.r.l. Via S. Ambrogio, 3 22070 Carbonate (CO) - Italy Tel. +39 0331 832515 Fax +39 0331 832501 info@rpesrl.it - www.rpesrl.it