ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Similar documents
ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB i-bus KNX DG/S x DALI-Gateway Basic

Mini contactors B6, BC6 with 3 pole

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Manual motor starter magnetic only MO325

Thermal overload relay TF65 and TF96

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Valve Drive EnOcean SE/K Product Manual

Manual motor starters Overview and benefits

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starter MS116

Manual motor starter MS132

Manual motor starter MS116

Manual motor starter MS132

Manual motor starter MS132

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Mini Contactors Applications and Segments

Selective main circuit breakers S 750 series Technical Data

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

Product information. ECOSS Electronic compact starter for wound rotor drives

Surge arrester POLIM-C.. HD

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

ZP2.5-PE Spring Terminal Block Ground

Surge arrester POLIM-H.. ND

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Service Fieldbus Engineering and Consulting

Surge arrester POLIM-H..SD

EAS822 (Contrac) Power Electronic Unit

ZP2.5-4P Spring Terminal Block Feed-through

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

TwinLine The new system of wall-mounting and floor-standing cabinets

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Traction systems for Light Rail Vehicles Selected references

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

Moving Coil Indicators with direct temperature sensor input

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

Motor Starter Reverse MSR22-FBP

The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Thermal Overload Relays

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

RSD100 (Contrac) Electrical Linear Actuator

DBL distribution blocks 3x1 pole

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

When grids get smart ABB your partner for developing Smart Grids solutions

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

Panorama. Contactors Motor protection Accessories

Training Courses Regional Competence Center. ABB i-bus KNX KNX Certified Courses Energy Monitoring

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

LV Capacitors QCap-L series Capacitors for power factor correction

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Shut-off valves and accessories for pressure measuring instruments

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

ZS35 Screw Clamp Terminal Blocks Feed-through

Voltage limiting device HVL

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

Voltage limiting device HVL

TriLine PowerModules Overview with Planing Examples

ZS50-PE Screw Clamp Terminal Blocks Ground

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ZK4-PE PI-Spring Terminal Blocks Ground

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

Product Brochure. Grip Tight ball bearings

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

Transcription:

Technical Data 2CDC508163D0201 ABB i-bus KNX Device description The Magnetic Contact EnOcean is a surface mounted device for windows or doors. Its purpose is to recognize the opening or closing of windows or doors. The EnOcean magnetic contact communicates on this with a gateway via radio. The frequency is 868.3 MHz. The interior range is up to 30 m, typically 5 10 m, depending on the structural conditions. The window contact supplies itself with power via a solar cell and does not require a battery or other supply voltage. The learn button is located in the interior of the device and can be reached via the rear side or by removing the upper section from the lower section. When using the ABB i-bus KNX/EnOcean Gateway EG/A 32.2.1, to link to the KNX-Bus, the signal strength can be measured with the ABB i-bus Tool.

Technical Data Power supply via integrated solar cell; no external power supply necessary Illumination 50 100.000 Lux Operation time in darkness (at 25 C) approx. 175 hrs.; min. 90 hrs. (if energy storage fully charged transmission of telegram every 25 min on average) 1 Time until operational when battery is empty typically 2.5 min at 400 lux and 25 C Required recharge time at 200 lux, within 24 hrs, for 1.8 hrs (approx. 110 min) (+/ 20 %) ongoing operation at room temperature (25 C) Mounting adhesive or with screws (not included) at the window or door frame Distance of magnet to transmitter module less then 5 mm Operating elements EnOcean Teach-In Button in the transmitter module. Access via hole in rear side of the lower section or by removing the upper section from the lower section Display elements LED inside the transmitter module Diplays the sending of signals Antenna pre-installed helical antenna Frequency 868.3 MHz EnOcean Equipment Profile (EEP) D5-00-01 Interior range EnOcean up to 30 m, typically 5-10 m; dependent on building structure Temperature range Operation Storage Transport 20 C...+ 60 C 20 C...+ 60 C 25 C...+ 70 C Shelf life in absolute darkness 24 months after delivery Ambient conditions maximum air humidity 93% no condensation allowed Protection type IP40 to EN 60 529 Pollution degree 2 to EN 60 664-1 Installation position any (sufficent illumination has to be ensured) Design Transmitter module dimensions (H x W x D) Magnet dimensions (H x W x D) Material Colour Weight 0.1 kg CE-Conformity according to EN 60730 RoHS conformity compliant with RoHS directive (2011/65/EG) 15 x 19 x 110 mm 5 x 10 x 37 mm plastic PC/ABS white 1 Full performance of the energy storage is achieved after several days of operation (up to two weeks) at good illumination level. Performance degrades over life time, especially if energy storage is exposed to higher temperatures. 2 2CDC508163D0201 MKE/A 1.868.1

Dimension Drawing 2CDC 082 002 F0014 2CDC 082 001 F0014 Dimension Drawing MKE/A 1.868.1 2CDC508163D0201 3

Mounting 1 Transmitter module 2 Marking for positioning 3 Magnet with housing 4 Distance of transmitter module to magnet (< 5 mm) Mounting The transmitter module is attached above/next to the window or door with screws or adhesive strips. In order to screw it tight, the upper section of the transmitter module has to be removed from the lower section. The magnet can be attached in its housing to the door or the window. In doing so, the positioning, marked by an indentation next to the solar cell on the transmitter module, has to be executed correctly. The magnet has to be as near as possible to the marking. Alternatively, the magnet can be taken out of its housing and place into a hole in the window or door. In doing this, however, the correct distance to the transmitter has to be observed. Depending on the material of the door or window, the transmitting power of the EnOcean magnetic contact may decrease. It is recommended to perform a measurement of the signal strength before the final mounting. 4 2CDC508163D0201 MKE/A 1.868.1

Operation and teach-in The learn button is located in the interior of the transmitter module. It can be pushed through the rear side with a thin object. The upper section of the transmitter module must be removed and the interior button activated, for the teach-in on a mounted device. Important notes Installation and commissioning of the device may only be carried out by trained electricians. The relevant standards, directives, regulations and instructions must be observed when planning and implementing the electrical installation. Protect the device against moisture, dirt and damage during transport, storage and operation! Do not operate the device outside the specified technical data (e.g. Temperature range)! Important The KNX/EnOcean Gateway uses the 868 MHz frequency band for the transmission and reception of data which has been approved for EnOcean in the European Union, Switzerland, Turkey and Norway. Further details can be found in the EnOcean Radio Approval Overview: www.enocean.com/fileadmin/redaktion/pdf/tec_docs/enocean_radio_approvals_overview_may2014. pdf Please ensure that the product is suitable for application in the intended country of final installation and use before purchase. Cleaning Should the device become soiled, it may be cleaned with a dry cloth. If this does not suffice, a cloth lightly moistened with soap solution may be used. On no account should caustic agents or solvents be used. Maintenance The device is maintenance free. Should damage have occurred, e.g. due to transport or storage, no repairs should be carried out. MKE/A 1.868.1 2CDC508163D0201 5

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of this contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Order Number 2CDC508163D0201 (06/2015) Copyright 2015 ABB All rights reserved