Ducted Split System Air Conditioners

Similar documents
Air Cooled Packaged Units

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Ducted Split System Air Conditioners

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

Air Cooled Packaged Units Technical Data

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

OUTDOOR UNIT CONTROLLER (OUC)

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

D M S 760 C01 A A 1 1

Hitachi Inverter Wall Split Air Conditioning

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TRI-CAPACITY PACKAGE UNIT

AHN 064 to 304 EHN/CHN 064 to 304

Landmark Rooftop Packaged Units

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

DC INVERTER DUCTED AIR CONDITIONERS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Hitachi Inverter Wall Split Air Conditioning

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

Tons BTU/h S.E.E.R* E.E.R** HSPF

RCD Air Cooled Condensing Unit (50/60 Hz)

WQL/WQH/WQRC 524 to 1204

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Hitachi Inverter Wall Split Air Conditioning

HCH6. Product Specifications

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

UMXCA/UMXCBA ECVA/ECVBA

PCB COMMERCIAL SERIES

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

DESCRIPTION FEATURES

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

technical catalogue tetris KW Chiller and heat pumps air/water

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

PHR5. Product Specifications

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Highline 260i EC Waterside Fan Coil Unit

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Bosch BOVA Split System Heat Pump

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

PHB SERIES 7-1/2 and 10 TON

IDENTIFICATION ACCESSORIES DESCRIPTION

The World Leading Air-conditioning Company

CAC SERIES 12-1/2 Thru 20 Ton

Concealed Ducted Split Series R22

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Air-Cooled Liquid Chiller with integrated hydraulic module

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

AQVSL/AQVSH STAR 85 to 140

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

... RTU Technical Manual. Packaged Air Conditioning Unit...

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

GUIDE SPECIFICATIONS. ES Series R-410A

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

FFQN-C, FCRN-E, FFRN-C

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CS Series Condensing Units

Transcription:

Technical Data ISD 380, 465, 570, 670, 840, 950 Cooling Capacity 37.6kW - 94.9kW Heating Capacity 35.9kW - 90.1kW

Contents ISD 380 950 General 3 Applications 4 Air Flow Selection 4 Features Refrigerant R410A 4 Economical 4 Efficient 4 Quiet 4 Performance 4 Durable 4 Low Maintenance 4 Soft Starting 4 Control Option 5 Insulation 5 Self Diagnostics 5 Optional Equipment Outdoor Unit 5 Indoor Unit 5 Safety Features 5 Compressor 5 Refrigeration Piping 5 Wiring 5 Plug Fan Advantages 6 Digital Version Digital Scroll Compressor 6 Extended Capability 6 PERFORMANCE DATA Cooling Capacity (kw) 7 Indoor Air Flow Correction Factors @ nominal conditions Pipe Length Capacity Loss 8 Heating Capacity (kw) 9 Air Handling 10 Sound Levels 12 DIMENSIONS (mm) ISD Indoor Units 14 OSA Outdoor Units 18 SPECIFICATIONS 21 8 Page 2 of 22

ISD 380 950 Series The ISD indoor unit, together with its associated OSA outdoor unit, provides a reverse cycle (heat pump) split system air conditioner designed and developed to comply with and exceed AS/NZS 3823 specified conditions. Page 3 of 22

ISD 380 950 Series Applications These units have been specifically developed for air conditioning of commercial premises, e.g. offices, motels, shops and restaurants AIR FLOW SELECTION If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less. High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Refrigerant R410A Each complete system uses refrigerant R410A which has a zero ozone depletion potential. Economical These ISD/OSA systems have two independent refrigeration circuits to provide the flexibility and economy of two stage operation, i.e. utilising one or two circuits as conditions vary, plus the advantage of staggered starting. Efficient Each outdoor unit incorporates a high efficiency scroll compressor. ISD 380 indoor units include high efficiency EC motors. Heat exchange coils incorporate inner grooved (rifled) tube for better heat transfer. Quiet ISD 380 models: Each integral high efficiency electronically commutated (EC) motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. Outdoor noise is a function of how hard the unit needs to work. When the outdoor unit is not running at maximum capacity in mid- season the outdoor fan speed and noise reduces. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Performance Use of forward curved fan enables fine tuning of the indoor unit to match the supply air requirements. ISD 380KB-P models: Use of backward curved plug fan enables fine tuning of the indoor unit to match higher static pressure supply air requirements. EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Durable The indoor and outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. The outdoor unit s cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 44). External fasteners are stainless steel. Heat exchange coils comprise aluminium plate fins on mechanically expanded rifled copper tube. Coil protection guards are supplied. The indoor unit s cabinet is constructed from high grade galvanised steel and also includes a polyester powder coated drain tray. Low Maintenance EC motor models* - commissioning and maintenance costs are reduced through use of a fan that requires no pulley and belt adjustments or changes like traditional fans. Page 4 of 22

ISD 380 950 Series Soft Starting EC motor models* - EC motors are soft starting therefore have none of the problems associated with high in rush current. Control Option EC motor models* - Fixed and stable air flows can be achieved through use of a differential pressure transducer and controller (supplied by others) to compensate for varying duct static pressures caused by dirty filters or modulating dampers. Commissioning is also made easier. The system is set up for the EC motor to be controlled variably by a 0 10 volt DC signal that can be supplied either by OPTIONAL EQUIPMENT a BMS system, a sophisticated controller or temperzone s optional TZT-100 Controller; the optional Signal Isolator will be required in this instance for ISD 380KBY models. Systems using UC6 controller* are BMS compatible with multi-unit control possible either via digital and analogue signals or via Modbus. Refer to temperzone for protocols available. Insulation Closed cell foam insulation has been used in the indoor unit s cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1999) and BS 476 parts 6 & 7. COMPRESSOR Self Diagnostics Systems that includes a controller (UC6) have a 7 segment LED display to indicate faults and running conditions. Many operating status conditions (including history) can be determined, without gauges, simply by using the optional UC6 Service Interface graphical display tool. Note: OSA 870/950 use OUC4 controller. * Refer Specification tables (p.19/20) to identify applicable models Outdoor Unit: UC6 Service Interface tool (OSA 310 670 only) Indoor Unit: 1. Vertical supply air configuration. 2. Filters - EU4/G4 rated. 3. temperzone TZT-100 Room T/stat, or SAT-2 (24V) Controller kit (for non-digitals). 4. Signal isolator (Item no. 201-000-129) for using EC motors in a 0 10V DC continuously variable speed mode on ISD 380KBY models. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Compressor minimum run time to ensure oil return. 8. Crankcase heater prevents liquid refrigerant condensing in the compressors during the 'off' cycle. 9. Phase rotation protection device. 10. 24V control circuit Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. REFRIGERATION PIPING The standard unit allows for a line length up to 60 m or more ; refer specifications table pages 19 & 20. Max. height separations between units are: Outdoor unit above indoor unit: 20m Outdoor unit below indoor unit: 20m. Each OSA is shipped from the factory with a charge of R410A refrigerant sufficient for a 10m line length. Liquid and suction service valves are provided. Accurator expansion devices control the flow of refrigerant. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. WIRING The electrical supply required is: 3 phase 380 415 V a.c. 50 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. A control panel, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system complies with the requirements of the Regulatory Compliance Mark (RCM) for electrical safety (AS/NZS 60335.2.40) and EMC (AS/NZS CISPR.14). Page 5 of 22

ISD 380 950 Series Plug Fan Advantages The ISD 380/570/670 KB-P models with EC motor and backward curved plug fan design have the following advantages: - higher static pressure performance (refer page 4) - quieter than conventional fan (refer page 3); a large aperture supply air spigot reduces exit velocities and therefore less noise down ductwork. Each EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. - lower installation cost due to a large supply air spigot which lessens the need for duct transitions. - EC motors are soft starting therefore have none of the problems associated with high in-rush current. Digital Version Digital Scroll Compressor A digital version of the some outdoor units (OSA 380) is available that includes one fixed and one digital compressor. This provides an enhanced variable capacity ability that enables closer control of room temperature. Digital compressors have proven very reliable because of their design simplicity. Electrical harmonic noise is very low. Extended Capability Digitals are particularly suitable for applications requiring full or high proportions of fresh air, VAV, close control and supply air temperature control. - commissioning and maintenance costs are reduced through use of a fan that requires no pulley and belt adjustments or changes like traditional fans. - fixed and stable air flows can be achieved through use of a differential pressure transducer and controller (supplied by others) to compensate for varying duct static pressures caused by dirty filters or modulating dampers. Commissioning is also made easier. - the system is set up for the EC motor to be controlled variably by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone's optional TZT-100 Controller. - significant power savings are possible by slowing the fan during low occupancy or after hours (75% airflow 55% power use). Page 6 of 22

Performance Data COOLING CAPACITY (KW) Total = Total Capacity (kw). Sens. = Sensible Capacity (kw). E.A.T. = Entering Air Temperature. = Nominal Capacity (kw). Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity. See over for Indoor Air Flow Correction factors > Models Indoor Unit Outdoor Unit ISD 380KB-P * OSA 380 ISD 380KBY OSA 380 ISD 465KB OSA 465 ISD 570KB-P * OSA 570 ISD 570KB OSA 570 ISD 670KB-P * OSA 670 ISD 670KB OSA 670 ISD 840KB OSA 840 ISD 950KB OSA 950 Indoor Fan Air l/s 2100 2100 2550 3100 3100 3600 3600 4500 5000 Indoor coil E.A.T. Outdoor coil entering air temperature C D.B. W.B. D.B. 23 27 31 35 39 43 C C Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 15 21 36.4 28.5 35.9 28.7 34.9 28.2 33.2 27.3 31.1 25.8 28.3 23.8 17 23 38.3 28.1 37.9 28.1 36.8 27.7 35.2 26.8 33.0 25.4 30.3 23.6 19 27 40.3 32.2 39.8 32.2 38.7 31.8 37.1 30.8 34.9 29.3 32.2 27.4 21 31 42.2 38.1 41.7 38.2 40.7 37.7 39.1 36.6 36.8 35.0 34.1 32.8 15 21 36.8 29.1 36.4 29.1 35.3 28.6 33.7 27.6 31.5 26.1 28.7 24.1 17 23 38.8 28.5 38.4 28.5 37.3 28.0 35.7 27.1 33.5 25.8 30.7 23.9 19 27 40.8 32.6 40.3 32.7 39.3 32.2 37.6 31.2 35.4 29.7 32.6 27.7 21 31 42.8 38.6 42.3 38.7 41.2 38.2 39.6 37.1 37.4 35.5 34.6 32.2 15 21 43.7 34.6 43.2 34.5 41.9 33.9 40.0 32.8 37.4 31.0 34.0 28.6 17 23 46.1 33.8 45.5 33.8 44.2 33.2 42.3 32.2 39.7 30.5 36.4 28.3 19 27 48.4 38.7 47.8 38.7 46.5 38.2 44.6 37.0 42.0 35.3 38.7 32.9 21 31 50.7 45.8 50.1 45.9 48.9 45.3 46.9 44.0 44.3 42.0 41.0 39.4 15 21 55.5 43.9 54.8 43.8 53.2 43.1 50.8 41.6 47.4 39.3 43.2 36.3 17 23 58.5 42.9 57.8 42.9 56.2 42.2 53.7 40.8 50.4 38.8 46.2 36.0 19 27 61.4 49.1 60.7 49.2 59.1 48.5 56.6 47.0 53.3 44.8 49.1 41.7 21 31 64.4 58.2 63.6 58.3 62.0 57.5 59.6 55.9 56.3 53.4 52.1 50.0 15 21 55.1 43.5 54.4 43.5 52.8 42.7 50.4 41.3 47.0 39.0 42.9 36.0 17 23 58.0 42.5 57.3 42.5 55.7 41.8 53.2 40.5 50.0 38.5 45.8 35.7 19 27 60.9 48.8 60.2 48.8 58.6 48.1 56.1 46.6 52.9 44.4 48.7 41.4 21 31 63.9 57.7 63.1 57.8 61.6 57.0 59.1 55.4 55.8 53.0 51.6 49.6 15 21 64.3 50.8 64.4 50.7 61.6 49.8 58.7 48.1 54.9 45.5 50.0 42.0 17 23 67.7 49.6 66.8 49.6 65.0 48.8 62.1 47.3 58.3 44.9 53.4 41.6 19 27 71.1 56.9 70.2 56.9 68.4 56.1 65.5 54.4 61.7 51.8 56.8 48.3 21 31 74.5 67.3 73.6 67.4 71.8 66.5 68.9 64.6 65.1 61.8 60.2 57.8 15 21 64.7 51.1 63.9 51.1 62.0 50.2 59.1 48.5 55.3 45.8 50.4 42.3 17 23 68.1 50.0 67.3 50.0 65.4 49.2 62.6 47.6 58.7 45.2 53.8 41.9 19 27 71.6 57.3 70.7 57.3 68.9 56.5 65.9 54.8 62.1 52.2 57.2 48.6 21 31 75.0 67.8 74.2 67.9 72.3 67.0 69.4 65.1 65.5 62.2 60.7 58.2 15 21 84.9 58.6 83.3 57.5 80.6 55.9 77.9 54.8 75.4 53.7 71.7 52.6 17 23 89.4 63.0 87.0 61.8 80.6 60.6 81.3 59.4 78.9 58.2 74.8 57.6 19 27 93.6 70.0 90.8 68.6 87.7 67.3 84.7 66.0 82.1 65.3 77.9 64.7 21 31 98.2 76.2 95.1 74.8 91.6 74.1 88.9 72.6 86.3 71.9 82.7 71.2 15 21 95.1 67.4 93.4 66.1 90.3 64.2 87.3 63.0 84.4 61.7 80.3 60.5 17 23 100.2 72.4 97.4 71.0 90.3 69.7 91.1 68.3 88.3 66.9 83.8 66.2 19 27 104.8 80.4 101.7 78.9 98.2 77.4 94.9 75.9 92.0 75.1 87.3 74.4 21 31 110.0 87.6 106.6 86.0 102.6 85.1 99.6 83.5 96.6 82.6 92.6 81.8 * EC Plug fan version Page 7 of 22

Performance Data INDOOR AIR FLOW CORRECTION FACTORS @ NOMINAL CONDITIONS Indoor Air Flow (%) -20-10. Rated +10 Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 PIPE LENGTH CAPACITY LOSS On Cooling Cycle due to Pressure Drop Note: Loss percentage is approximate only. No allowance made for vertical piping. System Performance Loss per additional 10m beyond first 5m. Suction Pipe Size OD Additional Pipe Length to allow per Bend Long 90 Radius (2 x pipe dia.) ISD 380 / OSA 380 2.1 % 22 0.50 m ISD 465 / OSA 465 2.1 % 22 0.50 m ISD 570 / OSA 570 1.5 % 28 0.61 m 0.7 % 35 0.76 m ISD 670 / OSA 670 1.5 % 28 0.61 m 0.7 % 35 0.76 m ISD 840 / OSA 840 1.0 % 35 0.76 m 0.8 % 41 0.80 m ISD950 / OSA 950 1.0 % 35 0.76 m 0.8 % 41 0.80 m Page 8 of 22

Performance Data HEATING CAPACITY (KW) G N = Gross Heating Capacity kw, based on nominal air flow. = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw). Models Indoor Entering Air Temp. C Outdoor coil entering air temperature C D.B. Indoor Unit Outdoor Unit D.B. -5-3 -1 1 3 5 7 9 G N. G N. G N. G N. G N. G N. G N. G N. ISD 380KB-P * OSA 380 ISD 380KBY OSA 380 ISD 465KB OSA 465 ISD 570KB-P * OSA 570 ISD 570KB OSA 570 ISD 670KB-P * OSA 670 ISD 670KB OSA 670 ISD 840KB OSA 840 ISD 950KB OSA 950 15 26.3 23.7 28.5 25.6 30.4 27.1 32.4 27.9 34.4 29.4 36.9 35.1 39.3 39.3 41.2 41.2 20 25.8 23.2 27.9 25.1 29.8 26.6 31.8 27.3 33.7 28.8 36.2 34.4 38.5 38.5 40.4 40.4 25 24.8 22.4 26.9 24.2 28.7 25.6 30.6 26.3 32.4 27.7 34.9 32.8 37.1 37.1 38.9 38.9 15 26.5 23.8 28.7 25.8 30.6 27.3 32.6 28.0 34.6 29.6 37.2 35.3 39.5 39.5 41.5 41.5 20 26.0 23.4 28.1 25.3 30.0 26.7 32.0 27.5 33.9 29.0 36.4 34.6 38.8 38.8 40.7 40.7 25 25.0 22.5 27.1 24.4 28.9 25.7 30.8 26.5 32.7 27.9 35.1 33.0 37.3 37.3 38.2 38.2 15 30.0 27.0 32.5 29.3 34.8 30.9 37.0 31.8 39.2 33.6 42.2 40.1 44.9 44.9 47.1 47.1 20 29.5 26.5 31.9 28.7 34.1 30.3 36.3 31.2 38.5 32.9 41.3 39.3 44.0 44.0 46.2 46.2 25 28.4 25.5 30.7 27.6 32.8 29.2 34.9 30.0 37.1 31.7 39.8 37.4 42.3 42.3 44.5 44.5 15 40.2 38.4 42.5 38.0 44.8 38.5 47.1 47.1 49.4 49.4 51.7 51.7 54.0 54.0 56.3 56.3 20 39.6 37.9 41.9 37.5 44.2 44.2 46.5 46.5 48.8 48.8 51.1 51.1 53.4 53.4 55.7 55.7 25 38.4 37.0 40.6 36.5 42.9 40.6 45.2 45.2 47.5 47.5 49.8 49.8 52.1 52.1 54.4 54.4 15 41.5 39.6 43.8 39.2 46.2 39.7 48.6 48.6 50.9 50.9 53.3 53.3 55.7 55.7 58.0 58.0 20 40.8 39.1 43.2 38.7 45.6 45.6 47.9 47.9 50.3 50.3 52.7 52.7 55.0 55.0 57.4 57.4 25 39.5 38.1 41.9 37.7 44.3 41.9 46.6 46.6 49.0 49.0 51.4 51.4 53.7 53.7 56.1 56.1 15 46.7 44.7 49.4 44.2 52.1 44.8 54.7 47.5 57.4 57.4 60.1 60.1 62.7 62.7 65.4 65.4 20 46.0 44.1 48.7 43.6 51.4 44.2 54.0 54.0 56.7 56.7 59.4 59.4 62.0 62.0 64.7 64.7 25 44.6 43.0 47.2 42.4 49.9 49.9 52.6 52.6 55.2 55.2 57.9 57.9 60.6 60.6 63.2 63.2 15 47.3 45.2 50.0 44.7 52.7 45.3 55.4 48.0 58.1 58.1 60.8 60.8 63.5 63.5 66.2 66.2 20 46.6 44.7 49.3 44.1 52.0 44.8 54.7 54.7 57.4 57.4 60.1 60.1 62.8 62.8 65.5 65.5 25 45.1 43.5 47.8 43.0 50.5 50.5 53.2 53.2 55.9 55.9 58.6 58.6 61.3 61.3 64.0 64.0 15 54.5 47.7 59.0 50.8 63.1 52.0 67.2 53.1 71.2 53.8 76.5 59.4 81.4 63.5 85.5 85.5 20 53.5 46.8 57.9 49.8 61.9 51.0 65.8 52.0 69.8 52.7 75.0 54.8 79.8 62.2 83.8 83.8 25 51.5 45.1 55.7 47.9 59.6 49.1 63.4 50.1 67.2 50.8 72.2 52.7 76.9 59.9 80.7 80.7 15 61.6 53.9 66.6 57.3 71.2 58.8 75.8 59.9 80.4 60.7 86.4 67.1 91.9 71.7 96.5 96.5 20 60.4 52.8 65.3 56.2 69.8 57.6 74.3 58.7 78.8 59.5 84.7 61.8 90.1 70.3 94.6 94.6 25 58.1 50.8 62.9 54.1 67.2 55.5 71.6 56.6 75.9 57.3 81.6 59.5 86.8 67.7 91.1 91.1 * EC Plug fan version Page 9 of 22

Performance Data AIR HANDLING Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow or low resistance application, beware of exceeding indoor fan motor s full load amp limit.. Refer page 11 for Filter Pressure Drop. ISD 380KB-P (c/w Plug fans) ISD 380KBY AVAILABLE EXTERNAL PRESSURE (Pa) 500 400 300 200 100 l/s - Pa 8.2V DC 8.2V DC 9.2V DC 9.2V DC 10.0V DC ---- l/s - W 10.0V DC 0 2000 2100 2200 2300 2400 2500 AIR FLOW (l/s) 2.5 m/s Face Velocity 3.0 2.5 2.0 1.5 1.0 INPUT (kw) AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 100 50 l/s - Pa 1100 RPM (7.3V) 1000 RPM (6.7V) 800 RPM (5.3V) 0 1400 1600 1800 2000 2200 2400 AIR FLOW (l/s) Face Velocity 2.0 m/s 2.5 m/s ISD 465KB AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 100 50 l/s - Pa 600 RPM 750 RPM 700 RPM 850 RPM 800 RPM 3 kw MOTOR LIMIT ---- l/s - W 0 1800 2000 2200 2400 2600 2800 3000 AIR FLOW (l/s) 2.3 m/s Face Velocity ISD 570KB-P (c/w Plug fans) AVAILABLE EXTERNAL PRESSURE (Pa) 500 400 300 200 100 l/s - Pa 8V 7V 9V 1.2kW 1.1kW 10V 3.7kW 2.8kW 2.4kW 3.3kW 0 1500 2000 2500 3000 3500 4000 AIR FLOW (l/s) 2.5 m/s Face Velocity ISD 570KB AVAILABLE EXTERNAL PRESSURE (Pa) 500 400 300 l/s - Pa 2.3kW 1.7kW 200 1.3kW 3.5kW 900 RPM 800 RPM 700 RPM 600 RPM ---- l/s - W 5.5 kw MOTOR LIMIT 4.5kW 5.5kW 100 3.5kW 2.2kW 0 1500 2000 2500 3000 3500 4000 AIR FLOW (l/s) 2.5 m/s Face Velocity Model : ISD 465KB ISD 570KB Std Motor Size kw 3 5.5 Max. D.O.L. Motor kw 3 7.5 Max. Fan Speed RPM 800 1000 Std Pulley Range RPM 600 800 600 800 Factory Setting RPM 700 700 Page 10 of 22

Performance Data AIR HANDLING Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow or low resistance application, beware of exceeding indoor fan motor s full load amp limit.. ISD 670KB-P (c/w Plug fans) ISD 670KB l/s - Pa l/s - Pa ---- l/s - W 10V 3.7kW 500 9V 2.8kW 500 AVAILABLE EXTERNAL PRESSURE (Pa) 400 300 200 100 8V 7V 1.2kW 1.1kW 2.4kW 3.3kW 0 1500 2000 2500 3000 3500 4000 AIR FLOW (l/s) 2.5 m/s Face Velocity AVAILABLE EXTERNAL PRESSURE (Pa) 5.5 kw MOTOR LIMIT 400 2.4kW 900 RPM 4.4kW 1.8kW 300 5.6kW 1.3kW 200 4.5kW 800 RPM 100 3.6kW 2.2kW 600 RPM 700 RPM 0 2000 2500 3000 3500 4000 4500 AIR FLOW (l/s) Rating 2.5 m/s Face Velocity ISD 840KB ISD 950KB Optional Filters - Pressure Drop l/s - Pa ---- l/s - W l/s - Pa 1000 RPM ---- l/s - W Based on Koch Multi-Pleat HC filter. Max. final pressure drop 250 Pa. 100 500 500 AVAILABLE EXTERNAL PRESSURE (Pa) 400 300 200 100 700 RPM 600 RPM 5.5 kw MOTOR LIMIT 800 RPM 0 3000 3500 4000 4500 5000 5500 AIR FLOW (l/s) 2.5 m/s Face Velocity AVAILABLE EXTERNAL PRESSURE (Pa) 400 300 200 100 800 RPM 700 RPM 900 RPM 7.5 kw MOTOR LIMIT 0 3000 3500 4000 4500 5000 5500 AIR FLOW (l/s) 2.5 m/s Face Velocity PRESSURE DROP (Pa) 75 50 25 INITIAL (Clean Filter) 0 1.5 2.0 2.5 3.0 FILTER FACE VELOCITY (m/s) Model : ISD 670KB ISD 840KB ISD 950KB Std Motor Size kw 5.5 5.5 7.5 Max. D.O.L. Motor kw 7.5 7.5 7.5 Max. Fan Speed RPM 1000 950 1000 Std Pulley Range RPM 600 800 615 755 685 840 Factory Setting RPM 700 685 765 Page 11 of 22

Performance Data SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt, at nominal airflow. INDOOR UNIT - SUPPLY AIR OUTLET Models FAN SPEED SWL db(a) OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K SOUND POWER LEVELS (SWL) db 750 RPM (5V) 73 72 68 70 67 66 63 ISD 380KBY 950 RPM (6.3V) 80 78 73 76 75 74 70 1150 RPM (7.6V) 85 82 78 80 80 79 74 LOW (7V) 71 72 70 68 67 60 54 ISD 380KB-P MED (8V) 74 74 73 71 71 65 59 HIGH (9V) 78 75 79 74 74 69 63 ISD 465KB 810 RPM 81 79 76 79 76 74 72 ISD 570KB 600 RPM 81 80 81 78 76 76 73 800 RPM 86 87 85 82 80 80 77 LOW (7V) 63 69 62 61 60 51 50 ISD 570KB-P MED (8V) 72 81 72 71 66 62 57 HIGH (9V) 80 86 79 79 74 69 66 ISD 670KB 600 RPM 81 80 81 78 76 76 73 800 RPM 86 87 85 82 80 80 77 LOW (5V) 63 69 62 61 60 51 50 ISD 670KB-P MED (7V) 72 81 72 71 66 62 57 HIGH (9V) 80 86 79 79 74 69 66 ISD 840KB 600 RPM 81 80 81 78 76 76 73 800 RPM 86 87 85 82 80 80 77 700 RPM 80 81 79 75 73 74 72 ISD 950KB 900 RPM 86 86 84 82 81 80 77 1000 RPM 88 89 87 84 82 82 79 SOUND PRESSURE LEVELS (SPL) WITHIN A ROOM Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Room type ROOM ABSORPTION EFFECT Soft 4 8 11 11 11 11 Medium 3 7 8 9 9 9 Hard 0 1 3 4 4 5 Page 12 of 22

Performance Data OUTDOOR UNIT OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS db OSA 380 OSA 465 OSA 570 OSA 670 LOW 79 84 82 77 73 64 58 HIGH 80 84 83 78 75 67 61 LOW 79 84 82 77 73 64 58 HIGH 80 84 83 78 75 67 61 LOW 79 84 82 77 73 64 58 HIGH 80 84 83 78 75 67 61 LOW 79 84 82 77 73 64 58 HIGH 80 84 83 78 75 67 61 OSA 840 HIGH 82 85 80 79 78 73 66 OSA 950 HIGH 82 85 80 79 78 73 66 Sound Pressure Level (SPL) in decibels re 20 µpa. Models FAN SPEED SPL @ 3 m db(a) SOUND PRESSURE LEVELS db OSA 380 OSA 465 OSA 570 OSA 670 LOW 63 68 66 61 57 48 42 HIGH 64 68 67 62 59 51 45 LOW 63 68 66 61 57 48 42 HIGH 64 68 67 62 59 51 45 LOW 63 68 66 61 57 48 42 HIGH 64 68 67 62 59 51 45 LOW 63 68 66 61 57 48 42 HIGH 64 68 67 62 59 51 45 OSA 840 HIGH 66 69 64 63 62 57 50 OSA 950 HIGH 66 69 64 63 62 57 50 Page 13 of 22

Dimensions (mm) ISD 380KBY INDOOR UNIT W 275 2183 MOUNTING STRAP & OPTIONAL SPRING 1706 X REFRIGERANT CONNECTIONS Not to Scale PROJECTION 600 MIN. CLEARANCE 806 OPTIONAL SPRING MTG CTRS 600 MIN. CLEARANCE CORNER LOADS (kg) W X Y Z 44 48 58 53 Z EC MOTOR CONTROL BOX 70 2100 Y HOLES 17 ID EC MOTOR CONTROL BOX EC MOTOR CONTROL BOX 60 150 705 OVERALL 120 290 585 60 2315 OVERALL ISD 380KB-P INDOOR UNIT (C/W PLUG FANS) 70 ELECTRICAL BOX DRAIN 28 OD 830 OA REFRIG. CONN S 65 OPTIONAL FILTER BOX W 275 2183 MOUNTING STRAP & OPTIONAL SPRING 1706 X REFRIGERANT CONNECTIONS Not to Scale PROJECTION 600 MIN. CLEARANCE VERTICAL DISCHARGE VERSION 806 OPTIONAL SPRING MTG CTRS 600 MIN. CLEARANCE CORNER LOADS (kg) W X Y Z 42 49 42 36 70 Z 70 2100 Y HOLES 17 ID 290 VERTICAL DISCHARGE VERSION 150 60 60 120 705 OVERALL 290 585 60 65 2315 OVERALL 70 ELECTRICAL BOX DRAIN 28 OD 830 OA REFRIG. CONN S OPTIONAL FILTER BOX Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 14 of 22

Dimensions (mm) ISD 465KB INDOOR UNIT FILTER EITHER SIDE 45 W 1405 X ELECTRICAL BOX Not to Scale PROJECTION 412 REFRIGERANT CONNECTIONS 1000 MIN. CLEARANCE CORNER LOADS (kg) W X Y Z 57 74 82 64 245 Z Y 505 477 VERTICAL DISCHARGE MODEL 60 ELECTRICAL REFRIGERANT CONNECTIONS 150 1210 OA 410 1110 500 255 1055 1565 OA 80 1200 OA DRAIN 28 OD 75 Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 15 of 22

Dimensions (mm) ISD 570/670 KB INDOOR UNIT FILTER EITHER SIDE 70 W 1435 X Not to Scale PROJECTION REFRIGERANT CONNECTIONS 465 1000 MIN. CLEARANCE CORNER LOADS (kg) Model W X Y Z ISD 570 75 92 119 47 55 Z 445 565 Y VERTICAL DISCHARGE MODEL ELECTRICAL BOX 60 ELECTRICAL 150 ISD 670 81 100 121 48 1150 OA 465 1020 485 80 DRAIN 28 OD 265 1100 1650 OA 1345 OA ISD 570/670 KB-P INDOOR UNIT (C/W PLUG FANS) 90 FILTER EITHER SIDE 70 1435 Not to Scale PROJECTION W X REFRIGERANT CONNECTIONS 75 575 Z 370 900 Y ELECTRICAL BOX 1000 MIN. CLEARANCE CORNER LOADS (kg) Model W X Y Z ISD 570 81 81 52 52 ISD 670 87 87 54 54 235 1100 VERTICAL DISCHARGE MODEL 60 ELECTRICAL 150 1150 OA 700 1020 265 1100 1650 OA 80 250 1345 OA DRAIN 28 OD 90 Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 16 of 22

Dimensions (mm) ISD 840/950 KB INDOOR UNIT FILTER EITHER SIDE 75 W 2005 X ELECTRICAL BOX Not to Scale PROJECTION 470 305 REFRIGERANT CONNECTIONS 1000 MIN. CLEARANCE DIM. CORNER LOADS (kg) Model A B W X Y Z ISD 840KB 1070 955 70 116 116 70 Z Y ISD 950KB 1280 1165 66 137 125 55 830 565 VERTICAL DISCHARGE MODEL 60 ELECTRICAL 150 A REFRIG. CONN S 470 B 535 75 430 1360 2220 OA 105 1320 OA DRAIN 28 OD Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 17 of 22

Dimensions (mm) OSA 380RKTB(G) OUTDOOR UNIT W OUTDOOR AIR FLOW X Not to Scale PROJECTION 1480 1000 MIN. CLEARANCE CORNER LOADS (kg) W X Y Z Z OUTDOOR AIR FLOW Y 154 77 79 144 Recommended Pipe Sizes Suction: 22 mm OD (x2) Liquid: 13 mm OD (x2) 1420 O/A REFRIG. CONN S 1502 (1504) 55 1227 (1217) 1755 (1711) O/A OSA 465RKTB OUTDOOR UNIT W OUTDOOR AIR FLOW X Not to Scale PROJECTION 1480 1000 MIN. CLEARANCE DOORS CORNER LOADS (kg) W X Y Z 146 77 77 145 Z OUTDOOR AIR FLOW Y Recommended Pipe Sizes Suction: 22 mm OD (x2) Liquid: 13 mm OD (x2) DOOR ( ) Bracketed figures are for Digital version 1270 O/A REFRIG. CONN S 1504 55 1276 1790 O/A Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 18 of 22

Dimensions (mm) OSA 570/670 RKTB OUTDOOR UNIT Not to Scale W OUTDOOR AIR FLOW X PROJECTION 1480 1000 MIN. CLEARANCE DIM. CORNER LOADS (kg) Model A B W X Y Z OSA 570 1345 1263 174 81 81 175 Z OUTDOOR AIR FLOW Y OSA 670 1390 1231 182 88 88 183 Recommended Pipe Sizes Suction: 28 mm or 35 mm OD (x2) Liquid: 13 mm OD (x2) A OVERALL 1506 OSA 840/950 RKTB OUTDOOR UNIT 55 B 1755 O/A W OUTDOOR AIR FLOW X Not to Scale PROJECTION 1680 1000 MIN. CLEARANCE CORNER LOADS (kg) Model W X Y Z OSA 840 193 92 92 194 OSA 950 185 109 109 186 Z OUTDOOR AIR FLOW Y Recommended Pipe Sizes Suction: 35 mm OD (x2) Liquid: 16 mm OD (x2) 1210 O/A REFRIG. CONN S 1502 55 262 1771 2300 O/A Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 19 of 22

Specifications System Indoor Unit ISD 380KBY ISD 380KB-P ISD 465KB Outdoor Unit OSA 380RKTB OSA 380RKTB OSA 465RKTVB Nominal Cooling Capacity * 1 kw 37.6 37.1 44.6 Net Cooling Capacity kw 36.4 35.9 42.6 Heating Capacity * 2 38.8 (35.9) 38.5 (35.7) 44.0 EER / AEER (Cooling) 3.26 / 3.25 3.20 / 3.19 2.98 / 2.95 COP / ACOP (Heating) 3.46 / 3.44 3.43 / 3.41 3.53 / 3.51 Controller UC6 Indoor air fan type forward curved backward curved forward curved Indoor air fan motor EC EC plug AC induction Air Flow * 3 l/s 2100 2550 Power Source * 4 3 phase 400 V a.c. 50 Hz Indoor Fan Full Load Amps A/ph. 6 (x2) 2.5 (x2) 6.2 Running Amps (Total System) A/ph. 22 / 17 / 16 22 / 17 / 17 31 / 26 / 25 Max. Running Amps (Total Sys.) A/ph. 21 / 25 / 25 22 / 27 / 22 43 / 37 / 37 Refrigerant R410A Maximum Vertical Separation m 20 20 Maximum Standard Line Length m 60 30 or 60* 5 Pipe Sizes (Suction/Liquid) mm OD 22 / 13 22 / 13 Operating Range (outdoor ambient) Cooling -10 C to 52 C Heating -15 C to 25 C Finish Indoor Unit Outdoor Unit zinc galvanised steel grey polyester powder coat Weight Net Weight (indoor/outdoor) kg 203 / 458 169 / 458 277 / 445 Shipping Weight (ind./out.) (approx.) kg 226 / 474 195 / 474 300 / 490 Notes: * 1 Nominal Cooling Capacity at AS/NZS 3823 conditions: - Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; - Outdoor Entering Air Temperature 35 C D.B. Net Cooling Capacity at AS/NZS 3823 includes an allowance for indoor fan motor heat loss. ( ) Bracketed figure is performance when matched to digital outdoor unit, ie OSA 380RKTBG. * 2 Heating Capacity (reverse cycle units only) at AS/NZS 3823 conditions: - Indoor Entering Air Temperature 21 C D.B.; - Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Power source includes voltage limits. * 5 Extra suction accumation required. Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 20 of 22

Specifications System Indoor Unit ISD 570KB ISD 570KB-P ISD 670KB ISD 670KB-P ISD 840KB ISD 950KB Outdoor Unit OSA 570RKTB OSA 570RKTB OSA 670RKTB OSA 670RKTB OSA 840RKTB OSA 950RKTB Nominal Cooling Capacity * 1 kw 56.1 56.6 65.9 65.5 84.7 94.9 Net Cooling Capacity kw 54.0 55.0 62.8 63.0 79.4 90.0 Heating Capacity * 2 55.9 53.4 62.8 62.0 79.8 90.1 EER / AEER (Cooling) 3.10 / 3.09 3.27 / 3.26 2.97 / 2.96 3.07 / 3.06 2.70 / 2.68 2.70 / 2.68 COP / ACOP (Heating) 3.37 / 3.35 3.48 / 3.46 3.47 / 3.45 3.43 / 3.41 3.21 / 3.19 3.30 / 2.28 Controller UC6 OUC Indoor air fan type forward curved backward curved forward curved backward curved forward curved forward curved Indoor air fan motor AC induction EC plug AC induction EC plug AC induction AC induction Air Flow * 3 l/s 3100 3600 4500 5000 Power Source * 4 3 phase 400 V a.c. 50 Hz Indoor Fan Full Load Amps A/ph. 11.0 5.7 11.0 5.7 11.0 14.3 Running Amps (Total System) A/ph. 38 / 33 / 32 34 / 28 / 27 38 / 43 / 38 34 / 39 / 33 59/ 50/ 50 58/ 59/ 59 Max. Running Amps (Total Sys.) A/ph. 47 / 42 / 41 44 / 38 / 37 50 / 54 / 48 45 / 50 / 44 Refrigerant R410A Maximum Vertical Separation m 20 20 20 20 Maximum Standard Line Length m 60 / 90 60 / 90 50 / 90 50 / 90 Pipe Sizes (Suction/Liquid) mm OD (28 or 35)* 5 / 13 (28 or 35)* 5 / 13 35 / 16 35 / 16 Operating Range (outdoor ambient) Cooling -10 C to 52 C -10 C to 46 C Heating -15 C to 25 C -15 C to 25 C Finish Indoor Unit Outdoor Unit zinc galvanised steel grey polyester powder coat Weight Net Weight (indoor/outdoor) kg 333 / 511 333 / 511 350 / 541 282 / 541 372 / 546 383 / 560 Shipping Weight (ind/out) (approx.) kg 380 / 565 380 / 565 397 / 580 329 / 580 410 / 638 423 / 651 Notes: * 1 Nominal Cooling Capacity at AS/NZS 3823 conditions: - Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; - Outdoor Entering Air Temperature 35 C D.B. Net Cooling Capacity at AS/NZS 3823 includes an allowance for indoor fan motor heat loss. ( ) Bracketed figure is performance when matched to digital outdoor unit, ie OSA 380RKTBG. * 2 Heating Capacity (reverse cycle units only) at AS/NZS 3823 conditions: - Indoor Entering Air Temperature 21 C D.B.; - Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Power source includes voltage limits. * 5 Longer line length require greater size suction line. Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 21 of 22

www.temperzone.biz AUCKLAND Head Office 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Phone (09) 279 5250 Fax (09) 275 5637 SYDNEY Head Office 14 Carnegie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au Phone (02) 8822-5700 Fax (02) 8822-5711 NEWCASTLE Phone (02) 4962-1155 Fax (02) 4961-5101 TOWNSVILLE Phone (07) 4774-3506 Fax (07) 4774-3001 WELLINGTON Phone (04) 569 3262 Fax (04) 566 6249 ADELAIDE Phone (08) 8115-2111 Fax (08) 8115-2118 LAUNCESTON Phone (03) 6331-4209 Fax (03) 6333-0224 CHRISTCHURCH Phone (03) 379 3216 Fax (03) 379 5956 MELBOURNE Phone (03) 8769-7600 Fax (03) 8769-7601 JAKARTA Phone +62 (21) 2963 4983 Fax +62 (21) 2963 4984 BRISBANE Phone (07) 3308-8333 Fax (07) 3308-8330 SINGAPORE Phone +65 6733 4292 Fax +65 6235 7180 PERTH Phone (08) 6399-5900 Fax (08) 6399-5932 SHANGHAI Phone +86 (21) 5648 2078 Available from temperzone limited 2016 Pamphlet No. 4075c 08/16