General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

GA 24 Heavy-duty variable area flowmeter

YOKOGAWA. General Specifications. Model RAKC Short-tube Rotameter. GS 1R1B3-E-H 4rd Edition

General Specifications

Variable V Area Flowmeter Rotameter The Original

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

General Specifications

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

YOKOGAWA. General Specifications. Model RAMC-Series Metal Short-stroke Rotameter

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

General Specifications

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Differential Pressure and Flow meters Accessories for the Media Series

Personal ph, ph/orp, Conductivity Meters

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Manifolds for DPHarp EJA and EJX Pressure and Differential Pressure Transmitters. Pressure psi (bar) (860) (552) (413) 4.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

SATRON VT Pressure Transmitter

Metal tube variable area flowmeter for gases, liquids and steam

Differential pressure transmitter PASCAL Ci4 Delta P

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Ar-Mite TM Low Flow Armored Flowmeter

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

Flap-Type Flow Meter Prall

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Variable Area Flowmeters Armored Purgemeter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Plastic tube variable area flowmeter for liquids and gases

Process to Instrument Valves: C13SF Monoflanges For DPharp EJX & EJA-E Pressure Transmitters

Level Measurement Point level measurement - RF Capacitance switches

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Design and application

2/2- and 3/2-way solenoid valve for aggressive fluids

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

K - Flow Meter with Float

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Material pressure (bar) (Cv (US) kv x 1,2 Seat

General Specifications

Direct-acting 2/2- or 3/2-way pivoted armature valve

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Flow switches Series AD/VH

Type MR 783 Magnetic level switch

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Differential pressure gauge with diaphragm

IECEx Certificate of Conformity

Absolute pressure gauge with diaphragm

Variable area flowmeter H 250

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Compact pressure switch Model PCS

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Plug and Socket Devices SolConeX 16 A Series 8570

Sensor boxes SRBE Key features and product range overview

Direct-acting 3/2 way plunger valve

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Fluxi 2000/TZ Turbine Gas Meter

SATRON VDt Differential Pressure Transmitter

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Direct-acting 2/2-way plunger valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Level Measurement Point level measurement - RF Capacitance switches

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

Transcription:

General Specifications Model RAG Glass ROTAMETER GS 01R01B10-00E-E The Rotameter RAG is designed for continuous flow measurement of liquids and gases. The fluid passes through the metering tube from bottom to top and consequently needs to be installed vertically with flow direction upwards. The conical glass metering tube includes a free rotating float which provides self stabilization. The actual flow is indicated by the top of the float and can be directly read from the scale on the metering tube. Features: All stainless steel design Turnable splinter shield Designed for aggressive applications Easy to install and maintain Wide measuring range selection for gases and liquids ow pressure loss Easy to read scale Optional limit switches with connection box FMEDA report available for SI applications Applications: Visual fluid monitoring Industrial gas measurement Controlling of water circuits Contents Features page 1 Applications page 1 Standard Specifications page Option Specifications page Metrological Regulations in CIS (Gost) page 3 Model Specifications page 4 Flow Table for Water / iquids page 5 Flow Table for Air / Gases page 6 Options page 7 Procedure to select the model code page 8 Dimensions page 8 Rota Yokogawa GmbH & Co. KG Rheinstr. 8 D-79664 Wehr Germany GS 01R01B10-00E-E Copyright 011(RYG) 5th edition, July 017(RYG)

STADARD SPECIFICATIOS RoHS Directive 011/65/EU RoHS conform according to E 50581 Fluids to be measured : iquids and gas Measurable flow rates : Water (0 C) : 0.00 l/h 10 m3/h Air (0 C; 1 bar abs.) : 0.1 l/h 160 m3/h Turndown: P metering tube : 10:1 metering tube : 0:1 Metering tubes Process temperature : -5 C 100 C Process pressure : : 6; 7; P0; P1; P; P4 (length 300 mm) Metering tube 6;7 P0;P1 P P4 Pmax (bar) 16 10 8 6 Installation length: Process connection Thread Clamp Flange ength [mm] 375 375 45 Weight : Depending on design (see page 7) Accuracy: Tube Measuring accuracy acc. Directive VDI/VDE 3513 sheet (q G = 50 %) 613-63.5 % 64-747 1.6 % P051 - P471 1.6 % Materials: Threads G, PT : AISI 316 (1.4404) Flange E / ASME : AISI 316 (1.4404) Clamp ISO 85 : AISI 316 (1.4404) Housing : AISI 304 (1.4301) ut : AISI 316 (1.4401) (or galvanized steel) Stoppers (6, 7 tube) : PFA Stoppers (P0 - P4 tube) : PVDF, AISI 316 (1.4404) Measuring cone : Borosilicate glass Float (6, 7 tube ) : Titanium, PVDF Float (P0 - P4 tube) : PTFE, PVDF (FDA conform), AISI 316Ti (1.4571) Gaskets : BR, FKM,EPDM (FDA conform) Pressure Equipment Directive (PED) Directive 014/68/EU: Models : RAG04, RAG05, RAG06 Tubes: Modul : A Fluid Group : 1 (liquid, gases) Produced acc. to category : I Following ISO 13849-1: Safety Metrics available for: RAG with Read-switch (/GM1 /GM5) RAG with Ring Initiator (/GR /GR5) Details see FMEDA report. OPTIO SPECIFICATIOS imit switch (option /GM1 /GM5): ( for P- tubes with PVDF- or SS- float with magnet only) Type : reed contact with bistable switching Max. switching voltage : 30 V Max. switching current : A Max. switching capacity : 40 W/VA Temperature range : -10 C +70 C Protection : IP65 Internal capacity : 0 nf Internal inductivity : 0 mh Electrical connection : IYY x 0.34 mm²; length 1 m Housing : Polystyrene Weight : 35 g Explosion proof : Intrinsic safe acc. E 60079-11 chapter 5.7, IEC 60079-11 chapter 5.7 and ASI/ISA 60079-11 chapter 5.7 as "Simple Apparatus". Group : IIC Category : G Temperature class: T6 Entity parameter : Ui = 15 V ; Ii = 50 ma ; Pi = 187 mw i 0 mh ; Ci 0 nf imit switch (option /GR /GR8): (for - tubes with PVDF float only) Type : Bistable inductive ring sensor Power supply : 4.5 V 15 V DC Consumption : acc. DI E 60947-5-6 (AMUR) Float below ring sensor : < 1 ma Float above ring sensor : >. ma Temperature range : -5 C +65 C non-ex- type Protection : IP 67 Electrical connection : 1 x 0.14 mm², with shield 0.4 mm², m long EMC Compliance: EMC compliance according E 60947-5- table 8 (for use in industrial locations). Based on EMC compliance the limit switch is marked with CE, EAC and RCM. In general the RI0 complies with the above given criteria. However, in certain situations the switch may react from off to on. In such cases the customer has to assure by himself that this does not happen. ormally the behavior can be improved by more distance to the EMC-source or by using a different cable position. FDA-Conformity: RAG with P- ube, PVDF- or SS- float and EPDM- gaskets (option /ME). Stoppers and floats made of PVDF: 1 CFR 177 510(a) O-rings made of EPDM: 1 CFR 177 600-1 Following IEC 61508: RAG with Read-switch (/GM1 /GM5) Suitable for application in safety functions up to and including SI1. RAG with Ring Initiator (/GR /GR5) Suitable for application in safety functions up to and including SI1. Details see FMEDA report. GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa

3 Explosion proof type (option /KS1, /ES1, /S1): Temperature range : -5 C +60 C Type : RI0-10K/G or RI0-17K/G Year of production: in serial number Protection : Ex ia IIC T6 Gb Certificate o. : PTB 03ATEX 111 (/KS1) IECEx PTB13.003 (ES1) EPSI GYJ14.1356 (/S1) Taiwan Safety label: Registration Document: M041007043A3 Option /ES1 must be selected. For export to Taiwan please contact your Yokogawa representative regarding Taiwan Safety abel Safety relevant data (see also certificate for data): Ui = 1 V, Ii = ma, Pi = 66 mw, i = 0 mh, Ci = 00 nf CE-marking: II G Power supply for limit switch (option /W ) Type : acc. DI E 60947-5-6 (AMUR) KFA5-SR-Ex*-W (115 V AC), * = 1 or KFA6-SR-Ex*-W (30 V AC), * = 1 or KFD-SR-Ex*-W (4 V DC), * = 1 or KHA6-SH-Ex1 (115/30 V AC), Fail Safe, 1 channel KFD-SH-Ex1 (4 V DC), Fail Safe, 1 channel Power supply: 30 V AC ± 10 %, 45-65 Hz 115 V AC ± 10 %, 45-65 Hz 4 V DC ± 5% Relay output: 1 or potential-free changeover contact(s) Switching capacity: max. 50 V AC, max. A Explosion proof: Intrinsic safe [Ex ia] IIC PTB 00 ATEX 081 (/W1A, /W1B, /WA, /WB) PTB 00 ATEX 080 (/W4A, /W4B) PTB 00 ATEX 04 (/W4E, /W4F) PTB 00 ATEX 043 (/WE, /WF) IECEx PTB11.0031 (/W1A, /W1B, /WA, /WB) IECEx PTB11.0034 (/W4A, /W4B) ote: For safety applications with options /GM fail safe power supply option /WE, /WF, /W4E or /W4F must be selected. METROOGICA REGUATIO I CIS (GOST) RAG has Pattern Approval Certificate of Measuring Instruments and is registered as a measuring instrument in Russia. For export to CIS countries please contact your Yokogawa representative. All Rights Reserved. Copyright 011, Rota Yokogawa GS 01R01B10-00E-E 5th edition, June 7 017-00

4 MODE SPECIFICATIOS Model Suffix code Description Restrictions RAG01 RAG3 RAG0 RAG04 RAG05 RAG06 Process connection -D4 -A1 -G0 -T0 -S4 Material of process connections SS Metering tube 1) - -P Diameter of metering tube 1) 6 7 0 1 4 Cone 1) 13 14 17 1 3 4 7 31 3 33 34 37 41 4 43 44 47 51 5 53 54 57 61 6 63 64 67 71 Float material 1) Diameter of float 1) Medium / Float factor 1) Float insertion 1) 1) Combinations see tables on page 5 and 6 -SS -PF -PD -TT A B C D 0 1 4 G 3 6 7 M Size D 15 (½ inch) Size ¾ inch Size D 5 (1 inch) Size D 40 (1½ inch) Size D 50 ( inch) Size ½ inch E flange P 40, process connection dimension + facing acc. E 109- Form B1 ASME flange class 150, process connection dimension + facing acc. ASME B 16.5 Inner thread G Inner thread PT Clamp ISO 85 Stainless steel -tube (300 mm) P-tube (300 mm) 10 mm 17 mm 0 mm 34 mm 48 mm 81 mm 1.4571 / AISI 316 Ti PTFE PVDF Titanium 1.59 mm 3.18 mm 6.35 mm 9.53 mm 1. (P0-float) mm 1.6 (P1-float) mm 31. (P-float) mm 54.1 (P4-float) mm For liquid For gas For water (factor 0.63) For water (factor 1) For air (factor 16) For air (factor -4) Without magnet With magnet for D4, A1, G0, T0, S4 with 6, 7, P0, P1 for G0, T0 with 6, 7, P0, P1 for D4, A1, G0, T0, S4 with 6, 7, P0, P1, P for D4, A1, G0, T0 with P, P4 for D4, A1, with P, P4; for G0, T0 with P4 for G0, T0 with P4 GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa

5 FOW TABE WITH METERIG TUBE-FOAT-COMBIATIO FOR WATER / IQUIDS Flow table Suffix code metering tube - float- combination Water / liquids 0 C Metering tube Float Max. Flow in l/h Pressure loss in mbar ength Diameter Cone 0.05 1 6 13 0.04 1 6 14 0.063 6 17 0.1 6 1 0.16 3 6 0.5 4 6 3 0.4 1 6 4 0.63 1 6 7 1 6 31 1.6 3 6 3.5 4 6 33 4 7 34 6.3 7 37 10 3 7 41 16 4 7 4 5 5 7 43 40 5 7 44 63 10 7 47 63 10 P 0 51 100 16 P 0 5 100 16 P 0 51 160 4 P 0 5 160 15 P 1 53 50 16 P 1 54 400 18 P 1 57 630 6 P 1 61 50 15 P 1 53 400 16 P 1 54 630 18 P 1 57 1000 6 P 1 61 1000 11 P 6 1600 13 P 63 1600 6 P 6 500 30 P 63 500 16 P 4 64 4000 18 P 4 67 6300 1 P 4 71 4000 40 P 4 64 6300 44 P 4 67 10000 53 P 4 71 Description ength metering tube 300 mm... 300 mm... P Diam. metering tube 10 mm 81 mm... x Cone metering tube See flow table... xx -x x xx -xx x x x Material Diameter Flow mark TT A 1) TT;PD PD B C D 0 SS 3 PD 1 SS 3 PD SS 3 PD 4 SS 3 Float material 1.4571... Titanium... PTFE... PVDF... SS TT PF PD Float diameter 1.6 mm to 54 mm... x Flow mark For liquid... For water... For water... Float insertion Without magnet... With magnet... 1) Max. viscosity mpas*s ) For option limit switch /GM1 /GM5 Insertion M M ) ; M M ) ; M M ) ; M 3 M ) ; M ) All Rights Reserved. Copyright 011, Rota Yokogawa GS 01R01B10-00E-E 5th edition, June 7 017-00

6 FOW TABE WITH METERIG TUBE-FOAT-COMBIATIO FOR AIR / GASES Flow table Suffix code metering tube - float- combination Air/Gases 0 C, 1 bar abs Metering tube Float Max. Flow in l/h Pressure loss in mbar -x x xx -xx x x x ength Diameter Cone 1.9 1 6 13 3 1 6 14 4.4 6 17 6.5 6 1 10 3 6 14 4 6 3 3 6 4 33 6 7 50 6 31 70 3 6 3 100 4 6 33 180 3 7 34 50 3 7 37 400 3 7 41 630 4 7 4 1000 5 7 43 1600 5 7 44 400 10 7 47 1600 4 P 0 51 500 6 P 0 5 400 8 P 0 51 3800 11 P 0 5 6000 6 P 1 53 9300 7 P 1 54 14500 8 P 1 57 3000 10 P 1 61 400 5 P 1 53 6300 5 P 1 54 10000 6 P 1 57 16000 8 P 1 61 35000 11 P 6 55000 13 P 63 5000 8 P 6 40000 10 P 63 88000 9 P 4 64 140000 3 P 4 67 0000 34 P 4 71 63000 13 P 4 64 100000 14 P 4 67 160000 17 P 4 71 Description ength metering tube 300 mm... 300 mm... Diam. metering tube 10 mm 81 mm... x P Material Diameter Flow mark TT A G PD;TT PF B C D 0 G G G 6 Insertion PD 7 M 1) PD 1 7 M 1) PF 1 6 PD 7 M 1) PF 6 PD 4 7 M 1) PF 4 6 Cone metering tube See flow table... xx Float material Titanium... PTFE... PVDF... Float diameter 1.6 mm to 54 mm... x Flow mark For gas... For air... For air... Float insertion Without magnet... With magnet... TT PF PD G 6 7 M 1) 1) For option limit switch /GM1 /GM5 GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa

OPTIOS Options Description Restriction Marking /B1 /B4 /BG /B10 /B11 /BD Tag plate (SS) eutral version Customer specific notes on name plate Percentage scale Measuring tube without yellow background Dual scale Plate 1 x 40 mm; max. 45 digits ot with /KS1 Max. 45 digits Only for tube P imit switches Ex-proof type Installation lengths (s. also table on page 7) Valves (inner thread, double fitting is attached, not for FDA) /GM1 /GM /GM3 /GM4 /GM5 /GR /GR3 /GR4 /GR6 /GR7 /GR8 /GD1 /GD /KS1 /ES1 /S1 /1 /13 /14 /15 /16 /V1 /V /V3 /V4 /V5 /V6 Test and certificates /H1 /P /P3 /P6 /PP /PT /PM /PM4 Magnetic MI-contact Magnetic MAX-contact Magnetic MI-MAX-contact Magnetic MI-MI-contact Magnetic MAX-MAX-contact Bistable inductive ring sensor Bistable inductive ring sensor Bistable inductive ring sensor bistable inductive ring sensors bistable inductive ring sensors bistable inductive ring sensors Connection box for 1 limit switch Connection box for limit switches ATEX intrinsically safe ia IECEx intrinsically safe ia EPSI intrinsically safe ia Installation length 500 mm Installation length 356 mm Installation length 368 mm Installation length 386 mm Installation length 394 mm Valve made of 1.4571 G ½ (parts attached) Valve made of 1.4571 G 1 (parts attached) Valve made of 1.4571 G 1½ (parts attached) Valve made of brass G ½ (parts attached) Valve made of brass G 1 (parts attached) Valve made of brass G 1½ (parts attached) Oil + fat free for wetted surfaces acc. Yokogawa specification Certificate of Compliance with the order acc. E 1004: 004-.1 As /P +Test report acc. to E 1004: 004-. Material certificate for Insertion parts or flange connections acc. E 1004: 004-3.1 Pressure test report for metering system With flow table for recalculation + mm- scale PAMI test ( test points) PAMI test (4 test points) Delivery to Korea /KC With KC-mark in Korea Delivery to China /C For delivery to China Accessories for metering tube /MV /ME /M Gasket FKM (Viton) Gasket EPDM (conform to FDA, -30 C +100 C) ut galvanized steel Power supply for limit switches (transmitter relay) Instruction manuals /W1A /W1B /WA /WB /WE /WF /W4A /W4B /W4E /W4F /IEn /IDn KFA5-SR-Ex1.W / 115 V AC, 1 channel KFA5-SR-Ex.W / 115 V AC, channel KFA6-SR-Ex1.W / 30 V AC, 1 channel KFA6-SR-Ex.W / 30 V AC, channel KHA6-SH-Ex1 / 115/30 V AC, 1 channel, Fail Safe x KHA6-SH-Ex1 / 115/30 V AC, 1 channel, Fail Safe KFD-SR-Ex1.W / 4 V DC, 1 channel KFD-SR-Ex.W / 4 V DC, channel KFD-SH-Ex1 / 4 V DC, 1 channel, Fail Safe x KFD-SH-Ex1 / 4 V DC, 1 channel, Fail Safe Quantity of instruction manuals in English Quantity of instruction manuals in German 7 Only for tube P0 to P4 and float insertion code M (with magnet) Only for tube P0 to P4 and float insertion code M (with magnet) Only for tube P0 to P4 and float insertion code M (with magnet) Only for tube P0 to P4 and float insertion code M (with magnet) Only for tube P0 to P4 and float insertion code M (with magnet) Only for tube 6 with float code PDB Only for tube 7 with float code PDC Only for tube 7 with float code PDD Only for tube 6 with float code PDB Only for tube 7 with float code PDC Only for tube 7 with float code PDD Only with /GM1, /GR 4 Only with /GM3 5, /GR6 8 Only for /GR /GR8 Only for /GR /GR8 Only for /GR /GR8; only with /C Only for D4, A1 Only for size 01 and G0, T0 Only for size 01, 3, 0 and G0, T0 Only for size 0, 04 and G0, T0 Only for size 05, 06 and G0, T0 Only for G0 and tube 6, 7, P0 Only for G0 and tube P1 Only for G0 and tube P Only for G0 and tube 6, 7, P0 Only for G0 and tube P1 Only for G0 and tube P ot with /V1 /V6 Only for insertion and flange connections ot with /V1 /V6 Only for connections G0, T0, S4 except RAG04-G0SS-P and RAG04-T0SS- P Only for connections A1, D4 and RAG04-G0SS-P and RAG04-T0SS-P not for S4 and RAG04 with P not with /GR /GR8 not with /GR /GR8 not with /GR /GR8 not with /GR /GR8 n = 1 9 selectable *) n = 1 9 selectable *) Special order /Z Special design, must be specified separately. If /Z is selected, several Suffix of Model-Suffix can be changed to Z. *) If no instruction manual is selected, only a Short IM and in case of limit switches a DVD with instruction manuals is shipped with the flowmeter. All Rights Reserved. Copyright 011, Rota Yokogawa GS 01R01B10-00E-E 5th edition, June 7 017-00

8 PROCEDURE TO SEECT THE MODE CODE Please specify in the following order Measuring range for water/liquid or air/gas With or without optional limit switch First select the required measuring range from the flow table (last column) and specify the float insertion for the optional limit switch. Then the suffix code for the combination metering tube - float can be fixed. To size the Rotameter for other media or process conditions, please contact one of our Yokogawa Representatives. DIMESIOS METERIG TUBE 10 10 10 8 8 8 6 4 6 4 6 4 1 1 1 Inner thread type (T0; G0) Clamp type (S4) Flange type (D4; A1) Installation lengths and weights: Model RAG01 Process connection Inner thread Tube ength in mm Weight in kg 375 1.7 Clamp 375 1.9 6; 7; P0; P1 Flange 45.5 RAG3 Inner thread 375 1.7 RAG0 RAG04 RAG05 Inner thread Clamp Flange Inner thread Flange 6; 7; P0; P1 1.7 P.6 375 6; 7; P0; P1.0 P.8 6; 7; P0; P1 3.3 45 P 3.9 P.6 375 P4 7.1 P 5. 45 P4 8.7 Inner thread P4 375 7.1 Flange P 6.6 45 P4 11.1 RAG06 Inner thread P4 375 7. 7.1 1 Compatibility with former Rotameter RAGG / RAGH: Former model Tube Installation length in mm Model RAG RAGH01 6;7;G0 356 RAG01.../13 RAGH0 G1 368 RAG0.../14 RAGH04 G 386 RAG04.../15 RAGH06 G4 394 RAG06.../16 RAGH3 G1 368 RAG3.../14 RAGH05 G4 394 RAG05.../16 RAGG01 G0;G1 500 RAG01.../1 RAGG0 G 500 RAG0.../1 RAGG04 G4 500 RAG04.../1 GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa

9 VAVE /Vx e Option a b c d e KV value Thread mm mm mm mm m³/h /V1 G ½ 60 88 SW 30 63 0.66 /V G 1 100 110 SW 45 90. /V3 G 1½ 130 145 SW 70 100 17 /V4 G ½ 55 78 SW 5 63 0.66 /V5 G 1 75 93 SW 41 63. /V6 G 1½ 110 118 SW 60 90 17 d a c b IMIT SWITCH /GRx IMIT SWITCH /GMx 41 51 6 Ø 14 Dimensions in mm 16 /GR, /GR6 19.5 /GR3, /GR4, /GR7, /GR8 1 5.5 Dimensions in mm Ø 10.1 /GR /GR6 Ø 17.1 /GR3, /GR4, /GR7, /GR8 All Rights Reserved. Copyright 011, Rota Yokogawa GS 01R01B10-00E-E 5th edition, June 7 017-00

10 GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa

11 All Rights Reserved. Copyright 011, Rota Yokogawa GS 01R01B10-00E-E 5th edition, June 7 017-00

1 YOKOGAWA EECTRIC CORPORATIO Headquarters -9-3, akacho, Musashino-shi, Tokyo, 180-8750 JAPA Phone : 81-4-5-5555 Branch Sales Offices Osaka, agoya, Hiroshima, Kurashiki, Fukuoka, Kitakyusyu YOKOGAWA CORPORATIO OF AMERICA Head Office 1530 West Airport Blvd, Sugar and, Texas 77478, USA Phone : 1-81-340-3800 Fax : 1-81-340-3838 Georgia Office Dart Road, ewnan, Georgia 3065, USA Phone : 1-800-888-6400/ 1-770-53-7000 Fax : 1-770-54-098 YOKOGAWA AMERICA DO SU TDA. Praca Acapulco, 31 - Santo Amaro, Sáo Paulo/SP, BRAZI, CEP-04675-190 Phone : 55-11-5681-400 Fax : 55-11-5681-4434 YOKOGAWA EUROPE B. V. Euroweg, 385 HD Amersfoort, THE ETHERADS Phone : 31-88-4641000 Fax : 31-88-4641111 YOKOGAWA EECTRIC CIS TD. Grokholskiy per 13 Building, 4th Floor 19090, Moscow, RUSSIA Phone : 7-495-737-7868 Fax : 7-495-737-7869 YOKOGAWA CHIA CO., TD. 3F Tower D Cartelo Crocodile Building, o.568 West Tianshan Road, Shanghai 00335, CHIA Phone : 86-1-63966 Fax : 86-1-6387866 YOKOGAWA EECTRIC KOREA CO., TD. (Yokogawa B/D, Yangpyeong-dong 4-Ga), 1, Seonyu-ro 45-gil, Yeongdeungpo-gu, Seoul, 150-866, KOREA Phone : 8--68-6000 Fax : 8--68-6400 YOKOGAWA EGIEERIG ASIA PTE. TD. 5 Bedok South Road, Singapore 46970, SIGAPORE Phone : 65-641-9933 Fax : 65-641-606 YOKOGAWA IDIA TD. Plot o.96, Electronic City Complex, Hosur Road, Bangalore - 560 100, IDIA Phone : 91-80-4158-6000 Fax : 91-80-85-144 YOKOGAWA AUSTRAIA PTY. TD. Tower A, 11-118 Talavera Road, Macquarie Park SW 113, AUSTRAIA Phone : 61--8870-1100 Fax : 61--8870-1111 YOKOGAWA MIDDE EAST & AFRICA B.S.C.(C) P.O. Box 10070, Manama, Building 577, Road 516, Busaiteen 5, Muharraq, Kingdom of BAHRAI Phone : 973-17358100 Fax : 973-17336100 Apr. '15 GS 01R01B10-00E-E 5th edition, June 7, 017-00 All Rights Reserved. Copyright 011, Rota Yokogawa Subject to change without notice