Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

Similar documents
Catalog # Project. Comments. Prepared by

Project. Comments. Prepared by

Project. Comments. Prepared by

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Fixed Head Emergency Lights

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

UL AND CODE COMPLIANCE

To The. We ve Taken Exit Signs. Elegant Styling Industry-Leading Quality And Performance Easy, Trouble-Free Installation

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Industrial LED luminaires Exit and Emergency

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Self-Testing Industrial Series

Spectron Industrial Series

For complete photometric data, refer to the back cover of this brochure.

Installation Instructions Central Battery Units

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

SAVE THESE INSTRUCTIONS

LED EXIT SIGN WITH REMOTE CApability

RELIABILITY THROUGH TECHNOLOGY

CITADEL VERY DURABLE - EASY TO CLEAN AND SERVICE - STAINLESS HARDWARE - IMPACT RESISTANT LENSES

MIRRORLITE RECESSED EMERGENCY LIGHTING

New York City Approved. emergency lighting

The HP Series offers many advantages in an industrial environment

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

EMIU 720W Mini Inverter

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Exit and Emergency Lighting Products PRODUCT CATALOG

& EXIT SIGNS. & exit signs

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

LED Black Housing High Output Remote Capable

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Bavaria Downs. Chaska, MN. Lighting

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Class 1 Division 2 Hazardous Location LED Light - Corrosion Resistant for Marine (Saltwater) - Offsh

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

Table of Contents. Accessories Faceplates Polycarbonate Shields...46 Wire Guards... 47

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

UV16 vandal resistant, wet/damp location emergency lighting

Specification Sheet: EcoPark LED Parking Garage Fixture. Indoor/Outdoor

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

2018 LED Downlight Series

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Perimaliter Wallpacks

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Metalux SNLED LENSED LED

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

ARCHITECTURAL LED EMERGENCY LIGHTING

Encounter Metric Recessed LED Luminaire

Project. Comments. Prepared by

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Portable, Rechargeable LED Light Tower - 6, 10-Watt LEDs Lumen Hour Runtime

Emergency Lighting. Not Available in Canada. CE 464 CC 465 CCE 466 CEL 467 CEW 468 CWC 469 CSR 470 RME 471 CIR 472

MULTIRACK. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. Printed in Canada

Project. Comments. Prepared by

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

Installation Instructions

300 Watt LED High Bay Light Fixture VAC W Metal Halide Equivalent - 29,580 Lumens

Encounter Recessed LED luminaire

The Noah Emergency Lighting Wet Location Family RMRN PRMRN SWN SLBN

160 Watt High Intensity LED Flood Light - 24 LEDs - 20,500 Lumens W Halogen Equivalent

High Intensity Colored LED Light - 90 Watts - 30 LEDs - Red, Amber, Green, Blue

Echo Shapes 9.0 LED. EEW in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Metalux SNLED LENSED LED

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire

300 Watt Portable Work Area Light Tower - Extendible Tower W/ Wheels - (2) 150 Watt LED Lights

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Project. Comments. Prepared by

PathLinx Series LED Emergency Lighting

Taxonomies, Classifications, and Categories LED FLOODLIGHTS, WALLPACKS, BOLLARDS & LANDSCAPE LIGHTING

AtLite. Rival Series. Approved for New York City. Emergency Lighting

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

OkSolar LED Outdoor Luminaires

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

OutdoorXUPS-600AHV-8364

DELUGE FAMILY. Wet Location Emergency Units RPN CRPN RMN EBN

PGL350P W PS Wallpack

Project. Comments. Prepared by

300 Watt LED Pole Top Light Fixture VAC W Metal Halide Equivalent - Slip Fit Yoke

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.

Electric Actuator Instructions

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Installation and Operations Manual

OUTDOOR TRACK. LABELS Assembled in America

Transcription:

DESCRIPTION The LPX combo series is a UL 924 code compliant solution for exit and emergency requirements and is designed to operate for a minimum of 90 minutes during a outage. Features include a polycarbonate housing, LED sources for both the exit letters and the emergency heads, as well as a labor saving self-diagnostic option that automatically performs required NFPA testing. The Exit is field configurable for either red or green letters. The LED emergency heads are available with 25 feet or 50 feet of egress coverage. The LED sources and nickel cadmium battery require no maintenance. Product options include exits or combos with remote capacity that can be used for extended run times or to Sure-Lites SRP/SRM LED. SPECIFICATION FEATURES Electrical General Features - Field selected red and green sign letters standard on all units (units shipped red, field convertible to green with supplied parts). - Dual Voltage Input 20/277 VAC, 60 Hz - 240 VAC capable with 48 hour rechargable time - Sure-Lites EZ Key patented external battery disconnect feature prevents unnecessary battery drainage, saves on installation time - Solid-state voltage limited charger - Brownout circuit - Low-voltage disconnect - Test switch/ indicator light - Standard 24 hour recharge time (max) - Self-Diagnostic feature available as an option - Laser test capability with Self- Diagnostic Remote Capacity - Remote capacity is available in the combo (3 watts) or the exit (5 watts) - Remote capable versions are compatible with the Sure-Lites SRM and SRP series Emergency Heads - LED emergency heads are available with 00 lumens/head (25 feet of coverage) or 200 lumens/head (50 feet of coverage) of emergency light output. - Heads can be mounted to top or sides of exit Housing Construction - All components are injection molded, color stable, high impact UL 94-5VA rated polycarbonate material - White or black textured finish standard - Components are of snap-fit construction to enable under 5-minute installation - Molded-in wireways facilitate internal wire routing and connections - Field adjustable snap-out or snap-in chevron directional indicators have full 3/4 stroke - Knockout provided on housing for surface attachment mount install - Universal exits can be field configured as single face or double face - Snap-fit canopy with captive mounting screws included with all exits Catalog # Project Comments Prepared by - Combo can be ceiling, wall, or end mounted - Universal J-box mounting pattern Code Compliance - UL 924 Listed - UL Damp Location (0 C - 40 C) - Life Safety NFPA 0 - NEC/OSHA - Most State and Local Codes - California Energy Code Warranty - Fixture: 5-Year - Battery: 7-year pro-rata Type Date LPXC SERIES POLYCARBONATE COMBO SURFACE MOUNT LED LAMPS EMERGENCY EXIT LIGHTING SELF DIAGNOSTICS REMOTE CAPACITY NICKEL CADMIUM BATTERY LPXC LPX 9 3/4" 502 3" 330 2 /8" 54 3" 330 2 /8" 54 ENERGY DATA 7 /2" 9 Input Voltage Input Power 20 Volts 2.2 watts 240 Volts 2.5 watts 277 Volts 3.2 watts TD505032EN 207-9-

CATALOG LOGIC Series Coverage Remote Capacity Color Self Diagnostics Full Catalog Logic LPXC = LED polycarbonate Combo 25 = 25 feet _ = 0 watts R3 = 3 watts LPXC = LED polycarbonate Combo 25 = 25 feet _ = 0 watts R3 = 3 watts _ = white LPXC = LED polycarbonate Combo 50 = 50 feet not available _ = white LPX = LED polycarbonate Exit not applicable R5 = 5 watts _ = white _= no self diagnostics LPXC25, LPXC25R3, LPXC25SD, LPXC25R3SD LPXC25BKSD, LPXC25R3BKSD LPXC50SD, LPXC50BKSD LPXR5SD, LPXR5BKSD REMOTE LOGIC SEL Series Outdoor Capable Remotes Series SRPA Single Head Remotes Double Head Remotes Catalog number SRPA29 SRP/SRM3 SRP/SRM25 SRP/SRM30 SRP25D/ SRM25D SRP50D/ SRM50D Watts Consumed 3.5.25 2.5 4 2.5 5 8.2 SRP60D/ SRM60D Catalog Number Remote Watts Available # of SRPA29 SRM3 SRM25 SRM30 # of SRP25D/ SRM25D # of SRP50D/ SRM50D fixture will # of SRP60D/ SRM60D fixture will LPXC25R3 3 NA 2 NA NA NA LPXR5 5 4 2 2 NA SRP SRPD SRM SRMD SRPA WHITE SRPA BLACK SRPA BRONZE SRPA SILVER

.5.2 0.7 0.4 0.2 0.2 0.2 0.2 0.3 0.5 0.9.3.4 0.9 0.9.3.4.0 0.6 0.3 0.2 0.2 0.2 0.2 0.3 0.6.0.4.3 0.9 0.9.0.4.3 0.8 0.5 0.3 0.2 0.2 2.5.8 0.9 0.4 0.2 0.2 0.2 0.2 0.3 0.6.2 2 2.6.9.2.6 2.5 2.3.5 0.7 0.4 0.2 0.2 0.2 0.2 0.4 0.7.5 2.3 2.5.6.2.9 2.6 2.2 0.6 0.3 0.2 0.2 2.7.8 0.8 0.4 0.2 0.2 0.2 0.2 0.3 0.5 2.2 2.9 2.4.7 2.8 2.5.4 0.7 0.3 0.2 0.2 0.2 0.2 0.3 0.7.4 2.5 2.8.7.4 2 2.9 2.2 0.5 0.3 0.2 0.2 0.9.3.9 2.3 2.6 0.7 0.4 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.4 0.7.6 2 2.3.9.3 0.9.2 2.0 3.0 3.5 3.0 2.0.2 0.7 0.5 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.5 0.7.2 2.0 2.9 3.5 3.0 2.0.2.7.3 2.2 3.3 3.7 3.0.9.2 0.7 0.4 0.3 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0.2 0.3 0.4 0.7.2.9 3.0 3.7 3.3 2.2.3.8.2 Sure-Lites PHOTOMETRY LPXC25 4 5 6 7 8 9 0 25ft X Y Z Orient Tilt -0.5 0.25 7.5 25 27 0.5 0.25 7.5 55 27 6.5 0.2 7.5 25 27 7.5 0.22 7.5 55 27 33.5 072 7.5 25 27 25 ft. 34.5 073 7.5 55 27 50.5 032 7.5 25 27 5.5 035 7.5 55 27 67.5 0.093 7.5 25 27 68.5 0.096 7.5 55 27 84.5 0.054 7.5 25 27 85.5 0.058 7.5 55 27 0.5 0.05 7.5 25 27 02.5 0.09 7.5 55 27 LPXC50 2 4 3 50ft 50 ft. X Y Z Orient Tilt 24.25 0.33 7.5 58 40 24.75 0.33 7.5 22 40 74.75 0.3 7.5 22 40 74.25 0.292 7.5 58 40 ***The Rule of Thumb spacing guidelines are designed to achieve foot-candle average and 0 foot-candle minimum with a 40: maximum/minimum ratio. The corridor used is 00 feet long, 9 foot ceiling with a 6 foot wide walkway and 3 foot path of egress. The reflectances are 80% ceiling, 50% walls and 20% floors. The fixture mounting height is 7.5 feet. Eaton assumes no responsibility for local requirements or specific project variables. This is a guideline to be used as a design aid, not as guarantee of any code compliance.

TECHNICAL DATA Exit Lamps LPXC Series Exits use energy efficient, long life LED s to provide uniform diffuse illumination of the exit face. These red and green LEDs require no maintenance and consume less than one watt, on average. The LED s are ed from AC input during normal operation and from the battery during a outage. Emergency Heads The LPXC series features long life LED s for the emergency source. These LED s require no maintenance and are available with 00 lumens/ head or 200 lumens/head output. The heads are adjustable and can be mounted on the top or side of the exit housing. Housing Construction Rugged, durable, injection molded polycarbonate materials are used throughout the LPXC Series. All structural components are designed with reinforcing ribs to add additional rigidity and to maximize structural integrity. These materials are impact and scratch resistant, and they have been UV stabilized to resist discoloration due to age and ultraviolet radiation. All components are designed to be of snap-fit construction - no mechanical fasteners to facilitate installation in under 5-minutes. Any components required for installation (wirenuts, wire leads, universal metal J-box bracket, etc.) are all included. The universal design of the LPXC Series enables exits to be configured as single face or double face in the field. All LPXC series Combo s can be wall, ceiling, or end mounted; a rugged, snap-fit, low profile canopy with captive screws is included with every exit for ceiling and end mounting application. Lens Lenses for the LPXC Series are made from durable, impact resistant polycarbonate. All exit faces are designed with full 3/4 stroke snap-out or snap-in chevron directional indicators to insure maximum visibility and compliance with the latest codes. Units come with red lenses installed and green lenses included for field selectable red or green signs. Brownout Circuit The brownout circuit on Sure-Lites exits monitors the flow of AC current to the exit and activates the emergency lighting system when a predetermined reduction of AC occurs. This dip in voltage can cause fixtures to extinguish resulting in a loss of normal lighting even though a total failure has not occurred. Solid-State Transfer The LPXC Series incorporates solid-state switching which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps using DC. Upon restoration of AC, the DC will be disconnected and the charger will automatically recharge the battery. Low Voltage Disconnect When the battery s terminal voltage falls, the low-voltage circuitry disconnects the lighting load. The disconnect remains in effect until normal utility is restored, preventing deep battery discharge. EZ Key External Power Disconnect The EZ Key is an external disconnect. The patent EZ Key technology keeps the battery disconnected during the construction cycle. This prevents battery wear and ensures the battery maintains its charge for the inspection process. Simply remove the key once the building is commissioned. Test Switch/Power Indicator Light A test switch located on the side of the exit permits the activation of the emergency circuit for a complete operational systems check. The Power Indicator Light provides visual assurance that the AC is on. Sealed Nickel Cadmium Battery Sure-Lites sealed nickel cadmium batteries are maintenance-free with a life expectancy of 0 years. The sealed rechargeable nickel cadmium battery offers high discharge rates and stable performance over a wide range of temperatures, from 0 C to 40 C (32 F to 04 F). Self Diagnostics Option The self-diagnostic unit will automatically perform all tests required by UL924, and NFPA 0. The system indicates the status of the fixture at all times using the LED indicator near the test switch on the side of the unit. A 90 minute battery (emergency mode) simulation test will occur every 2 months. A 30 second battery simulation test will occur every 30 days. Laser Test The Self-Diagnostic option include a laser pointer testing cability. Activation of the photocell test button with a laser pointer will simulate loss of AC and engage the emergency operation of the exit and emergency heads. Warranty All Sure-Lites products are backed by a firm five-year warranty against defects in material and workmanship. Maintenance-free, long-life, sealed nickel cadmium batteries carry a sevenyear pro-rata warranty. EZ Key Laser tester Part Number = LASER (sold separately)

SELF DIAGNOSTIC TESTING OPERATIONS The Sure-Lites Eagle Eye Self Diagnostics is continuously monitoring your emergency fixture, and will signal any failure through the 3 color indicator LED. Initial Operation: When the unit is first ed up it will go into a 24 hour fast charge and the indicator LED will pulse green. Once the unit has fully charged it will perform a self calibration. After self calibration, the LED will change to steady green indicating the unit is fully charged and float charging the battery to maintain readiness. Automatic Testing: The unit will perform a battery capacity, lamp/led, and charge circuit test every 30 days for 30 seconds. During this time, the indicator LED will change to a steady yellow. It will perform a full battery capacity (90 minute) test once per year. During this time, the indicator LED will change to a blinking yellow. Manual Testing: 0 Second Installation test Press and release the test button once during fast charge (blinking green) to initiate a 0 second quick test. The sign will switch to emergency mode for 0 seconds allowing the installer to verify proper installation of the unit, and the LED indicator will turn solid yellow. 30 Second Test - Press and release the test button once during float charge (steady green). The indicator LED will turn steady yellow to indicate the unit is performing a 30 second test of the batteries and lamps/leds. 90 Minute Test - Press and release the test button a second time during a 30 second test (steady yellow) to change to a 90 minute test. During this test, the LED indicator will change to blinking yellow, and the circuit will perform a full battery capacity, charge circuit, and LED test. Canceling Test Press and release the test button during the 90 minute test (flashing yellow) to return the fixture to its original state (fast charge or float charge) Laser Test: The SEL SD products are equipped with a Laser Test function that allows the unit to be manually tested without the need to physically press the test button. Shining a laser pointer in the hole marked LASER TEST on the bottom of the unit has the same effect as a press and release of the test button. Clearing Failure Codes: A battery failure (LED two blink red) can be cleared by replacing the battery. Disconnecting the battery and AC, or performing a full 90 minute discharge will reset the error code, however, it will return if the battery is faulty Charge Circuit (LED three blink red) and lamp/led failure (LED four blink red) will clear when the unit successfully passes a manual or automatic 30 second test. SELF DIAGNOSTIC TESTING OPERATIONS Indicators: LED Off - No to unit, emergency mode. LED Steady Green - Unit is fully charged and is float charging the battery to maintain readiness. LED Green Pulse - Unit is in a 24 hour fast charge of the battery. LED Two Blink Red - Battery has failed a capacity test, or the battery is disconnected. See Clearing Failure Codes above. LED Three Blink Red - Battery charge circuit has failed. See Clearing Failure Codes above. LED Four Blink Red - Lamps have burned out, or on an EXIT/Combo, 50% or more of the LEDs have failed. See Clearing Failure Codes above. LED Steady Yellow - 30 second test or 0 second quick test (Fast Charge only). LED Blinking Yellow - 90 minute test. Maintenance: None required. Replace the batteries as needed according to ambient conditions. However, we recommend that the equipment be tested regularly in accordance with local codes. SURE-LITES OFF - EMERGENCY MODE / POWER OFF STEADY BLINK GREEN - FAST CHARGE STEADY GREEN - FULL / FLOAT CHARGE STEADY YELLOW - QUICK TEST STEADY BLINK YELLOW - 90 MINUTE TEST 2 BLINK RED - BATTERY FAILURE 3 BLINK RED - CHARGE CIRCUIT FAILURE 4 BLINK RED - LAMP/ LED FAILURE Eaton 2 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. TD505032EN 207-9-6