MP/MTFL LIGHT FIXTURE (Dimming)

Similar documents
HBC-20 - LED HIGH BAY

A S S E M B L Y I N S T R U C T I O N S

Installation Precautions. Use Precautions. Specifications

Safety, Installation and Service Manual Models 1952, 1953 & 1972

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

Swing Arm Magnifying Lamp

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Automatic Emergency Light

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Air Lift. Kit PERFORMANCE INSTALLATION GUIDE Scion xb

Microscope light manual

Owner s Manual & Safety Instructions

Component Size Weight Capacity

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Heavy Duty Four Wheeled Walker

Lionel Lionelville Firehouse Owner s Manual

SOLAR DASH CHARGING SYSTEM USER GUIDE

Instruction Manual. Fudge Puppy Display Case

IMPORTANT SAFETY INFORMATION

MINISTICK TM UV Germicidal Ultraviolet Light

MaxLite LED Enclosed & Sealed Jelly Jars

Seat Track Slide Installation Instructions

INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES

INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

POWER GEAR SLIDE-OUT MANUAL

Tissue Master. User Manual

Level One Electric Vehicle Charging Station Wall Mount Product Guide

21", 33", 45", & 61" Installation & Operation Manual

GM 2500,3500 Nerf Bar Installation Instructions

PACIFICA Shower Cabin Installation Instructions

Remote Vehicle Control System. Keyless Entry and Convenience System

Installation manual. 2 Suspension System. Ford F150 4WD and 2WD. Part # Part # Ford F150 4WD and 2WD

LIGHTNING PLUS 120 WATT / 6 OUTLET VOLT POWER SUPPLY & STROBE LIGHT KIT 6 Different Light Patterns 8006 SERIES INSTALLATION INSTRUCTIONS

Installation manual. 2 front / 1 rear spacer kit Jeep Wrangler JK 2 & 4 door Part # 42005

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

UV-AIRE AIR PURIFYING SYSTEM

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

Remote Vehicle Control System. Keyless Entry & Remote Start System

Air Curtain. Installation, Operating and Maintenance Instructions

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

Model FM2642 Wall Mount. Full Motion Television Wall Mount

INSTALLATION & OPERATION MANUAL

MaxLite LED UTILITY WRAP FIXTURES

Series 2100 Operating Instructions

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

TOTALIZER-TRANSMITTER

Installation manual. 1.5 front leveling kit. Nissan Titan. Part # Part # Important customer information: Nissan Titan

Rear Weight Kit 19A , OEM-19A-218 & M060

Owner s Manual & Safety Instructions

Installation Instructions

Air Lift. Kit PERFORMANCE INSTALLATION GUIDE Scion xb

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Fluorescent Ring Light with Dimmer INSTRUCTIONS

Rear Strut Bar Installation Guide v1.0 (Dec 2014) Part No. EC

USER S OPERATING AND INSTRUCTION MANUAL

SpectroLED 9 PRODUCT GUIDE

/99 LIONEL. Lionel Route 66 Cafe Owner s Manual

SpectroLED 9 PRODUCT GUIDE. Genaray SpectroLED 9 Guide Page 1

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Installation Instructions

LED LARGE WALL PACK (CUTOFF & STANDARD)

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

IMPORTANT! 09 to Current Straight Up Electric Billet Center Stand. Dealer and/or Customer must complete the following items: Center Stand Checklist

Manual Operated Floor Jack

PIAA Multi-Fit 005/1100X Light Bracket Kits

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Owner s Manual & Safety Instructions

PUSH BUTTON KEY CABINET

Submersible Pond Pump with UV 800 Gallons Per Hour

Lionel Red Baron Pylon Owner s Manual /01

Installation Instructions

series USER MANUAL

Users Manual Certified Series Direct Drive Pump 1-7 LPM

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

Kit PSI Air Shock Controller

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Installation manual 2 Leveling kit GM x 4. Part # Part # Important customer information: GM x 4

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

37SCENE 46SCENE 79SCENE

CPL 100 Owner's Manual

Manual Operated Floor Jack

USER S OPERATING AND INSTRUCTION MANUAL

Endlinks Installation Guide v1.0 (Feb 2015) Part No s: EC ; EC ; EC

- INSTALLATION INSTRUCTIONS -

RECHARGEABLE 24 LED WORK LIGHT

The Esteem Steel Self Propel Wheelchair Instructions

IMPORTANT SAFETY INFORMATION

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

TH400 STREETFIGHTER SERIES VALVE BODY MANUAL/AUTO VALVE BODY INSTALLATION INSTRUCTIONS

C35. Assembly Instructions. Mobius Floor Lamp & C Page 1 of 7. Prepare Base (Figures 1& 2)

Installation Power Management Unit Battery Cables and Battery Harness

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Transcription:

Robern 701 N. Wilson Ave. Bristol, PA 19007 800.877.2376 MP/MTFL LIGHT FIXTURE (Dimming) General Notes 1. It is important that the armored cable be installed during electrical rough in. 2. When surface mounted, the armored cable should be routed behind the cabinets through the wall cavity. 3. When recessed mounted, the armored cable is routed above the master fixture then back down to the remote. 4. The light fixtures can be dimmed with the proper dimmer. See Page 7 for recommended dimmers. 5. When using the fixtures between cabinets use the 1.5GKIT (sold separately) 6. If you experience any problems with your light, or require parts, contact your dealer or Robern customer service directly between 8 and 5p.m.E.S.T. Robern, Inc. 701 North Wilson Ave - Bristol, Pa 19007 800-877-2376 Fax 215-826-9633 Limited Warranty One Year Term ROBERN warrants to the original purchaser that, it will, at its election repair, replace, or make appropriate adjustment to products made by this company shown to have significant defects in material or workmanship which are reported to ROBERN in writing within one (1) year from the date of delivery. ROBERN is not responsible for installation costs. The warranty is void in the event the product is damaged in transit, or if damage or failure is caused by abuse, misuse, abnormal usage, faulty installation, damage in an accident, improper maintenance, or any repairs other than those authorized by ROBERN. At the expiration of the one year warranty period, ROBERN shall be under no further obligation under any warranty, expressed or implied, including the implied warranty of merchantability. ROBERN shall not be liable for any consequential damages arising out of or in connection with the use or performance of its products. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Any liability against ROBERN under any implied warranty, including the warranty of merchantability, is expressly limited to the terms of this warranty. Permission to return any merchandise under this warranty must be authorized by ROBERN and returned prepaid by the purchaser. Claims under this warranty should be sent directly to your dealer. MPFL Light Fixture 209-1030 cab fax #1030 1 Part List MP/MTFL Light Fixture A. (1) Light Fixture master B. (1) Light Fixture remote C. (2) Bulb Cover D. (2) Fluorescent Bulb E. (4) End Cap F. (1) 72 Armored Cable G. (4) Connecting Blocks (Supplied separately w/1.5gkit) Hardware Bag Containing the Following: H. (4) Cross Bracket I. (4) Keyhole Bracket J. (4) Mounting Bracket K. (4) #6 Thumbscrews L. (4) Wire Nut M. (4) #10 x 3/4 Flat Head Screw N. (4) #10 x 3 Pan Head Screw O. (16) #10 x 1/2 Pan Head Screw Do not throw away Carton until you have checked the carton and all internal packing completely for hardware. INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH HOMEOWNER. RECORD SERIAL NO. 209-1030 (replaces 209-1033) MP/MTFL LIGHT FIXTURE

1. Wiring the MP/MTFL Light Fixture 1. The fixture pair is configured as a Master and Remote. The Master has the wiring compartment while the Remote does not. See Figure A 2. The wiring compartment of the Master contains supply and ground connections and the fixture-to-fixture connections for the supplied armored cable. See Figure B. 3. Wiring of the units before installing the lights is recommended. 4. Wire the light fixtures as shown in Figure B. Fig. A 2. Remove the access door to reach the wiring inside the compartment 1. Loosen these screws on each end of the compartment 209-1030(replaces 209-1033) MP/MTFL LIGHT FIXTURE 2

MP/MTFL Fixture Wiring Diagram (Dimming) Fig. B MASTER FIXTURE REMOTE FIXTURE 3/8 ARMORED CABLE R R Y Y B B BALLAST W B G BALLAST BOX IN THE REMOTE FIXTURE, BE SURE TO CONNECT EACH YELLOW WIRE TO EACH YELLOW WIRE AND EACH BLUE WIRE TO EACH BLUE WIRE (A TOTAL OF 4) TOGETHER USING THE WIRE NUTS SUPPLIED. THE COLOR OF THIS SWITCH WIRE CAN VARY ACCORDING TO MANUFACTURER 15 A CIRCUIT 3 209-1030 (replaces 209-1033) MP/MTFL LIGHT FIXTURE

2. Installing the MP/MTFL Light fixture during a cabinet-to-cabinet installation 1. Attach the light fixture to Connecting Blocks (G) (sold separately as 1.5GKIT) by inserting and tightening the fixture to the connecting blocks using screw (M). See Figure C & D. 2. Slide the Fluorescent Bulb (D) into the Bulb cover (C) and push them into the lamp sockets, and twist. See Figure H & I on page 6. 3. Snap the End Caps (E) over Bulb cover (C) being sure that the threaded stud at the end of the fixture protrudes out of the end of the End Cap. See Figure J on page 6. 4. Thread the Finger Nuts (K) onto the threaded studs on each end. See Figure K on page 6. 5. Test the lights; if there is a problem refer to the troubleshooting section starting at the bottom of page 8. M Fig. C 3. Installing the MP/MTFL Light Surface mounted with a single cabinet 1. Using screw (O) and cross bracket (H) attach mounting bracket (J). See Figure E & F on page 5. 2. Attach keyhole bracket (I) using screw (O) to the cross bracket (H). See Figure E & F on page 5. 3. Attach the light fixture to mounting brackets (J) by inserting and tightening the fixture to the connecting blocks using screw (O). See Figure C & G. 4. Slide the Fluorescent Bulb (D) into the Bulb cover (C), push them into the lamp sockets, and twist. See Figure H & I on page 6. 5. Snap the End Caps (E) over Bulb cover (C) being sure that the threaded stud at the end of the fixture protrudes out of the end of the End Cap. See Figure J on page 6. 6. Thread the Finger Nuts (K) onto the threaded studs on each end. See Figure K on page 6. 7. Test the lights; if there is a problem refer to the troubleshooting section starting at the bottom of page 8. See figure C Fig. D Note: Connecting blocks (G) are attached to cabinet before installation (1.5GKIT sold separately) G 209-1030(replaces 209-1033) MP/MTFL LIGHT FIXTURE 4

4. Installing the MP/MTFL Light Recessed mounted with a single cabinet 1. Using screw (O) and cross bracket (H) attach mounting bracket (J). See Figure E & F. 2. Attach the light fixture to mounting brackets (J) by inserting and tightening the fixture to the connecting blocks using screw (M). See Figure C & G. (Note: Keyhole bracket not required.) 3. Slide the Fluorescent Bulb (D) into the Bulb cover (C) push them into the lamp sockets, and twist. See Figure H & I on page 6. 4. Snap the End Caps (E) over Bulb cover (C) being sure that the threaded stud at the end of the fixture protrudes out of the end of the End Cap. See Figure J on page 6. 5. Thread the Finger Nuts (K) onto the threaded studs on each end. See Figure K on page 6. 6. Test the lights; if there is a problem refer to the troubleshooting section starting at the bottom of page 8. O J H Fig. EE I* Attach the lights to the Mounting Brackets (J) using the screws (M). Refer to figure C. O* *Not required for recessed cabinet Fig. F Using the screws (O) attach the brackets (J) to cross brackets (H) and keyhole brackets (I). Fig. G Note: Use 8 additional screws when mounting sidekit. Screw two #10 x 1/2 screws into each bracket on sidekit mirror. Leave enough room under head for a penny to slide. Hang on keyholes. Adjust screws if required for snug fit. 5 209-1030 (replaces 209-1033) MP/MTFL LIGHT FIXTURE

Slide bulb into bulb cover D Fig. H Fig. J E C Snap end caps over each end Fig. I Fig. K For push and turn lampholders, push bulb and cover intoand cover into lampholder and twist 90 For push-in lampholders, push bulb and cover in lampholder. Thread thumbscrews onto studs on each end K 209-1030(replaces 209-1033) MP/MTFL LIGHT FIXTURE 6

Notes Concerning Dimming Lamps The dimmable electronic ballast are designed for F17, 25, 32 T8 Lamps only. The lamps supplied with the fixture are the best color rendering lamps available. Suitable Dimmers The Lightolier dimmer are recommended because the have an adjustment to set the minimum light level. With the adjustment wheel you can set the light level so that the lamps will not flicker or go out at the minimum setting. Minimum setting is approximately 10% of full brightness. Dimmers: Lightolier ZP600EB or MSP600EB Other Dimmers: Dimmer suitable for Mark 10 or Mark X Powerline ballast can also be used Installation The dimmer uses standard wiring used with standard dimmers. The cable between the fixtures allows the use of on ballast to operate 2 fixtures. If the armored cable cannot be used due to wall access or distances between the fixtures, standard plastic jacketed cable can be used if local code allows. Maximum wire length should be kept to under 6 feet. Grounding of the remote fixture will be necessary. To avoid lamp flickering, it is extremely important that the fixtures be grounded and the supply wire ground is connected to both the fixture and the ballast. Positive contact of the bulb in the socket is also important. Initial start up New fluorescent lamps go through a process of initial forming in their first 100 hours of operation. Especially rapid changed are occurring during the first 10 minutes of operation and it is undesirable to even test the dimmer until the lamps have burned at full power for 10 minutes. After this 10 minute warm up at full power you can set the minimum light level using the thumbwheel on the dimmer. Adjust the dimmer by sliding to its lowest setting and turn the wheel until the lamps light evenly without flicker. Once the installation is working satisfactorily operate the lamps primarily at full brightness are approximately 100 hours before using them for extensive periods of dimming. 7 209-1030 (replaces 209-1033) MP/MTFL LIGHT FIXTURE

Troubleshooting Grounding Both fixture and ballast must be connected to a building ground Filaments T8 lamps require both pins to be secure in order to operate dim, even though they can produce light at full power with only one pin connected. The fixtures are supplied with wither push and turn or push-in lampholders. For push and turn lampholders, the bulb must be turned 90 for correct operation. For push-in lampholders, be sure that the bulbs are fully engaged for proper operation. If the lamp end pins are dirty, clean with scotchbrite and reinstall. Premature end blackening If one end of one lamp is black after only a few days, and no other lamp has become black, check for faulty filament (Pin) connections or faulty ground connections before assuming the lamp is defective. Final note for electrician If everything is working fine leave the lamps on full brightness so that the lamp forming process can be completed as soon as possible. Explain to the customer that 4 days (100 hours) of full bright operation are needed before the lamps can be dimmed without damaging them. WARNING: RISK OF FIRE Most homes built before 1985 have wire rated 60 C. Consult a qualified electrician before installing for supply connections. Use wire rated for at least 90 C. For more information, contact a licensed electrician. 209-1030 MPFL LIGHT FIXTURE INSTRUCTIONS 209-1030(replaces 209-1033) MP/MTFL LIGHT FIXTURE 8 MPFL Light Fixture 07/2/10 cab fax #1030