EUROPEAN HIGH VOLTAGE FUSES

Similar documents
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

FUSES. Safety through quality

Medium voltage fuses Medium voltage fuses

High-voltage high-breaking capacity VV fuse-links

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

INDUSTRIAL POWER SUPPLIES SFL-SERIES

IEC Standard Back-Up Fuse-Links

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

High voltage high-breaking capacity VV fuse-links

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

FUSE TECHNOLOGY Ambient temperature

Table 1.-Elemsa code and characteristics of Type K fuse links (Fast).

MAGNETIC MOTOR STARTERS

Fuses Introductory Information

High-voltage high-breaking capacity VV fuse-links

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

FUSES FOR SEMICONDUCTORS

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

AF series contactors (9 2650)

EMPAC Metal enclosed capacitor bank for wind applications

3.2. Current Limiting Fuses. Contents

LG HRC Power Fuses ISO 9001 ISO 14001

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

THE PROTECTION OF INDUSTRIAL CAPACITOR BANKS BY CURRENT LIMITING FUSES. By M.J. Smart and B. Wadcock

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

AF series contactors (9 2650)

Medium voltage products. Fuses

Product Selection Guide

High-Voltage Fuse Links according to IEC

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Medium Voltage current limiting Fuse links

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Medium Voltage Distribution. Fuses. from 3.6 to 36 kv. Catalogue 2012

Air-insulated switchgear UniGear type ZS1

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

MV SWITCHGEAR 511. CF / SOLEFUSE / TEPEFUSE / MGK MV current limiting fuses With thermally operated striker From 3.6 to 36 kv

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

Medium Voltage current limiting Fuse links

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

High voltage current limiting Fuse links type CEF

CP Automatic capacitor bank

Medium voltage products. Fuses

MODVAR Low voltage reactive power compensation modules Installation manual

Section 1 Introduction to the Presentation

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Medium voltage fuses - European Fuses

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

FX Full-Range Current-Limiting Fuse

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Phase + Neutral, neutral on left side

LV Capacitor CLMD03 Power Module Instruction manual

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

NB1 Miniature Circuit Breaker

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

PROTECTION AND CONTROL

Design Standards NEMA

EE 741 Over-voltage and Overcurrent. Spring 2014

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

WHITE PAPER. DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment. E-T-A Circuit Breakers

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

ZX-Family Gas-insulated medium voltage switchgear

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

MEDIUM VOLTAGE DIN Fuse-Links

HD4. Gas insulated MV circuit-breakers kv A ka

What is included in a circuit diagram?

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Low Voltage Industrial Type T Fuse Links

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Technical Specification For Outdoor Substation Harmonic Filter Banks

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

Mica Element Support. Compacted Quartz Sand. Length B

Phase + Neutral, neutral on right side

Technical specifications

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Medium Power Film Capacitors

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Glossary/Technical appendix

NEXT STEP B) SAFETY :

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Transcription:

EUROPEAN HIGH VOLTAGE FUSES AS PER IEC 60282 EDUPACK TRAINING MODULE 2012 HH DIN NF

MEDIUM OR HIGH VOLTAGE FUSE? High Voltage is the official definition provided by the standard. High Voltage starts just when Low Voltage ends. Medium Voltage is the current and popular naming for utilities and users Maximum voltage range : 72 500V Our fuses: up to 40 500 volts 2

PROTECTION REQUIREMENTS FOR SAFETY - QUALITY - ECONOMY Safety: short-circuits can be dangerous for people and can destroy equipments Quality: of the power supply and quality of the equipments Economy: the protection can help to reduce the cost of the equipments and the cost of the maintenance. 3

SAFETY QUALITY - ECONOMY Medium voltage fuses can provide: Reliability Enclosed operation Speed High breaking capacity No maintenance before a short-circuit Small maintenance after a short-circuit Selectivity (or discrimination) Improved power quality Future system growth without problems Universal Low power consumption Price 4

TWO MAIN DIFFERENT CLASSES 2 main classes in the international publication IEC 60282-1: Associated fuses also known as back up current limiting fuse are capable of interrupting all currents from maximum interrupting rating ( breaking capacity ) down to minimum interrupting rating. General purpose fuses can interrupt all currents from maximum interrupting rating ( breaking capacity ) down to the current that causes the fuse element to melt in no less than 1 hour. 5

INTERRUPTING TESTS Current I 1 : maximum interrupting rating (breaking capacity) Test voltage is 87% of fuse rated voltage Current I 2 : maximum energy test Test voltage is 87 % of fuse rated voltage Current I 3 : minimum interrupting current Test voltage is 100 % of fuse rated voltage Associated fuse (Backup protection fuse) : I 3 is the rated minimum interrupting current. General Purpose: 1h. I 3 is the current that causes melting of the fuse in no less than General purpose fuses may experience damage due to overheating if subjected to currents that cause them to interrupt at times significantly more than 1 hour. 6

TEMPERATURE RISE TEST The fuse current rating is defined for 40 C ambient temperature. Typical limits are: Body: 115 K temperature rise i.e. 155 C maximum temperature Contacts: 65 K temperature rise i.e. 105 C maximum temperature 7

TIME VS CURRENT CURVE Tests conducted in the following time ranges: Associated fuse (Back-up fuses): from 0.01s to 600s General Purpose fuses: from 0.01s to 1h 8

FUSES CLASSIFIED AS «PARTIAL RANGE» OR BACK-UP PROTECTION FUSES Associated fuses are therefore recommended when they must not interrupt low values of fault currents. They are working in association with a circuit breaker and are generally used for: The protection of circuits with motors The protection of capacitors The protection of transformers 9

FUSES CLASSIFIED AS «PARTIAL RANGE» OR BACK-UP PROTECTION FUSES As for low voltage fuses, the main components are: One or several fuse elements in parallel Body made of ceramic or fibre glass Terminals Filler: the filling material is sand 10

FULL-RANGE FUSES DESIGN FOR APPLICATIONS WITH LOW OVERLOADS There are mainly two kinds of design: Design 1: The use of alloys or eutectics with low melting temperature. Design 2: The use of two systems in series in the same casing like low voltage «Dual Element»: The 1st system contains classic fuse elements for short circuit currents The 2nd system contains a spring loaded element designed to interrupt low overloads Design 2 is more often used 11

TRANSFORMER PROTECTION FUSES THREE MAIN TYPES Indoor type fuses Installed in the primary of the transformer Outdoor type fuses Protecting overhead transformers Oil-immersed Fuses Protecting oil immersed transformers 12

INDOOR FUSES FOR HIGH VOLTAGE PANELS AND SWITCHBOARDS Dimensions to the standards: UTE 64 210 DIN 43 625 When fitted with a striker pin controlling the operation of a circuit breaker, the striker pin must prove it has enough energy. 13

OUTDOOR FUSES The fuses are Associated type and refer to DIN 43 625 or HM 24.94.035 C. Outdoor applications require watertight equipment as well as the capacity to withstand UV and sand storms. 14

OIL-TIGHT FUSES Oil Tight Fuses are immersed in the dielectric liquid: They have a total imperviousness to oil They must operate at temperatures generally close to 100 C They are fitted inside of high-voltage/low-voltage transformers above the coils General purpose or back up type fuses can be used 15

SELECTION OF RATED VOLTAGE U N OF THE FUSE IEC 60282-1 When used on a three-phase earthed system U N = largest line to line voltage When used on a single-phase system U N = 115% of the largest single-phase circuit voltage When used on a three-phase unearthed system, discussion about: Double earthed faults Capacitive currents in the case of phase to earth fault 16

SELECTION OF RATED VOLTAGE U N OF THE FUSE IEC 60282-1: CONDITIONS IN NORMAL SERVICE Altitude CEI 60282-1 2.1 b) Rated voltages and insulations level in this recommendation apply to fuses intended for use at altitudes not exceeding 1000 m 17

SELECTION OF RATED VOLTAGE U N OF THE FUSE IEC 60282-1: CONDITIONS IN NORMAL SERVICE Values given by the IEC belongs more particularly to the fuse holders and isolators. IEC specifies 5% voltage derating at 1500 m and 20% at 3000 m. Our fuse rated 40.5 KV with epoxy body can certainly operates under 32 KV at 3000 m and is only 300 mm long. Therefore all our fuses rated up to 36 KV in our catalogue do not need to be derated for altitudes lower than 3500 m. 18

INFLUENCE OF THE ENVIRONMENT ON THE FUSE CURRENT RATING I N Ambient air temperature CEI 60282-1 : Conditions in normal service Maximum: 40 C Average : 35 C Minimum : - 25 C 19

INFLUENCE OF THE ENVIRONMENT ON THE FUSE CURRENT RATING I N Ambient air temperature θa Kθ A 1 120 θ 80 a 40 1 45 1.03 K θ 1 A 1 50 1.07 55 1.11 60 1.16 65 1.21 I N I B x K θ 70 1.27 20

INFLUENCE OF THE ENVIRONMENT ON THE FUSE CURRENT RATING I N Altitude Altitude (m) Correction factor for rated current 1000 1 1500 0.99 2000 0.98 2500 0.97 3000 0.96 21

PROTECTION OF POWER TRANSFORMERS The short-circuit between lines generates large currents. Fuses interrupt such currents very well within milliseconds, limiting the peak current down to low values. In case of fault inside the transformer, the value of the current increases generally progressively. It can reach high values together with production of gas in many cases. The absence of protection can be catastrophic with a real danger of explosion as the short-circuit is reaching high magnitudes. In this case, the current is limited and well interrupted by the fuses. 22

PROTECTION OF POWER TRANSFORMERS The selection of fuses must be made taking into account: High transient currents occurring in the primary when the transformer power is switched on Overload currents linked to the transformer which are likely to make them prematurely age The use of a fuse in an oil bath requires a particular selection as the various parts of the equipment intervene in the heating process. A downgrading coefficient is to be applied to the rating 23

PROTECTION OF POWER TRANSFORMERS Transformer inrush current I INR 12 I N TRANS à 25 I N TRANS peak I N TRANS t 0.1s 24

PROTECTION OF POWER TRANSFORMERS As a rule of the thumb The fuse current rating I n is at least equal to: I n = 1.7 x I B When considering a 133% overloads: I n = 2.3 x I B I B = transformer rated current Coefficient for temperature must be added: I n = 1.7 x I B x K θ Or I n = 2.3 x I B x K θ 25

PROTECTION OF POWER TRANSFORMERS The table, opposite, may also be used. It has been computed using peak transient currents from 8 to 15 times the transformer current rating and a 130% overload rate. Using this table also means applying the temperature derating factor A1 to the selected rating when ambient exceeds 40 C in the fuse environment. 26

PROTECTION OF POWER TRANSFORMERS Selection from UTE Guide on fuses Network Rated Voltage (kv) EDF Selection Transformer Rated Power Tension Nominale du réseau (kv) C13100 Recommendation Transformer Rated Power 27

RECOMMENDATIONS FOR MOTOR PROTECTION I FLA V AC * 3 P KW * η * cos Φ P KW V AC cos Rated power of the motor (generally in Kilowatt) Rated line to line voltage Efficiency of the motor Power factor The starting current can reach 3 to 8 times the rated current I FLA of the motor 28

RECOMMENDATIONS FOR MOTOR PROTECTION N I F 2000 1.8 x I start T START Average prearc curve of the fuse 10 000 2.2 x I start d 1 100 000 2.85 x I start I START I F 29

RECOMMENDATIONS FOR MOTOR PROTECTION Carrying the motor I FLA and environment conditions As a general rule the fuse rating is at least I N = 1.25 x I FLA 30

RECOMMENDATIONS FOR CAPACITOR PROTECTION The fuse selection must take into: The inrush current occurring when he the capacitor is switched on Harmonic currents during the normal operation of the network The recovery voltage across the fuse terminals after a fault interruption 31

RECOMMENDATIONS FOR CAPACITOR PROTECTION Fuse type selection When a «g» type fuse is used for capacitor protection another protection system is necessary because the fuse rating is generally 2 times the capacitor rated current «a» type fuse can be used providing another protection system interrupt low overloads (minimum breaking capacity of the selected fuse) Selection fo the fuse voltage rating Service voltage may increase up to 20% during overloads U N FUSE > 1.2 times the circuit rated voltage 32

RECOMMENDATIONS FOR CAPACITOR PROTECTION Fuse current rating selection General rule for the continuous load: I N FUSE = 2 x rated capacitor current 33

RECOMMENDATIONS FOR CAPACITOR PROTECTION Withstanding of the capacitor inrush current Average prearc curve of fuse N I F T INRUSH 2000 1.7 x I start 10 000 1.8 x I start 100 000 2 x I start d 1 I INRUSH I F 34