J1000 D E F I 1000 J1000 J1000 J1000 J1000

Similar documents
J1000. Compact Inverter Series.

V1000 DE ES FR IT V1000 V1000 V1000 V1000

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

V1000. Inverter Series.

V1000 Inverter Series

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Description 1/8-7.5HP

YASKAWA AC Drive Compact V/f Control Drive J1000

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

LIFT INVERTER SERIES L1000A

A1000 D E A1000 A1000 A1000 A1000

Varispeed J7 CIMR-J7AZ. System configuration

GS2 Series - Introduction

Experience & Innovation

MX1S Matrix Converter

V1000. AC Drive Series.

Technical Information

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

More freedom - lower cost

SYSDrive Frequency Inverter

LIFT INVERTER SERIES L1000A

DE ES A A. For Modernisation and New Installation L1000A L1000A L1000A

NEW INVERTER SERIES V1000

Delta Products VFD CP2000 Bypass Control Packages.

V1000. YASKAWA AC Drive. Compact Vector Control Drive

A V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

ADJUSTABLE FREQUENCY CRANE CONTROLS

Main Features of Varis

INVERTER SERIES HIGH PERFORMANCE VECTOR CONTROL A1000

YASKAWA AC DRIVES. Yaskawa AC Drives The Global Leader in Quality and Reliability. Certified for ISO9001 and ISO14001

L300P Inverter Specifications

YASKAWA AC DRIVES. Yaskawa AC Drives The Global Leader in Quality and Reliability. Certified for ISO9001 and ISO14001

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

P V Class: ¾ to 175 HP 480V Class: 1 to 1000 HP 600V Class: 2 to 250 HP

VSD Series II Variable Speed Micro Drives

Chapter 1: Getting Started User Manual Overview...1 2

CIMR-V7AZ Varispeed V7

Low voltage AC drives

ABB Component Drives ACS150, 0.5 to 5 Hp

SPRiPM Package Energy-saving Drive Package of Super-Premium-iPM-Motor & Inverter Drive

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Braking unit, Braking resistor unit

SJ300 Inverter Specifications

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

YASKAWA AC Drive V1000. YASKAWA AC Drive V1000

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

LIFT INVERTER SERIES L1000A


Regenerative DC Common Bus Supply

HVAC Products. Introducing the SED2 Variable Frequency Drives

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Technical Explanation for Inverters

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board

BR Second Position Voltages. AA Fourth Position

VFD E Series. Features

L1000A. Lift Inverter Drives.

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

A V Class: ¾ to 175 HP 480V Class: ¾ to 1000 HP 600V Class: 1 to 250 HP

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Braking Unit, Braking Resistor Unit

Frequency Inverters SJ Series Type P1

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & V1000 INVERTER DRIVE

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

ABB component drives ACS150, 0.5 to 5 Hp

USERS MANUAL MCD REMOTE OPERATOR

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

High performance Vector Control. Ratings. System configuration

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

RVS-AX Instruction Manual

SSW07. Soft Starters. Applications. Standard Features

MULTIFUNCTION REGENERATION CONVERTER FR-XC

V1000. YASKAWA AC Drive Compact Vector Control Drive

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

MaxPak Plus Analog DC V S Drive

V1000. YASKAWA AC Drive. Compact Vector Control Drive

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

NEW! Complete IMPULSE Control Panels Available

INVEOR "Smart connections." on five levels

RVS-DN Digital Reduced Voltage Motor Starter

CDBR-D. Instruction Manual. Dynamic Braking Unit. May 2014 Part Number: R1 Copyright 2014 Magnetek

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

HIGH PERFORMANCE VECTOR CONTROL DRIVE

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

ENERGY-SAVING DRIVE PACKAGE SPRiPM MOTOR & INVERTER DRIVE. SPRiPM

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

U1000. Low Harmonics Regenerative Matrix Converter.

Quick Start Guide of CV50- ControlVIT Series

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

RVS-DX Digital Reduced Voltage Motor Starter

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

YASKAWA AC Drive High Performance Vector Control A1000

SOLUTIONS FOR THE TEXTILE INDUSTRY DRIVES AND CONTROLLERS FOR TEXTILE MACHINERY

Transcription:

Compact Inverter SERIES J1000 GB D E F I 1000 J1000 J1000 J1000 J1000

The J-Type YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Page 3 Features & Functions Page 4 Specifications Page 5 Connection Diagram Page 6 Dimensions Page 7 Ratings & Type Descriptions Experience & Innovation For more than 90 years YASKAWA has been manufacturing and supplying mechatronic products for machine building and industrial automation. A leader in Inverter Drives technology Extensive research and development has allowed YASKAWA to remain at the forefront of motion control and automation technology. This technological leadership has helped to modernise industries such as mining, steel, pulp and paper, chemical, automotive, packaging, machine tool and semiconductor. Its standard products as well as tailormade solutions are famous and have a high reputation for outstanding quality and durability. The famous YASKAWA reliability is now available in an even smaller and more powerful unit. J1000 is fully capable of efficient performance and energy saving, handling variable speed needs in compact applications. The J1000 cutting-edge features such as: V/f Control Plug n Play installation function Over-Excitation Braking Easy parameter programming and controller functions Braking Chopper Heavy duty / normal duty rating International standards 2 YASKAWA J1000

Features & Functions Focus on application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its new J1000 compact inverter drive series. Conveyor Pump Grinder The J1000 meets all automation requirements for compact applications with variable speed operation and energy saving characteristics. A wide range of useful functions upgrade your machine and offer great potentials. Hoist Crane Screw Feeder The concept of small size and easy handling with the famous YASKAWA reliability makes the J1000 an alternative in the drive market not only cost wise. Escalator Fan Drilling Yaskawa J1000 Features & Functions Performance compact Design Small design and side-by-side mounting reduce installation space and costs. Stall Prevention Functions Stall prevention ensures stabile operation during momentary power loss, change of load or power supply. International Standards RoHS, CE, cul, UL compliance. High Torque Performance Detects load and automatically adjusts torque regardless the actual speed conditions. Digital Operator 5 digit display, 8 keys on the operator as well as Verify Function for changed parameter values. Options Parameter Copy Unit optional LED Remote Operator Serial Communication Option Compatible with RS-422/485 Interface for MEMOBUS communication. Speed Potentiometer Functions Easy Set-Up Functions Enables quick installation and operation. over-excitation Braking For quick deceleration without external braking resistor. Maintenance monitor informs in advance about recommended maintenance for cooling fan and electrolytic capacitors. Small Design Big Power: 150% overload in heavy duty service is possible. For applications with low overload requirements the drive can be operated with 120% overload in normal duty service. Consequently you can use a drive of smaller size to do the work of a bigger one. tough Operation Power-Loss-Ride- Through and Fault Restart Functions ensure continuous running of the motor. Drive Wizard Plus Free parameter management tool for PC to support installation and operation procedures. 3

Specifications Specifications Control methods Frequency Control Range Frequency Accuracy (Temperature Fluctuation) V/f Control 0.01 to 400 Hz Digital input: within ±0.01% of the max. output frequency ( 10 C to +50 C) Analog input: within ±0.5% of the max. output frequency (25 C ±10 C) Control Characteristics Frequency Setting Resolution Digital input: 0.01 Hz Analog input: 1/1000 of max. frequency Output Frequency Resolution 1/2 20 x Maximum output frequency (E1 04) Frequency Setting Signal Main frequency reference: 0 to +10 Vdc (20 kω), 4 to 20 ma (250 Ω), 0 to 20 ma (250 Ω) Starting Torque 150% / 3 Hz Speed Control Range 1:20 Accel/Decel Time Braking Torque V/f Characteristics Main Control Functions Motor Protection Momentary Overcurrent Protection 0.0 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) q Short-time decel torque* 1 : over 150% for 0.1/0.2 kw motors, over 100% for 0.4/ 0.75 kw motors, over 50% for 1.5 kw motors, and over 20% for 2.2 kw and above motors. w Continuous regen. torque: approx. 20% (approx. 125% with dynamic braking resistor option* 2 : 10% ED, 10 s, internal braking transistor) User-selected programs, V/f preset patterns possible Momentary power loss ride-thru, Speed search, 9-step speed (max), Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Cooling fan on/off switch, Slip compensation, Torque compensation, Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start and stop, Overexcitation braking, Fault restart... Motor overheat protection based on output current Drive stops when output current exceeds 200% of Heavy Duty Rating Protection Function Overload Protection Drive stops after 60 s at 150% of rated output current (Heavy Duty Rating)* 3 Overvoltage Protection Undervoltage Protection Momentary Power Loss Ride-Thru Heatsink Overheat Protection Braking Resistance Overheat Protection 200 V class: Stops when DC bus exceeds approx. 410 V 400 V class: Stops when DC bus exceeds approx. 820 V Stops when DC bus voltage falls below the following levels: 190 V (3-phase 200 V), 160 V (single-phase 200 V), 380 V (3-phase 400 V), 350 V (3-phase 380 V) Stops after approx. 15 ms (default). Protection by thermistor Overheat protection for braking resistor (optional ERF-type, 3% ED) Stall Prevention Separate settings allowed during acceleration and during run. Enable/disable only during deceleration. Ground Fault Protection Protection by electronic circuit * 4 Charge LED Area of Use Charge LED remains lit until DC bus falls below approx. 50 V Indoors Operating Environment Ambient Temperature -10 to +50 C (IP20 open chassis), -10 to +40 C (NEMA Type 1) Humidity 95 RH% or less (no condensation) Storage Temperature -20 to +60 C (short-term temperature during transportation) Altitude Max. 1000 m (output derating of 1% per 100 m above 1000 m, max. 3000 m) Shock 10 to 20 Hz (9.8 m/s 2 ) max., 20 to 55 Hz (5.9 m/s 2 ) max. Safety Standard Protection Design UL508C IP20 open-chassis, NEMA Type 1 enclosure (option) * 1 Momentary average deceleration torque refers to the deceleration torque from 60Hz down to 0 Hz. This may vary depending on the motor. * 2 Parameter L3-04 should be disabled when a Braking Resistor or Braking Resistor Unit is connected. * 3 Overload protection may be triggered at lower levels if output frequency is below 6 Hz. * 4 Protection may not be provided under the following conditions as the motor windings are grounded internally during run: Low resistance to ground from the motor cable or terminal block. Drive already has a short-circuit when the power is turned on. 4 YASKAWA J1000

Connection Diagram Terminals marked -, +1, +2, B1, B2 are for connecting an option. Do not wire AC power lines to these terminals. For 1-phase power supply use R/L1 and S/L2 DC reactor (optional) Link Thermal relay Braking resistor unit *6 (optional) Fuses Power Suppy Filter Main Switch Forward/Stop Reverse/Stop Shielded Cable External Fault Ground Fault Reset Multi-speed 1 +24 V 8 ma Option unit connector DIP switch S1 Multi-function digital inputs (default setting) Fault Multi-function relay output 250 VAC / 30 VDC (10 ma to 1A) (default setting) DIP switch S3 SINK SOURCE Shielded ground terminal Analog input power supply +10.5 VDC, max. 20 ma Analog input 0 to 10 V (20 kω) or 0/4 to 20 ma (250 Ω) Analog output 0 to +10 VDC (2 ma) (Output frequency) Monitor output (default setting) Analog input Symbols: Use twisted pair cables Use shielded twisted pair cables Indicates a main circuit terminal Indicates a control circuit terminal 5

Dimensions Enclosures Standard J1000 uses an open-chassis design (IP20). NEMA 1 kits are available to convert the standard IP20 design to a NEMA Type 1 enclosure rating. Open-Chassis [IP20] Fig. 1 Fig. 2 Voltage Class Three-Phase 200 V Class Single-Phase 200 V Class Three-Phase 400 V class Drive Model CIMR-JA 2A0001B Figure Dimensions in mm W H D W1 H1 H2 D1 D2 t1 2A0002B 68 128 76 56 118 5 6.5 67.5 3 0.6 1 2A0004B 68 128 108 56 118 5 38.5 99.5 5 0.9 Weight (kg) 68 128 76 56 118 5 6.5 67.5 3 0.6 2A0006B 68 128 128 56 118 5 58.5 119.5 5 1.1 2A0008B 108 128 129 96 118 5 58 120.5 5 1.7 2A0010B 108 128 129 96 118 5 58 120.5 5 1.7 2A0012B 2 108 128 137.5 96 118 5 58 129 5 1.7 2A0018B 140 128 143 128 118 5 65 134.5 5 2.4 2A0020B 140 128 143 128 118 5 65 134.5 5 2.4 BA0001B 68 128 76 56 118 5 6.5 67.5 3 0.6 BA0002B 1 68 128 76 56 118 5 6.5 67.5 3 0.6 BA0003B 68 128 118 56 118 5 38.5 109.5 5 1.0 Cooling Self-cooled Fan cooled Self-cooled BA0006B 108 128 137.5 96 118 5 58 129 5 1.7 2 BA0010B 108 128 154 96 118 5 58 145.5 5 1.8 Fan cooled 4A0001B 108 128 81 96 118 5 10 72.5 5 1.0 4A0002B 108 128 99 96 118 5 28 90.5 5 1.2 4A0004B 108 128 137.5 96 118 5 58 129 5 1.7 4A0005B 2 108 128 154 96 118 5 58 145.5 5 1.7 4A0007B 108 128 154 96 118 5 58 145.5 5 1.7 4A0009B 108 128 154 96 118 5 58 145.5 5 1.7 4A0011B 140 128 143 128 118 5 65 134.5 5 2.4 Self-cooled Fan cooled 6 YASKAWA J1000

Ratings & Type Descriptions CIMR- J C B A 0001 B A A Inverter Series Version J1000 J 1st A Specification Coating Specification and Protection Japanese spec. A Standard A Chinese spec. B Moisture (humidity)/dust-proof M European spec. C Oil-proof N USA spec. U Salt-proof C Asia spec. T Vibration-proof S Gas-proof K Moisture/Dust and vibration-proof P Oil and vibration-proof Q Input Voltage Gas-proof + vibration-proof B Single-phase 230 VAC B Oil-proof double coating D Three-phase 200 VAC 2 Moisture double coating E Three-phase 400 VAC 4 Customer Specification Type Standard A Fin Filter Protection level Standard No IP00 A Standard No IP20 without top cover B Standard No IP20 with top cover C Standard No NEMA1(IP20) F Inverter Model Inverter output Inverter input Voltage class Three Phase Inverter CIMR-JCBA 0001 0002 0004 0006 0008 0010 0012 0018 0020 Single Phase* 1 Inverter CIMR-JC2A 0001 0002 0003 0006 0010 Motor output kw at normal duty* 2 0.2 0.4 0.75 1.1 1.5 2.2 3.0 3.7 5.5 Motor output kw at heavy duty * 2 0.1 0.2 0.4 0.75 1.1 1.5 2.2 3.0 3.7 Rated output current at normal duty [A]* 3 1.2 1.9 3.5 (3.3) 6.0 8.0 9.6 12.0 17.5 19.6 Rated output current at heavy duty [A] 0.8* 5 1.6* 5 3* 5 5.0* 5 6.9* 6 8.0* 6 11.0* 6 14.0* 6 17.5* 6 Overload * 1 Drives with a single-phase power supply input have three-phase output. Single-phase motors cannot be used. * 2 The motor capacity (kw) refers to a YASKAWA 4-pole, 60 Hz, 200 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current. * 3 This value assumes a carrier frequency of 2 khz. Increasing the carrier frequency requires a reduction in current. * 4 Rated output capacity is calculated with a rated output voltage of 220 V. * 5 This value assumes a carrier frequency of 10 khz. Increasing the carrier frequency requires a reduction in current. * 6 This value assumes a carrier frequency of 8 khz. Increasing the carrier frequency requires a reduction in current. 200 V 120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current Rated output power* 4 at normal duty [kva]* 3 0.5 0.7 1.3 2.3 3.0 3.7 4.6 6.7 7.5 Rated output power* 4 at heavy duty [kva] 0.3* 5 0.6* 5 1.1* 5 1.9* 5 2.6* 6 3.0* 6 4.2* 6 5.3* 6 6.7* 6 Max. output voltage Three-phase power supply: three-phase 200 to 240 V (relative to input voltage) Single-phase power supply: three-phase 200 to 240 V (relative to input voltage) Max. output frequency 400 Hz Rated input voltage Three-phase 200 to 240 V +10%/-15%, Single-phase 200 to 240 V +10%/-15% Rated input frequency 50/60 Hz, ±5% Inverter Model Inverter output Inverter input Voltage class Three Phase Inverter CIMR-JC4A 0001 0002 0004 0005 0007 0009 0011 Motor output kw at normal duty * 1 0.4 0.75 1.5 2.2 3.0 3.7 5.5 Motor output kw at heavy duty * 1 0.2 0.4 0.75 1.5 2.2 3.0 3.7 rated output current at normal duty* 2 [A] 1.2 2.1 4.1 5.4 6.9 8.8 11.1 rated output current at heavy duty* 3 [A] 1.2 1.8 3.4 4.8 5.5 7.2 9.2 Overload 400 V 120% for 60 sec at normal duty, 150% for 60 sec at heavy duty from inverter rated output current Rated output power* 4 at normal duty* 2 [kva] 0.9 1.6 3.1 4.1 5.3 6.7 8.5 Rated output power* 4 at heavy duty* 3 [kva] 0.9 1.4 2.6 3.7 4.2 5.5 7.0 Max. output voltage Max. output frequency Three-phase 380 to 480 V (proportional to input voltage) 400 Hz Rated input voltage Three-phase 380 to 480 V +10%/-15% Rated input frequency 50/60 Hz +/-5% * 1 The motor capacity (kw) refers to a YASKAWA 4-pole, 60 Hz, 400 V motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current. * 2 This value assumes a carrier frequency of 2 khz. Increasing the carrier frequency requires a reduction in current. * 3 This value assumes a carrier frequency of 8 khz. Increasing the carrier frequency requires a reduction in current. * 4 Value displayed is for when operating at the rated output current. Rated output capacity is calculated with a rated output voltage of 440 V. 7

J YASKAWA Electric Europe GmbH Hauptstr. 185 65760 Eschborn Deutschland / Germany +49 6196 569-300 info@yaskawa.de www.yaskawa.eu.com Specifications are subject to change without notice for ongoing product modifications and improvements. YASKAWA Electric Europe GmbH. All rights reserved. Literature No. YEG_INV_J1000_GB_v2_1108 Printed in Germany November 2008

Wentylatory Nagrzewnice TEL/FAX:(017) 8555744 TEL.KOM: 601478570 Odpylacze KRASNE 830A 36-007 KRASNE Akcesoria Falowniki SklepFalowniki.pl