Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA

Similar documents
Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA

Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA

Residential generator set RS Air-Cooled Series RS20A/AC & RS14AF Model GSBB

Residential standby system RS12000

Residential standby system RS12000

Residential generator set RS Air-cooled series RS20A/AC and RS14AF Model GSBB/GSBC

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

Quiet Connect TM Series - RS13A, RS17A, RS20A, & RS20AC

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

Power Connect TM Series RX60

Spark-ignited generator set

Spark-ignited generator set

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Diesel generator set QSX15 series engine

Residential Standby Generators

Diesel generator set 4BT3.3 series engine

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Diesel generator set QSK23 series engine

Residential Standby Generators

48kW ¹ STANDBY GENERATOR

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Commercial Mobile Generators. Pocket Guide

35kW ¹ STANDBY GENERATOR

Diesel generator set QSX15 series engine

Commercial generator set Hydraulic Series HG 25000

Diesel generator set QSB7 series engine

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

GENERAC GUARDIAN SERIES STANDBY GENERATORS

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Spark-Ignited Generator Set Model GGKC 60 Hz

Diesel generator set 6BT5.9 series engine

Spark-ignited generator set

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Diesel Generator Set Model DFHB 60 Hz

Diesel generator set QSK23 series engine

Rental Power 800 kw. Specification sheet. Description. Features. Options

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

Diesel Generator Set Model DFJD 60 Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Diesel generator set QSL9-G7 series engine

Spark-Ignited Generator Set Model GGKD 60 Hz

Diesel Generator Set S3.8 Series Engine

Spark-Ignited Generator Set Model GGLA 60 Hz

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

Spark-Ignited Generator Set Model GGFD 60 Hz

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

STANDBY GENERATORS 17 kw AIR-COOLED GENERATOR SETS

Siemens Liquid Cooled Standby Generators

Diesel Generator set QSK95 series engine

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

GENERAC GUARDIAN SERIES STANDBY GENERATORS

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Diesel Generator Set Model DFBF 60 Hz

Diesel generator set QSK60 series engine

Model DFEH 60 Hz EPA Emissions

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set QSK50 series engine

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

Diesel Generator Set Model DGDB 60 Hz

Diesel Generator set QSK95 series engine

Diesel Generator Set Model DFCE 60 Hz

1P 120/240V, 3600 RPM,

D RDC2 Controller d One digital controller manages both the generator set and

Diesel generator set QSL9 series engine

Diesel generator set QSK60 series engine

Model DSHAE 60 Hz EPA Emissions

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Model DFHD 60 Hz EPA Emissions

Rental Power QSB7 series engine

Siemens Liquid Cooled Standby Generators

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Model DKAC 60 Hz EPA Emissions

DIESEL GENERATOR SETS

D RDC2 Controller d One digital controller manages both the generator set and

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Transcription:

Specification sheet Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA Features and benefits Very quiet operation Internet remote monitoring and email notification Automatic load management - The intelligent generator control automatically manages non-essential household loads for maximum utilization of generator power Cummins Onan designed alternator and electronic control Powerful motor starting - starts and runs a 4 ton A/C¹ under full pre-load GFCI Ready Self-diagnostic capability Service and maintenance information displayed on in home display Easy installation with innovative molded polymer installation base - no need for a concrete pad Electronic governor for precise frequency control Flexible 12 inch fuel line provided with genset Generator designed and manufactured in the USA U.S. EPA and CARB Emissions Certified UL 2200 Listed and CSA Certified generator and transfer switch for your protection Quality power output, less than 5% THD 5 year, 2000 hour limited warranty Weight, size and sound level Weight: 460 lbs (209 kg) Size: Length 53 in (1346 mm), width 43 in (1092 mm), height 34.7 in (880 mm) Sound: 61 db(a) at 23 ft (7 m) at normal load 2 Models and ratings Series Order model Part Number Fuel Voltage Frequency Rated amps 3 Circuit breaker Cold weather equipped Listing RS13A 13GSBA-6712A A029N006 Natural gas 120/240 60 Hz 92/46 60 A, 2 pole No UL RS13A 13GSBA-6712A and LP A029N006 LP vapor 120/240 60 Hz 106/53 60A, 2 pole No UL Conversion Kit 4 RS13A 13GSBA-6711A A029U736 Natural gas 120/240 60 Hz 92/46 60A, 2 pole Yes UL RS13A 13GSBA-6711A and LP Conversion Kit 4 A029U736 LP vapor 120/240 60 Hz 106/53 60A, 2 pole Yes UL RS13AC 13GSBA-6718A A030S534 Natural gas 120/240 60 Hz 86/43 60A, 2 pole Yes CSA 13GSBA-6718A RS13AC and LP Conversion Kit 4 1 Air-conditioners vary by type, efficiency, operational conditions, etc. Consult with a qualified HVAC specialist or Cummins Onan distributor/dealer for proper sizing. 2 Normal load is defined as typical household consumption of 3kW. 3 Derating guidelines: Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Full rated power available at 60 o F (15.5 o C) and sea level maximum. Derate 3.5% for each 1000 ft (304.8 m) above sea level and 3% for each 10 o F (5.5 o C) increase in ambient temperature above 60 o F (15.5 o C). Maximum wattage or maximum current are based upon minimum service voltage in accordance with UL 2200 (Stationary Engine Generator Assemblies) or CSA C22.2 No. 100-04 (Motors and Generators). 4 To comply with U.S. EPA and CARB emission compliance, LP conversion kit (A030M445) is required to convert 13GSBA 2010 model year and A034F168 to convert 13GSBA 2011 model year generators.

Engine Model: 720 cc, air-cooled v-twin OHV Compression ratio: 8.3:1 Displacement: 40.9 cu in (720 cc) Cooling air volume: 759 cfm Oil sump capacity: 1.80 qt (1.7 L) with filter Operating speed: 3600 rpm Fuel supply pressure: NG 5-11 in H2O, LP 7-11 in H2O Cummins Onan designed fuel system for max power output and durability Integrated oil drain valve and extension tube included Simple fuel conversion between natural gas and LP with LP conversion kit (P/N A030M445) 15 A battery charger Highly reliable solenoid shift starter Transistorized magneto ignition Automotive-style lubrication system Oil cooler Spin-on oil filter Electronic governor Large-capacity air cleaner Weather protective sound enclosure Thick 11 gauge aluminum enclosure with resilient architectural grade powder coat paint Durable polypropylene base eliminates need for concrete pad UL Listed, impact resistant, fully colored, automotive grade polypropylene cover with UV stabilizer All maintenance points are accessible without the use of tools Under the hood oil dipstick check and fill Electrical stub-up and side knockouts provided on genset for installation flexibility Patented, innovative, compact and neighborhood friendly design blends into any residential setting Lift-off enclosure for close proximity installations No exposed fasteners Key lockable High intake and exhaust to reduce rain ingestion and snow blockage GFCI Ready mounting location provided on genset enclosure Externally mounted circuit breaker with weatherproof cover Exhaust muffler Large automotive grade corrosion resistant muffler design Low noise Load management Automatically turns on/off loads to prevent generator overload Easy to set up from in-home display Easily connected at the generator Note: Additional installation and relays are required. Control system Cummins Proprietary electronic control with self diagnostics and generator set protection and safety features included Automatically starts and stops generator upon identification of a power outage Microprocessor control manages generator set operation, fault detection and service diagnostics Illuminated run/off/auto switch Convenient access to all connection points Fully automatic operation Internet/email capability Sends you or your service technician an email if service or maintenance is required. View generator status from the internet. Note: Network Specialist required for set-up Installation and set-up is required. See Installation Manual for additional details. In-home display Wired in-home LCD display is offered standard on every set. Surface mountable at genset (standard) or remotely (installation required). Power continually supplied to the display; no need for replaceable batteries. Genset can be started/stopped from the display. Easily set/adjust genset exercise for day and time, with capability to choose weekly, bi-weekly or monthly. Displays maintenance and service reminders. Percent load is displayed allowing user to manage load. Displays last 30 faults for troubleshooting. Displays last 30 events (i.e., day and time of power outage, exercise, etc.). Adjust and configure RSS service entrance ATS models

Average fuel consumption Fuel consumption natural gas Fuel consumption LP vapor Conversion factor: 8.58 ft³ = 1 lb 0.535m³ = 1 kg 36.39 ft³ = 1 gal Load: 1/4 1/2 3/4 Full Ft 3 /hr: 103 122 172 191 M 3 /hr: 2.9 3.5 4.2 5.4 Kg/hr 2.1 2.5 3.5 3.9 Btu/hr 103000 122000 172000 191000 Nominal fuel rating 37 MJ/M 3 (1000 Btu/ft 3 ) Load: 1/4 1/2 3/4 Full Ft 3 /hr: 42 53 71 88 M 3 /hr: 1.2 1.5 2.0 2.5 Gal/hr 1.2 1.5 2.0 2.4 L/hr 4.5 5.7 7.6 9.1 Kg/hr 2.2 2.8 3.7 4.7 Btu/hr 105000 132500 177500 220000 Nominal fuel rating 93 MJ/M 3 (2500 Btu/ft 3 ) Alternator details Design: Cummins Onan 2-pole, self-excited revolving field. Permanently aligned to engine by a tapered shaft. AC waveform total harmonic distortion: Less than 5% THD (total harmonic distortion). Insulation system and temperature rise: Class H insulation per NEMA MG-1-1-66. Cooling: Direct-drive, centrifugal blower. Rotor: Laminated electrical steel assembly skewed for improved voltage waveform, heavy insulated copper wire windings. Bearing: Double-sealed pre-lubricated ball bearing. DC brushes: Electrographitic, long life, easily serviced. Generator set performance Voltage regulation: ±1.5% no load to full load. Frequency regulation: Isochronous, 0% no load to full load. Motor starting kva (30% voltage dip): 37 Operating temperature: 122 F (50 C) to 32 ºF (0 ºC): Standard Model 122 F (50 C) to -20 ºF (-29 ºC): Cold Weather Equipped Model Additional accessories are available to allow for operation in high humidity. See Accessories section for details. Easy service and installation Removable Lid Air cleaner Plug-n-Play Electrical Connections LP/NG Fuel Connection Polypropylene Mounting Base Oil Check/Fill Oil Drain Valve

Automatic transfer panel configurations Service entrance installation (USA only) (100/200 A) Service entrance installation (USA and Canada) (100/200 A) Dedicated emergency standby service system (100/200 A) (USA and Canada) Basic dimensions Note: This outline drawing (A029Z911) is provided for general reference only and is not intended for use in design or installation. For more information, see Operators and Installation manuals or contact your distributor or dealer for assistance.

UL 1008 Listed: RSS100-6868, RSS200-6869 (0500-4824) CSA/UL RSS100-6634 (0500-4502) CSA/UL RSS200-6635 (0500-4503)

Options and accessories Installation wheel kit (P/N 0541-1624) Additional in-home display (P/N 0300-6576) 2010 model year LP conversion kit (P/N A030M445) 2011 model year LP conversion kit (P/N A034F168) Climate Accessories: Alternator dryer kit (P/N A029J885) humid climates Battery heater kit (P/N 0333-0770) Transfer switch (also sold separately) 100 and 200 amp automatic transfer switch NEMA 3R. Fully automatic operation with Cummins Onan RSS model automatic transfer switch. Reduces installation time with indoor/outdoor flexibility and whole house install. Two amp trickle battery charger included UL 1008 Listed Service Entrance Rated: RSS100-6868, RSS200-6869 CSA Approved and UL 1008 Listed: RSS100-6634, RSS200-6635 Battery requirement 12 V, group 26R, 530 CCA Maintenance Free Warranty policy Plug-n-play installation harnesses The Cummins Onan RS13A and RS13AC generators Generator to ATS harness: 1 ft. length (p/n A029U298) come standard with a 5 year/2,000 hour limited 50 ft. length (p/n A029U302) warranty. Extended warranty options available. See 100 ft. length (p/n A029U303) warranty statement for additional details. 200 ft. length (p/n A029U304) Remote display harness: 1 ft. length (p/n A029U306) 50 ft. length (p/n A029U308) 100 ft. length (p/n A029U310) 200 ft. length (p/n A029U311! WARNING:! WARNING: After sale support Standby rating based on: Applicable Back feed to a utility system can cause Largest distributor/dealer support network for supplying emergency power for the electrocution and/or property damage. Cummins Onan generator sets are supported by the duration of normal power interruption. Do not connect to any building No sustained overload capability is electrical except through an approved largest and best trained worldwide certified available for this rating. (Equivalent to device or after building main breaker is fuel stop power in accordance with open. distributor/dealer network in the industry. This network ISO3046, AS2789, DIN6271 and BS5514.) nominally rated. See T030. of knowledgeable distributor/dealers will help you select and install the right generator set and accessories to meet the requirements of your specific application. This same network offers a complete selection of commonly used generator set maintenance parts, accessories and products plus manuals and specification sheets. Plus, they can answer your questions regarding proper operation, maintenance schedules and more. Manuals: Operation and installation manuals ship with the generator set. To obtain additional copies or other manuals for this model, see your distributor/dealer and request the following manual numbers: Operator (A029V091), Installation (A029V090), Parts (A030A242), Service (A030A240). To easily locate the nearest certified distributor/dealer for Cummins Onan generators in your area, or for more information, contact us at 1-800-344-0039 or visit www.. Contact your distributor/dealer for more information. North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 2012 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. Our energy working for you. is a trademark of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. A-1559b (11/10) cumminspower.com