[You may download this article at: https://fluidsys.org/downloads/ ]

Similar documents
Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Input, Control and Processing elements

Electrohydraulics Basic Level Textbook TP 601

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

Programmable Logic Controller. Mat Nor Mohamad

[You may download this article at: ]

Hydraulic Pumps Classification of Pumps

Ch 4 Motor Control Devices

Pneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008

INTRODUCTION TO SENSORS, TRANSDUCERS & ACTUATORS

: Automation Laboratory 1

The galvanic separation of the primary or actuating circuit and the load circuits

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

PNEUTRAINER-200 Pneumatics - Electro-pneumatics

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Didactic and technological innovation at the service of training in pneumatics and electro-pneumatics have resulted in the creation of the

Electro Pneumatic Workbench Scientech 2470

Learning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Relay. for Experiments with the fischertechnik Expansion Kit. Order No

PNEUTRAINER-400 Pneumatics - Electropneumatics

ELECTRICAL TECHNOLOGY 3 March 2008

Electro Pneumatic WorkStation Scientech 2470

Directional servo-valve of 4-way design

SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

Electrical Control System Components Basics of Magnetic Control :

Kuhnke Technical Data. Contact Details

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

2006 MINI Cooper S GENINFO Starting - Overview - MINI

INTEGRATED ELEMENTS. 1. FLIP-FLOP VALVES (pneumatic) ORDER CODIFICATION : AZ100354

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

For system diagrams and component identification

G. Prede D. Scholz. Electropneumatics. Basic Level

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY

Level 7 Post Graduate Diploma in Engineering Mechatronics

Starting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points

RELAYS. Figure Relay construction.

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

How to Select Automation Accessories for Valves

Solenoid valve. Solenoid Coil

Hashemite University Mechatronics Engineering Department Process Control Laboratory

MOTOR TERMINAL CONNECTIONS

ELECTRO HYDRAULIC & ELECTRO PNEUMATIC

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Outdoor vacuum breaker for railway applications - FSK II

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

MECHATRONICS LAB MANUAL

Basic Machine Interface Options

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Note 8. Electric Actuators

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Lesson 5: Directional Control Valves

Horns, Wiper, and Washer System Operation

Industrial Mechanic (Millwright) Level 3

Actuators and directional control valves

The Discussion of this exercise covers the following points:

Chapter 8 Magnetism and Its Uses. Section 1: Magnetism Section 2: Electricity and Magnetism Section 3: Producing Electric Current

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

PNEUMATIC BASED ASSEMBLY LINE

MONO - MOTRONIC 0309 En

PNEUMATE-200 Your mate in Pneumatics!

Chapter 6 Pneumatic Logic Sensors and Actuators

Modern Industrial Pneumatics. Design and Troubleshooting Industrial Pneumatics PN111 PN121

MERCURY CONTACTORS & RELAYS

Factor 1 Sensors: The Evolutions of Metal Detection A WHITE PAPER

: INDUSTRIAL AUTOMATION & MECHATRONICS COURSE CODE : 6025 COURSE CATEGORY : E PERIODS/WEEK : 5 PERIODS/SEMESTER : 75 CREDITS : 5

PRO series programmer

Directional servo-valve in 4-way design

Industrial Pneumatic Systems Syllabus [Detailed]

PRODUCT INFORMATION BULLETIN

BASIC PNEUMATIC & ELECTROPNEUMATIC TRAINING SYSTEM

MPS Series Proximity Switches

Sorting Line with Detection 24V

Electropneumatics Basic Level Set of Overhead Transparencies TP 201

Components of an Electric Linear Actuator

Syslog Technologies Innovative Thoughts

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

TI23 Pre-Instructional Survey

NHP SAFETY REFERENCE GUIDE

BELT-DRIVEN ALTERNATORS

A SIMPLIFIED METHOD FOR ENERGIZING THE SOLENOID COIL BASED ON ELECTROMAGNETIC RELAYS

DC motor theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

» Principals of Spider -Valve VA series

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

Proportional Pressure Reducing Valve PDM08130

BASIC MECHATRONICS ENGINEERING

MOTOR CONTROLLERS. STATE the function of motor controllers.

VALVE BODY. Shift Pressure Control Solenoid Valve. 1. Leaf spring 2. Contact spring 3. Conductor track 4. O-ring 5. O-ring 6.

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

4.0 OPERATION Type ITH-T Relay

Pneumatic Control System

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Courseware Sample F0

Application Alley. Industrial - Reed Sensor. Detect End Limit Position In Piston And Hydraulic Systems Using Reed Sensors PARTNER SOLVE DELIVER

WHITE PAPER. SVM4001 Series standstill monitor. Stop everything! Standstill monitors add sensorless safety features to motor-driven machinery

Transcription:

Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org [ou may download this article at: https://fluidsys.org/downloads/ ] Relay-based Electro-hydraulic Systems In the electrical actuation of a hydraulic valve, the necessary actuating force is obtained electrically with the help of a solenoid. The off-centre core of the solenoid coil is pulled towards the centre of the coil when the electric current is passed through it. This discrete movement of the core is used to actuate the solenoid valve. The solenoid valve in an electro-hydraulic system acts as an interface between the hydraulic part and the electrical part of the system. 3/2-way Single-solenoid Valve, Spring Return In the normal position of the solenoid valve, the pressure port P remains blocked, and the working port is internally connected to the tank port T. When the rated voltage is applied to the coil, the armature is forced towards the centre of the coil. The movement of the armature shifts the spool away from the valve seat. In the actuated position of the valve, the port P is connected to the port, and the port T remains blocked. When the supply to the coil is cut off, the valve returns to its normal position. This valve can be used as the final control element for controlling a single-acting cylinder. Spool P T rmature T Coil (a) Normal position P T P (b) ctuated position 4/2-way Single-solenoid Valve, Spring Return B Spool B B P T P T P T rmature Coil (a) Normal position (b) ctuated position In the normal position of the solenoid valve, the pressure port P is connected to the working port B, and the working port is connected to the tank port T. The valve is actuated when the rated voltage is applied to the 1

coil. In the actuated position of the valve, the port P is connected to the port, and the port B is connected to the port T. When supply to the coil is cut off, the valve returns to its normal position. This valve can be used as the final control element for controlling a double-acting cylinder. 4/2-way double-solenoid Valve 4/2-way double-solenoid electro-hydraulic valve consists of two solenoid coils on either side of the valve controlling its hydraulic part. The valve remains in a particular position due to the application of a pulse or continuous signal to the coil at one end as long as no opposing signal is presented to the coil at the other end. Hence, this valve shows the memory characteristics. Control Devices number of control elements such as pushbuttons, relays, timers, and sensors are used in electro-hydraulic systems to realise various control functions. Push-button Switch push-button switch is a device used to close or open an electric circuit. This control device consists of a push-button actuating head, a set of fixed and movable contacts, and a restraining spring. Pressing the pushbutton against the restraining spring operates its contacts. 3 4 1 2 1 2 3 4 (a) NO Contact (b) NC Contact The types of contacts distinguished according to their functions are (1) Normally open (NO) type, (2) Normally closed (NC) type, and (3) Change-over (CO) type. In the NO pushbutton, the contacts are open in the normal position, inhibiting the energy flow through the pushbutton. In the actuated position of the NO pushbutton, its contacts are closed, permitting the energy flow through the pushbutton. In an NC pushbutton, the contacts are closed in the normal position, permitting the energy flow through the pushbutton. In the actuated position of the NC pushbutton, its contacts are open, inhibiting the energy flow through the pushbutton. The changeover type contact is a combination of NO and NC contacts. Terminal Markings of Contacts For identification purpose, the terminals of each of the contacts of the control device are designated with a set of numbers based on the function of the contact and the type of control device. Terminal designations Control element types for: NC contact NO contact Ordinary devices (PBs, relays) 1 and 2 3 and 4 Special relays (Timers, counters) 5 and 6 7 and 8 2

Pushbutton Station push-button station consists of a number of contact sets (NO, NC or CO) with a common actuation. pair of successive two-digit numbers is used to designate the terminals of a contact in the pushbutton station. In the two-digit number, the digits in the unit place indicates the function of the contact (that is, whether it is an NO type or an NC type), and the digits in the ten s place merely represent a serial ordering of all contact sets in the pushbutton station for identifying each contact set uniquely. 13 23 31 41 14 24 32 42 Two positions of a self-explanatory electro-hydraulic circuit for the direct control of a double-acting cylinder are given below. ou may take a serious look at the circuit for the proper understanding of the electrohydraulic system. Electromagnetic Relay The relay mainly consists of a coil and a number of independent contact sets. Each contact set consists of a stationary contact and a movable contact. It also includes a stationary core and a movable core to confine the magnetic field. The movable contacts are coupled to the movable core. Therefore, when the coil is energized with the help of an additional electrical circuit, the movable core is pulled towards the stationary core, thus operating all its coupled contacts simultaneously. This movement either makes or breaks the connection of the movable contact with its respective fixed contact in each contact set. 3

Restraining spring Coil Fixed core Movable core Movable contact Fixed contact Indirect control of a double-acting hydraulic cylinder using a relay Two positions of a self-explanatory electro-hydraulic circuit for the indirect control of a double-acting hydraulic cylinder are given below. Logic Controls, Electric Logic controls are used to start or stop various operations in hydraulic systems based on the satisfaction of certain conditions in these systems. Two of the most important logic functions are ND and OR. These functions are used to logically combine signals representing certain conditions in a system. In the ND logic function, the output is produced when all the inputs are present. In the OR logic function, the output is produced when one or more ( 1) inputs are present. Memory Function circuit/device with a memory function remembers its last output state even after the input signal from the input signal responsible for this output has been removed. memory function can be implemented in electrohydraulic circuits by using an electrical latching circuit or by using a double solenoid valve. 4

Latching Circuit, Electric The electrical latching circuit is given in its latched and unlatched positions. It is left to the readers to analyze the circuit for its proper understanding. Sensors Sensors can detect the presence of objects. sensor can work either by the actual physical contact with an object or by the movement of an object in its proximity. ccordingly, the sensors are classified as contact-type sensors (e.g. limit switch) and contactless-type sensors (e.g. proximity sensors). contact-less type sensor uses some physical medium to achieve the sensing function. ny disturbance of the medium produces a signal at the output of the sensor. Limit Switch limit switch is a contact-type sensor comprising a set of switching contacts (NO/NC/CO type), a rolleroperated plunger and return springs. The roller lever is mechanically linked to the contacts. It is usually actuated mechanically by a moving element, such as a cylinder piston, in the associated machine to indicate a particular position of the moving element. The electrical contact is established or interrupted by means of the actuating force acting on the roller lever. The limit switch produces an electrical signal upon detecting the position of the mechanical member to be detected. 5

2 4 1 Reed Switch reed switch consists of two metal strips (reeds) acting as switching contacts. It is hermetically sealed in a glass tube filled with an inert gas to prevent the corrosion of its contacts. This unit is further encapsulated in epoxy resin casing. It is designed to mount on a cylinder. It reacts to the magnetic fields of the permanent magnets provided on the cylinder piston. Reed switch closed Reed switch open + N S (a) Reed switches installed on the cylinder Two-wire Three-wire (b) Symbols of reed switch Proximity Sensors proximity sensor is a contactless-type sensor that detects the presence of an object using a detection system and converts this information into a corresponding electrical signal. One type of detection system uses the eddy currents that are generated in a metallic sensing object by the interaction of the detection system and the object. nother type detects the changes in the electrical capacity of the capacitor in the detection system when an object approaches the sensor. et another type detects objects through a variety of optical properties. ccordingly, there are three basic types of proximity sensors. They are (1) Inductive-type sensors, (2) Capacitive-type sensors, and (3) Optical-type sensors. Inductive Proximity Sensor Inductive proximity sensors are widely used in modern high-speed industrial and process control systems for the detection of metallic objects. n inductive proximity sensor consists of the following blocks (1) an oscillator circuit, (2) a switching circuit, (3) an amplifier, and (4) an output stage, all housed in a resinencapsulated body. part of the oscillator circuit is a coil capable of producing high-frequency magnetic oscillations in the active switching area when the rated voltage is applied to the sensor. If any metallic object is brought near to the active switching area of the sensor, eddy currents are generated in the object. The eddy currents are converted into heat. In fact, this loss draws energy from the oscillator. s a result, the oscillations are weakened. The switching circuit converts this state of the oscillator into a clear signal through the switching stage. Finally, the output signal is amplified and delivered to the load circuit. The sensing range of inductive proximity sensors is usually small, typically up to 12 mm. 6

Object Oscillator Switching-stage mplifier Load 1 2 3 4 ctive switching zone Semi-automatic operation of a double-acting hydraulic cylinder using a sensor The hydraulic part and the electrical part of the circuit for the semi-automatic operation of a double-acting hydraulic cylinder using a proximity sensor (S2) are given below. The circuit is also presented in two critical positions for easy understanding. Figure on the left-hand side gives the position of the electrical part of the circuit when the pushbutton PB1 is pressed and then released. The cylinder extends to its forward position and influences the proximity sensor ( S2 ). The relay coil ( K2 ) connected to the proximity sensor converts the voltage output of the proximity sensor to the corresponding contact operations. normally-closed (NC) contact of the relay K2 is used in the latching circuit for the automatic interruption of the electrical circuit whenever the proximity sensor senses the presence of the cylinder piston. The second part of the figure shows this position of the electrical circuit. The cylinder, then, retracts to its home position automatically. 7

Time-delay Relays (Timers) time-delay relay (or timer) is a control device, used to obtain a specified time delay between the work operations in an industrial system. n electronic timer mainly consists of a coil, control contacts, and an electronic circuit for realizing the required time delay. The delay time can be set on the timer using the potentiometer in the electronic circuit. The contact operation can be delayed either when the coil is energized or when the coil is de-energized. ccordingly, there are two basic types of timers. They are (1) On-delay timer and (2) Off-delay timer. The following sections explain the operations of the on-delay timer. On-delay Timer: n on-delay timer delays the operation of its contacts for, say t seconds, when the coil is energized (ON), but the timer brings back its contacts immediately to their normal positions when the coil is de-energized (OFF). ON OFF High Coil (a) Symbol Contacts Coil input Contact operation Control of a double-acting cylinder using a timer t sec Time Time (b) Timing Diagram Low ctuated Normal ou may test your understanding of electro-hydraulics by analyzing the two critical positions of a selfexplanatory electro-hydraulic circuit with an on-delay timer as given below. 8

uthored by JOJI Parambath, Founder/Director, Fluidsys Training Centre, Bangalore Reference: JOJI PRMBTH, Industrial Hydraulic Systems Theory and Practice, Universal Publishers, Boca Raton, US, 2016. http://www.universal-publishers.com/book.php?method=isbn&book=1627340580 Note: comprehensive account of the topic is given in the textbook on Industrial Hydraulic Systems-Theory and Practice by Joji Parambath. For more useful article and downloads, please visit: https://fluidsys.org/downloads/ Please contact Fluidsys Training Centre, Bangalore for training in the field of Pneumatics, Electro-pneumatics, Hydraulics, Electro-hydraulics, etc. email: info@fluidsys.in website: https://fluidsys.org 9