Metal Particle Detector

Similar documents
Metal Particle Detector

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Pilot Operated 2-Way Gas Valves

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Pneumatic Indicating Relay

2-Way Temperature Sensing Valves

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Intake Air Shut-off Valve

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Thermostatic Control Valve

Thermostatic Control Valves

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Thermostatic Control Valve

Pressure and Temperature Switches

Model E. Thermostatic Control Valves. Typical applications

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

3-Way Temperature Control Valve

Thermostatic Control Valve

3-Way Temperature Control Valve

Optimise your temperature control

3-Way Temperature Control Valve

Is the heart of your engine protected?

Diesel Engine Air Intake Shutoff Valves

System Selection Guide

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Automatic Fuel Shut Down Valves

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Lube Level Maintainer

WARNING! READ BEFORE INSTALLATION

Flameproof Alternators

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Air Intake Shut-off Valve

Solenoid Actuated Diesel Engine Air Shut Down Valves

Diesel Engine Shutdown System

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Oil Mist Detection multi-sensor-system for 2-stroke engines

m WARNING! READ m BEFORE INSTALLATION

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

Diesel Engine Shutdown Valves

Flameproof Alternator

Miniature I/P, E/P Transducer

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

LIMIT SWITCH Axiom - AX

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure.

EG Series Installation Manual

Diesel Engine Shutdown Valve

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Optic Level Switch LO10 Series Owner s Manual

Type MR108 Direct-Operated Backpressure Regulators

Daniel Measurement & Control - Product Training Calendar

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

MVX-Series Diesel Engine Air Shut Down Valves

by AMOT World class diesel engine safety solutions Product Selection Guide

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems

Type Type 1001 Transducers. I/P & E/P Transducers

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

BARTON 7000 Series Liquid Turbine Meters

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

LIMIT SWITCH Axiom - AX

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

LIMIT SWITCH Axiom - AX

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

Product Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION OPERATING PRINCIPLE

Ar-Mite TM Low Flow Armored Flowmeter

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Piston Pumps Series P2 / P3 Variable Displacement

Product Data Sheet DESCRIPTION

LubePro Series Pumps. For Simple, Injector-Based Automatic Lubrication Systems. The Choice of Lubrication Professionals

EMTEC -C PUMPS FOR HIGH PRESSURE COOLANT SUPPLY

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

Char-Lynn Hydraulic Motor. Parts Information. R Series General Purpose Geroler Motor January, 1995

How efficient is your temperature control?

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

COSASCO TWO-INCH SYSTEM

Lube Level Maintainer

Product Data Sheet DESCRIPTION

XTS-W+ Bearing Condition Monitor

Flameproof Alternator

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

P78 Series Controls for Dual Pressure and Hazardous Location Applications

TRITON BTM. Bearing Temperature Monitoring. High measuring accuracy. Engine protection. Very low false alarm probability.

Solenoid Valves Magnetic Level Switches

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Pilot-Operated Safety Relief Valves

Transcription:

Metal Particle Detector Model MPD Stainless steel Overview The Metal Particle Detector switch from AMOT can detect and alert equipment operations of the presence of metal particles in non-conductive fluid lubrication systems (lube oil, transmission fluid etc). Typical applications Developed for use in manual and automatic control systems: MPD - Metal Particle Detector Reciprocating equipment - gas engines - diesel engines - compressors Rotating equipment - gas turbines - steam turbines - transmissions and gear boxes - pumps - compressors Key features and benefits Unique grid sensing technology - detects metal particles and metal chips - detects all conductive metal particles (including non magnetic metal particles) Provides early warning of impending failure - reduced operating costs - corrective maintenance can be scheduled to minimize costly downtime - prevents unnecessary repairs and replacement of expensive parts Approvals UL Class Division 1, Groups A, B, C & D www.amot.com

Metal Particle Detector - MPD Operation Figure 1 - MPD Installation diagram HIGH PRESSURE OIL INLET BLOCK VALVE ORIFICE* MPD FILTER RECIPROCATING OR ROTATING EQUIPMENT EXIT BLOCK VALVE Operation is simple and straight forward. Process fluid, such as lube oil or transmission fluid, enters at the top of the MPD s body. Fluid then travels through a perforated board containing a plated electrical grid on the board s top and bottom sides. Fluid exits through the bottom of the MPD body (refer to Figure 1). PUMP BLEED VALVE SUMP * Flow to the MPD should be limited to prevent starving the equipment of Figure 2 - MPD Switch diagram Activation of the MPD switch occurs when metal particles bridge the gaps on its electrical grid and complete a normally open (N.O.) electrical circuit to drive an alarm or shutdown relay (refer to Figure 2). CIRCUIT OPEN (NO PARTICLES ON GRID) CIRCUIT CLOSED (PARTICLES ON GRID Metal particles gather on the MPD s grid to complete an electrical circuit. Refer to right diagram. page 2

Design considerations Metal Particle Detector - MPD The following considerations should be noted when installing the metal particle detctor: Locating where the MPD will be mounted The MPD must be located in a side stream of the lube oil/fluid system, after the pump but before the filter. Mounting the MPD Mount the MPD with the grid in horizontal position. Piping the process fluid to the MPD Do not permit debris to enter the MPD while piping (this may close the MPD grid circuit). Making MPD electrical connections All wiring to and from the MPD should be done in accordance with the applicable electrical code. Hazardous area requirements Hazardous area rating requires that a safety barrier is installed. The following must also be complied with: Figure 3 - MPD Hazardous area diagram 1. Selected safety barriers shall be listed or approved with intrinsically safe circuits for class I, groups A, B, C, & D. 2. Output current of the barrier must be limited by a resistor such that the output voltage-current plot is a straight line drawn between open circuit voltage and short circuit current. 3. Intrinsically safe wiring must be installed in accordance with the national electrical code, ANSI/NFPA 70, Article 50 and the Canadian electrical code where applicable. 4. Safety barrier must meet the following parameters: Voc Vmax=28 Isc Imax=100mA Ca Ci+Ccable La Li+Lcable 5. If the electrical parameters of the cable are unknown, the following values must be used to calculate: Ccable and Lcable Capacitance=60pF/ft Inductance=0.2μH/ft Example: 1000ft of cable would equal: Ccable = 1000ft x 60pF/ft = 0.6μF Lcable = 1000ft x 0.2μH/ft = 0.2μH 6. The metal particle detector entity parameters for class I, groups A,B,C & D hazardous locations are: Vmax = 28V Ci=0 Imax=100mA Li=0 page 3

Metal Particle Detector - MPD Specification Body & end caps: Seals: Electrical connections: Oil port connections: Electrical connection: Grid electrical ratings: 316 stainless steel Viton (Buna N optional) Plated tin 1 /2 NPT 3 /4 NPT 3.5 va. 24 volts (AC or DC) Maximum recommended for operator safety. Intrinsically safe power supplies may also be used. Temperature rating: -23 to 177 C (Viton) (-10 to 350 F) (Viton) -48 to 121 C (Buna) (-54 to 250 F) (Buna N) Max. working pressure: 13.8 bar (200 psi) Recommended wire gauge: 1.5mm² (16 gauge) Lead wire gauge: 1.5mm² (16 gauge) Flow coefficient: Kv = 3.78 (Cv = 4.39) Grid specification: Hole size 0.8mm (1/32 ) Grid space distance 1.6mm (1/16 ) Approvals: UL Class, Division 1, Groups A, B, C & D How to order Use the tables below to select the unique specification of your MPD Metal Particle Detector or specify the following information: Example MPD2R T 5 P 2 -AA Code Description Model and design level MPD2R Basic Stainless Steel Model Port Connection T 1/2" NPT Oil Port Connection W 1/2" SAE U 1/2" BSP (PL) Connection Tube 5 3/4 NPT Electrical Connection Type P Terminal plug T Terminal block Electrical Connection Type W Wire leads 18" D DIN Connector C/W Earth Wire Seal Material 1 Buna N (Nitrile) Seal material 2 Viton Special requirements -AA Standard Special requirements -** Special requirements page 4

OIL UNDER PRESSURE Metal Particle Detector - MPD Dimensions 160.3 160.3 (6.312) 84.1mm (3.312) 34.9 34.9 (1.375) 34.9 34.9 (1.375) AMOT CONTROLS Metal Particle Metal Particle MPD Detector Detector 63.5 63.5 (2.500) DIA dia DISTANCE FOR GRID REMOVAL 57 (2.250) 57.2 MIN MIN PRIMARY 0-RING SEAL VENT OIL SUPPLY CONNECTIONS 1/2" -14 NPT 20.6 (0.812) 20.6 41.3 41.3 (1.625) CONDUIT CONNECTION 3/4" -14 NPT MOUNTING THREADS 5/16" -18 UNC-28 X 0.625 FULL THREAD 39.7 39.7 (1.562) 31.8 31.8 (1.250) 79.4 79.4 (3.125) ISO LATE AND D R A CAUTION O VING COV E R IN BEFORE REM 41.3 41.3 (1.625) DIA 46 (1.812) 46 2x 231.8 x 31.8 DIA (1.125) dia Dimensions in mm (inches) 0.520" SQUARE HOLE USE 1/2" RATCHET DRIVE TO REMOVE COVERS Service kits Recommended spares/service parts 2 Stainless steel version - Kit Part no: 10829X001 Ref. No. Qty. Description 2 1 Grid 20 9 2 1 End Cap O-Ring (Viton) Grid O-Ring Seal (Viton) page 5

Europe, Middle East and Africa AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ United Kingdom Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com Asia and Australasia AMOT Shanghai Bd. 7A, No. 568, Longpan Rd. Malu Jiading Shanghai 201801 China Tel +86 (0) 21 6279 7700 Fax +86 (0) 21 5237 8560 Email shanghai@amot.com AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany Tel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email germany@amot.com Americas AMOT USA 8824 Fallbrook Dr Houston, TX 77064 USA Tel +1 (281) 940 1800 Fax +1 (713) 559 9419 Email general: sales@amotusa.com orders: orders@amotusa.com customer service: cs@amotusa.com www.amot.com