Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

Similar documents
GMT Fuse Panel Installation Guide

TPM/GMT Panel Installation Guide

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

PowerWorx DSX Series GMT Fuse Panel User Manual

Installing Power Components

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Demarcation Fuse Alarm Panel

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Dual-Feed 600A Load Center Frame

100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

NTK599BAE5 and NTK599BGE5 Breaker Interface Panel (BIP) Installation Manual

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

HMW Filtered Fuse Panel for GMT Fuses

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Electrobar FS Conductor Bar System

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

User Manual. Solar Charge Controller 3KW

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

Dry Contact Closure Interface

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

ACE Variable Frequency Drive System

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

ANZI Transfer Switch and Generator Wiring Installation Addendum

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Installation and Operations Manual

Quik-Spec Coordination Panelboard Specifications


TI23 Pre-Instructional Survey

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

:: :: TFD4 :: TFD6

INSTRUCTIONS. Power Panel. Installation Instructions

SWX-100-INT-PCR Internal Isolation Switch

Sunwize Power Ready Express Quick Start

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

K25000 & KD25000 Series

Photovoltaic Solar Plan Review

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

CHAPTER 10 ELECTRICAL. Notes:

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Pretest Module 24 Three-phase Service Entrance

CV41. Vehicle Mounting Kit. Reference Guide

ROAD TECH ZUMO GLOBAL POSITIONING SYSTEM (GPS) HANDLE- BAR MOUNT KIT

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

User Manual Solar Charge Controller 3KW

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

ACE Variable Frequency Drive System

Product Manual & Installation Guide Vertical Rack Mount 5.0 to 8.6 kw

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

Custom Dynamics Spyder Stingerz Installation Instructions

TC26-B Vehicle Sensor

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Installing the Air Flow Regulator

SAVE THESE INSTRUCTIONS

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

SAVE THESE INSTRUCTIONS

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

8300 Series Installation Guidelines

MASTERsine Inverter PXA Series Installation Guide

XLM 62V Energy Storage Module

USER MANUAL. Maxwell Technologies BOOSTCAP 56V UPS Energy Storage Modules. Models: BMOD0130 P056 B02 BMOD0130 P056 B03. Document Number

XLR Energy Storage Module

Secondary DC Distribution E R P R P I 2. Technical Reference Guide

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

nrgsmart Power Distribution Remote Monitoring

Quick Connection Panel (QCP) Installation Guide

High Frequency SineWave Guardian TM

RU SERIES UPGRADE TempAssure Compatible

Connecting to DC Power

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

ME 463 Electronics Design

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

Installing the ONS M6 Shelf

ELECTRICAL SAFETY. Safety Training For The Non-Qualified

Manual Transfer Switch

Sunwize Water Pumping Kit Quick Start

Transcription:

Total Front Access Wall Mount Fuse Panel Installation Guide Document INS-7473121031 This manual covers the following part numbers- 7473121031

Table of Contents Section 1- General Information... 3 1.1 - Product Description... 3 1.2 - Inspection... 3 1.3 - What s Included... 3 Section 2 Before You Begin... 3 2.1 - Tools Required For Installation... 3 2.2 - Input Bus Amperage Rating (GMT Panel)... 4 2.3 - Fuse Sizing Information... 4 2.4 - Fuse Replacement Information... 4 2.5 - Wiring Temperature Information... 4 2.6 - General Notes on Terminal Connections... 4 2.7 - Terminal Information... 4 Section 3 Wall Mounting... 4 3.1 - Wall Mounting... 4 3.2 - Additional Wall Mounting Instructions... 4 Section 4 Input and Grounding Cabling... 5 4.1 - Chassis Grounding (Earthing)... 5 4.2 - Input Wiring... 5 4.3 - Power Verification Test... 5 Section 5 Output and Alarm Cabling... 5 5.1 - Output Wiring... 5 5.2 - Alarm Wiring... 5 Section 6 Final Installation... 5 6.1 - Fuse Installation... 5 6.2 - Energizing the Panel... 5 Section 7 Accessories... 6 Section 8 - Revision Record... 6 Copyright Trimm, Inc. All Rights Reserved - 2 -

1.1 - Product Description Section 1- General Information Trimm, Inc. s Total Front Access Wall Mount Power Distribution Panel is designed for wall mount applications where rack space is not available. The total front access design places all input/output connections and fuses on the front of the panel. This panel offers 10 GMT type fuse positions of from.18 to 15 Amps per position. Alarm status is displayed locally via the integrated fuse indicator with relay contacts for remote fuse fail indication. This product is suitable for central office locations, network telecommunication facilities, data centers, and outside plant enclosures. These fuse panels may be installed in GR-3108 Class 3 environments 1. 1 Salt fog exposure requirements were not evaluated with these products. 1.2 - Inspection Inspect the panel for any noticeable defects, missing parts (See What s Included below), or shipping damage. Please notify Trimm, Inc. if any problems are found at 1-800-298-7466. No products may be returned to Trimm, Inc. without the proper Return Material Authorization (RMA) number. 1.3 - What s Included This unit should be packaged with the following items. Please notify Trimm, Inc. if any of these items are not included so a replacement can be sent out right away. Front access fuse panel (verify part number from sticker on rear of unit.) Installation instruction packet Section 2 Before You Begin This panel should be installed in a restricted access area by qualified service personnel only. All connections/methods should meet all national/local electrical codes as well as company specific methods or procedures. Failure to do so may result in damage to the equipment, and or personal injury. A readily accessible disconnect device must be incorporated into the supply wiring for this product. This disconnect device must be capable of interrupting the maximum available fault current determined by analysis for your system. 2.1 - Tools Required For Installation The following tools are needed to install this product. Multimeter Torque wrench with 7/16 socket Small slotted torque screw driver (1/8 wide max) Suitable crimp tooling for the input terminals Cable ties or lacing cord Wire cutter/stripper Fasteners for wall mounting (not included with panel) Copyright Trimm, Inc. All Rights Reserved - 3 -

2.2 - Input Bus Amperage Rating (GMT Panel) This product was designed to be used at its input bus amperage rating of 100 Amps, fed by a 2 AWG wire and protected by a 125 Amp over current device. 2.3 - Fuse Sizing Information The fuse manufacturer recommends that GMT fuses rated 8 to 15 Amps be continuously operated at no more than 70% of their current rating. All other fuse types/amperages shall be continuously operated at no more than 80% of their current rating. 2.4 - Fuse Replacement Information The correct fuses may be ordered from the table at the end of this document. See section 7. 2.5 - Wiring Temperature Information The wiring for this product should be rated 90 C or better. Wiring protected by GMT fuses shall be at least one size larger than the minimum required wire based on the National Electric Code, NFPA 70 ampacity tables. 2.6 - General Notes on Terminal Connections Bare conductors should be coated with appropriate antioxidant compound before crimp connections are made. Use appropriate shrink tubing over un-insulated terminal barrels. Ensure that the mating surface of both the terminals and their connection point are clean and free of paint. Appropriate antioxidant should be applied to the mating surfaces of all connections. Use only listed terminals and crimp tooling when making connections. 2.7 - Terminal Information The following terminals or suitable equivalents may be used for connection to this product. This recommendation is based on the panel s bus amperage rating. 7473111031 Suggested Field Wiring Terminals (Code wire) Connection Manufacturer Manf. Part Number Wire Gauge Stud Size Hole Spacing Max. Width Input (GMT fuse type) Panduit LCD2-14A 2 AWG 1/4" 5/8".625" Output (GMT fuse type) Remote Alarm Set Screw (Non required) Set Screw (Non required) The above list is only a suggestion. Equivalent terminals may be used provided they are listed and crimped with the appropriately listed crimp tooling. Section 3 Wall Mounting 3.1 - Wall Mounting Secure the panel to the desired mounting surface using the 4 holes provided in the mounting bracket. The mounting bracket can be placed in multiple positions depending on your mounting requirements. 3.2 - Additional Wall Mounting Instructions If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the unit s maximum operating temperature. Mounting of the equipment should be such that a hazardous condition is not achieved due to uneven mechanical loading. Copyright Trimm, Inc. All Rights Reserved - 4 -

Section 4 Input and Grounding Cabling Before installation, verify that the input power disconnect device is turned OFF 4.1 - Chassis Grounding (Earthing) This product is suitable for use in either a Common or Isolated (CBN or IBN) Bonding Network. This panel was designed to be grounded through the unit s enclosure and mounting hardware. Ensure that this unit suitably grounded. Reliable Earthing of rack-mounted equipment should be maintained. (First On, Last Off). 4.2 - Input Wiring Remove the input covers and locate the #1/4-20 locking nuts supplied with this panel. Crimp the battery and return wires to the proper terminals. Attach the wires to the panel using the supplied locking nuts. Torque the fasteners to 24 in-lbs. 4.3 - Power Verification Test This test is to verify proper function of the panel prior to the connection of loads. Turn on the over current protection/disconnect device supplying power to the fuse panel. Use a multi meter to verify that voltage and polarity are correct at the input connection. Verify that continuity is present between C and NC power alarm contacts. Install a failed fuse if possible and verify that continuity is present between C and NO fuse alarm contacts. Section 5 Output and Alarm Cabling Before continuing installation, verify that the overcurrent protection/disconnect device is turned OFF 5.1 - Output Wiring This panel accepts up to #12 AWG wire to feed into the equipment and return connections. Strip the wires approximately.260 (6.5mm). Loosen the screws for each position. Insert the wire into the corresponding position for both equipment and return connections. Torque the screw to 5 in-lbs. (.5 Nm). 5.2 - Alarm Wiring The alarm connector accepts #12-22 AWG stranded/solid wire. Strip end of wire to.260 (6.5mm), insert into the corresponding positions of the alarm connector. Torque the screw to 5 in-lbs. (.5 Nm). Continuity is established at positions C and NC when there is no fuse failure. Continuity is established at positions C and NO when a fuse failure has occurred. Section 6 Final Installation 6.1 - Fuse Installation Orientate and install the correct fuse into its position. 6.2 - Energizing the Panel Once all steps have been completed above, and a final inspection of the installation has been completed, you may energize the fuse panel by switching the corresponding interrupt device to its ON position. Copyright Trimm, Inc. All Rights Reserved - 5 -

Section 7 Accessories GMT FUSES PART NUMBER FUSE AMPERAGE 0300097000 18/100 AMP 0300097001 1/4 AMP 0300097016 3/8 AMP 0300097002 1/2 AMP 0600097065 65/100 AMP 0300097003 3/4 AMP 0300097004 1 AMP 0300097005 1-1/3 AMP 0300097006 1-1/2 AMP 0300097007 2 AMP 0300097008 3 AMP 0300097013 3-1/2 AMP 0300097012 4 AMP 0300097009 5 AMP 0300097011 7-1/2 AMP 0300097010 10 AMP 0300097014 12 AMP 0300097015 15 AMP 0300097100 DUMMY FUSE 0300097209 GMT/X FUSE COVER Section 8 - Revision Record Legend: Type R=Revision A=Addition D=Deletion T=Typo N=New V=Review Revision Date Type Section/Comments A 04/08/09 N New Document B 01/18/11 R Added GR-3108 language, updated grounding language. Copyright Trimm, Inc. All Rights Reserved - 6 -