IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

Similar documents
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Model 8144NC Fresh Air Ventilator

TOTALINE MECHANICAL FILTERS

Safety & Installation Instructions

Air Curtain. Installation, Operating and Maintenance Instructions

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only.

FlowAir CATALOG.

INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Owner s Manual Phoenix GuardianR

Solutions from SPTT-3

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Owner s Manual Phoenix Mini-Guardian HEPA System

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

INSTALLATION / OPERATION / MAINTENANCE GUIDE

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

FlowCon Fabric Air Diffusers

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

Fume extractor is warranted for two years, parts and labor.

ELITE SERIES R-410A Ready - Multi-Position

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

QUICK GUIDE. Table of Contents. Headlight Installation Guide - English P. 03

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro

PHOENIX MINI-GUARDIAN

Complete HVAC Capability

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

Kitchen Tech Series Air Curtain

Further information: Berriman Associates Model 850P.2 Owners Manual

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

AD-1251 Probe with Differential Pressure Transducer

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

Rear Upper Camber Link (12425) Scion tc

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Thermaltake Warranty / Support Information

G8MVL. Product Specifications

SLIMZONE CLASSIC /

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

UV-AIRE AIR PURIFYING SYSTEM

RVF4109CH. Features. Dimensions RUVATI. Model: RVF4109CH Single Handle Bathroom Faucet

Products for Indoor Air Quality and Control

Aplos Single Lever Basin Faucet

Installation Instructions & Warranty

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

FAN POWERED HEPA FILTER UNIT

SDL Single-Duct, Low-Height, VAV Terminals

4007 (Coupe) / 4008 (Convertible) Subframe Connectors Camaro/Firebird

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

HRM. Heat Pipe Energy Recovery Modules. Installation, Operation & Maintenance

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Air Purifiers Product Guide

Single Lever Pull-Out Kitchen Faucet

EGG CRATE RETURN GRILLE

Installation Instructions Model: AB Single-Lever Pull-out Kitchen Faucet

Pneumatic High-Viscosity Filtration System Instruction Manual

Sanitary Yard Hydrant Installation Instructions

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

Ceiling swirl diffusers with perforated face plate

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

PRICED BILL OF QUANTITIES Package : Air conditionning. Manhours (h) Unit (tariff) Discount Total Unit. Total. Material cost

Installation Instructions & Warranty

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Installation Instructions & Warranty

SUPERIOR PERFORMANCE

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

FOR GAGE UNIT INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation & Service Manual for Horizontal Cartridge Filtration Systems

Uplift Premium Power Lifting Seat

Cooling Capacity CFM in. w.c. (125 Pa)

Requires Ductwork and Blower

Transcription:

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System Perfect 16 Installation Manual

Product Data High-Performance Medical-Grade Residential/Commercial Air Filtration System Application The Perfect 16 ID Series is a V-bank filter system that connects to the return air duct or supply air duct of a forced air system. This Residential / Commercial Air Filtration System has been designed to provide the highest possible air cleaning rate at the lowest possible pressure drop for residential and commercial forced air systems. Two models are available. The ID-2225 is ideal for airflow rates up to 1200 cfm (2040 m 3 /h) and the ID-2530 for airflow rates up to 2000 cfm (3400 m 3 /h). Features Ultra efficient: MERV16 certified (ASHRAE 52.2) Low air resistance: 0.22 w.c. ( 54 Pa) at rated airflow Long filter life: 3 years in average home use Quick and easy filter replacement: No tools needed Easy installation: Requires no electrical connections Rugged steel cabinet: Supports weight of furnace Medical grade finish: Powder coated galvanized steel Fully insulated for installation in unconditioned environments Swiss made quality: 10 year warranty ID-2225: Provide 24 1/2 (622) service clearance in front of unit. ID-2530: Provide 28 1/2 (721) service clearance in front of unit. System All measurements in inch (mm) H L W Page 2

Performance Data Filter Usage Usage vs. Resistance Average home based on 50% duty cycle ID-2225 at 1200 cfm ID-2530 at 2000 cfm in H2O Pa in H2O Pa new 0.18 44 0.22 54 3 months 0.18 45 0.22 55 6 months 0.19 47 0.23 57 9 months 0.20 50 0.24 60 12 months 0.21 53 0.26 64 15 months 0.22 56 0.28 70 18 months 0.24 59 0.31 78 21 months 0.25 62 0.35 87 24 months 0.26 66 0.39 97 27 months 0.28 71 0.44 110 30 months 0.31 77 0.50 125 33 months 0.34 85 0.57 142 36 months 0.38 94 0.64 161 Minimum Efficiency Reporting Data Minimum Efficiency Reporting Value (MERV) ID-2225 MERV 16@492 fpm (2.5m/s) ID-2530 MERV 16@492 fpm (2.5 m/s) Rated airflow 1400 cfm (2380 m 3 /h) 2000 cfm (3400 m 3 /h) Composite Average Efficiency E1 (0.3 1.0 µm) = 96.7% E2 (1.0 3.0 µm) = 97.7% E3 (3.0 10.0 µm) = 98.5% E1 (0.3 1.0 µm) = 95.9% E2 (1.0 3.0 µm) = 97.3% E3 (3.0 10.0 µm) = 98.3% Media area 170 sq.ft. (15.8 m 2 /h) 210 sq.ft. (19.5 m 2 /h) Airflow vs. Filter System Resistance ID-2225 ID-2530 cfm (m 3 /h) in H2O Pa in H2O Pa 600 (1020) 0.06 14 0.03 8 800 (1360) 0.09 21 0.04 12 1200 (2040) 0.18 44 0.10 24 1600 (2720) 0.33 82 0.15 38 ID-2225 ID-2530 2000 (3400) 0.49 122 0.22 54 Based on ASHRAE 52.2 Air Cleaner Performance Reports from Intertek Testing Services (ETL SEMKO), Cortland, NY Page 3

Residential Installation ID-2225 System ID-2530 System Dimension L x W x H inch mm 25.25 x 21.25 x 21.25 642 x 540 x 540 29.25 x 25.25 x 21.25 743 x 642 x 540 Weight 59 lbs. (27 kg) 74 lbs. (33.5 kg) Order No. 207 80 21 02 207 80 21 04 ID-2225 Replacement Filter Set ID-2530 Replacement Filter Set SIZE 3 SIZE 4 Order No. 202 11 30 02 (Filter Set, 4 count) 202 11 30 03 (Filter Set, 4 count) Residential Installation The Perfect 16 ID-Series can be suspended from exposed ceiling joists or the ceiling surface. Alternatively, it can be floormounted (see page 5 for installation options). 1. Choose a location between the main return duct and the furnace, which is readily accessible for checking and replacing the filter. Allow at least 24.5 in. (622 mm) clearance in front of the ID-2225 and 28.5 in. (724 mm) clearance in front of the ID-2530. 2. Adapt connection panel for duct air handler connection as necessary (see page 4). Best performance is achieved with the 16 x 20 opening for the ID-2225 model, and the 20 x 25 opening for the ID-2530. If flex duct is used, it is strongly recommended to use 18 round dove tail collar for the ID-2225 and 20 for the ID-2530 for best performance. 3. Determine the correct air inlet and air outlet side of the system. The air inlet is marked with Cut this Panel for Duct Connection - DIRTY AIR IN. The air outlet is marked with Cut this Panel for Duct Connection - CLEAN AIR OUT. Both panels will need to be cut for the proper fit of the ducting prior to installation. 4. If the Perfect 16 system is to be located immediately alongside the furnace, remove filters and secure cabinet via panel from inside to the furnace with sheet metal screws. Ensure correct airflow direction when reinserting filters. 5. In basement installations, sheet metal turning vanes may be necessary to improve air movement through an elbow in the duct. 6. Use foil tape to seal all duct joints. Note: All leaks on the return side of the system will cause dirty air to leak into the return air stream. Leakage also occurs in many furnaces via the blower door. The blower door should also be sealed with foil tape for the best air cleaning results. 7. Fill out the filter replacement label with the date of the next scheduled filter replacement, which should be no later than 3 years from the current date (based on 50% usage). 8. Check and inspect system for leakage. 9. Test for efficiency with a ParticleScan. Page 4

Residential Installation Examples Up-Flow Furnace Filter system is installed vertically and return air enters the furnace side inlet (up to 4 ton application). Up-Flow Furnace (5 ton application) Filter system is installed vertically and return air enters the furnace side inlet (5 ton application). Up-Flow Furnace Filter system is installed horizontally beneath the furnace. Return air enters from the bottom. Down-Flow Furnace Filter system is installed horizontally in the return air duct just above the furnace. Horizontal Furnace Filter system is installed vertically in the return air duct near the furnace. Page 5

Commercial Installation ID-2225 System ID-2530 System Dimension L x W x H inch mm 25.25 x 21.25 x 21.25 642 x 540 x 540 29.25 x 25.25 x 21.25 743 x 642 x 540 Weight 59 lbs. (27 kg) 74 lbs. (33.5 kg) Order No. 207 80 21 02 207 80 21 04 ID-2225 Replacement Filter Set ID-2530 Replacement Filter Set SIZE 3 SIZE 4 Order No. 202 11 30 02 (Filter Set, 4 count) 202 11 30 03 (Filter Set, 4 count) Commerciall Installation The Perfect 16 ID-Series can be suspended from exposed ceiling joists or the ceiling surface. Alternatively, it can be floormounted. 1. Choose a location between the air handler and the supply registers, which is readily accessible for checking and replacing the filter. Allow at least 24.5 in. (622 mm) clearance in front of the ID-2225 and 28.5 in. (724 mm) clearance in front of the ID-2530. 2. Adapt connection panel for duct air handler connection as necessary (see page 4). Best performance is achieved with the 16 x 20 opening for the ID-2225 model, and the 20 x 25 opening for the ID-2530. If flex duct is used, it is strongly recommended to use 18 round dove tail collar for the ID-2225 and 20 for the ID-2530 for best performance. 3. Determine the correct air inlet and air outlet side of the system. The air inlet is marked with Cut this Panel for Duct Connection DIRTY AIR IN. The air outlet is marked with Cut this Panel for Duct Connection CLEAN AIR OUT. Both panels will need to be cut for the proper fit of the ducting prior to installation. 4. If the Perfect 16 system is to be located immediately alongside the air handler, remove filters and secure cabinet via panel from inside to the furnace with sheet metal screws. Ensure correct airflow direction when reinserting filters. 5. In basement installations, sheet metal turning vanes may be necessary to improve air movement through an elbow in the duct. 6. Use foil tape to seal all duct joints. Note: All leaks on the return side of the system will cause dirty air to leak into the return air stream. Leakage also occurs in many air handlers via the blower door. The blower door should also be sealed with foil tape for the best air cleaning results. 7. Fill out the filter replacement label with the date of the next scheduled filter replacement, which should be no later than 3 years from the current date (based on 50% usage). 8. Check and inspect system for leakage. 9. Test for efficiency with a ParticleScan. Page 6

Commercial Installation Examples Supply Duct The Perfect 16 can be installed on supply ducts, provided the airflow of the duct is 2000 cfm or less. Balance volume dampers and/or registers as necessary. Supply Duct Branch The Perfect 16 can be installed on supply duct branches, provided the airflow to the branch is 2000 cfm or less. Balance volume dampers and/or registers as necessary. dirty air in clean air out Before Supply Plenum In installations of 2000 cfm (5 tons) or less, the Perfect 16 can be installed before the Supply Plenum. Note: The Perfect 16 is designed to sustain a maximum of 149 F (65 C). Page 7

Cutting Openings into Panels 1. Remove the panel with sticker please cut here for duct connection from the Perfect 16 system. Detach the insulation from the panel. 2. Adjust the cutting tool to the right position and fix it in the center hole of the panel for any round opening. 3. Cut the panel and remove the inner part. 4. Put the insulation under the panel and cut it around the opening. 5. Remove the insulation again. 6. Install the dove tail collar on the panel by folding some teeth to the outer side for fixing the collar on the panel. 7. Turn the panel around and fix the collar by folding the rest of the teeth. 8. Screw the collar tightly on the front side by fixing the teeth with metal screws. Page 8

Cutting Openings into Panels 9. Seal the gap between the collar and the panel and wait till it has dried. 10. Put the insulation to the inner side of the panel and fix the insulation to the collar with a duct tape. 11. Stick the tape tightly to the insulation. 12. Attach the connection panel again to the Perfect 16 system. Page 9

Installing the Perfect 16 1. When positioning the unit, ensure that Dirty Air In is your air inlet. For duct connection, follow local installation codes. 2a. To attach the Perfect 16 directly to a furnace, take out all filters and use sheet metal screws to tap through square connection panel. 2b. Side connection as pictured can be used for up to 4 ton applications. For 5 ton applications use return base. 3. Ensure that there is unobstructed access to the filter replacement door. Ensure 24 1 2 in. (622 mm) front clearance for unit ID-2225 and 28 1 2 in. (724 mm) for ID-2530. 4. To hang or suspend the Perfect 16, replace four TX30 screws with four Perfect 16 eye bolts. These are available for a nominal fee. Page 10

Filter Replacement 1. Access to replace filters is gained from the side panel with the finger screws attached to it. 2. Remove all eight finger screws. 3. Remove access panel. 4. Remove filters starting from the top. 5. Insert new filters starting from the bottom. 6. Ensure that you align the filters with the airflow arrows matching the airflow arrows on the cabinet. AIRFLOW AIRFLOW 7. Double check that all filters have been inserted correctly and replace access panel with screws. 8. Fill out filter replacement label with scheduled date of next filter replacement. This should be no later than 3 years from current date, and affix on outer panel. Page 11

Perfect 16 Warranty & Support Limited Parts Warranty Conditions We are proud to cover the Perfect 16 air cleaning system with a ten (10) year limited warranty. Within 10 years from the original purchase date by the end-user from the authorized IQAir Dealer/Installer if this appliance or any part thereof (with the exception of filters) is proved to be defective by reason only of faulty workmanship or materials, IQAir North America, Inc. will at their option repair or replace the faulty appliance or part free of charge. This warranty is for parts and does not include labor. The warranty for replaced parts will automatically expire with the termination of the original device s warranty. This warranty shall not apply to damage caused by misuse, wear and tear, neglect, unauthorized repair, damage caused by installation, adaptation, modification or use in an improper manner or inconsistent with IQAir s operating and maintenance instructions, or to wear or deterioration resulting from environmental conditions or to damage sustained during transit. IQAir North America, Inc. will not be liable under this warranty for any fault or damage arising from defective workmanship. IQAir North America, Inc. will not refund shipping, handling or insurance costs for warranty repairs. Obvious defects must be communicated to the authorized IQAir Dealer/Installer within 10 days of the purchase date. To secure your warranty rights and prevent possible transport damage, all products must be returned in original IQAir packaging. Please keep the original packaging. Alternatively, original IQAir packaging can be ordered from IQAir North America, Inc. IMPORTANT NOTE: All products you wish to return for service or repair must be accompanied with a Return Authorization Number (RA Number). This number can be obtained by contacting the IQAir Technical Support Team. The RA Number must be clearly visible on all external packaging. IQAir North America Inc. reserves the right to refuse any shipment received without RA Number and to return the shipment at the original sender s cost. IQAir s Technical Support Team Should technical questions arise before, during or after installation, please contact the IQAir Technical Support Team. You may contact the IQAir Technical Support Team at: IQAir North America, Inc. 14351 Firestone Blvd La Mirada, CA 90638 Phone: 562-236-1199 Fax: 562-903-7601 e-mail: support@iqair.com Toll-free: 888-560-1020 To expedite your service, please have the following information ready when contacting us: IQAir model Shell number Serial number (found on the base of the unit) Your details (name, address, phone, e-mail) Date of purchase Description of problem Thank you for choosing IQAir. Page 12 208 04 01 01 / 080612_IQ_MA_P16_US