Operating Instructions Electronic transformers for lowvoltage halogen lamps

Similar documents
Operating Instructions. Tronic Dimmer

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Figure 1: Device components

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

1 Safety instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Power enhancement for the dimmers contained in the reference list (see section Technical

LED CONVERTERS FOR LED MODULES 24 V

Energy Profile Installation Instructions

LED Driver Compact fixed output

LED Driver Compact fixed output

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

QTi DALI 1X36/ DIM

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

Uninterruptible Power System

Buffer Charging Systems

Operating Instructions

FL ballasts Electronic fixed output PC BASIC, 4 28 W PC BASIC

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Pure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A

Installation Instructions

LED control gear Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Installation and Operating Instructions Electric Vibrators HV/VFL Series

MEANWELL DC/AC POWER INVERTERS

Emergency lighting units PC COMBO

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

High Frequency SineWave Guardian TM

Emergency lighting units EM LED Light Engines. Module EM-ES 08/10/12 Mk2 EM LED linear / area

Installation Instructions

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

ADVANCED GUIDE TO LED LIGHTS & DRIVERS. astrolighting.com

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

LED Driver Linear / area fixed output

Emergency lighting units EM series

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Safety Sensor CSS 180 Product Information

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

1RECHARGEABLE APPLIANCES

Emergency lighting units EM powerled

Touch Sensor 2 plus Installation Instructions

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Emergency lighting units PC COMBO

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

PRO Dimmer INSTRUCTION MANUAL

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Installation & User Instructions

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

Emergency lighting units EM powerled

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii Original Sheet 5 RULE NO. 2 CHARACTER OF SERVICE

Emergency lighting units EM converterled

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

INSTALLATION & MAINTENANCE MANUAL HBL

Miniature Circuit-Breakers (MCBs)

PC T8 TEC, W PC TEC

INSTALLATION INSTRUCTIONS

Uninterruptible Power System

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

FLUORESCENT INDUCTION

SOLUS 9 SPOTLIGHT - LED. Features Include. Applications. Benefits

Back-UPS CS Back-UPS CS 350

Emergency lighting units EM converterled

Overview Overvoltage protection

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Sivoia QED R Installation Instructions Please Leave for Occupant

E61, E63, E64 BMW AG - TIS

.3 Section Waste Management and Disposal.

Fluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.

CP Automatic capacitor bank

Technical information

Ceramic PTC Thermistor:

Optimizing Emergency Power Systems for Health Care Applications

SCREW SPINDLE PUMPS COOLING, LUBRICATING, CHIP HANDLING, PRESSURE BOOSTING, FLUSHING, MAINTAINING TEMPERATURES...

Transcription:

Operating Instructions Electronic transformers for lowvoltage halogen lamps 1. Safety instructions Attention: Electrical equipment must be installed and fitted by qualified electricians only. To prevent electric shocks, always shut off the mains supply (by cutting out the circuit-breaker) before working on the device or before replacing the lamp. Any non-observance of the safety warnings and fitting instructions may result in damage to the device and cause fire or other hazards. 2. Function Use for 12 V halogen lamps. The device can only be dimmed with JUNG TRONIC or Universal dimmers. Never use dimmers from other manufacturers. Using dimmers from other manufacturers may involve a risk of fire. Lamp-saving soft-start at switch-on (except for 40 W / 70 W Qu). Overload and over-temperature protection by automatic reduction of power (40 / 70 / 105 / 150 W transformers) or shut-off until device has cooled down (70 W Qu and 200 W transformer). Short-circuit protection (40 / 70 / 105 / 150 W transformers): Shut-off with automatic restart after removal of short-circuit.

Short-circuit protection (200 W transformer): Shut-off with automatic restart if short-circuit is removed within 5 seconds. Thereafter, permanent shut-off until manual restart. 3. Fitting instructions TRONIC transformers are protected against tansient overvoltages (mains voltage peaks) in acc. with EN 61547. To protect them against higher overvoltages (produced by the switching of fluorescent lamps, discharge lamps, motors and other inductive loads) install a separate load circuit for TRONIC transformers. The TRONIC transformer may otherwise be damaged if the circuit is switched by peak voltages.if there is a risk of mains voltage spikes, a overvoltage protection module must be used in addition and connected on the primary side in parallel to the TRONIC transformers (between L and N) fig. (2)a.If TRONIC transformers are to be dimmed, the overvoltage protection module must be connected in parallel to the series connection of dimmer and TRONIC transformers, fig. (2)b. Figure 2a Figure 2b 1 overvoltage protection module is sufficient for about 10 TRONIC transformers per circuit. Observe the power rating limits of the transformers. Insufficient loading may lead to flickering of the lamps connected. 2

Install and connect the transformers as shown in figure (1), (3) (keep twice the distance between individual transformers) and figure (4). Figure 1 Figure 3 Figure 4 3

Avoid sources of heat (e.g. lamps) in the immediate vicinity of the transformer. In critical cases, measure the temperature at the Tc point. Recommended cross-section and type of secondary cable, fig (5). Secondary cable: see technical data, fig. (9). Power per line Wire crosssection Recommended type of secondary wire 40 W 0,75 mm² z.b. H 03 V V-F 2 x 0,75 mm² 50 W 105 W 1,5 mm² z.b. H 05 V V-F 2 x 1,5mm² 110 W 150 W 2,5 mm² z.b. H 05 V V-F 2 x 2,5 mm² 155 W 200 W distribute power to at least 2 lines (min. 2 x 1,5 mm²) Figure 5 If several lamp circuits are to be connected to a transformer, it is recommended to use a distributor, fig. (6). Figure 6 The secondary line must not be connected to the secondary line of other TRONIC transformers and not be laid close to the mains supply line, fig. (7). Figure 7 4

In TRONIC transformers without stress-relief, the cable must be protected against pushing and pulling with a suitable clamp at the TRONIC transformer. For TRONIC transformers with prepared connecting cable, a suitable box to connect the mains supply must be used. For TRONIC transformers equipped with a stressrelieving device, use at least a H 05 VV-F 2x1.5 mm² cable for the mains supply. Stripping length for outer cable sheath and base insulation: see fig. (8). Figure 8 Important: When TRONIC transformers with multipoint terminals on the primary side for mains supply through-connection are used, the maximum number of interconnected TRONIC transformers is limited to 10. Design / Dimension (mm) 4. Technical data 10-40 W 73 x 35,5 x 18 20-70 W Nominal rating 10-40 W T50 20-60 W T50 20-70 W 20-105 W 20-150 W 50-200 W 49 x 48 x 28 152 x 43,5x 17,5 175 x 42 x 18 176 x 42 x 38 212 x 48,5 x 46 20-70 W T50 20-105 W T50 20-150 W T50 50-200 W T50 20-70 W T40 Supply voltage AC 230 V ~ Mains frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 Hz Output voltage 11,7 V eff ~ 50 khz 11,7 V eff 11,7 V eff 11,8 V eff 11,7 V eff 11,5 V eff Primary current Max. ambient temperature Max. housing temperature Max. length of secondary line 0,18 A (40 W) 0,33 A (60 W) 0,33 A (70 W) 0,45 A (105 W) 0,71 A (150 W) 0,95 A (200 W) 50 C 50 C (60 W) 50 C 50 C 50 C 45 C 85 C 75 C 90 C 80 C 75 C 65 C 2 m 2 m 2 m 2 m 2 m 2 m Figure 9 5

5. Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55. 80 65 51 Telefax: +49 (0) 23 55. 80 61 89 E-Mail: mail.vki@jung.de General equipment Service-Line: +49 (0) 23 55. 80 65 55 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX/EIB equipment Service-Line: +49 (0) 23 55. 80 65 56 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The -Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. 6