Protection Equipment. 5/2 Introduction

Similar documents
Protection Equipment

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RU2 Thermal Overload Relays

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Motor Starter Protectors

Motor Starter Protectors

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Protective Devices: Circuit-Breakers 1 )

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

General data 5/37. Overview

3VU13, 3VU16 Circuit-Breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

3NP1 Fuse Switch Disconnectors up to 630 A

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

BETA Switching Switches and Light Indicators

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

FMotor Circuit Controllers

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

Series KTU7 UL489 Molded Case Circuit Breakers

MS General Information Extended Product Type: MS

Series KTU7 UL489 Molded Case Circuit Breakers

Control Circuit Protection

Manual Motor Starters. Meta-MEC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Industry Automation Control Components

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Electronic overload relay EF65, EF96 and EF146

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

3 - Protection components Motor circuit-breakers

Thermal overload relay TF65 and TF96

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Technical data for manual motor starters Type MS325

Electronic overload relays EF205 and EF370

Technical Information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Air Circuit Breakers

PKZ and PKE motor-protective circuit-breakers

Application Mini Contactors for Motors and Resistive Loads

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Phone: Fax: Web: -

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Short form catalogue. Motor protection & control

Air Circuit Breakers

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

AF40... AF96 3-pole contactors Technical data

AF series contactors (9 2650)

Thermal overload relay TF140DU and TF140DU-V1000

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

SENTRON Switching and Protection Devices Switch Disconnectors

D509E. Manual Motor - Starters

CA Z-EN Overload relays, CT-operated overload relays

4 - Miniature controls

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Motor Controllers + Circuit Breakers

Short form catalogue Motor protection and control Manual motor starters

For Operation in the Control Cabinet

XT IEC Power Control Manual Motor Protectors

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Motor Protection Circuit Breakers 3VU13 and 3VU16

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Product Line Overview. The Most Logically Designed Contact Assembly

DEVICE STATE/BYPASSED FAILURE OVERLOAD

AF series contactors (9 2650)

Meta Solution. Contactors and Overload relays

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

A302DN.40/.63A Thermal Current Motor Starter

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

Bulletin 140M Motor Protectors

Meta Solution. Contactors and Overload relays

KT4 Manual Motor Starter

UMBW-UL489 and UL1077 Listed

Motor protective circuit breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

and other modular devices for low voltage installation

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

3VT Kompaktleistungsschalter bis 630A

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Protection components

Transcription:

Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1 For starter combinations for export applications /16 For transformer protection /17 For system protection according to UL 489/CSA C22.2 No. -02 /18 For transformer protection according to UL 489/CSA C22.2 No.-02 Accessories /19 Mountable accessories /22 Busbar accessories /2 3RV29 infeed system /29 Rotary operating mechanisms /30 Mounting accessories /33 Enclosures and front plates Overload Relays /36 General data SIRIUS 3RU2 Thermal Overload Relays /39 General data /4 3RU2 up to 40 A for standard applications /47 Accessories SIRIUS 3RB3 Solid-State Overload Relays /49 General data /4 3RB30, 3RB31 up to 40 A for standard applications /7 Accessories Technical Information can be found at www.siemens.com/industrial-controls/ support under Product List: - Technical specifications under Entry List: - Updates - Download - FAQ - Manuals - Characteristics - Certificates

Protection Equipment Introduction Overview Type 3RV20 3RV21 3RV23 3RV24 3RV27 3RV28 SIRIUS 3RV2 motor starter protectors and circuit breakers up to 40 A Uses System protection 1) 1) -- -- Motor protection -- -- -- -- -- Motor protection with overload relay function Has this function or can use this accessory -- Does not have this function or cannot use this accessory 1) For symmetrical loading of the three phases. 2) With molded-plastic enclosure 00 V AC. 3) For overload protection of the motors, appropriate overload relays must be used. -- -- -- -- -- Starter combinations -- -- -- -- -- Transformer protection -- -- -- Size S00, S0 S00, S0 S00, S0 S00, S0 S00 S00 Rated current I n Size S00 Size S0 Rated operational voltage U e acc. to IEC A A Up to 16 Up to 40 Up to 16 Up to 32 Up to 16 Up to 40 Up to 16 Up to 2 Up to 1 -- 4) According to UL 489 at 480 Y/277 V AC: 6 ka. According to CSA 22.2 no.0 @ 600 Y/347 V AC: 10 KA ) Terminal covers are available for 3RV20 motor starter protectors with ring lug terminal connection for motor protection. Up to 1 -- V 690 AC 2) 690 AC 2) 690 AC 2) 690 AC 2) 690 AC 690 AC Rated frequency Hz 0/60 0/60 0/60 0/60 0/60 0/60 Trip class CLASS 10 CLASS 10 -- CLASS 10 -- -- Thermal A overload release A 0.11... 0.16 to 34... 40 0.11... 0.16 to 27... 32 None 3) 0.11... 0.16 to 20... 2 0.16... 1 nonadjustable 0.16... 1 nonadjustable Electronic releases A multiple of the 13 times 13 times 13 times 20 times 13 times 20 times rated current Short-circuit breaking capacity ka 12/0/6/30 0/6 12/0/6 /100 4) 4) I cu at 480 V AC/600 V AC Pages /12, /13 /14 /1 /16 /17 /18 Accessories For sizes S00 S0 S00 S0 S00 S0 S00 S0 S00 S00 Auxiliary switches Signaling switches -- -- Undervoltage releases -- -- Shunt releases -- -- Isolator modules -- -- Insulated three-phase busbar system -- -- -- -- Busbar adapters -- -- Door-coupling rotary operating mechanisms Link modules -- -- Enclosures for surface mounting -- -- Enclosures for flush mounting -- -- Front plates -- -- Infeed system -- -- -- -- Terminal covers for ring lug terminal connections -- ) -- ) -- -- -- -- -- -- -- -- Sealable scale covers for setting knobs -- -- -- -- Pages /19... /3 /2

Protection Equipment Introduction Overview 3RV2011 3RV2021 3RV2023 FLA Adjustment Range Single Phase HP Ratings Three Phase HP Ratings 1) For further technical data and completion of the part numbers, refer to page /12. Instantaneous Overcurrent Release CSA SCCR ka 600Y/347V Order No. 11V 230V 200V 230V 460V 7V A ka 3RV20/21/23 3RV2011 Size S00 1) 0.11-0.16 -- -- - -- - -- 2.1 30kA 3RV2011-0AA10 0.14-0.2 -- -- -- -- -- -- 2.6 30kA 3RV2011-0BA10 0.18-0.2 -- -- -- -- -- -- 3.3 30kA 3RV2011-0CA10 0.22-0.32 -- -- -- -- -- -- 4.2 30kA 3RV2011-0DA10 0.28-0.4 -- -- -- -- -- --.2 30kA 3RV2011-0EA10 0.3-0. -- -- -- -- -- -- 6. 30kA 3RV2011-0FA10 0.4-0.63 -- -- -- -- -- -- 8.2 30kA 3RV2011-0GA10 0.-0.8 -- -- -- -- -- 1/2 10 30kA 3RV2011-0HA10 0.7-1 -- -- -- -- -- 1/2 13 30kA 3RV2011-0JA10 0.9-1.2 -- -- -- -- 1/2 1/2 16 30kA 3RV2011-0KA10 1.1-1.6 -- 1/10 -- -- 3/4 3/4 21 30kA 3RV2011-1AA10 1.4-2 -- 1/8 -- -- 3/4 1 26 30kA 3RV2011-1BA10 1.8-2. -- 1/6 1/2 1/2 1 1 1/2 33 30kA 3RV2011-1CA10 2.2-3.2 1/10 1/4 1/2 3/4 1 1/2 2 42 30kA 3RV2011-1DA10 2.8-4 1/8 1/3 3/4 3/4 2 3 2 30kA 3RV2011-1EA10 3.- 1/6 1/2 1 1 3 3 6 30kA 3RV2011-1FA10 4.-6.3 1/4 1/2 1 1 1/2 3 82 30kA 3RV2011-1GA10.-8 1/3 1 2 2 104 30kA 3RV2011-1HA10 7-10 1/2 1 1/2 2 3 7 1/2 130 30kA 3RV2011-1JA10 9-12. 1/2 2 3 3 7 1/2 10 163 30kA 3RV2011-1KA10 11-16 1 2 10 -- 208 30kA 3RV2011-4AA10 3RV2021 Size S0 1) 11-16 1 2 3 10 -- 208 -- 3RV2021-4AA10 14-20 1 1/2 3 10 -- 260 -- 3RV2021-4BA10 17-22 1 1/2 3 7 1/2 1 -- 286 -- 3RV2021-4CA10 20-2 2 3 7 1/2 1 -- 32 -- 3RV2021-4DA10 23-28 2 7 1/2 10 20 -- 364 -- 3RV2021-4UA10 27-32 2 7 1/2 10 20 -- 400 -- 3RV2021-4EA10 30-36 3 10 10 2 -- 432 -- 3RV2021-4PA10 34-40 3 7 1/2 10 10 30 -- 480 -- 3RV2021-4FA10 3RV2023 Size S0 1) 600V AC 9-12. -- -- -- -- -- -- CS /UL -- 3RV2023-1KA10 11-16 -- -- -- -- -- -- CS /UL -- 3RV2023-4AA10 14-20 -- Availability and Data to be announced -- CS /UL -- 3RV2023-4BA10 17-22 -- -- -- -- -- -- CS /UL -- 3RV2023-4CA10 20-2 -- -- -- -- -- -- CS /UL -- 3RV2023-4DA10 /3

Protection Equipment Introduction (( )) Type 3RU21 3RB30 3RB31 SIRIUS overload relays up to 40 A Uses System protection 1) 1) 1) Motor protection Alternating current, three-phase Alternating current, single-phase -- -- Direct current -- -- Size of contactor S00, S0 S00, S0 S00, S0 Rated operational current I e Size S00 Size S0 A A Up to 16 Up to 40 Up to 16 Up to 40 Up to 16 Up to 40 Rated operational voltage U e V 690 AC 690 AC 690 AC Rated frequency Hz 0/60 0/60 0/60 Trip class CLASS 10 CLASS 10, 20 CLASS, 10, 20, 30 adjustable Thermal overload release Solid-state overload release Rating for induction motor at 400 V AC A A A 0.11... 0.16 to 34... 40 -- 0.1... 0.4 to 10... 40 -- -- 0.1... 0.4 to A 10... 40 kw 0.04... 18. 0.04... 18. 0.04... 18. Pages /4, /46 /4, / /6 Accessories For sizes S00 S0 S00 S0 S00 S0 Terminal brackets for stand-alone installation Mechanical RESET Cable releases for RESET Electrical remote RESET -- -- Integrated in the unit Terminal covers for ring lug terminal -- 2) -- 2) -- -- -- -- connections Sealable covers for setting knobs Pages /47, /48 /7, /8 /7, /8 Has this function or can use this accessory 1) The units are responsible in the main circuit for overload protection of the -- Does not have this function or cannot use this accessory assigned electrical loads (e.g. motors), starter cable and other switching and protection devices in the respective motor starter. 2) Terminal covers for ensuring finger-safe touch protection are available for 3RU21 overload relays with ring lug terminal connections for mounting onto contactors. /4

Protection Equipment Notes /

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A General data Overview The following illustration shows our 3RV2 motor starter protectors with the accessories which can be mounted for the various sizes, see also "Introduction" --> "Overview" on page /2. For accessories, see page /19 onwards. 7 6 2 3 8 Mountable accessories 1 Transverse auxiliary switch 2 Lateral auxiliary switch with 2 contacts 3 Lateral auxiliary switch with 4 contacts 4 Shunt release Undervoltage release without/with leading contacts 6 Signaling switch 7 Isolator module 8 Terminal block type E NSB0_02076 4 1 Mountable accessories for 3RV2 motor starter protectors Type of construction The motor starter protectors are available in 2 sizes: Size S00 - width 4 mm, max. rated current 16 A, at 460 V AC suitable for induction motors up to 10 HP. Size S0 - width 4 mm, max. rated current 40 A, at 460 V AC suitable for induction motors up to 30 HP. Note Screw terminals Spring-type terminals Ring lug terminal connection Motor starter protectors with spring-type terminals, size S0 (left) and motor starter protectors with screw terminals, size S00 (right) The new 3RV2 motor starter protectors are compact, current limiting motor starter protectors which are optimized for motor starters. The motor starter protectors are used for switching and protecting three-phase induction motors of up to 30 HP at 460 V AC and for other loads with rated currents of up to 40 A. These terminals are indicated in the corresponding tables by the symbols shown on orange backgrounds. "Increased safety" type of protection EEx e according to ATEX directive 94/9/EC The 3RV20 motor starter protectors are suitable for the overload protection of explosion-proof motors with "increased safety" type of protection EEx e; see Chapter 9 "Appendix" --> "Standards and Approvals" --> "Type Overview of Approved Devices for Explosion-Protected Areas (ATEX Explosion Protection)". /6

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A General data Application Operating conditions 3RV2 motor starter protectors are suitable for use in any climate. They are intended for use in enclosed rooms in which no severe operating conditions (such as dust, caustic vapors, hazardous gases) prevail. When installed in dusty and damp areas, suitable enclosures must be provided. 3RV2 motor starter protectors can optionally be fed from the top or from below. The permissible ambient temperatures, the maximum switching capacities, the tripping currents and other boundary conditions can be found in the technical specifications and tripping characteristics, see note on Technical Information on page /1. 3RV2 motor starter protectors are suitable for operation in IT systems (IT networks). In this case, the different short-circuit breaking capacity in the IT system must be taken into account. Since operational currents, starting currents and current peaks are different even for motors with identical power ratings due to the inrush current, the motor ratings in the selection tables are only guide values. The specific rated and start-up data of the motor to be protected is always paramount to the choice of the most suitable motor starter protector. This also applies to motor starter protectors for transformer protection. Possible uses The 3RV2 motor starter protectors can be used: For short-circuit protection For motor protection (also with overload relay function) For system protection For short-circuit protection for starter combinations For transformer protection As main and EMERGENCY-STOP switches For operation in IT systems (IT networks) For switching of DC currents In areas subject to explosion hazard (ATEX) For more information see the note on Technical Information on page /1. More information Order No. scheme Digit of the Order No. 1st - 3rd 4th th 6th 7th 8th 9th 10th 11th 12th 13th 14th 1th 16th @@@ @ @ @ @ @ @ @ @ @ @ @ @ @ Motor starter protector 3 R V SIRIUS 2nd generation 2 Type of motor starter protector @ Size @ Switching capacity @ Setting range for overload release @ @ Trip class (CLASS) @ Connection method @ With or without auxiliary switch @ Special versions @ @ @ @ Example 3 R V 2 0 1 1 1 A A 1 0 Note: The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order numbers. For your orders, please use the order numbers quote in the catalog under the Selection and ordering data section. /7

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A General data General technical specifications Type 3RV2. 1 3RV27 11, 3RV28 11 3RV2. 2 Size S00 S00 S0 Dimensions (W x H x D) Screw terminals Spring-type terminals Standards IEC 60947-1, EN 60947-1 (VDE 0660 Part 100) IEC 60947-2, EN 60947-2 (VDE 0660 Part 101) IEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102) UL 489, CSA C22.2-No.-02 mm mm Number of poles 3 4 x 97 x 91 4 x 109 x 91 Yes Yes Yes Yes 4 x 144 x 92 -- Max. rated current I n max A 16 40 (= max. rated operational current I e ) Permissible ambient temperature Storage/transport C 0... +80 Operation I n : 0.16... 32 A C 20... +70 1) I n : 36... 40 A C 20... +40 2) Permissible rated current at inside temperature of control cabinet +60 C % 100 +70 C % 87 Permissible rated current at ambient temperature of enclosure (applies to motor starter protectors inside enclosure 32 A) +3 C % 100 +60 C % 87 Rated operational voltage U e Acc. to IEC V AC 690 3) Acc. to UL/CSA V AC 600 Rated frequency Hz 0/60 Rated insulation voltage U i V 690 Rated impulse withstand voltage U imp kv 6 Utilization category IEC 60947-2 (motor starter protector/circuit breaker) A IEC 60947-4-1 (motor starter) AC-3 Trip class CLASS Acc. to IEC 60947-4-1 10 DC short-circuit breaking capacity (time constant t = ms) 1 conducting path 10 V DC ka 10 2 conducting paths in series 300 V DC ka 10 3 conducting paths in series 40 V DC ka 10 Power loss P v for each motor starter protector Dependent on the rated current I n (upper setting range) H W D I n : 0.16... 0.63 A W I n : 0.8... 6.3 A W 6 I n : 8... 16 A W 7 I n : 16 A W -- 7 I n : 20... 2 A W -- 8 R percurrentpath = ------------- P I n : 28... 32 A W -- 11 2 3 I n : 36... 40 A W -- 14 Shock resistance Acc. to IEC 60068-2-27 g/ms 2/11 (square and sine pulse) Degree of protection Acc. to IEC 6029 IP20 4) Touch protection Acc. to EN 0274 Finger-safe Temperature compensation Acc. to IEC 60947-4-1 C 20... +60 Phase failure sensitivity Acc. to IEC 60947-4-1 Yes Explosion protection safe operation of motors with Yes for 3RV20 "increased safety" type of protection EC type test certificate number according to On request directive 94/9/EC (ATEX) Isolating function Acc. to IEC 60947-2 Yes Main and EMERGENCY-STOP switch Acc. to IEC 60204-1 Yes characteristics ) (VDE 0113) Protective separation between Acc. to EN 60947-1 main and auxiliary circuits, required for PELV applications Up to 400 V + 10 % Yes Up to 41 V + % (higher voltage on request) Yes Permissible mounting position Any, acc. to IEC 60447 start command "I" right-hand side or top Mechanical endurance Operating cycles 100 000 Electrical endurance Operating cycles 100 000 Max. switching frequency per hour (motor starts) 1/h 1 1) Over +60 C current reduction. ) With appropriate accessories. 4 x 97 x 91 4 x 119 x 91 2) The devices must not be mounted side-by-side and they must not be assembled with link modules with contactors. A lateral clearance of 9 mm is required. 3) With molded-plastic enclosure 00 V. 4) Terminal compartment IP00 (exception: 3RV20 11-..2. motor starter protectors with spring-type terminals in degree of protection IP20). /8

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Rated data of the auxiliary switches and signaling switches Max. Rated voltage Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC, 2 NO + 2 NC Signaling switch General data Transverse auxiliary switch with 1 CO 1 NO + 1 NC, 2 NO Acc. to NEMA (UL) V AC 600 20 Acc. to NEMA (CSA) V AC 600 20 Uninterrupted current A 10 10 2. Switching capacity 1 NO + 1 NC, 2 NO, 2 NC: A600, Q300; 2 NO + 2 NC: A300, Q300 A600, Q300 B600, R300 C300, R300 Front transverse auxiliary switches Switching capacity for different voltages 1 CO 1 NO + 1 NC, 2 NO Rated operational current I e At AC-1, alternating voltage - 24 V A 4 2-230 V A 3 0. - 400 V A 1. -- - 690 V A 0. -- At AC-12 = I th, alternating voltage - 24 V A 10 2. - 230 V A 10 2. - 400 V A 10 -- - 690 V A 10 -- At DC-13, direct voltage L/R 200 ms - 24 V A 1 1-48 V A -- 0.3-60 V A -- 0.1-110 V A 0.22 -- - 220 V A 0.1 -- Minimum load capacity V 17 ma 1 Front transverse solid-state compatible auxiliary switches Switching capacity for different voltages 1 CO Rated operational voltage U e Alternating voltage V 12 Rated operational current I e /AC-14 at U e = 12 V A 0.1 Rated operational voltage U e Direct voltage L/R 200 ms V 60 Rated operational current I e /DC-13 at U e = 60 V A 0.3 Minimum load capacity V ma 1 Lateral auxiliary switches with signaling switch Switching capacity for different voltages: Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC, 2 NO + 2 NC; Signaling switches Rated operational current I e At AC-1, alternating voltage - 24 V A 6-230 V A 4-400 V A 3-690 V A 1 At AC-12 = I th, alternating voltage - 24 V A 10-230 V A 10-400 V A 10-690 V A 10 At DC-13, direct voltage L/R 200 ms - 24 V A 2-110 V A 0. - 220 V A 0.2-440 V A 0.1 Minimum load capacity V 17 ma 1 /9

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A General data Auxiliary releases Power consumption 1) Prospective short-circuit current < 0.4 ka. Undervoltage releases During pick-up - AC voltages VA/W 20.2/13 20.2/13 - DC voltages W 20 13... 80 During uninterrupted duty - AC voltages VA/W 7.2/2.4 -- - DC voltages W 2.1 -- Response voltage Shunt releases Tripping V 0.3... 0.7 x U s 0.7... 1.1 x U s Pickup V 0.8... 1.1 x U s -- Maximum opening time ms 20 Short-circuit protection for auxiliary and control circuits Melting fuses gg A 10 Miniature circuit breaker, C characteristic A 6 1) Type 3RV2. 11 3RV2. 21 3RV27 11, 3RV28 11 Size S00 S0 S00 Width 4 mm 4 mm 4 mm Conductor cross-sections of main circuit Connection type screw terminals Screw terminals Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 M4, Pozidriv size 2 Operating devices mm... 6... 6... 6 Prescribed tightening torque Nm 0.8... 1.2 2... 2. 2.... 3 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.7... 2.) 1), 2 x 4 Stranded mm 2 2 x (0.7... 2.) 1), 2 x 4 Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) 2 x (1... 2.) 1), 2 x (2.... 6) 1), 1 x 10 AWG cables, solid or stranded AWG 2 x (18... 14) 1), 2 x 12 Connection type spring-type terminals Spring-type terminals 2 x (1... 2.) 1), 1... 10, 2 x (2.... 10) 1) max. 2 x 10 2 x (1... 2.) 1), 1.... 2, 2 x (2.... 10) 1) max. 10 + 2 1... 16, max. 6 + 16 2 x (16... 12) 1), 2 x (14... 10) 2 x (14... 8) 1) Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.... 4) 2 x (1... 10) -- Finely stranded without end sleeve mm 2 2 x (0.... 2.) 2 x (1... 6) -- Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 2.) 2 x (1... 6) -- AWG cables, solid or stranded AWG 2 x (20... 12) 2 x (18... 8) -- Max. external diameter of the conductor insulation mm 3.6 3.6 -- Connection type ring lug terminals Ring lug terminal connection Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 -- Operating devices mm... 6... 6 -- Prescribed tightening torque Nm 0.8... 1.2 2... 2. -- Usable ring lug terminals d 3 mm d 2 = min. 3.2, d 2 = min. 4.3, -- DIN 46234 without insulation sleeve DIN 4622 without insulation sleeve DIN 46237 with insulation sleeve JIS C280 Type R without insulation sleeve JIS C280 Type RAV with insulation sleeve JIS C280 Type RAP with insulation sleeve d 2 d 3 = max. 7. d 3 = max. 12.2 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply. I2_12740 /10

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A General data Type 3RV2. 11 3RV2. 21 3RV27 11, 3RV28 11 Size S00 S0 S00 Width 4 mm 4 mm 4 mm Conductor cross-sections for auxiliary and control circuits Connection type screw terminals Screw terminals Terminal screw M3, Pozidriv size 2 Operating devices mm... 6 Prescribed tightening torque Nm 0.8... 1.2 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid or stranded mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) AWG cables, solid or stranded AWG 2 x (18... 14) 1), 2 x (20... 16) 1) Connection type spring-type terminals Spring-type terminals Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.... 2.) Finely stranded without end sleeve mm 2 2 x (0.... 1.) Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) AWG cables, solid or stranded AWG 2 x (20... 14) Max. external diameter of the conductor insulation mm 3.6 Connection type ring lug terminals Ring lug terminal connection Terminal screw M3, Pozidriv size 2 Operating devices mm... 6 Tightening torque Nm 0.8... 1.2 Usable ring lug terminals mm d 2 = min. 3.2, d 3 = max. 7. DIN 46234 without insulation sleeve DIN 4622 without insulation sleeve DIN 46237 with insulation sleeve JIS C280 Type R without insulation sleeve JIS C280 Type RAV with insulation sleeve JIS C280 Type RAP with insulation sleeve 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply. d 3 d 2 I2_12740 /11

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Motor Starter Protectors For motor protection Selection and ordering data CLASS 10, without auxiliary switches 1) The 3RV20 1 & 3RV20 2 MSP's can be used as components in Group Installation per NEC 430-3(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV2 is used as a component in Group Installation, multiple MSP's can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter. The 3RV20 can also be used as Type E self-protected manual combination starters per CSA 22.2 without the use of an additional type E terminal adapter. See page /23 and /31. 3RV20 11-0AA10 3RV20 11-0EA20 3RV20 21-4AA10 3RV20 21-4AA20 Rated current Suitable for induction motors 2) at 600 V Setting range for thermal overload release Instantaneous electronic releases Short-circuit Breaking Capacity at 460 V AC in Group Installation Short-circuit Breaking Capacity at 600 V AC in Group Installation Screw terminals A HP A A ka ka kg kg Size S00 0.16 -- 0.11... 0.16 2.1 6 30 3RV20 11-0AA10 0.260 3RV20 11-0AA20 0.280 0.2 -- 0.14... 0.2 2.6 6 30 3RV20 11-0BA10 0.260 3RV20 11-0BA20 0.290 0.2 -- 0.18... 0.2 3.3 6 30 3RV20 11-0CA10 0.260 3RV20 11-0CA20 0.290 0.32 -- 0.22... 0.32 4.2 6 30 3RV20 11-0DA10 0.260 3RV20 11-0DA20 0.280 0.4 -- 0.28... 0.4.2 6 30 3RV20 11-0EA10 0.260 3RV20 11-0EA20 0.290 0. -- 0.3... 0. 6. 6 30 3RV20 11-0FA10 0.260 3RV20 11-0FA20 0.290 0.63 -- 0.4... 0.63 8.2 6 30 3RV20 11-0GA10 0.260 3RV20 11-0GA20 0.280 0.8 -- 0.... 0.8 10 6 30 3RV20 11-0HA10 0.260 3RV20 11-0HA20 0.280 1 1/2 0.7... 1 13 6 30 3RV20 11-0JA10 0.320 3RV20 11-0JA20 0.30 1.2 1/2 0.9... 1.2 16 6 30 3RV20 11-0KA10 0.320 3RV20 11-0KA20 0.30 1.6 3/4 1.1... 1.6 21 6 30 3RV20 11-1AA10 0.320 3RV20 11-1AA20 0.30 2 1 1.4... 2 26 6 30 3RV20 11-1BA10 0.320 3RV20 11-1BA20 0.30 2. 1. 1.8... 2. 33 6 30 3RV20 11-1CA10 0.320 3RV20 11-1CA20 0.30 3.2 2 2.2... 3.2 42 6 30 3RV20 11-1DA10 0.330 3RV20 11-1DA20 0.30 4 3 2.8... 4 2 6 30 3RV20 11-1EA10 0.320 3RV20 11-1EA20 0.30 3 3.... 6 6 30 3RV20 11-1FA10 0.330 3RV20 11-1FA20 0.30 6.3 4.... 6.3 82 6 30 3RV20 11-1GA10 0.330 3RV20 11-1GA20 0.360 8.... 8 104 6 30 3RV20 11-1HA10 0.330 3RV20 11-1HA20 0.360 10 7. 7... 10 130 6 30 3RV20 11-1JA10 0.330 3RV20 11-1JA20 0.360 12. 10 9... 12. 163 6 30 3RV20 11-1KA10 0.330 3RV20 11-1KA20 0.360 16 -- 11... 16 208 6 --- 3RV20 11-4AA10 0.340 3RV20 11-4AA20 0.360 Size S0 16 -- 11... 16 208 6 --- 3RV20 21-4AA10 0.340 3RV20 21-4AA20 0.390 20 -- 14... 20 260 6 --- 3RV20 21-4BA10 0.340 3RV20 21-4BA20 0.400 22 -- 17... 22 286 6 --- 3RV20 21-4CA10 0.340 3RV20 21-4CA20 0.390 2 -- 20... 2 32 6 --- 3RV20 21-4DA10 0.340 3RV20 21-4DA20 0.400 28 -- 23... 28 364 0 --- 3RV20 21-4NA10 0.30 3RV20 21-4NA20 0.410 32 -- 27... 32 400 0 --- 3RV20 21-4EA10 0.30 3RV20 21-4EA20 0.410 36 -- 30... 36 432 12 --- 3RV20 21-4PA10 0.360 -- 40 -- 34... 40 480 12 --- 3RV20 21-4FA10 0.360 -- -- -- 9... 12. --- -- --- 3RV2023-1KA10 ------- 3RV2023-1KA20 ------ 3) -- -- 11... 16 --- -- --- 3RV2023-4AA10 ------- 3RV2023-4AA20 ------ -- -- 14... 20 --- -- --- 3RV2023-4BA10 ------- 3RV2023-4BA20 ------ -- -- 17... 22 --- -- --- 3RV2023-4CA10 ------- 3RV2023-4CA20 ------ -- -- 20... 2 --- -- --- 3RV2023-4DA10 ------- 3RV2023-4DA20 ------ 1) The 3RV20.1-..A.0 motor starter protectors up to 32 A are also available with ring lug terminal connection. The Order No. must be changed in the 11th position to "4": e. g. 3RV20 11-0AA40. 2) Guide value for 4-pole standard motors at AC 60 Hz 460 V. Select MSP by motor full load amps. Horsepower ratings for reference only. Auxiliary switches can be ordered separately (see "Mountable accessories"). 3) Availability and data to be announced. Spring-type terminals I n I cu Order No. Order No. /12

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Motor Starter Protectors For motor protection CLASS 10, with transverse auxiliary switch (1 NO + 1 NC) The 3RV20 1 & 3RV20 2 MSP's can be used as components in Group Installation per NEC 430-3(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV2 is used as a component in Group Installation, multiple MSP's can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter. The 3RV20 can also be used as Type E self-protected manual combination starters per CSA 22.2 without the use of an additional type E terminal adapter. See page /23 and /31. 3RV20 11-4AA1 with integrated transverse auxiliary switch 3RV20 11-0EA2 with integrated transverse auxiliary switch 3RV20 21-4AA1 with integrated transverse auxiliary switch 3RV20 21-4AA2 with integrated transverse auxiliary switch Rated current Suitable for induction motors 2) at 600 V Setting range for thermal overload release Instantaneous electronic releases Short-circuit Breaking Capacity at 460 V AC in Group Installation Short-circuit Breaking Capacity at 600 V AC in Group Installation Screw terminals A HP A A ka ka kg kg Size S00 0.16 -- 0.11... 0.16 2.1 6 30 3RV20 11-0AA1 0.280 3RV20 11-0AA2 0.300 0.2 -- 0.14... 0.2 2.6 6 30 3RV20 11-0BA1 0.280 3RV20 11-0BA2 0.310 0.2 -- 0.18... 0.2 3.3 6 30 3RV20 11-0CA1 0.280 3RV20 11-0CA2 0.310 0.32 -- 0.22... 0.32 4.2 6 30 3RV20 11-0DA1 0.280 3RV20 11-0DA2 0.300 0.4 -- 0.28... 0.4.2 6 30 3RV20 11-0EA1 0.280 3RV20 11-0EA2 0.310 0. -- 0.3... 0. 6. 6 30 3RV20 11-0FA1 0.280 3RV20 11-0FA2 0.310 0.63 -- 0.4... 0.63 8.2 6 30 3RV20 11-0GA1 0.280 3RV20 11-0GA2 0.300 0.8 -- 0.... 0.8 10 6 30 3RV20 11-0HA1 0.280 3RV20 11-0HA2 0.300 1 1/2 0.7... 1 13 6 30 3RV20 11-0JA1 0.340 3RV20 11-0JA2 0.370 1.2 1/2 0.9... 1.2 16 6 30 3RV20 11-0KA1 0.340 3RV20 11-0KA2 0.370 1.6 3/4 1.1... 1.6 21 6 30 3RV20 11-1AA1 0.340 3RV20 11-1AA2 0.370 2 1 1.4... 2 26 6 30 3RV20 11-1BA1 0.340 3RV20 11-1BA2 0.370 2. 1. 1.8... 2. 33 6 30 3RV20 11-1CA1 0.340 3RV20 11-1CA2 0.370 3.2 2 2.2... 3.2 42 6 30 3RV20 11-1DA1 0.30 3RV20 11-1DA2 0.370 4 3 2.8... 4 2 6 30 3RV20 11-1EA1 0.340 3RV20 11-1EA2 0.370 3 3.... 6 6 30 3RV20 11-1FA1 0.30 3RV20 11-1FA2 0.370 6.3 4.... 6.3 82 6 30 3RV20 11-1GA1 0.30 3RV20 11-1GA2 0.380 8.... 8 104 6 30 3RV20 11-1HA1 0.30 3RV20 11-1HA2 0.380 10 7. 7... 10 130 6 30 3RV20 11-1JA1 0.30 3RV20 11-1JA2 0.380 12. 10 9... 12. 163 6 30 3RV20 11-1KA1 0.30 3RV20 11-1KA2 0.380 16 -- 11... 16 208 6 --- 3RV20 11-4AA1 0.360 3RV20 11-4AA2 0.380 Size S0 16 -- 11... 16 208 6 --- 3RV20 21-4AA1 0.360 3RV20 21-4AA2 0.410 20 -- 14... 20 260 6 --- 3RV20 21-4BA1 0.360 3RV20 21-4BA2 0.420 22 -- 17... 22 286 6 --- 3RV20 21-4CA1 0.360 3RV20 21-4CA2 0.410 2 -- 20... 2 32 6 --- 3RV20 21-4DA1 0.360 3RV20 21-4DA2 0.420 28 -- 23... 28 364 0 --- 3RV20 21-4NA1 0.370 3RV20 21-4NA2 0.430 32 -- 27... 32 400 0 --- 3RV20 21-4EA1 0.370 3RV20 21-4EA2 0.430 36 -- 30...36 432 12 --- 3RV20 21-4PA1 0.380 -- 40 -- 34...40 480 12 --- 3RV20 21-4FA1 0.380 -- 1) Guide value for 4-pole standard motors at AC 60 Hz 460 V. Select MSP by motor full load amps. Horsepower ratings for reference only. Auxiliary switches can be ordered separately (see "Mountable accessories"). Spring-type terminals I n I cu Order No. Order No. /13

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Motor Starter Protectors For motor protection with overload relay function Selection and ordering data CLASS 10, with overload relay function (automatic RESET), without auxiliary switches 3RV21 11-0FA10 3RV21 21-4BA10 Rated current Suitable for induction motors 1) at 480 V Suitable for induction motors 1) at 600 V 1) Guide value for 4-pole standard motors at AC 60 Hz 600 V. Select MSP by motor full load amps. Horsepower ratings for reference only. 2) Accessories for mounting on the right and 3RV29 1 three-phase busbars cannot be used. Auxiliary switches can be ordered separately (see "Mountable accessories"). Setting range Thermal overload releases Instantaneous electronic releases Short-circuit breaking capacity at 480 V AC Short-circuit breaking capacity at 600 V AC I n I cu Order No. Screw terminals A HP A A ka ka kg Size S00 2) 0.16 -- -- 0.11... 0.16 2.1 6 30 3RV21 11-0AA10 0.320 0.2 -- -- 0.14... 0.2 2.6 6 30 3RV21 11-0BA10 0.320 0.2 -- -- 0.18... 0.2 3.3 6 30 3RV21 11-0CA10 0.320 0.32 -- -- 0.22... 0.32 4.2 6 30 3RV21 11-0DA10 0.320 0.4 -- -- 0.28... 0.4.2 6 30 3RV21 11-0EA10 0.320 0. -- -- 0.3... 0. 6. 6 30 3RV21 11-0FA10 0.320 0.63 -- -- 0.4... 0.63 8.2 6 30 3RV21 11-0GA10 0.320 0.8 -- -- 0.... 0.8 10 6 30 3RV21 11-0HA10 0.320 1 -- 1/2 0.7... 1 13 6 30 3RV21 11-0JA10 0.380 1.2 1/2 1/2 0.9... 1.2 16 6 30 3RV21 11-0KA10 0.380 1.6 3/4 3/4 1.1... 1.6 21 6 30 3RV21 11-1AA10 0.380 2 3/4 1 1.4... 2 26 6 30 3RV21 11-1BA10 0.380 2. 1 1. 1.8... 2. 33 6 30 3RV21 11-1CA10 0.380 3.2 1. 2 2.2... 3.2 42 6 30 3RV21 11-1DA10 0.390 4 2 3 2.8... 4 2 6 30 3RV21 11-1EA10 0.380 3 3 3.... 6 6 30 3RV21 11-1FA10 0.390 6.3 3 3 4.... 6.3 82 6 30 3RV21 11-1GA10 0.390 8.... 8 104 6 30 3RV21 11-1HA10 0.390 10 7. 7... 10 130 6 30 3RV21 11-1JA10 0.390 12. 7. 10 9... 12. 163 6 30 3RV21 11-1KA10 0.390 16 10 10 11... 16 208 6 -- 3RV21 11-4AA10 0.400 Size S0 2) 16 10 10 11... 16 208 6 -- 3RV21 21-4AA10 0.400 20 10 10 14... 20 260 6 -- 3RV21 21-4BA10 0.400 22 1 1 17... 22 286 6 -- 3RV21 21-4CA10 0.400 2 1 1 20... 2 32 6 -- 3RV21 21-4DA10 0.400 28 20 20 23... 28 364 0 -- 3RV21 21-4NA10 0.410 32 20 20 27... 32 400 0 -- 3RV21 21-4EA10 0.410 /14

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Circuit Breakers For starter combinations for export applications Selection and ordering data Without auxiliary switches These Circuit Breakers are designed for export only applications. 3RV23 11-4AC10 3RV23 11-0JC20 3RV23 21-4AC10 3RV23 21-4AC20 Rated current Suitable for induction motors 1) with P Thermal overload releases 2) Instantaneous overcurrent releases Short-circuit breaking capacity at 400 V AC Screw terminals A kw A A ka kg kg Size S00 0.16 0.04 Without 2.1 100 3RV23 11-0AC10 0.260 3RV23 11-0AC20 0.270 0.2 0.06 Without 2.6 100 3RV23 11-0BC10 0.260 3RV23 11-0BC20 0.280 0.2 0.06 Without 3.3 100 3RV23 11-0CC10 0.260 3RV23 11-0CC20 0.280 0.32 0.09 Without 4.2 100 3RV23 11-0DC10 0.260 3RV23 11-0DC20 0.280 0.4 0.09 Without.2 100 3RV23 11-0EC10 0.260 3RV23 11-0EC20 0.290 0. 0.12 Without 6. 100 3RV23 11-0FC10 0.260 3RV23 11-0FC20 0.290 0.63 0.18 Without 8.2 100 3RV23 11-0GC10 0.260 3RV23 11-0GC20 0.280 0.8 0.18 Without 10 100 3RV23 11-0HC10 0.260 3RV23 11-0HC20 0.280 1 0.2 Without 13 100 3RV23 11-0JC10 0.320 3RV23 11-0JC20 0.340 1.2 0.37 Without 16 100 3RV23 11-0KC10 0.320 3RV23 11-0KC20 0.30 1.6 0. Without 21 100 3RV23 11-1AC10 0.320 3RV23 11-1AC20 0.30 2 0.7 Without 26 100 3RV23 11-1BC10 0.320 3RV23 11-1BC20 0.30 2. 0.7 Without 33 100 3RV23 11-1CC10 0.320 3RV23 11-1CC20 0.30 3.2 1.1 Without 42 100 3RV23 11-1DC10 0.320 3RV23 11-1DC20 0.30 4 1. Without 2 100 3RV23 11-1EC10 0.320 3RV23 11-1EC20 0.30 1. Without 6 100 3RV23 11-1FC10 0.320 3RV23 11-1FC20 0.30 6.3 2.2 Without 82 100 3RV23 11-1GC10 0.330 3RV23 11-1GC20 0.30 8 3 Without 104 100 3RV23 11-1HC10 0.320 3RV23 11-1HC20 0.30 10 4 Without 130 100 3RV23 11-1JC10 0.330 3RV23 11-1JC20 0.360 12.. Without 163 100 3RV23 11-1KC10 0.320 3RV23 11-1KC20 0.30 16 7. Without 208 3RV23 11-4AC10 0.330 3RV23 11-4AC20 0.360 Size S0 16 7. Without 208 3RV23 21-4AC10 0.340 3RV23 21-4AC20 0.390 20 7. Without 260 3RV23 21-4BC10 0.330 3RV23 21-4BC20 0.390 22 11 Without 286 3RV23 21-4CC10 0.330 3RV23 21-4CC20 0.390 2 11 Without 32 3RV23 21-4DC10 0.340 3RV23 21-4DC20 0.390 28 1 Without 364 3RV23 21-4NC10 0.30 3RV23 21-4NC20 0.400 32 1 Without 400 3RV23 21-4EC10 0.30 3RV23 21-4EC20 0.400 36 18. Without 432 20 3RV23 21-4PC10 0.001 -- 40 18. Without 480 20 3RV23 21-4FC10 0.001 -- 1) Guide value for 4-pole standard motors at AC 0 Hz 400 V. Select MSP by motor full load amps. kw ratings for reference only. 2) For overload protection of the motors, appropriate overload relays must be used. Auxiliary switches can be ordered separately (see "Mountable accessories"). Spring-type terminals I n I cu Order No. Order No. /1

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Motor Starter Protectors For transformer protection Selection and ordering data CLASS 10, without auxiliary switches Motor starter protectors for the protection of transformers with high inrush current 3RV24 11-0AA10 3RV24 11-0AA20 3RV24 21-4AA10 3RV24 21-4AA20 Rated current Setting range Thermal overload releases Instantaneous overcurrent releases Auxiliary switches can be ordered separately (see "Mountable accessories"). Short-circuit breaking capacity at 480 V AC Short-circuit breaking capacity at 600 V AC Screw terminals Spring-type terminals I n I cu Order No. Order No. A A A ka ka kg kg Size S00 0.16 0.11... 0.16 3.3 6 30 3RV24 11-0AA10 0.260 3RV24 11-0AA20 0.290 0.2 0.14... 0.2 4.2 6 30 3RV24 11-0BA10 0.260 3RV24 11-0BA20 0.290 0.2 0.18... 0.2.2 6 30 3RV24 11-0CA10 0.260 3RV24 11-0CA20 0.290 0.32 0.22... 0.32 6. 6 30 3RV24 11-0DA10 0.260 3RV24 11-0DA20 0.290 0.4 0.28... 0.4 8.2 6 30 3RV24 11-0EA10 0.260 3RV24 11-0EA20 0.290 0. 0.3... 0. 10 6 30 3RV24 11-0FA10 0.260 3RV24 11-0FA20 0.290 0.63 0.4... 0.63 13 6 30 3RV24 11-0GA10 0.260 3RV24 11-0GA20 0.290 0.8 0.... 0.8 16 6 30 3RV24 11-0HA10 0.320 3RV24 11-0HA20 0.30 1 0.7... 1 21 6 30 3RV24 11-0JA10 0.320 3RV24 11-0JA20 0.30 1.2 0.9... 1.2 26 6 30 3RV24 11-0KA10 0.320 3RV24 11-0KA20 0.30 1.6 1.1... 1.6 33 6 30 3RV24 11-1AA10 0.320 3RV24 11-1AA20 0.30 2 1.4... 2 42 6 30 3RV24 11-1BA10 0.320 3RV24 11-1BA20 0.30 2. 1.8... 2. 2 6 30 3RV24 11-1CA10 0.320 3RV24 11-1CA20 0.30 3.2 2.2... 3.2 6 6 30 3RV24 11-1DA10 0.330 3RV24 11-1DA20 0.360 4 2.8... 4 82 6 30 3RV24 11-1EA10 0.330 3RV24 11-1EA20 0.30 3.... 104 6 30 3RV24 11-1FA10 0.330 3RV24 11-1FA20 0.360 6.3 4.... 6.3 130 6 30 3RV24 11-1GA10 0.330 3RV24 11-1GA20 0.360 8.... 8 163 6 30 3RV24 11-1HA10 0.320 3RV24 11-1HA20 0.30 10 7... 10 208 6 30 3RV24 11-1JA10 0.330 3RV24 11-1JA20 0.360 12. 9... 12. 260 6 30 3RV24 11-1KA10 0.330 3RV24 11-1KA20 0.360 16 11... 16 286 6 -- 3RV24 11-4AA10 0.330 3RV24 11-4AA20 0.360 Size S0 16 11... 16 286 6 -- 3RV24 21-4AA10 0.340 3RV24 21-4AA20 0.390 20 14... 20 32 6 -- 3RV24 21-4BA10 0.320 3RV24 21-4BA20 0.380 22 17... 22 364 6 -- 3RV24 21-4CA10 0.30 3RV24 21-4CA20 0.400 2 20... 2 400 6 -- 3RV24 21-4DA10 0.30 3RV24 21-4DA20 0.410 /16

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Selection and ordering data Without auxiliary switches Circuit breakers for system protection of motor 3) and non-motor loads according to UL/CSA For system protection according to UL 489/CSA C22.2 No. -02 3RV27 11-0AD10 Rated current 1) Thermal overload releases (non-adjustable) Instantaneous overcurrent release 1) Rated value 100 % according to UL 489 and IEC 60947-2 ("100 % rated breaker"). 2) Values for 600 Y/347 V AC can be found in the Technical Specifications under "Permissible rated data of devices approved for North America (UL/CSA)" --> "3RV27 and 3RV28 motor starter protectors as circuit breakers", see note on Technical Information on pages /1 and /2. 3) Requires use of supplemental overload protection for motor applications. Short-circuit breaking capacity at 480 Y/347 V AC 2) Short-circuit breaking capacity at 600 Y/347 V AC 2) I 1) n I bc Order No. Screw terminals A A A ka ka kg Size S00 0.16 0.16 2.1 6 10 3RV27 11-0AD10 0.390 0.2 0.2 2.6 6 10 3RV27 11-0BD10 0.390 0.2 0.2 3.3 6 10 3RV27 11-0CD10 0.390 0.32 0.32 4.2 6 10 3RV27 11-0DD10 0.390 0.4 0.4.2 6 10 3RV27 11-0ED10 0.390 0. 0. 6. 6 10 3RV27 11-0FD10 0.390 0.63 0.63 8.2 6 10 3RV27 11-0GD10 0.390 0.8 0.8 10 6 10 3RV27 11-0HD10 0.390 1 1 13 6 10 3RV27 11-0JD10 0.40 1.2 1.2 16 6 10 3RV27 11-0KD10 0.40 1.6 1.6 21 6 10 3RV27 11-1AD10 0.460 2 2 26 6 10 3RV27 11-1BD10 0.460 2. 2. 33 6 10 3RV27 11-1CD10 0.460 3.2 3.2 42 6 10 3RV27 11-1DD10 0.460 4 4 2 6 -- 3RV27 11-1ED10 0.40 6 6 -- 3RV27 11-1FD10 0.460 6.3 6.3 82 6 -- 3RV27 11-1GD10 0.460 8 8 104 6 -- 3RV27 11-1HD10 0.460 10 10 130 6 -- 3RV27 11-1JD10 0.460 12. 12. 163 6 -- 3RV27 11-1KD10 0.460 1 1 208 6 -- 3RV27 11-4AD10 0.470 Lateral and transverse auxiliary switches can be ordered separately (see "Mountable accessories"). /17

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A For transformer protection according to UL 489/CSA C22.2 No. -02 Selection and ordering data Without auxiliary switches Circuit breakers for system and transformer protection according to UL/CSA, specially designed for transformers with high inrush current 3RV28 11-0AD10 Rated current 1) I n 1) Thermal overload releases (non-adjustable) Instantaneous overcurrent release Short-circuit breaking capacity at 480 Y/277 V AC I bc Short-circuit breaking capacity @ 600 Y/347 V AC Screw terminals Order No. A A A ka ka kg Size S00 0.16 0.16 3.3 6 10 3RV28 11-0AD10 0.390 0.2 0.2 4.2 6 10 3RV28 11-0BD10 0.390 0.2 0.2.2 6 10 3RV28 11-0CD10 0.390 0.32 0.32 6. 6 10 3RV28 11-0DD10 0.390 0.4 0.4 8.2 6 10 3RV28 11-0ED10 0.390 0. 0. 10 6 10 3RV28 11-0FD10 0.390 0.63 0.63 13 6 10 3RV28 11-0GD10 0.400 0.8 0.8 16 6 10 3RV28 11-0HD10 0.40 1 1 21 6 10 3RV28 11-0JD10 0.40 1.2 1.2 26 6 10 3RV28 11-0KD10 0.460 1.6 1.6 33 6 10 3RV28 11-1AD10 0.460 2 2 42 6 10 3RV28 11-1BD10 0.460 2. 2. 2 6 10 3RV28 11-1CD10 0.460 3.2 3.2 6 6 -- 3RV28 11-1DD10 0.460 4 4 82 6 -- 3RV28 11-1ED10 0.460 104 6 -- 3RV28 11-1FD10 0.460 6.3 6.3 130 6 -- 3RV28 11-1GD10 0.460 8 8 163 6 -- 3RV28 11-1HD10 0.460 10 10 208 6 -- 3RV28 11-1JD10 0.460 12. 12. 260 6 -- 3RV28 11-1KD10 0.460 1 1 286 6 -- 3RV28 11-4AD10 0.470 1) Rated value 100 % according to UL 489 and IEC 60947-2 ("100 % rated breaker"). Lateral and transverse auxiliary switches can be ordered separately (see "Mountable accessories"). /18

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Overview Mountable accessories Mounting location and function The 3RV2 motor starter protectors have three main contact elements. In order to achieve maximum flexibility, auxiliary switches, signaling switches, auxiliary releases, and isolator modules can be supplied separately. These components can be fitted on the motor starter protectors without using tools. An overview graphic can be found on page /6. Front side Note: A maximum of 4 auxiliary contacts with auxiliary switches can be attached per motor starter protector. Left-hand side Notes: A maximum of 4 auxiliary contacts with auxiliary switches can be attached per motor starter protector. Auxiliary switches (2 contacts) and signal switches can be mounted separately or together. The signaling switch cannot be used for the 3RV27 and 3RV28 motor starter protectors/ circuit breakers. Right-hand side Notes: One auxiliary release can be mounted per motor starter protector. Accessories cannot be mounted at the right-hand side of the 3RV21 motor starter protectors for motor protection with overload relay function. Transverse auxiliary switch, solid-state compatible transverse auxiliary switch 1 NO + 1 NC or 2 NO or 1 CO Lateral auxiliary switches (2 contacts) 1 NO + 1 NC or 2 NO or 2 NC Lateral auxiliary switches (4 contacts) 2 NO + 2 NC Signaling switch Tripping 1 NO + 1 NC Short-circuit 1 NO + 1 NC Auxiliary releases Shunt releases or Undervoltage releases or Undervoltage releases with leading auxiliary contacts 2 NO Top Isolator modules Notes: The isolator module cannot be used for the 3RV27 and 3RV28 motor starter protectors/circuit breakers. The isolator module covers the terminal screws of the transverse auxiliary switch. If the isolator module is used, we therefore recommend that either the lateral auxiliary switches be fitted or that the isolator module not be mounted until the auxiliary switch has been wired. An auxiliary switch block can be inserted transversely on the front. The overall width of the motor starter protectors remains unchanged. One of the three lateral auxiliary switches can be mounted on the left side per motor starter protector. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector. The overall width of the lateral auxiliary switch with 2 contacts is 9 mm. One lateral auxiliary switch with four contacts can be mounted on the left side per motor starter protector. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector. The overall width of the lateral auxiliary switch with 4 contacts is 18 mm. One signaling switch can be mounted on the left side of each motor starter protector. The signaling switch has two contact systems. One contact system always signals tripping irrespective of whether this was caused by a short-circuit, an overload or an auxiliary release. The other contact system only switches in the event of a short-circuit. There is no signaling as a result of switching off with the handle. In order to be able to switch on the motor starter protector again after a short-circuit, the signaling switch must be reset manually after the error cause has been eliminated. The overall width of the signaling switch is 18 mm. For remote-controlled tripping of the motor starter protector. The release coil should only be energized for short periods (see schematics). Trips the motor starter protector when the voltage is interrupted and prevents the motor from being restarted accidentally when the voltage is restored. Used for remote-controlled tripping of the motor starter protector. Particularly suitable for EMERGENCY-STOP disconnection by way of the corresponding EMERGENCY-STOP pushbutton according to EN 60204-1 (VDE 0113). Function and use as for the undervoltage release without leading auxiliary contacts, but with the following additional function: the auxiliary contacts will open in switch position OFF to deenergize the coil of the undervoltage release, thus interrupting energy consumption. In the "tripped" position, these auxiliary contacts are not guaranteed to open. The leading contacts permit the motor starter protector to reclose. The overall width of the auxiliary release is 18 mm. Isolator modules can be mounted to the upper terminal end of the motor starter protectors. The supply cable is connected to the motor starter protector through the isolator module. The plug can only be unplugged when the motor starter protector is open and isolates all 3 poles of the motor starter protector from the network. The shock-protected isolation point is clearly visible and secured with a padlock to prevent reinsertion of the plug. For a complete overview of which accessories can be used for the various motor starter protectors see page /2. /19

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Mountable accessories Selection and ordering data Auxiliary switches 1) 3RV29 01-1E 3RV29 01-2E 3RV29 01-1G Version For motor starter protectors Size Screw terminals Order No. kg Spring-type terminals Order No. Transverse auxiliary switches for front mounting 1 CO S00, S0 3RV29 01-1D 0.014 -- 1 NO + 1 NC 3) 3RV29 01-1E 0.016 3RV29 01-2E 0.016 2 NO 3RV29 01-1F 0.017 3RV29 01-2F 0.017 Solid-state compatible transverse auxiliary switches for mounting on the front, for operation in dusty atmosphere and in solid-state circuits with low operating currents 1 CO S00, S0 3RV29 01-1G 0.01 -- Covers for transverse auxiliary switch S00, S0 3RV29 01-0H 0.001 -- kg 3RV29 01-0H Lateral auxiliary switches mountable on the left 1 NO + 1 NC 3) S00, S0 3RV29 01-1A 0.036 3RV29 01-2A 0.03 2 NO 3RV29 01-1B 0.037 3RV29 01-2B 0.03 2 NC 3RV29 01-1C 0.037 3RV29 01-2C 0.03 2 NO + 2 NC 3RV29 01-1J 0.066 -- 3RV29 01-3RV29 01-1A 2A Signaling switches 2) Signaling switches 3) One signaling switch can be mounted on the left per motor starter protector. Separate tripped and short-circuit alarms, 1 NO + 1 NC each S0 3RV29 21-1M 0.068 3RV29 21-2M 0.070 3RV29 21-3RV29 21-1M 2M Isolator modules 2) Isolator modules Visible isolating distance for isolating individual motor starter protectors from the network, lockable in disconnected position. S0, S00 3RV29 28-1A 0.132 -- 3RV29 28-1A with padlock 1) One transverse auxiliary switch and one lateral auxiliary switch can be attached per motor starter protector. The lateral auxiliary switch with 2 NO + 2 NC is used without a transverse auxiliary switch. 2) This accessory cannot be used for the 3RV27 and 3RV28 motor starter protectors. 3) The 3RV29 auxiliary and signaling switches with 1 NO + 1 NC are also available with ring lug terminal connection. The Order No. must be changed in the 8th position to "4": e. g. 3RV29 01-4E. /20 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Mountable accessories 3RV29 02-1AV0 3RV29 02-2AV0 3RV29 22-1CP0 3RV29 02-2DB0 Rated control supply voltage U s AC AC AC AC/DC DC 0 Hz 60 Hz 0/60 Hz 100 % ON period 1) For motor starter protectors Screw terminals Spring-type terminals 0/60 Hz, DC s ON period 2) Order No. Order No. V V V V V Size kg kg Auxiliary releases 3) Undervoltage releases -- -- -- -- 24 S00, S0 3RV29 02-1AB4 0.121 -- 24 -- -- -- -- S00, S0 3RV29 02-1AB0 0.118 -- 110 120 -- -- -- S00, S0 3RV29 02-1AF0 0.117 -- -- 208 -- -- -- S00, S0 3RV29 02-1AM1 0.111 -- 230 240 -- -- -- S00, S0 4) 3RV29 02-1AP0 0.110 3RV29 02-2AP0 0.112 400 440 -- -- -- S00, S0 4) 3RV29 02-1AV0 0.112 3RV29 02-2AV0 0.110 41 480 -- -- -- S00, S0 3RV29 02-1AV1 0.114 -- 00 600 -- -- -- S00, S0 3RV29 02-1AS0 0.111 -- Undervoltage releases with leading auxiliary contacts 2 NO 230 240 -- -- -- S00, S0 3RV29 22-1CP0 0.122 3RV29 22-2CP0 0.119 400 440 -- -- -- S00, S0 3RV29 22-1CV0 0.121 3RV29 22-2CV0 0.118 41 480 -- -- -- S00, S0 4) 3RV29 22-1CV1 0.121 3RV29 22-2CV1 0.118 Shunt releases -- -- 20... 24 20... 70 -- S00, S0 3RV29 02-1DB0 0.117 3RV29 02-2DB0 0.116 4) -- -- 90... 110 70... 190 -- S00, S0 3RV29 02-1DF0 0.119 3RV29 02-2DF0 0.11 -- -- 210... 240 190... 330 -- S00, S0 4) 3RV29 02-1DP0 0.114 3RV29 02-2DP0 0.112 -- -- 30... 41 330... 00 -- S00, S0 3RV29 02-1DV0 0.111 -- -- -- 00 00 -- S00, S0 3RV29 02-1DS0 0.110 -- 1) The voltage range is valid for 100 % (infinite) ON period. The response voltage lies at 0.9 of the lower limit of the voltage range. 2) The voltage range is valid for s ON period at AC 0/60Hz and DC. The response voltage lies at 0.8 of the lower limit of the voltage range. 3) One auxiliary release can be mounted on the right per motor starter protector (does not apply to 3RV21 motor starter protectors with overload relay function). 4) The 3RV29 auxiliary releases are also available with ring lug terminal connection. The Order No. must be changed in the 8th position to "4": e. g. 3RV29 02-4AP0. Illustrations are approximate /21

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Busbar accessories Insulated three-phase busbar systems 8US Fast Bus busbar adapters for 60 mm systems Three-phase busbar systems provide an easy, time-saving and clearly arranged means of feeding 3RV2 motor starter protectors with screw terminals. They can be used for the different types of motor starter protector up to 32 A. The 3RV19 1 three-phase busbar systems are generally unsuitable for the 3RV21 motor starter protectors for motor protection with overload relay function and for the 3RV27 and 3RV28 circuit breakers according to UL 489 / CSA C22.2 No.-02. The motor starter protectors are mounted directly with the aid of busbar adapters on busbar systems with 60 mm center-tocenter clearance in order to save space and to reduce infeed times and costs. The busbars are suitable for between 2 and circuit breakers/ motor starter protectors. However, any kind of extension is possible by clamping the tags of an additional busbar (rotated by 180 ) underneath the terminals of the respective last motor starter protector. The motor starter protectors are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. A combination of motor starter protectors of sizes S00 and S0 is possible. The motor starter protectors are supplied by appropriate feeder terminals. The busbar adapters for busbar systems with 60 mm center-tocenter clearance are suitable for copper busbars with a width of 12 to 30 mm. The busbars can be mm or 10 mm thick. Further busbar adapters for snap-mounting direct-on-line starters and reversing starters as well as additional accessories such as line terminals and outgoing terminals, flat copper profile, etc., can be found in the Controls catalog, Chapter "8US Fast Bus Busbar Systems". 3RV29 2-AB 3RV19 1-1CB 3RV19 1-6AB Three-phase busbar system size S00/S0 The three-phase busbar systems are finger-safe. They are designed for any short-circuit stress which can occur at the output side of connected motor starter protectors. The three-phase busbar systems can also be used to construct "Type E Starters" according to UL/CSA. Special feeder terminals must be used for this purpose, however (see "Selection and ordering data"). /22 NSB0_02080 NSB0_02079 3RV29 1-B SIRIUS motor starters with busbar adapters snapped onto busbars

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Selection and ordering data Modular spacing Number of motor starter protectors that can be connected Without lateral accessories Incl. lateral auxiliary switch Incl. auxiliary release Rated current I n at 690 V For motor starter protector Order No. Busbar accessories mm A Size kg Three-phase busbars 1)2) 3RV19 1-1AB 3RV19 1-1BB 3RV19 1-1CB For feeding several motor starter protectors with screw terminals, mounted side by side on standard mounting rails, insulated, with touch protection. 4 2 -- -- 63 S00, S0 1) 3RV19 1-1AB 0.044 3 S00, S0 1) 3RV19 1-1BB 0.071 4 S00, S0 1) 3RV19 1-1CB 0.099 S00, S0 1) 3RV19 1-1DB 0.124 -- 2 -- 63 S00, S0 1) 3RV19 1-2AB 0.048 3 S00, S0 1) 3RV19 1-2BB 0.079 4 S00, S0 1) 3RV19 1-2CB 0.111 S00, S0 1) 3RV19 1-2DB 0.140 63 -- -- 2 63 S00, S0 1) 3RV19 1-3AB 0.02 4 S00, S0 1) 3RV19 1-3CB 0.120 3RV19 1-1DB 1) Not suitable for 3RV21 motor starter protectors for motor protection with overload relay function and for 3RV27 and 3RV28 motor starter protectors/ circuit breakers according to UL 489 / CSA C22.2 No.-02. 2) Approved up to 32 A. Conductor cross-section Solid or stranded Finely stranded with end sleeve AWG cables, solid or stranded Tightening torque For motor starter protector mm² mm² AWG Nm Size kg Three-phase feeder terminals 3RV29 2-AB Connection from top Order No. 2.... 16 2.... 16 10... 4 3... 4 S00, S0 3RV29 2-AB 0.043 Connection from below 1) 2.... 16 2.... 16 10... 4 Input: 4, Output: 2... 2. S00, S0 3RV29 1-B 0.093 3RV29 1-B Three-phase feeder terminals for constructing "Type E Starters" Connection from top 2.... 16 2.... 16 10... 4 3... 4 S00, S0 3RV29 2-EB 0.044 3RV29 2-EB 1) This terminal is connected in place of a switch, please take the space requirement into account. Version Covers for connection tags Touch protection for empty positions For motor starter protector Size Order No. PU (UNIT, SET, M) PS* S00, S0 3RV19 1-6AB 1 10 units 0.003 kg 3RV19 1-6AB * You can order this quantity or a multiple thereof. Illustrations are approximate /23

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Busbar accessories Busbar adapters 8US12 1-DS10 8US12 1-DT11 8US12 0-AS10 8US12 0-AT10 For motor starter protector Rated current Connecting cable Adapter length Adapter width Rated voltage Order No. PU (UNIT, SET, M) Size A AWG mm mm V kg Busbar adapters for 60 mm systems For flat copper profiles according to DIN 46433 Width: 12 mm and 30 mm Thickness: mm and 10 mm also for T and double-t special profiles For motor starter protectors with screw terminals Screw terminals PS* S00 16 12 200 4 690 8US12 1-DS10 1 1 unit 0.183 S0 32 10 260 4 690 8US12 1-NT10 1 1 unit 0.183 For motor starter protectors with spring-type terminals Spring-type terminals S00 16 12 260 4 690 8US12 1-DT11 1 1 unit 0.183 S0 32 10 260 4 690 8US12 1-NT11 1 1 unit 0.183 Accessories Device holders -- -- 200 4 -- 8US12 0-AS10 1 1 unit 0.183 For lateral attachment to busbar adapters -- -- 260 4 -- 8US12 0-AT10 1 1 unit 0.183 Side modules For widening of busbar adapters -- -- 200 9 -- 8US19 98-2BJ10 1 1 unit 0.023 Spacers Fixes the motor starter onto the busbar adapter Vibration and shock kits For high vibration and shock loads -- -- -- -- -- 8US19 98-1BA10 1 10 units 0.183 -- -- -- -- -- 8US19 98-1CA10 1 1 unit 0.183 For additional busbar adapters see the Controls catalog, Chapter "Fast Bus". * You can order this quantity or a multiple thereof. /24 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories 3RV29 infeed system Overview The 3RV29 infeed system is a convenient means of energy supply and distribution for a group of several motor starter protectors or complete motor starters with a screw or springtype connection in sizes S00 and S0 (exception: this system cannot be used for the 3RV21, 3RV27 and 3RV28 motor starter protectors/circuit breakers). The electrical connection between the three-phase busbars and the motor starter protectors is implemented through plug-in connectors. The complete system can be mounted on a TH 3 standard mounting rail to EN 6071 and can be expanded as required up to a maximum current carrying capacity of 63 A. The system is mounted extremely quickly and easily thanks to the simple plug-in technique. Thanks to the lateral infeed, the system also saves space in the control cabinet. The additional overall height required for the infeed unit is only 30 mm. The alternative infeed possibilities on each side offer a high degree of flexibility for configuring the control cabinet: Infeed on lefthand or right-hand side as well as infeed on one side and outfeed on the other side to supply further loads are all possible. A terminal block with spring-type connections in combination with a standard mounting rail enables the integration of not only SIRIUS motor starter protectors but also single-phase, 2-phase and 3-phase components such as SY miniature circuit breakers or SIRIUS relay components. The system is based on a basic module complete with a lateral incoming unit (three-phase busbar with infeed). This infeed with spring-type terminals is mounted on the right or left depending on the version and can be supplied with a maximum conductor cross-section of 2 mm2 (with end sleeve). A basic module has two sockets onto each of which a motor starter protector can be snapped. Expansion modules are available for extending the system (three-phase busbars for system expansion). The individual modules are connected through an expansion plug. 3b 3a 1 2 4 7 NSB0_02078 6 3-phase busbar with infeed 3-phase busbar for system expansion 3a Expansion plug 3b Extra-wide expansion plug 1 4 2 6 7 End cover Plug-in connector Contactor base Terminal block 3RV29 infeed system /2

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories 3RV29 infeed system $ Three-phase busbars with infeed A three-phase busbar with infeed unit is required for connecting the energy supply. This module comprises one infeed module and 2 sockets which each accept one motor starter protector. A choice of two versions with infeed on the left or right is available. The infeed is connected using spring-type terminals. The spring-type terminals permit conductor cross-sections of up to 2 mm 2 with end sleeves. An end cover is supplied with each module. % Three-phase busbars for system expansion The three-phase busbars for system expansion allow the system to be expanded. There is a choice of modules with 2 or 3 sockets. The system can be expanded as required up to a maximum current carrying capacity of 63 A. An expansion plug is supplied with each module. &a Expansion plug The expansion plug is used for electrical connection of adjacent three-phase busbars. The current carrying capacity of this plug equals 63 A. One expansion plug is supplied with each threephase busbar for system expansion. Additional expansion plugs are therefore only required as spare parts. &b Extra-wide expansion plug The wide expansion plug makes the electrical connection between two three-phase busbars, thus performing the same function as the 3RV29 17-BA00 expansion plug; the electrical characteristics (e.g. a current carrying capacity of 63 A) are identical. The 3RV29 17-E expansion plug is 10 mm wider than the 3RV29 17-BA00 expansion plug, hence in the plugged state there is a distance of 10 mm between the connected threephase busbars. This distance can be used to lay the auxiliary current and control current wiring ("wiring duct"). The motor starter protector and contactor can be wired from underneath, which means that the complete cable duct above the system can be omitted. ( End cover The end cover is used to cover the three-phase busbar at the open end of the system. This cover is therefore only required once for each system. An end cover is supplied with each threephase busbar system with infeed. Further end covers are therefore only required as spare parts. * Contactor base Motor starters can be assembled in the system using the contactor base. The contactor bases are suitable for contactors sizes S00 and S0 with spring-type and screw terminals and are simply snapped onto the three-phase busbars. Direct-on-line starters and reversing starters are possible. One contactor base is required for direct-on-line starters and two are required for reversing starters. To assemble motor starters for reversing starters, the contactor bases can be arranged alongside each other (90 mm overall width). In this case the mechanical interlocking of the contactors is possible. The contactor bases are also suitable for soft starters size S00 and S0 with screw connection. The infeed system is designed for mounting on a 3 mm standard mounting rail with 7. mm overall depth. This standard mounting rail gives the contactor base a stable mounting surface to sit on. If standard mounting rails with a depth of 1 mm are used, the spacer connected to the bottom of the contactor base must be knocked out and plugged into the mating piece that is also on the underside. Then the contactor base also has a stable mounting surface. When standard mounting rails with a depth of 7. mm are used, the spacer has no function and can be removed. The link modules are used for direct start motor starters, in which case the use of a contactor base is not absolutely necessary. Motor starter protector and contactor assemblies can then be directly snapped onto the sockets of the three-phase busbars. For starters of size S00 and S0, the corresponding 3RA19 21-1..., 3RA29 11-2..., 3RA29 21-1... or 3RA29 21-2... link modules should generally be used. + Terminal block The 3RV29 17-D terminal block enables the integration of not only SIRIUS motor starter protectors but also single-phase, 2-phase and 3-phase components. Using the terminal block the 3 phases can be fed out of the system; which means that singlephase loads can also be integrated in the system. The terminal block is plugged into the slot of the expansion plug and thus enables outfeeding from the middle or end of the infeed system. The terminal block can be rotated through 180 and be locked to the support modules of the infeed system. The 3RV19 17-7B 4 mm standard mounting rail for screwing onto the support plate is available in addition in order to be able to plug the single-phase, 2-phase and 3-phase components onto the infeed system. ) Plug-in connector The plug-in connector is used for the electrical connection between the three-phase busbar and the 3RV2 motor starter protector. These plug-in connectors are available in versions for screw or spring-type terminals. /26

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Selection and ordering data Three-phase busbars with infeed 3-phase busbars with infeed incl. end cover 3RV29 17-6A Type Version For 3RV20, 3RV23, 3RV24 motor starter protectors For 2 motor starter protectors with screw connection or spring-type terminals With infeed on the left With infeed on the right Order No. PU (UNIT, SET, M) 3RV29 infeed system PS* Size kg S00, S0 3RV29 17-1A 1 1 unit 0.369 S00, S0 3RV29 17-1E 1 1 unit 0.369 3RV29 17-1A Three-phase busbars for system expansion 3RV29 17-4A Plug-in connectors Three-phase busbars incl. 3RV29 17- BA00 expansion plug Plug-in connectors to make contact with the motor starter protectors For motor starter protectors with screw connection or spring-type terminals For 2 motor starter protectors For 3 motor starter protectors For spring-type terminals - Single-unit packaging - Multi-unit packaging S00, S0 3RV29 17-4A 1 1 unit 0.229 S00, S0 3RV29 17-4B 1 1 unit 0.328 Spring-type terminals S00 1) 3RV29 17-AA00 1 1 unit 0.046 S0 2) 3RV29 27-AA00 1 1 unit 0.09 S00 1) 3RV29 17-A 1 10 units 0.046 S0 2) 3RV29 27-A 1 10 units 0.09 3RV29 17-AA00 3RV29 17-CA00 For screw terminals - Single-unit packaging - Multi-unit packaging Screw terminals S00 1) 3RV29 17-CA00 1 1 unit 0.029 S0 2) 3RV19 27-AA00 1 1 unit 0.040 S00 1) 3RV29 17-C 1 10 units 0.029 S0 2) 3RV19 27-A 1 10 units 0.036 Contactor bases Type Version For contactors Contactor bases for mounting direct-on-line or reversing starters Single-unit packaging Order No. PU (UNIT, SET, M) PS* Size kg S00, S0 3RV29 27-7AA00 1 1 unit 0.00 3RV29 27-7AA00 1) I > 14 A, note derating; see the system manual "SIRIUS Innovations", Chapter "Motor Starter Protectors". 2) I > 16 A, note derating; see the system manual "SIRIUS Innovations", Chapter "Motor Starter Protectors". * You can order this quantity or a multiple thereof. Illustrations are approximate /27

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories 3RV29 infeed system Terminal blocks Type Version Order No. PU (UNIT, SET, M) Terminal blocks For integration of single-phase, two-phase and three-phase components PS* Single-unit packaging 3RV29 17-D 1 1 unit 0.049 kg 3RV29 17-D 4 mm standard mounting rails 4 mm standard mounting rails for mounting onto bus bar adapters Single-unit packaging 3RV19 17-7B 1 1 unit 0.261 3RV19 17-7B Extra-wide expansion plugs Extra-wide expansion plugs as accessory Single-unit packaging 3RV29 17-E 1 1 unit 0.037 3RV29 17-E Expansion plugs Expansion plugs 1) as spare part Single-unit packaging 3RV29 17-BA00 1 1 unit 0.026 3RV29 17-BA00 End covers End covers 2) as spare part Multi-unit packaging 3RV29 17-6A 1 10 units 0.00 3RV29 17-6A 1) The expansion plug is included in the scope of supply of the 3RV29 17-4 three-phase busbars for system expansion. 2) The end cover is included in the scope of supply of the 3RV29 17-1 threephase busbars with infeed system. * You can order this quantity or a multiple thereof. /28 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Rotary operating mechanisms Overview Door-coupling rotary operating mechanisms Motor starter protectors with a rotary operating mechanism can be mounted in a control cabinet and operated externally by means of a door-coupling rotary operating mechanism. When the cabinet door with motor starter protector is closed, the operating mechanism is coupled. When the motor starter protector closes, the coupling is locked which prevents the door from being opened unintentionally. This interlock can be disengaged by the maintenance personnel. In the OPEN position, the rotary operating mechanism can be secured against reclosing with up to 3 padlocks. Inadvertent opening of the door is not possible in this case either. NSB01079a NSB01078 3RV29 26-2B door-coupling rotary operating mechanism for arduous conditions 3RV29 26-0K door-coupling rotary operating mechanism Selection and ordering data Version Color of handle Door-coupling rotary operating mechanisms 3RV29 26-0B Version of extension shaft For motor starter protector Order No. mm Size kg The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a 130/330 mm long extension shaft (6 mm x 6 mm). The door-coupling rotary operating mechanisms are designed to degree of protection IP6. The door locking device prevents accidental opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked with up to 3 padlocks. Door-coupling rotary operating mechanisms EMER- GENCY- STOP doorcoupling rotary operating mechanisms Black 130 S00, S0 3RV29 26-0B 0.111 330 S00, S0 3RV29 26-0K 0.324 Red/ Yellow Door-coupling rotary operating mechanisms for arduous conditions 3RV29 26-2B 130 S00, S0 3RV29 26-0C 0.110 330 S00, S0 3RV29 26-0L 0.316 The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm in length (8 mm x 8 mm), a spacer and two metal brackets, into which the motor starter protector is inserted. The door-coupling rotary operating mechanisms are designed to degree of protection IP6. The door interlocking reliably prevents opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked with up to 3 padlocks. Laterally mountable auxiliary releases and two-pole auxiliary switches can be used. The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60947-2. Door-coupling rotary operating mechanisms Gray 300 S00, S0 3RV29 26-2B 1.180 EMER- GENCY- STOP doorcoupling rotary operating mechanisms Red/ Yellow 300 S00, S0 3RV29 26-2C 1.188 Illustrations are approximate /29

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Mounting accessories Overview Accessories for "Self-Protected Combination Motor Controllers (Type E)" according to UL 08 The 3RV20 motor starter protectors are approved according to UL 08 as "Self-Protected Combination Motor Controllers (Type E)". This requires increased clearance and creepage distances (1 inch and 2 inches respectively) at the input side of the device, which are achieved by mounting terminal blocks. The 3RV29 28-1H terminal block is simply screwed onto the basic unit. 3RV29 28-1H terminal block Another way to obtain the increased clearance and creepage distances for Type E is to mount the 3RV29 28-1K phase barriers. Special three-phase feeder terminals are required for constructing "Type E Starters" with an insulated three-phase busbar system (see "Busbar Accessories"). Note: According to CSA, the terminal blocks and the phase barriers can be omitted when the device is used as a "Self-Protected Combination Motor Controller" (Type E). NSB0_01379b Link modules Starters can be easily assembled from single devices with the help of the link modules. The following table shows the various possible combinations for devices with screw connection or spring-type terminals. Combination device 3RV2 motor starter protectors Size 3RT2 contactors; 3RW30, 3RW40 soft starters; 3RF34 solidstate contactors Size Link modules Screw terminals Spring-type terminals Link modules for connecting switching devices to 3RV2 motor starter protectors 1) 3RT2 contactors with AC or DC coil 3RT2 contactors with AC coil 3RT2 contactors with DC coil 3RW30 soft starters 3RW30/3RW40 soft starters 3RF34 solidstate contactors S00 S00 3RA19 21-1DA00 S0 S00 -- S0 S0 3RA29 21-1AA00 S00 S0 -- S0 S0 3RA29 21-1BA00 S00 S0 -- S00 S00 3RA29 21-1BA00 S0 S00 -- S0 S0 3RA29 21-1BA00 S00 S0 -- S00/S0 S00 3RA29 21-1BA00 3RA29 11-2AA00 3RA29 21-2AA00 3RA29 21-2AA00 3RA29 11-2GA00 3RA29 21-2GA00 Hybrid link modules for connecting contactors with spring-type terminals to 3RV2 motor starter protectors with screw connection 1) 3RT2 contactors with AC or DC coil 3RT2 contactors with AC or DC coil S00 S00 3RA29 11-2FA00 S0 S0 3RA29 21-2FA00 Note: Link modules and hybrid link modules can be used up to max. 32 A. 1) Link modules and hybrid link modules cannot be used for 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors. -- -- -- Selection and ordering data Accessories Covers 3RV29 08-0P 3RV29 28-4AA00 Version Scale covers Sealable, for covering the set current scale Covers for devices with ring lug terminal connection (ensure finger-safety) Main current level For motor starter protector Size 3RV20, 3RV21, 3RV24: S00, S0 Order No. PU (UNIT, SET, M) PS* 3RV29 08-0P 1 10 units 0.100 Ring lug terminal connection 3RV20: 3RV29 28-4AA00 1 1 unit 0.010 For transverse auxiliary switches S00, S0 3RV29 08-4AA10 1 1 unit 0.010 kg 3RV29 08-4AA10 * You can order this quantity or a multiple thereof. /30 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Mounting accessories Fixing material Push-in lugs For screwing the motor starter protector onto mounting plates. For each motor starter protector, 2 units are required. 3RV29 28-0B Tools for opening spring-type terminals by hand Screwdrivers for all SIRIUS devices with spring-type terminals Length 200 mm, 3.0 mm x 0. mm, titanium gray/black, 3RA29 08-1A partially insulated Terminal blocks and phase barriers for "Self-Protected Combination Motor Controllers (Type E)" according to UL 08 3RV29 28-1H 3RV29 28-1K Version S00, S0 3RV29 28-0B 1 10 units 0.100 Spring-type terminals S00, S0 3RA29 08-1A 1 1 unit 0.04 Note: UL 08 demands 1-inch clearance and 2-inch creepage distance at line side for "Combination Motor Controller Type E". The following terminal blocks or phase barriers must be used in 3RV20 motor starter protectors. The terminal blocks or phase barriers cannot be used in combination with the 3RV19. three-phase busbars. For construction with three-phase busbars, see "Busbar accessories". Terminal blocks type E For extended clearance and creepage distances (1 and 2 inch) S00, S0 3RV29 28-1H 1 1 unit 0.06 Phase barriers For extended clearance and creepage distances (1 and 2 inch) For motor starter protector Size Order No. PU (UNIT, SET, M) S00, S0 3RV29 28-1K 1 1 unit 0.010 PS* kg Link modules Actuating voltage of contactor Link modules for motor starter protector to contactor 1) 3RA29 21-1AA00 3RA29 11-2AA00 1) The link modules for motor starter protector to contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors. 2) A spacer for height compensation on AC contactors size S0 is optionally available. Size Order No. PU 3RT2 3RV2 motor (UNIT, contactors starter SET, M) protectors Note: Link modules can be used up to max. 32 A. PS* For mechanical and electrical connection between Screw terminals motor starter protector and contactor with screw terminals Single-unit packaging AC/DC S00 S00/S0 3RA19 21-1DA00 1 1 unit 0.028 AC S0 S00/S0 3RA29 21-1AA00 1 1 unit 0.001 DC S0 S00/S0 3RA29 21-1BA00 1 1 unit 0.001 Multi-unit packaging AC/DC S00 S00/S0 3RA19 21-1D 1 10 units 0.021 AC S0 S00/S0 3RA29 21-1A 1 10 units 0.001 DC S0 S00/S0 3RA29 21-1B 1 10 units 0.001 For mechanical and electrical connection between motor starter protector and contactor with springtype terminals Single-unit packaging Spring-type terminals AC/DC S00 S00 3RA29 11-2AA00 1 1 unit 0.040 AC 2) S0 S0 3RA29 21-2AA00 1 1 unit 0.077 DC S0 S0 3RA29 21-2AA00 1 1 unit 0.077 Multi-unit packaging AC/DC S00 S00 3RA29 11-2A 1 10 units 0.400 AC 2) S0 S0 3RA29 21-2A 1 10 units 0.770 DC S0 S0 3RA29 21-2A 1 10 units 0.770 Spacers 2) for compensating the height on AC contactors Single-unit packaging S0 S0 3RA29 11-1CA00 1 1 unit 0.001 Multi-unit packaging S0 S0 3RA29 11-1C 1 units 0.001 kg * You can order this quantity or a multiple thereof. Illustrations are approximate /31

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Mounting accessories Size Order No. PU 3RW30, 3RW40 3RV2 (UNIT, soft starters; motor starter protectors SET, M) 3RF34 solid-state contactors Link modules for motor starter protector to soft starter 1) and motor starter protector to solid-state contactor 3RA29 21-1BA00 PS* Connection between motor starter protector and soft Screw terminals starter / solid-state contactor with screw terminals Single-unit packaging S00 S00/S0 3RA29 21-1BA00 1 1 unit 0.001 S0 S00/S0 3RA29 21-1BA00 1 1 unit 0.001 Multi-unit packaging S00 S00/S0 3RA29 21-1B 1 10 units 0.001 S0 S00/S0 3RA29 21-1B 1 10 units 0.001 Connection between motor starter protector and soft starter with spring-type terminals Spring-type terminals kg 3RA29 21-2GA00 1) Single-unit packaging S00 S00 3RA29 11-2GA00 1 1 unit 0.038 S0 S0 3RA29 21-2GA00 1 1 unit 0.072 Multi-unit packaging S00 S00 3RA29 11-2G 1 10 units 0.380 S0 S0 3RA29 21-2G 1 10 units 0.720 The link modules for motor starter protector to soft starter and for motor starter protector to solid-state contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors. Note: Link modules can be used up to max. 32 A. Actuating voltage of contactor Hybrid link modules for motor starter protector to contactor 1) Size Order No. PU 3RT2 3RV2 (UNIT, contactors motor SET, M) starter protectors PS* For mechanical and electrical connection between motor starter protector with screw terminals and contactor with spring-type terminals Single-unit packaging AC/DC S00 S00 3RA29 11-2FA00 1 1 unit 0.029 AC 2) /DC S0 S0 3RA29 21-2FA00 1 1 unit 0.06 kg 3RA29 11-2FA00 Multi-unit packaging AC/DC S00 S00 3RA29 11-2F 1 10 units 0.290 AC 2) /DC S0 S0 3RA29 21-2F 1 10 units 0.60 Spacers 2) for compensating the height on AC contactors Single-unit packaging S0 S0 3RA29 11-1CA00 1 1 unit 0.001 Multi-unit packaging S0 S0 3RA29 11-1C 1 units 0.001 3RA29 21-2FA00 1) The hybrid link modules for motor starter protector to contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors. 2) A spacer for height compensation on AC contactors size S0 is optionally available. Note: Hybrid link modules can be used up to max. 32 A. * You can order this quantity or a multiple thereof. /32 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures 1) For stand-alone installation of 3RV20 to 3RV24 motor starter protectors size S00 (I n max = 16 A) and S0 (I n max = 32 A), cast aluminum enclosures for surface mounting and molded-plastic enclosures for flush mounting are available in various dimensions. When installed in a molded-plastic enclosure, the motor starter protectors have a rated operational voltage U e of 00 V. The enclosures for surface mounting have the degree of protection IP; the enclosures for flush mounting also comply with the degree of protection IP at the front (the flush-mounted section complies with IP20). All enclosures are equipped with N and PE terminals. There are two knock-out cable entries for cable glands at the top and two at the bottom; also on the rear corresponding cable entries are scored. There is a knockout on the top of the enclosure for indicator lights that are available as accessories. The narrow enclosure can accommodate a motor starter protector without accessories, with transverse auxiliary switch and with lateral auxiliary switch. The installation of a motor starter protector with signalling switch is not intended. With the motor starter protectors size S00 and S0, the moldedplastic enclosures are equipped with a rotary operating mechanism. The enclosures can be supplied with either a black rotary operating mechanism or with an EMERGENCY-STOP rotary operating mechanism with a red/yellow handle. All rotary operating mechanisms can be locked in the OFF position with up to 3 padlocks. Front plates Motor starter protectors are frequently required to be actuated in any enclosure. Front plates equipped with a rotary operating mechanism for 3RV20 to 3RV24 motor starter protectors size S00 and S0 are available for this purpose. A holder for the motor starter protectors size S00 and S0, into which the motor starter protectors can be snapped, is available for the front plates. NSB0_02081 Enclosures for surface mounting NSB0_02083 NSB0_02082 Front plate (including holder) for sizes S00 and S0 Enclosures for flush mounting 1) Not CSA, for export only /33

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Selection and ordering data Version Degree of protection Integrated terminals Width For 3RV20 to 3RV24 motor starter protectors mm Size kg Molded-plastic enclosures for surface mounting 3RV19 23-1FA00 With rotary operating mechanism, lockable in 0 position With EMER- GENCY- STOP rotary operating mechanism, lockable in 0 position IP IP N and PE N and PE 4 (for switch + lateral auxiliary switch) 72 (for switch + lateral auxiliary switch + auxiliary release) 4 (for switch + lateral auxiliary switch) Cast aluminum enclosures for surface mounting 3RV19 23-1DA01 72 (for switch + lateral auxiliary switch + auxiliary release) With rotary operating mechanism, lockable in 0 position IP6 PE 1) 72 (for switch + lateral auxiliary switch + auxiliary release) With EMER- GENCY- STOP rotary operating mechanism, lockable in 0 position IP6 PE 1) 72 (for switch + lateral auxiliary switch + auxiliary release) Molded-plastic enclosure for flush mounting 3RV19 23-2DA00 With IP rotary operating mecha- side) (front nism, lockable in 0 position With EMER- GENCY- STOP rotary operating mechanism, lockable in 0 position IP (front side) N and PE N and PE 72 (for switch + lateral auxiliary switch + auxiliary release) 72 (for switch + lateral auxiliary switch + auxiliary release) Order No. S00, S0 3RV19 23-1CA00 0.332 S00, S0 3RV19 23-1DA00 0.381 S00, S0 3RV19 23-1FA00 0.329 S00, S0 3RV19 23-1GA00 0.372 S00, S0 3RV19 23-1DA01 1.01 S00, S0 3RV19 23-1GA01 1.008 S00, S0 3RV19 23-2DA00 0.426 S00, S0 3RV19 23-2GA00 0.417 1) If required, an additional N terminal can be mounted (e.g. 8WA1 011-1BG11). The enclosures listed on this page do not carry UL/CSA listings. /34 Illustrations are approximate

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Front plates 3RV19 23-4B + 3RV19 23-4G Version Molded-plastic front plates with rotary operating mechanism, lockable in 0 position For actuation of 3RV2 motor starter protectors in any enclosure. Molded-plastic front plates with EMERGENCY-STOP rotary operating mechanism, red/yellow, lockable in 0 position EMERGENCY-STOP actuation of 3RV2 motor starter protectors in any enclosure. Holders for front plates Holder is mounted on front plate, motor starter protector with and without accessories is snapped in. Degree of protection IP (front side) IP (front side) For 3RV20 to 3RV24 motor starter protectors Size Order No. S00, S0 3RV19 23-4B 0.124 S00, S0 3RV19 23-4E 0.124 -- S00, S0 3RV19 23-4G 0.188 kg Indicator lights Version Rated control supply voltage U s For 3RV20 to 3RV24 motor starter protectors Order No. V Size kg Indicator lights for all enclosures and front plates With glow lamp and colored lenses red, green, yellow, orange and clear 110... 120 S00, S0 3RV19 03-B 0.027 220... 240 3RV19 03-C 0.026 380... 41 3RV19 03-E 0.026 480... 00 3RV19 03-G 0.027 3RV19 03-B The front plates listed on this page do not carry UL/CSA listings. Illustrations are approximate /3

Overload Relays General data Overview Features 3RU21 3RB30/3RB31 Benefits General data Sizes S00, S0 S00, S0 Are coordinated with the dimensions, connections and technical characteristics of the other devices in the SIRIUS modular system (contactors, soft starters,...) Permit the mounting of slim and compact motor starters in widths of 4 mm (S00 and S0) Simplify configuration Seamless current range 0.11... 40 A 0.1... 40 A Allows easy and consistent configuration with one series of overload relays (for small to large loads) Protection functions Tripping in the event of overload Provides optimum inverse-time delayed protection of loads against excessive temperature rises due to overload Tripping in the event of phase unbalance Available -- Not available Provides optimum inverse-time delayed protection of loads against excessive temperature rises due to phase unbalance Tripping in the event of phase failure Minimizes heating of induction motors during phase failure Protection of single-phase loads -- Enables the protection of single-phase loads Tripping in the event of a ground fault -- Provides optimum protection of loads against highresistance short-circuits or ground faults due to moisture, (only 3RB31) by condensed water, damage to the insulation material, etc. Eliminates the need for additional special equipment. internal ground-fault detection (activatable) Saves space in the control cabinet Reduces wiring outlay and costs Features RESET function Allows manual or automatic resetting of the relay Remote RESET function (by means of separate module) (only 3RB31 with 24 V DC) Allows the remote resetting of the relay TEST function for auxiliary contacts Allows easy checking of the function and wiring TEST function for electronics -- Allows checking of the electronics Status display Displays the current operating state Integrated auxiliary contacts Allows the load to be switched off if necessary (1 NO + 1 NC) Can be used to output signals /36

Overload Relays General data Features 3RU21 3RB30/3RB31 Benefits Design of motor starters Short-circuit strength up to 100 ka at 690 V (in conjunction with the corresponding fuses or the corresponding motor starter protector) Available -- Not available Provides optimum protection of the loads and operating personnel in the event of short-circuits due to insulation faults or faulty switching operations Electrical and mechanical matching to 3RT2 contactors Simplifies configuration Reduces wiring outlay and costs Enables stand-alone installation as well as space-saving direct mounting Spring-type terminal connection system for main circuit Enables fast connections Permits vibration-resistant connections Enables maintenance-free connections Spring-type terminal connection system for auxiliary circuits Enables fast connections Permits vibration-resistant connections Enables maintenance-free connections Other features Temperature compensation Allows the use of the relays at high temperatures without derating Prevents premature tripping Allows compact installation of the control cabinet without distance between the devices/motor starters Simplifies configuration Enables space to be saved in the control cabinet High long-term stability Provides safe protection for the loads even after years of use in severe operating conditions Wide setting ranges -- (1:4) Reduce the number of variants Minimize the configuration outlay and costs Minimize storage overhead, storage costs, tied-up capital Trip class CLASS -- (only 3RB31) Enables solutions for very fast starting motors requiring special protection Trip classes > CLASS 10 -- Enable heavy starting solutions Low power loss -- Reduces power consumption and energy costs (up 98 % less power is used than for thermal overload relays) Minimizes temperature rises of the contactor and control cabinet in some cases this may eliminate the need for controlgear cabinet cooling Direct mounting to contactor saves space, even for high motor currents (i.e. no heat decoupling is required) Internal power supply -- 1) Eliminates the need for configuration and connecting an additional control circuit Variable adjustment of the trip classes (The required trip class can be adjusted by means of a rotary switch depending on the current start-up condition.) -- Reduces the number of variants (only 3RB31) Minimizes the configuring outlay and costs Minimizes storage overhead, storage costs, and tied-up capital 1) The SIRIUS 3RU21 thermal overload relays use a bimetal contactor and therefore do not require a control supply voltage. /37

Overload Relays General data Overload relays Current measurement Current range Contactors (type, size, rating in HP) 3RT20 1 3RT20 2 S00 S0 Type Type A 3//7./10 7./10/1/20/2 3RU21 thermal overload relays 1) 3RU21 1 Integrated 0.11 16 -- 3RU21 2 Integrated 1.8 40 -- 3RB30 1) solid-state overload relays 3RB30 1 Integrated 0.1 16 -- 3RB30 2 Integrated 0.1 40 -- 3RB21 1) solid-state overload relays 3RB31 1 Integrated 0.1 16 -- 3RB31 2 Integrated 0.1 40 -- Available -- Not available 1) "Technical Specifications" for use of the overload relays with trip class CLASS 20 can be found under "Short-circuit protection with fuses for motor starters", see the note on Technical Information on page /1. Connection methods Depending on the device version of the 3RU2 and 3RB3 overload relays, the terminals for screw, spring-type or ring lug terminal connection are configured for both the main and auxiliary circuit. Screw terminals Spring-type terminals Ring lug terminal connection These terminals are indicated in the corresponding tables by the symbols shown on orange backgrounds. /38

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Overview 1 2 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to these contactor using these pins. Stand-alone installation is possible as an alternative (in conjunction with a terminal bracket for stand-alone installation). Selector switch for manual/automatic RESET and RESET button: With this switch you can choose between manual and automatic RESET. A device set to manual RESET can be reset locally by pressing the RESET button. A remote RESET is possible using the RESET modules (accessories), which are independent of size. 3 Switch position indicator and TEST function of the wiring: Indicates a trip and enables the wiring test. 4 Motor current setting: Setting the device to the rated motor current is easy with the large rotary knob. STOP button: If the STOP button is pressed, the NC contact is opened. This switches off the contactor downstream. The NC contact is closed again when the button is released. 6 Supply terminals: Depending on the device version, the terminals for screw, spring-type or ring lug terminal connection are configured for the main and auxiliary circuit. A sealable transparent cover can be optionally mounted (accessory). It secures the motor current setting against adjustment. 3 4 6 The 3RU21 thermal overload relays up to 40 A have been designed for current-dependent protection of loads with normal starting (for "Function" see note on Technical Information on page /1) against excessive temperature rises due to overload or phase failure. An overload or phase failure results in an increase of the motor current beyond the set rated motor current. Via heating elements, this current rise heats up the bimetal strips inside the device which then bend and as a result trigger the auxiliary contacts by means of a tripping mechanism. The auxiliary contacts then switch off the load by means of a contactor. The switch-off time depends on the ratio between the tripping current and set current I e and is stored in the form of a long-term stable tripping characteristic (for "Characteristic Curves" see the note on Technical Information on page /1). The "tripped" status is signaled by means of a switch position indicator. Resetting takes place either manually or automatically after a recovery time has elapsed (for "Function" see note on Technical Information on page /1). The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable materials. They comply with all important worldwide standards and approvals. "Increased safety" type of protection EEx e according to ATEX directive 94/9/EC The 3RU21 thermal overload relays are suitable for the overload protection of explosion-proof motors with "increased safety" type of protection EEx e. The relays meet the requirements of EN 60079-7 (Electrical apparatus for areas subject to explosion hazards Increased safety "e"); see Chapter 9 "Appendix" --> "Standards and approvals" --> "Type overview of approved devices for explosion-protected areas (ATEX Explosion Protection)". EC type test certificate for Category (2) G/D has been submitted. More details on request. 3RU21 26-4FB00 thermal overload relays Benefits The most important features and benefits of the 3RU21 thermal overload relays are listed in the overview table (see "General data" on page /36). /39

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Application Industries The 3RU21 thermal overload relays are suitable for customers from all industries who want to guarantee optimum currentdependent protection of their electrical loads (e. g. motors) under normal starting conditions (CLASS 10). Application The 3RU21 thermal overload relays have been designed for the protection of three-phase and single-phase AC and DC motors. If single-phase AC or DC loads are to be protected by the 3RU21 thermal overload relays, all three bimetal strips must be heated. For this purpose, all main current paths of the relay must be connected in series. Ambient conditions The 3RU21 thermal overload relays have temperature compensation in accordance with IEC 60947-4-1 for the temperature range of -40 to +60 C. For temperatures from +60 to +80 C the upper set value of the setting range must be reduced by the factor listed in the table below. Ambient temperature Derating factor for the upper set value Current ranges C 0.11... 20 A 17... 40 A +60 1.0 1.0 +6 0.94 0.97 +70 0.87 0.94 +7 0.81 0.90 +80 0.73 0.86 Accessories The following optional accessories are available for the 3RU21 thermal overload relays: Terminal bracket for stand-alone installation with screw or spring-type terminals for each size Mechanical RESET for all sizes Cable release for resetting devices which are difficult to access for all sizes Electrical remote RESET module in three voltage variants for all sizes Sealable cover for all sizes Terminal covers for devices with ring lug terminal connection More information Order No. scheme Digit of the Order No. 1st - 3rd 4th th 6th 7th 8th 9th 10th 11th @@@ @ @ @ @ @ @ @ @ Thermal overload relays 3 R U SIRIUS 2nd generation 2 Device series @ Size, rated operational current and power @ @ Setting range of the overload release @ @ Connection method @ Installation type @ Example 3 R U 2 1 1 6 0 A B 0 Note: The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order numbers. For your orders, please use the order numbers quote in the catalog under the Selection and ordering data section. /40

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Type 3RU21 16 3RU21 26 Size S00 S0 Dimensions (W x H x D) (overload relay with stand-alone installation support) Screw terminals Spring-type terminals General technical specifications H W D mm mm 4 x 89 x 79 4 x 102 x 80 4 x 97 x 9 4 x 114 x 97 Trips in the event of Overload and phase failure Trip class acc. to IEC 60947-4-1 CLASS 10 Phase failure sensitivity Yes Overload warning No Reset and recovery Reset options after tripping Manual, automatic and remote RESET 1) Recovery time - For automatic RESET min Depends on the strength of the tripping current and characteristic - For manual RESET min Depends on the strength of the tripping current and characteristic - For remote RESET min Depends on the strength of the tripping current and characteristic Features Display of operating state on device Yes, by means of TEST function/switch position indicator slide TEST function Yes RESET button Yes STOP button Yes Safe operation of motors with "increased safety" type of protection EC type test certificate number acc. to directive 94/9/EC (ATEX) On request Ambient temperature Storage/transport C -... +80 Operation C -40... +70 Temperature compensation C Up to 60 Permissible rated current at - Temperature inside control cabinet 60 C % 100 (over +60 C current reduction is not required) - Temperature inside control cabinet 70 C % 87 Repeat terminals Coil repeat terminals Yes Not required Auxiliary contact repeat terminal Yes Not required Degree of protection acc. to IEC 6029 IP20 Touch protection acc. to IEC 61140 Screw and spring-type terminals: Finger-safe Ring lug terminal connection: Finger-safe only with optional terminal covers Shock resistance with sine acc. to IEC 60068-2-27 g/ms 1/11 2) Electromagnetic compatibility (EMC) Interference immunity Conductor-related interference - Burst acc. to IEC 61000-4-4 (corresponds to degree of severity 3) kv EMC interference immunity is not relevant for thermal overload relays - Surge acc.to IEC 61000-4- (corresponds to degree of severity 3) kv EMC interference immunity is not relevant for thermal overload relays Electrostatic discharge acc. to IEC 61000-4-2 kv EMC interference immunity is not relevant for thermal overload relays (corresponds to degree of severity 3) Field-related interference acc. to IEC 61000-4-3 V/m EMC interference immunity is not relevant for thermal overload relays (corresponds to degree of severity 3) Electromagnetic compatibility (EMC) Emitted interference EMC interference immunity is not relevant for thermal overload relays Resistance to extreme climates Air humidity % 90 Dimensions For "Dimensional drawings" see the note on Technical Information on page /1. Installation altitude above sea level m Up to 2000; above this, please enquire Mounting position The diagrams show the permissible mounting positions for mounting onto contactors and stand-alone installation. For installation in the shaded area, a setting correction of 10 % must be implemented. Stand-alone installation:! # 1 A N Contactor + overload relay:! # " # " # 1 A N 1 A N ' *! $ " # # ' Type of mounting Mounting onto contactor/stand-alone installation with terminal bracket 3) 1) Remote RESET in combination with the appropriate accessories. 2) Auxiliary contacts 9/96 and 97/98: 8 g/11 ms.! # 1 A N! # *! $! 3) For screw and snap-on mounting on TH 3 standard mounting rail. For the technical specifications of the terminal brackets see the note on Technical Information on page /1. /41

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Type 3RU21 16 3RU21 26 Size S00 S0 Width 4 mm 4 mm Main circuit Rated insulation voltage U i V 690 (pollution degree 3) Rated impulse withstand voltage U imp kv 6 Rated operational voltage U e V 690 Type of current Direct current Yes Alternating current Yes, frequency range up to 400 Hz Current setting A A 0.11... 0.16 to 11... 16 1.8... 2. to 34... 40 Power loss per unit (max.) W 3.9... 6.6 3.9... 6 Short-circuit protection With fuse without contactor See "Selection and ordering data" With fuse and contactor See "Technical specifications" --> "Short-circuit protection with fuses/motor starter protectors for motor starters", see note on Technical Information on page /1. Protective separation between main V 440 and auxiliary conducting path acc. to IEC 60947-1 Conductor cross-sections of main circuit Connection type screw terminals Screw terminals Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 Operating devices mm... 6... 6 Prescribed tightening torque Nm 0.8... 1.2 2... 2. Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1), 2 x (0.... 4) 1) Finely stranded with end sleeves (DIN 46228 T1) 2 x (1... 2.) 1), 2 x (2.... 10) 1) mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) 2 x (1... 2.) 1), 2 x (2.... 6) 1) ; max. 1 x 10 AWG cables, solid or stranded AWG 2 x (20... 16) 1), 2 x (18... 14) 1), 2 x 12 Connection type spring-type terminals Spring-type terminals 2 x (16... 12) 1), 2 x (14... 8) 1) Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.) Solid mm 2 1 x (0.... 4) 1 x (1... 10) Finely stranded without end sleeve mm 2 1 x (0.... 2.) 1 x (1... 6) Finely stranded with end sleeves (DIN 46228 T1) mm 2 1 x (0.... 2.) 1 x (1... 6) AWG cables, solid or stranded AWG 1 x (20... 12) 1 x (18... 8) Connection type ring lug terminals Ring lug terminal connection Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 Operating devices mm... 6... 6 Prescribed tightening torque Nm 0.8... 1.2 2... 2. Usable ring lug terminals d 3 mm d 2 = min. 3.2, d 2 = min. 4.3, DIN 46234 without insulation sleeve DIN 4622 without insulation sleeve DIN 46237 with insulation sleeve JIS C280 Type R without insulation sleeve JIS C280 Type RAV with insulation sleeve JIS C280 Type RAP with insulation sleeve d 2 d 3 = max. 7. d 3 = max. 12.2 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply. I2_12740 /42

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Type 3RU21 16 3RU21 26 Size S00 S0 Width 4 mm 4 mm Auxiliary circuit Number of NO contacts 1 Number of NC contacts 1 Auxiliary contacts Assignment 1 NO for the signal "tripped", 1 NC for disconnecting the contactor Rated insulation voltage U i V 690 (pollution degree 3) Rated impulse withstand voltage U imp kv 6 Contact rating of the auxiliary contacts NC contact with alternating current AC-14/AC-1, rated operational current I e at U e : - 24 V A 4-120 V A 4-12 V A 4-230 V A 3-400 V A 2-600 V A 0.7-690 V A 0.7 NO contact with alternating current AC-14/AC-1, rated operational current I e at U e : - 24 V A 3-120 V A 3-12 V A 3-230 V A 2-400 V A 1-600 V A 0.7-690 V A 0.7 NC contact, NO contact with direct current DC-13, rated operational current I e at U e : - 24 V A 1-60 V A On request - 110 V A 0.22-12 V A 0.22-220 V A 0.11 Conventional thermal current I th A 6 Contact reliability Yes (suitability for PLC control; 17 V, ma) Short-circuit protection With fuse - Operational class gg A 6 - Quick A 10 With miniature circuit breaker (C characteristic) A 6 1) Protective separation between main and auxiliary V 440 conducting path acc. to IEC 60947-1 CSA, UL, UR rated data Auxiliary circuit Switching capacity 1) Up to I k 0. ka; 260 V. B600, R300 /43

Overload Relays SIRIUS 3RU2 Thermal Overload Relays General data Type 3RU21 16 3RU21 26 Size S00 S0 Width 4 mm 4 mm Conductor cross-sections for auxiliary circuit Connection type screw terminals Screw terminals Terminal screw M3, Pozidriv size 2 Operating devices mm... 6 Prescribed tightening torque Nm 0.8... 1.2 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) 1), 2 x (0.7... 2.) 1) AWG cables, solid or stranded AWG 2 x (20... 16) 1), 2 x (18... 14) 1) Connection type spring-type terminals Spring-type terminals Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.) Solid mm 2 2 x (0.... 2.) Finely stranded without end sleeve mm 2 2 x (0.... 1.) Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) AWG cables, solid or stranded AWG 2 x (20... 14) Connection type ring terminal end Ring lug terminal connection Terminal screw M3, Pozidriv size 2 Operating devices mm... 6 Prescribed tightening torque Nm 0.8... 1.2 Usable ring lug terminals d 3 mm d 2 = min. 3.2, DIN 46234 without insulation sleeve DIN 4622 without insulation sleeve DIN 46237 with insulation sleeve JIS C280 Type R without insulation sleeve JIS C280 Type RAV with insulation sleeve JIS C280 Type RAP with insulation sleeve d 2 d 3 = max. 7. 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply. I2_12740 /44

Selection and ordering data 3RU21 thermal overload relays for mounting onto contactor 1), CLASS 10 Features and technical specifications: Screw, spring-type or ring lug terminal connection 2) Overload and phase failure protection Auxiliary contacts 1 NO + 1 NC Manual and automatic RESET Switch position indicators Overload Relays SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications TEST function STOP button Sealable covers (optional accessory) Terminal covers for devices with ring lug terminal connection (optional accessory) 3RU21 16-4AB0 3RU21 16-4AC0 3RU21 26-4FB0 3RU21 26-4AC0 Size contactor 3) Current setting value of the current-dependent Screw terminals Spring-type terminals overload release Order No. Order No. A kg kg Size S00 S00 0.11... 0.16 3RU21 16-0AB0 0.130 3RU21 16-0AC0 0.10 0.14... 0.2 3RU21 16-0BB0 0.130 3RU21 16-0BC0 0.10 0.18... 0.2 3RU21 16-0CB0 0.130 3RU21 16-0CC0 0.10 0.22... 0.32 3RU21 16-0DB0 0.130 3RU21 16-0DC0 0.10 0.28... 0.4 3RU21 16-0EB0 0.130 3RU21 16-0EC0 0.10 0.3... 0. 3RU21 16-0FB0 0.130 3RU21 16-0FC0 0.10 0.4... 0.63 3RU21 16-0GB0 0.130 3RU21 16-0GC0 0.10 0.... 0.8 3RU21 16-0HB0 0.130 3RU21 16-0HC0 0.10 0.7... 1 3RU21 16-0JB0 0.130 3RU21 16-0JC0 0.10 0.9... 1.2 3RU21 16-0KB0 0.130 3RU21 16-0KC0 0.10 1.1... 1.6 3RU21 16-1AB0 0.130 3RU21 16-1AC0 0.10 1.4... 2 3RU21 16-1BB0 0.130 3RU21 16-1BC0 0.10 1.8... 2. 3RU21 16-1CB0 0.130 3RU21 16-1CC0 0.10 2.2... 3.2 3RU21 16-1DB0 0.130 3RU21 16-1DC0 0.10 2.8... 4 3RU21 16-1EB0 0.130 3RU21 16-1EC0 0.10 3.... 3RU21 16-1FB0 0.130 3RU21 16-1FC0 0.10 4.... 6.3 3RU21 16-1GB0 0.130 3RU21 16-1GC0 0.10.... 8 3RU21 16-1HB0 0.130 3RU21 16-1HC0 0.10 7... 10 3RU21 16-1JB0 0.130 3RU21 16-1JC0 0.10 9... 12. 3RU21 16-1KB0 0.130 3RU21 16-1KC0 0.10 11... 16 3RU21 16-4AB0 0.130 3RU21 16-4AC0 0.10 Size S0 S0 1.8... 2. 3RU21 26-1CB0 0.160 3RU21 26-1CC0 0.220 2.2... 3.2 3RU21 26-1DB0 0.160 3RU21 26-1DC0 0.220 2.8... 4 3RU21 26-1EB0 0.160 3RU21 26-1EC0 0.220 3.... 3RU21 26-1FB0 0.160 3RU21 26-1FC0 0.220 4.... 6.3 3RU21 26-1GB0 0.160 3RU21 26-1GC0 0.220.... 8 3RU21 26-1HB0 0.160 3RU21 26-1HC0 0.220 7... 10 3RU21 26-1JB0 0.160 3RU21 26-1JC0 0.220 9... 12. 3RU21 26-1KB0 0.160 3RU21 26-1KC0 0.220 11... 16 3RU21 26-4AB0 0.160 3RU21 26-4AC0 0.220 14... 20 3RU21 26-4BB0 0.160 3RU21 26-4BC0 0.220 17... 22 3RU21 26-4CB0 0.160 3RU21 26-4CC0 0.220 20... 2 3RU21 26-4DB0 0.160 3RU21 26-4DC0 0.220 23... 28 3RU21 26-4NB0 0.160 3RU21 26-4NC0 0.220 27... 32 3RU21 26-4EB0 0.160 3RU21 26-4EC0 0.220 30... 36 3RU21 26-4PB0 0.160 3RU21 26-4PC0 0.220 34... 40 3RU21 26-4FB0 0.160 3RU21 26-4FC0 0.220 1) For matching terminal brackets see "Accessories" on page /47. 2) The 3RU21 overload relays are also available with ring lug terminal connection. The Order No. must be changed in the 10th position to "J": e. g. 3RU21 16-0AJ0. 3) Observe maximum rated operational current of the devices. Illustrations are approximate /4

Overload Relays SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications 3RU21 thermal overload relays for stand-alone installation 1), CLASS 10 Features and technical specifications: Screw or spring-type terminals Overload and phase failure protection Auxiliary contacts 1 NO + 1 NC Manual and automatic RESET Switch position indicators TEST function STOP button Sealable covers (optional accessory) 3RU21 16-4AB1 3RU21 16-4AC1 3RU21 26-4FB1 3RU21 26-4FC1 Size contactor 2) Current setting value of the current-dependent Screw terminals Spring-type terminals overload release Order No. Order No. A kg kg Size S00 S00 0.11... 0.16 3RU21 16-0AB1 0.170 3RU21 16-0AC1 0.190 0.14... 0.2 3RU21 16-0BB1 0.170 3RU21 16-0BC1 0.190 0.18... 0.2 3RU21 16-0CB1 0.170 3RU21 16-0CC1 0.190 0.22... 0.32 3RU21 16-0DB1 0.170 3RU21 16-0DC1 0.190 0.28... 0.4 3RU21 16-0EB1 0.170 3RU21 16-0EC1 0.190 0.3... 0. 3RU21 16-0FB1 0.170 3RU21 16-0FC1 0.190 0.4... 0.63 3RU21 16-0GB1 0.170 3RU21 16-0GC1 0.190 0.... 0.8 3RU21 16-0HB1 0.170 3RU21 16-0HC1 0.190 0.7... 1 3RU21 16-0JB1 0.170 3RU21 16-0JC1 0.190 0.9... 1.2 3RU21 16-0KB1 0.170 3RU21 16-0KC1 0.190 1.1... 1.6 3RU21 16-1AB1 0.170 3RU21 16-1AC1 0.190 1.4... 2 3RU21 16-1BB1 0.170 3RU21 16-1BC1 0.190 1.8... 2. 3RU21 16-1CB1 0.170 3RU21 16-1CC1 0.190 2.2... 3.2 3RU21 16-1DB1 0.170 3RU21 16-1DC1 0.190 2.8... 4 3RU21 16-1EB1 0.170 3RU21 16-1EC1 0.190 3.... 3RU21 16-1FB1 0.170 3RU21 16-1FC1 0.190 4.... 6.3 3RU21 16-1GB1 0.170 3RU21 16-1GC1 0.190.... 8 3RU21 16-1HB1 0.170 3RU21 16-1HC1 0.190 7... 10 3RU21 16-1JB1 0.170 3RU21 16-1JC1 0.190 9... 12. 3RU21 16-1KB1 0.170 3RU21 16-1KC1 0.190 11... 16 3RU21 16-4AB1 0.170 3RU21 16-4AC1 0.280 Size S0 S0 14... 20 3RU21 26-4BB1 0.200 3RU21 26-4BC1 0.280 17... 22 3RU21 26-4CB1 0.200 3RU21 26-4CC1 0.280 20... 2 3RU21 26-4DB1 0.200 3RU21 26-4DC1 0.280 23... 28 3RU21 26-4NB1 0.200 3RU21 26-4NC1 0.280 27... 32 3RU21 26-4EB1 0.200 3RU21 26-4EC1 0.280 30... 36 3RU21 26-4PB1 0.200 3RU21 26-4PC1 0.280 34... 40 3RU21 26-4FB1 0.200 3RU21 26-4FC1 0.280 1) Screw and snap-on mounting onto TH 3 standard mounting rail 2) Observe maximum rated operational current of the devices. /46 Illustrations are approximate

Overload Relays SIRIUS 3RU2 Thermal Overload Relays Accessories Overview Overload relays for standard applications The following optional accessories are available for the 3RU21 thermal overload relays: Terminal bracket for stand-alone installation with screw or spring-type terminals for each size Mechanical RESET for all sizes Cable release for resetting devices which are difficult to access for all sizes Electrical remote RESET module in three voltage variants for all sizes Sealable cover for all sizes Terminal covers for devices with ring lug terminal connection Selection and ordering data Version Size Order No. kg Terminal brackets for stand-alone installation 1) Terminal brackets for overload relays with screw terminals For separate mounting of the overload relays; screw and snap-on mounting onto TH 3 standard mounting rail Screw terminals S00 3RU29 16-3AA01 0.040 S0 3RU29 26-3AA01 0.00 3RU29 16-3AA01 3RU29 26-3AA01 Terminal brackets for overload relays with spring-type terminals For separate mounting of the overload relays; screw and snap-on mounting onto TH 3 standard mounting rail Spring-type terminals S00 3RU29 16-3AC01 0.040 S0 3RU29 26-3AC01 0.060 3RU29 16-3AC01 3RU29 26-3AC01 Mechanical RESET Resetting plungers, holders and formers S00, S0 3RU29 00-1A 0.038 Pushbuttons with extended stroke S00, S0 3SB30 00-0EA11 0.020 (12 mm), IP6, 22 mm Extension plungers S00, S0 3SX1 33 0.004 For compensation of the distance between the pushbutton and the unlatching button of the relay 3RU29 00-1A with pushbutton and extension plunger Cable releases with holder for RESET For 6. mm hole in the control panel; max. control panel thickness 8 mm Length 400 mm S00, S0 3RU29 00-1B 0.063 Length 600 mm S00, S0 3RU29 00-1C 0.073 3RU29 00-1. 1) The accessories are identical to those of the 3RB30/3RB31 solid-state overload relays. Illustrations are approximate /47

Overload Relays SIRIUS 3RU2 Thermal Overload Relays Accessories Version Size Order No. PU (UNIT, SET, M) Modules for remote RESET, electrical 3RU19 00-2A.71 Sealable covers PS* Operating range 0.8... 1.1 x U s, power consumption AC 80 VA, DC 70 W, ON period 0.2... 4 s, switching frequency 60/h 24... 30 V AC/DC S00, S0 3RU19 00-2AB71 0.066 110... 127 V AC/DC S00, S0 3RU19 00-2AF71 0.067 220... 20 V AC/DC S00, S0 3RU19 00-2AM71 0.066 For covering the setting knobs S00, S0 3RV29 08-0P 1 10 units 0.100 3RV29 08-0P Terminal covers 3RU29 16-3BJ21 3RU29 26-3BJ21 Covers for devices with ring lug terminal connection (ensure finger-safety) Main current level Ring lug terminal connection - Cover between contactor S00 3RU29 16-3BJ21 1 10 units 0.001 and overload relay S0 3RU29 26-3BJ21 1 10 units 0.001 for direct mounting of the overload relay - Cover for overload relay on load side S00 3RU29 16-3BJ20 1 10 units 0.001 S0 3RV29 28-4AA00 1 1 unit 0.010 Auxiliary current level S00, S0 3RT29 16-4EA13 1 10 units 0.001 3RU29 16-3BJ20 3RV29 28-4AA00 3RT29 16-4EA13 General accessories Tools for opening spring-type terminals 3RA29 08-1A Blank labels NSB0_01429b 3RT19 00-1SB20 1) PC labeling system for individual inscription of unit labeling plates available from: murrplastik Systems, Inc. www.murrplastik.com. Version Use Order No. PU (UNIT, SET, M) Screwdrivers for all SIRIUS devices with spring-type terminals Length 200 mm, 3.0 mm x 0. mm, titanium gray/black, partially insulated Unit labeling plates 1) for SIRIUS devices 20 mm x 7 mm, pastel turquoise Main and auxiliary circuit connection: 3RU2, 3RB3 PS* Spring-type terminals 3RA29 08-1A 1 1 unit 0.04 3RU2, 3RB3 3RT19 00-1SB20 100 340 units 0.200 kg * You can order this quantity or a multiple thereof. /48 Illustrations are approximate

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays General data Overview 1 2 2 1 Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters. The overload relay can be connected directly using these connection pins. Stand-alone installation is possible as an alternative (in conjunction with a terminal bracket for stand-alone installation). 2 Selector switch for manual/automatic RESET and RESET button: With the slide switch you can choose between manual and automatic RESET. A device set to manual RESET can be reset locally by pressing the RESET button. On the 3RB31 an electrical remote RESET is integrated. 3 Switch position indicator and TEST function of the wiring: Indicates a trip and enables the wiring test. 4 Solid-state test (device test): Enables a test of all important device components and functions. Motor current setting: Setting the device to the rated motor current is easy with the large rotary knob. 6 7 Trip class setting/internal ground-fault detection (only 3RB31): Using the rotary switch you can set the required trip class and activate the internal ground-fault detection dependent on the start-up conditions. Connecting terminals (removable joint block for auxiliary circuits): Depending on the device version, the terminals for screw and spring-type connection are configured for the main and auxiliary circuit. A sealable transparent cover can be optionally mounted (accessory). It secures the motor current setting against adjustment. NSB0_02077 3 6 4 7 The 3RB30 and 3RB31 solid-state overload relays up to 40 A with internal power supply have been designed for inverse-time delayed protection of loads with normal and heavy starting (for "Function" see note on Technical Information on page /1) against excessive temperature rises due to overload, phase unbalance or phase failure. An overload, phase unbalance or phase failure result in an increase of the motor current beyond the set rated motor current. This current rise is detected by the current transformers integrated into the devices and evaluated by corresponding solid-state circuits which then output a pulse to the auxiliary contacts. The auxiliary contacts then switch off the load by means of a contactor. The break time depends on the ratio between the tripping current and set current I e and is stored in the form of a long-term stable tripping characteristic (for "Characteristic Curves" see the note on Technical Information on page /1). In addition to inverse-time delayed protection of loads against excessive temperature rises due to overload, phase unbalance and phase failure, the 3RB31 solid-state overload relays also allow internal ground-fault detection (not possible in conjunction with contactor assemblies for wye-delta starting). This provides protection of loads against high-resistance short-circuits due to damage to the insulation material, moisture, condensed water etc. The "tripped" status is signaled by means of a switch position indicator. Resetting takes place either manually or automatically after a recovery time has elapsed (for "Function" see note on Technical Information on page /1). The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable materials. They comply with all important worldwide standards and approvals. "Increased safety" type of protection EEx e according to ATEX directive 94/9/EC The 3RB30/3RB31 solid-state overload relays are suitable for the overload protection of explosion-proof motors with "increased safety" type of protection EEx e. The relays meet the requirements of EN 60079-7 (Electrical apparatus for areas subject to explosion hazards Increased safety "e"); see Chapter 9 "Appendix" --> "Standards and approvals" --> "Type overview of approved devices for explosion-protected areas (ATEX Explosion Protection)". 3RB31 23-4VE00 solid-state overload relays Benefits The most important features and benefits of the 3RB30/3RB31 solid-state overload relays are listed in the overview table (see "General data" on page /36). /49

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays General data Application Industries The 3RB30/3RB31 solid-state overload relays are suitable for customers from all industries who want to guarantee optimum inverse-time delayed protection of their electrical loads (e.g. motors) under normal and heavy starting conditions (CLASS to CLASS 30), minimize project completion times, inventories and power consumption, and optimize plant availability and maintenance management. Application The 3RB30/3RB31 solid-state overload relays have been designed for the protection of induction motors in sinusoidal 0/60 Hz voltage networks. The relays are not suitable for the protection of single-phase AC or DC loads. Accessories The following optional accessories are available for the 3RB30/3RB31 solid-state overload relays: Terminal bracket for stand-alone installation with screw or spring-type terminals for all sizes The 3RU21 thermal overload relay or the 3RB22/3RB23 solidstate overload relay can be used for single-phase AC loads. For DC loads we recommend the 3RU21 thermal overload relay. Ambient conditions The devices are insensitive to external influences such as shocks, corrosive environments, ageing and temperature fluctuation. For the temperature range from 2 to +60 C, the 3RB30/3RB31 solid-state overload relays compensate the temperature according to IEC 60947-4-1. Mechanical RESET for all sizes Cable release for resetting devices which are difficult to access for all sizes Sealable cover for all sizes More information Order No. scheme Digit of the Order No. 1. - 3. 4.. 6. 7. 8. 9. 10. 11. @@@ @ @ @ @ @ @ @ @ Solid-state overload relays 3 R B SIRIUS 3rd generation 3 Device series @ Size, rated operational current and power @ Version of the automatic RESET, electrical remote RESET @ Trip class (CLASS) @ Setting range of the overload release @ Connection method @ Installation type @ Example 3 R B 3 0 1 6 1 R B 0 Note: The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order numbers. For your orders, please use the order numbers quote in the catalog under the Selection and ordering data section. /0

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays General data Type 3RB30 1., 3RB31 1. Size S00 S0 Dimensions (W x H x D) (overload relay with stand-alone installation support) Screw terminals Spring-type terminals General technical specifications Trips in the event of 1) Permissible rated current for heavy starting Size S0 at 10 to 40 A: - CLASS 20, I e max = 32 A, - CLASS 30, I e max = 2 A. 2) Signaling contact 97/98 in position "tripped": 4/11 g/ms. mm mm 4 x 89 x 80 4 x 102 x 80 Overload, phase failure, and phase unbalance + ground fault (for 3RB31 only) 3RB30 2., 3RB31 2. 4 x 97 x 94 4 x 116 x 9 Trip class acc. to IEC 60947-4-1 CLASS 3RB30: 10, 20; 3RB31:, 10, 20 and 30 adjustable Phase failure sensitivity Yes Overload warning No Reset and recovery Reset options after tripping Manual, automatic and remote RESET (depending on the version) Recovery time - For automatic RESET min Approx. 3 - For manual RESET min Immediately - For remote RESET min Immediately Features Display of operating state on device Yes, by means of switch position indicator slide TEST function Yes, test of electronics by pressing the TEST button / Test of auxiliary contacts and wiring of control circuit by actuating the switch position indicator slide / Self-monitoring RESET button Yes STOP button No Explosion protection Safe operation of motors with "increased safety" type of protection EC type test certificate number acc. to directive 94/9/EC (ATEX) PTB 09 ATEX 3001 II (2) GD Ambient temperatures Storage/transport C -40... +80 Operation C -2... +60 Temperature compensation C +60 Permissible rated current at - Temperature inside control cabinet 60 C % 100 100 1) - Temperature inside control cabinet 70 C % On request Repeat terminals Coil repeat terminals Yes Not required Auxiliary contact repeat terminal Yes Not required Degree of protection acc. to IEC 6029 IP20 Touch protection acc. to IEC 61140 Finger-safe Shock resistance with sine acc. to IEC 60068-2-27 g/ms 1/11 2) Electromagnetic compatibility (EMC) Interference immunity Conductor-related interference H W D - Burst acc. to IEC 61000-4-4 kv 2 (power ports), 1 (signal ports) (corresponds to degree of severity 3) - Surge acc. to IEC 61000-4- kv 2 (line to earth), 1 (line to line) (corresponds to degree of severity 3) Electrostatic discharge acc. to IEC 61000-4-2 kv 8 (air discharge), 6 (contact discharge) (corresponds to degree of severity 3) Field-related interference acc. to IEC 61000-4-3 V/m 10 (corresponds to degree of severity 3) Electromagnetic compatibility (EMC) Emitted interference Degree of severity B according to EN 011 (CISPR 11) and EN 022 (CISPR 22) Resistance to extreme climates Air humidity % 9 Dimensions For "Dimensional drawings" see the note on Technical Information on page /1. Installation altitude above sea level m Up to 2000 Mounting position Any Type of mounting Direct mounting/stand-alone installation with terminal bracket /1

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays General data Type 3RB30 1., 3RB31 1. 3RB30 2., 3RB31 2. Size S00 S0 Width 4 mm 4 mm Main circuit Rated insulation voltage U i V 690 (pollution degree 3) Rated impulse withstand voltage U imp kv 6 Rated operational voltage U e V 690 Type of current Direct current No Alternating current Yes, 0/60 Hz % Current setting A A 0.1... 0.4 to 4... 16 Power loss per unit (max.) W 0.0... 0.2 Short-circuit protection With fuse without contactor See "Selection and ordering data" With fuse and contactor Protective separation between main and auxiliary conducting path acc. to IEC 60947-1 (pollution degree 2) Conductor cross-sections of main circuit Connection type screw terminals V 690 1) 0.1... 0.4 to 10... 40 See "Technical specifications" --> "Short-circuit protection with fuses/motor starter protectors for motor starters", see note on Technical Information on page /1. Screw terminals Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 Operating devices mm... 6... 6 Prescribed tightening torque Nm 0.8... 1.2 2... 2. Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 x (0.... 1.) 2), 2 x (0.7... 2.) 2), 2 x (0.... 4) 2) 2 x (1... 2.) 2), 2 x (2.... 10) 2) Finely stranded with end sleeves (DIN 46228 T1) mm 2 2 x (0.... 1.) 2), 2 x (0.7... 2.) 2) 2 x (1... 2.) 2), 2 x (2.... 6) 2) ; max. 1 x 10 AWG cables, solid or stranded AWG 2 x (20... 16) 2), 2 x (18... 14) 2), 2 x 12 Connection type spring-type terminals Spring-type terminals 2 x (16... 12) 2), 2 x (14... 8) 2) Operating devices mm 3.0 x 0. and 3. x 0. Conductor cross-sections (min./max.) Solid mm 2 1 x (0.... 4) 1 x (1... 10) Finely stranded without end sleeve mm 2 1 x (0.... 2.) 1 x (1... 6) Finely stranded with end sleeves (DIN 46228 T1) mm 2 1 x (0.... 2.) 1 x (1... 6) AWG cables, solid or stranded AWG 1 x (20... 12) 1 x (18... 8) 1) For grounded networks, otherwise 600 V. 2) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply. /2

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays General data Type 3RB30 1., 3RB31 1. 3RB30 2., 3RB31 2. Size S00 S0 Width 4 mm 4 mm Auxiliary circuit Number of NO contacts 1 Number of NC contacts 1 Auxiliary contacts Assignment 1 NO for the signal "tripped", 1 NC for disconnecting the contactor Rated insulation voltage U i V 300 (pollution degree 3) Rated impulse withstand voltage U imp kv 4 Auxiliary contacts Contact rating NC contact with alternating current AC-14/AC-1 Rated operational current I e at U e : - 24 V A 4-120 V A 4-12 V A 4-20 V A 3 NO contact with alternating current AC-14/AC-1: Rated operational current I e at U e : - 24 V A 4-120 V A 4-12 V A 4-20 V A 3 NC, NO contact with direct current DC-13: Rated operational current I e at U e : - 24 V A 2-60 V A 0. - 110 V A 0.3-12 V A 0.3-20 V A 0.11 Conventional thermal current I th A Contact reliability Yes (suitability for PLC control; 17 V, ma) Short-circuit protection With fuse, gg operational class A 6 Ground-fault protection (only 3RB31) The information refers to sinusoidal residual currents at 0/60 Hz Tripping value I > 0.7 I motor Operating range I Lower current setting value < I motor < 3. upper current setting value Response time t trip (in steady-state condition) s < 1 Integrated electrical remote RESET (only 3RB31) Connecting terminals A3, A4 24 V DC, max. 200 ma for 20 ms, then < 10 ma Protective separation between main and auxiliary V 300 conducting path acc. to IEC 60947-1 CSA, UL, UR rated data Auxiliary circuit Switching capacity 3RB30: B600, R300; 3RB31: B300, R300 Conductor cross-sections for auxiliary circuit Connection type screw terminals Screw terminals Terminal screw M3, Pozidriv size 2 Operating devices mm... 6 Prescribed tightening torque Nm 0.8... 1.2 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 1 (0.... 4), 2 (0.... 2.) Finely stranded with end sleeve mm 2 1 (0.... 2.), 2 (0.... 1.) AWG cables, solid or stranded AWG 2 (20... 14) Connection type spring-type terminals Spring-type terminals Operating devices mm 3.0 x 0. Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Solid mm 2 2 (0.2... 1.) Finely stranded without end sleeve mm 2 2 (0.2... 1.) Finely stranded with end sleeve mm 2 2 (0.2... 1.) AWG cables, solid or stranded AWG 2 (24... 16) /3

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays 3RB30, 3RB31 up to 40 A for standard applications Selection and ordering data 3RB30 solid-state overload relays for mounting onto contactor 1), CLASS 10 Features and technical specifications: Screw and spring-type terminals Overload protection, phase failure protection and unbalance protection Internal power supply Auxiliary contacts 1 NO + 1 NC Manual and automatic RESET Switch position indicators TEST function and self-monitoring Sealable covers (optional accessory) 3RB30 16-1TB0 3RB30 16-1TE0 3RB30 26-1VB0 3RB30 26-1VE0 Size of contactor 2) Set current value of the inverse-time delayed overload release Screw terminals Order No. Spring-type terminals Order No. A kg kg Size S00 1) S00 0.1 0.4 3RB30 16-1RB0 0.172 3RB30 16-1RE0 0.172 0.32 1.2 3RB30 16-1NB0 0.172 3RB30 16-1NE0 0.172 1 4 3RB30 16-1PB0 0.172 3RB30 16-1PE0 0.172 3 12 3RB30 16-1SB0 0.172 3RB30 16-1SE0 0.172 4... 16 3RB30 16-1TB0 0.172 3RB30 16-1TE0 0.172 Size S0 1) S0 0.1 0.4 3RB30 26-1RB0 0.20 3RB30 26-1RE0 0.240 0.32 1.2 3RB30 26-1NB0 0.20 3RB30 26-1NE0 0.240 1 4 3RB30 26-1PB0 0.20 3RB30 26-1PE0 0.240 3 12 3RB30 26-1SB0 0.20 3RB30 26-1SE0 0.240 6 2 3RB30 26-1QB0 0.20 3RB30 26-1QE0 0.240 10... 40 3RB30 26-1VB0 0.20 3RB30 26-1VE0 0.240 1) With the suitable terminal brackets (see "Accessories", page /7), these overload relays can also be installed as stand-alone units. 2) Observe maximum rated operational current of the devices. /4 Illustrations are approximate

3RB30 solid-state overload relays for mounting onto contactor 1), CLASS 20 Features and technical specifications: Screw and spring-type terminals Overload protection, phase failure protection and unbalance protection Internal power supply Overload Relays SIRIUS 3RB3 Solid-State Overload Relays 3RB30, 3RB31 up to 40 A for standard applications Auxiliary contacts 1 NO + 1 NC Manual and automatic RESET Switch position indicators TEST function and self-monitoring Sealable covers (optional accessory) 3RB30 16-2TB0 3RB30 16-2TE0 3RB30 26-2VB0 3RB30 26-2VE0 Size of contactor 2) Set current value of the inverse-time delayed overload release Screw terminals Order No. Spring-type terminals Order No. A kg kg Size S00 1) S00 0.1 0.4 3RB30 16-2RB0 0.172 3RB30 16-2RE0 0.172 0.32 1.2 3RB30 16-2NB0 0.172 3RB30 16-2NE0 0.172 1 4 3RB30 16-2PB0 0.172 3RB30 16-2PE0 0.172 3 12 3RB30 16-2SB0 0.172 3RB30 16-2SE0 0.172 4... 16 3RB30 16-2TB0 0.172 3RB30 16-2TE0 0.172 Size S0 1) S0 0.1 0.4 3RB30 26-2RB0 0.200 3RB30 26-2RE0 0.20 0.32 1.2 3RB30 26-2NB0 0.200 3RB30 26-2NE0 0.20 1 4 3RB30 26-2PB0 0.200 3RB30 26-2PE0 0.20 3 12 3RB30 26-2SB0 0.200 3RB30 26-2SE0 0.20 6 2 3RB30 26-2QB0 0.200 3RB30 26-2QE0 0.20 10... 40 3RB30 26-2VB0 0.200 3RB30 26-2VE0 0.20 1) With the suitable terminal brackets (see "Accessories", page /7), these overload relays can also be installed as stand-alone units. 2) Observe maximum rated operational current of the devices. Illustrations are approximate /

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays 3RB30, 3RB31 up to 40 A for standard applications 3RB31 solid-state overload relays for mounting onto contactor 1), CLASS, 10, 20 and 30 adjustable Features and technical specifications: Screw and spring-type terminals Overload protection, phase failure protection and unbalance protection Internal ground-fault detection (requires activation) Internal power supply Auxiliary contacts 1 NO + 1 NC Manual and automatic RESET Electrical remote RESET integrated Switch position indicators TEST function and self-monitoring Sealable covers (optional accessory) 3RB31 13-4TB0 3RB31 13-4TE0 3RB31 23-4VB0 3RB31 23-4VE0 Size of contactor 2) Set current value of the inverse-time delayed overload release Screw terminals Order No. Spring-type terminals Order No. A kg kg Size S00 1) S00 0.1 0.4 3RB31 13-4RB0 0.17 3RB31 13-4RE0 0.17 0.32 1.2 3RB31 13-4NB0 0.17 3RB31 13-4NE0 0.17 1 4 3RB31 13-4PB0 0.17 3RB31 13-4PE0 0.17 3 12 3RB31 13-4SB0 0.17 3RB31 13-4SE0 0.17 4... 16 3RB31 13-4TB0 0.17 3RB31 13-4TE0 0.17 Size S0 1) S0 0.1 0.4 3RB31 23-4RB0 0.200 3RB31 23-4RE0 0.20 0.32 1.2 3RB31 23-4NB0 0.17 3RB31 23-4NE0 0.17 1 4 3RB31 23-4PB0 0.200 3RB31 23-4PE0 0.20 3 12 3RB31 23-4SB0 0.200 3RB31 23-4SE0 0.20 6 2 3RB31 23-4QB0 0.200 3RB31 23-4QE0 0.20 10... 40 3RB31 23-4VB0 0.200 3RB31 23-4VE0 0.20 1) With the suitable terminal brackets (see "Accessories", page /7), these overload relays can also be installed as stand-alone units. 2) Observe maximum rated operational current of the devices. /6 Illustrations are approximate

Overload Relays SIRIUS 3RB3 Solid-State Overload Relays Accessories Overview Overload relays for standard applications The following optional accessories are available for the 3RB30/3RB31 solid-state overload relays: Terminal bracket for stand-alone installation with screw or spring-type terminals for all sizes Mechanical RESET for all sizes Cable release for resetting devices which are difficult to access for all sizes Sealable cover for all sizes Selection and ordering data Version Size Order No. kg Terminal brackets for stand-alone installation 1) Terminal brackets for overload relays with screw terminals For separate mounting of the overload relays; screw and snap-on mounting onto TH 3 standard mounting rail Screw terminals S00 3RU29 16-3AA01 0.040 S0 3RU29 26-3AA01 0.00 3RU29 16-3AA01 3RU29 26-3AA01 Terminal brackets for overload relays with spring-type terminals For separate mounting of the overload relays; screw and snap-on mounting onto TH 3 standard mounting rail Spring-type terminals S00 3RU29 16-3AC01 0.040 S0 3RU29 26-3AC01 0.060 3RU29 16-3AC01 3RU29 26-3AC01 Mechanical RESET Resetting plungers, holders and formers Pushbuttons with extended stroke (12 mm), IP6, 22 mm Extension plungers For compensation of the distance between a pushbutton and the unlatching button of the relay 3RB39 80-0A with pushbutton and extension plunger Cable releases with holder for RESET S00, S0 3RB39 80-0A 0.038 S00, S0 3SB30 00-0EA11 0.020 S00, S0 3SX1 33 0.004 For 6. mm holes in the control panel; max. control panel thickness 8 mm Length 400 mm S00, S0 3RB39 80-0B 0.063 Length 600 mm S00, S0 3RB39 80-0C 0.073 3RB39 80-0. Sealable covers For covering the setting knobs S00, S0 3RB39 84-0 0.001 3RB39 84-0 1) The accessories are identical to those of the 3RU21 thermal overload relays. Illustrations are approximate /7