Version 03.1 Page 1 of 22

Similar documents
2 nd. Monitoring period: 01/01/ /12/2011. Version 2.0. June 20, Climate Bridge Ltd.

15 MW Solar Photovoltaic Power Project at Gujarat

Joint Crediting Mechanism Approved Methodology ID_AM014 Installation of Tribrid Systems to mobile communication s Base Transceiver Stations

Joint Crediting Mechanism Approved Methodology VN_AM009 Installation of Container Formation Facility at Lead Acid Battery Factory

JCM Project Design Document Form

Joint Crediting Mechanism Approved Methodology KE_AM001 Electrification of communities using Micro hydropower generation

Bundled wind power project in Harshnath managed by Enercon (India) Limited

The low carbonization of Mobile communication s BTS (Base Transceiver Station) by the Introduction of TRIBRID system in Indonesia.

JEA Distributed Generation Policy Effective April 1, 2018

Contact person: Pablo Taboada Mobile:

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION

Policy & Regulatory Issues : Solar & Wind. Shri Rajinder Kumar Kaura CMD, Bergen Group India 21 st August 2014

Capture The Power of Photovoltaics. IEEE Power Engineering Society Meeting May 2005

BARES II Wind Power Plant. MONITORING REPORT 01 February May 2011 (Both days included) Project Standard: VER+

24. SOLAR INCENTIVE PROGRAM II

GS-VER MONITORING REPORT Burgaz Wind Farm Project Turkey page 1 / 17

CITY OF SASKATOON ADMINISTRATIVE POLICY

Portland General Electric Company Fourteenth Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Thirteenth Revision of Sheet No.

(2) Scope. 220 CMR applies to all Distribution Companies subject to the jurisdiction of the Department.

Draft Small-scale Methodology AMS-III.S: Introduction of low-emission vehicles/technologies to commercial vehicle fleets

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

GS-VER MONITORING REPORT Keltepe Wind Farm Project Turkey page 1 / 19

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES

NEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES AN ORDER OF THE BOARD NO. P.U. 17(2017)

RATE ORDER 2015 UNIFORM ELECTRICITY TRANSMISSION RATES January 08, 2015

JCM Project Design Document Form

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No.

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

Eco-Driving by Utilizing a Digital Tachograph System

MONITORING REPORT 82 MW LAU RENUN HYDRO POWER PLANT NORTH SUMATRA

Solar Energy Opportunities for New Schools July 10, School Board Work Session

The Gold Standard Suppressed Demand Methodology Micro- scale Electrification and Energization. May Page 1 of 13

Global and China Thin-film Solar Cell Industry Report, Apr. 2011

GS-VER MONITORING REPORT Sayalar Wind Farm Project Turkey page 1 / 16

Methodological tool Baseline emissions for modal shift measures in urban passenger transport

Bugoye 13.0 MW Run-of-River Hydropower Project

LAYOUT REPORT OF GROUND MOUNTED PROJECT

Considerations for Municipal Solar Projects. Ben Frevert Larsen Engineers November 16, 2016

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

AS/NZS :2016. Grid connection of energy systems via inverters AS/NZS :2016. Part 1: Installation requirements

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California.

ENERGY STRATEGY FOR YUKON. Net Metering Policy DRAFT FOR CONSULTATION

Introducing the world's most reliable solar panel. Company presentation / Solar panels

Merger of the generator interconnection processes of Valley Electric and the ISO;

Submission to the IESO re: RDGI Fund Virtual Net Metering Investigation Topic

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

The estimated CO2 emission reduction is 2,259 tco2 for the first year and 8,407 tco2 for the second year or later.

March 14, Please contact the undersigned directly with any questions or concerns regarding the foregoing.

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

Operational Opportunities to Minimize Renewables Curtailments

LIBERTY UTILITIES (CALPECO ELECTRIC) LLC SOUTH LAKE TAHOE, CALIFORNIA 3rd Revised CPUC Sheet No. 137 Canceling 2nd Revised CPUC Sheet No.

LANCASTER CHOICE ENERGY S BIENNIAL ENERGY STORAGE PROCUREMENT COMPLIANCE REPORT

8 Troubleshooting and Maintenance

Part 3 Agreement Programs for 2017 and Greenhouse Gas Reduction (Renewable and Low Carbon Fuel Requirements) Act

Example 1MW Solar System for Fosters Yatala

Net Metering & Compensation Seminar

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice

Engr. Silver Navarro, Jr. HOMER Pro Deep Dive Workshop Asian Clean Energy Forum 2016 ADB, Manila. Philippines

SMALL BATTERY CHARGING SYSTEMS

Wagon repair workshop Jhansi Under North Central Railway. Workshop budget Rs Crores. Established in year 1889

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E. San Francisco, California

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Contents. Solar Select TM Frequently Asked Questions

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Fuel Mix Disclosure 2016

Topic Small Projects (< 100 kw) Large Projects (>100 kw)

TILLAMOOK PEOPLE S UTILITY DISTRICT

ROLE OF HAREDA IN NET METERING. By : P.C. Sharma Project Officer

PART 2 GUIDELINES. To be eligible to receive a financial incentive, the following conditions must be met:

ELG4126: Case Study 2 Hybrid System Design and Installation

GREENER SHIPPING SUMMIT 2017

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

Everybody talks about the weather, but nobody ever does anything about it. Mark Twain

CITY OF SANTA CLARA. RATE OPTIONS: Non Time of Use Time of Use CUSTOMER CHARGE For Each Service Address per meter per month $ $306.

Large General Service Time-of-Use Storage Program

Creating A Greener Energy Future For the Commonwealth. Massachusetts RPS Solar Carve-Out: Overview & Program Basics.

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

Revised Cal. P.U.C. Sheet No E** Pacific Gas and Electric Company Cancelling Revised Cal. P.U.C. Sheet No E San Francisco, California

OVERVIEW OF UNIFORM TRANSMISSION RATES

SCC Greenhouse Gas Assessment

Core Components for Large-scale PV Generation Systems

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Consumer Guidelines for Electric Power Generator Installation and Interconnection

S T A F F R E P O R T

Guidelines for Inverter-Based Micro-Generating Facility (10 kw and Smaller)

October 17, Please contact the undersigned directly with any questions or concerns regarding the foregoing.

Please Refer to Attached Sample Form

Solar Freedom Package - Starter Kit Grid-Interconnected Solar System with Battery Storage

The PV Markets and Industrial Activity In Greece and Bulgaria. Dr. Alexander Zachariou Energy Solutions & Solar Cells Hellas

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

California Low Carbon Fuel Standard Status Report. John D. Courtis October 17, 2011

Solar Charge Controller

SDG&E Customer Distributed Generation Programs. Steve Jaffe Senior Market Advisor Customer Innovations Group September 14, 2009

Caution and Disclaimer The contents of these materials are for information purposes and are provided as is without representation or warranty of any

Egyptian Solar PV Feed-in-Tariff Procedures for Small Scale Projects

CPV Industry Overview

Household Renewable Energy

Publishable Executive Summary (M1-M48)

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Transcription:

Monitoring report form (Version 03.1) Monitoring report Title of the project activity Everbright Suqian & Huaining Bundled Solar PV Power Generation Project_preCDM VER Reference number of the project activity GS 2402 Version number of the monitoring report 02 Completion date of the monitoring report 10/10/2013 CDM Registration date of the project activity 19/03/2012 GS Registration date of the project activity 26/08/2013 Monitoring period number and duration of this monitoring period Pre CDM monitoring period, 01/09/2011-31/03/2012 (both the two days included) Project participant(s) Everbright Photovoltaic Energy (Suqian) Limited (Project owner); Innovative Carbon Investment Corporation Host Party(ies) Sectoral scope(s) and applied methodology(ies) P.R.China Sectoral scope: Scope 1: Energy industries (renewable-/nonrenewable sources) Estimated amount of GHG emission reductions or net anthropogenic GHG removals by sinks for this monitoring period in the registered PDD Actual GHG emission reductions or net anthropogenic GHG removals by sinks achieved in this monitoring period Selected methodology(ies): AMS-I.D. Grid connected renewable electricity generation (Version 17.0) 3,876tCO 2 e 2,343 tco 2 e in this monitoring period 1,040 tco 2 e during the period of 01/09/2011-31/12/2011 1,303 tco 2 e during the period of 01/01/2012-31/03/2012 Version 03.1 Page 1 of 22

SECTION A. Description of project activity A.1. Purpose and general description of project activity Everbright Suqian & Huaining Bundled Solar PV Power Generation Project_preCDM VER (hereinafter referred to as the bundled project) is a grid connected solar photovoltaic (PV) project with a total installed capacity of 10.28MW (1.85MW+2MW+6.43MW) and the estimated annual electricity generation will be 11,095MWh. The bundled project includes 3 small-scale PV power generation projects as follows: Jiangsu Suqian PV Power Plant 1.85MWp Project (hereafter referred to as the Suqian Phase I Project) is estimated to deliver 1,968MWh electricity to East China Power Grid (ECPG) annually with the installed capacity of 1.85MW. The project is built on the roof of Shuanggou and Yanghe Distillery, Suqian city, Jiangsu province, P.R.China. And the estimated annual average emission reductions of the project are 1,556tCO 2 e. Jiangsu Suqian PV Power Plant Phase II 6.43MWp Project (hereafter referred to as the Suqian Phase II Project) is estimated to deliver 6,986MWh electricity to East China Power Grid (ECPG) annually with the installed capacity of 6.43MW. The project is built on the roof of Yanghe Distillery, Suqian city, Jiangsu province, P.R.China. And the estimated annual average emission reductions of the project are 5,522 tco 2 e. Anhui Huaining PV Power Plant 2MWp Project (hereafter referred to as the Huaining Project) is estimated to deliver 2,141MWh electricity to East China Power Grid (ECPG) annually with the installed capacity of 2MW. The project is located in Anqing city, Anhui province, P.R.China. And the estimated annual average emission reductions of the project are 1,692 tco 2 e. As a result, the electricity generated by the bundled project can displace part of the power from the fossil fuel-fired power plants of ECPG, and the expected annual GHG emission reductions are 8,770tCO 2 e. Suqian Phase I Project construction began on 11/2010; and the project was commissioned on 06/12/2010 The operation period of the project is 25 years. Suqian Phase II Project construction began on 10/2011; and the project was commissioned on 22/11/2011. The operation period of the project is 25 years. Huaining Project construction began on 11/2010; and the project was commissioned on 22/06/2011. The operation period of the project is 25 years. The monitoring period is from 01/09/2011-31/03/2012, the emission reduction achieved by Suqian phase I project is 802tCO 2 e, the emission reduction achieved by Suqian phase II project is 773tCO 2 e, and the emission reduction achieved by Huaining project is 768tCO 2 e. As a result, the emission reduction achieved by the bundled project is 2,343tCO 2 e. A.2. Location of project activity The three small-scale projects are located in Suqian city, Jiangsu Province and Anqing city, Anhui province, P. R. China. Each location of plant is presented as follows: Name of Project Lati-tude Longi-tude Suqian Phase I Project 1 32 09'58" ~32 10'05" N (Sihong County) 33 13'36"~33 13'45"N (Yanghe Town) 119 29'47"~119 30'18"E (Sihong County) 118 11'25"~118 11'53"E (Yanghe Town) Suqian Phase II Project 33 47'9"~33 47'30"N 118 21'37" ~118 26'2"E Huaining Project 30 46'14" ~30 46'39" N 116 47'46"~116 48'20"E A.3. Parties and project participant(s) 1 Suqian Phase I Project is built in two locations, one is Sihong County and another is Yanghe Town. Version 03.1 Page 2 of 22

Party involved ((host) indicates a host Party) P.R.China (host) United Kingdom of Great Britain and Northern Ireland Private and/or public entity(ies) project participants (as applicable) Everbright Photovoltaic Energy (Suqian) Limited Innovative Carbon Investment Corporation Indicate if the Party involved wishes to be considered as project participant (Yes/No) No No A.4. Reference of applied methodology 1. Baseline & Monitoring methodology: AMS-I.D.: Grid connected renewable electricity generation (Version 17.0) 2. Reference: Tool to calculate the emission factor for an electricity system (Version 03.0.0) More information on the methodology and tools listed above is available at the following website: http://cdm.unfccc.int/methodologies/sscmethodologies/approved.html A.5. Crediting period of project activity For the bundled project, the renewable crediting period (7 years 3) years is adopted. The first crediting period is from 01/04/2012 to 31/03/2019, and its length is 7 years. SECTION B. Implementation of project activity B.1. Description of implemented registered project activity The bundled project was registered as a GS project on 26/08/2013. The solar cell module, dc-to-ac converter (inverter) and transformer are installed in accordance with the registered PDD. DC electricity energy generated by the Solar cell modules in the sunshine was converted into AC electricity by the dc-to-ac converter (inverter). In the end, the AC electricity was boosted by transformer and delivered to the East China Power Grid. The key technical specifications of the modules and inverters are listed in the following table. Solar Cells Table B-1 Technical parameters of of solar modules and inverters Plant Name Suqian Phase I Project Suqian Phase II Project Huaining Project TW 230 (28) P TW 240 (28)P TWSF-aSi- 95W-1 Manufacturer Tianwei New Tianwei Solution (Beijing) Baoding Tianwei Energy Co., Ltd Solarfilms Co., Ltd (Chengdu) PV Module Co., Ltd Material polycrystalline polycrystalline silicon amorphous silicon film silicon Peak power 230 Wp 240Wp 93.01~98.00 Wp Rated power 29.7V 30.3V 102~113.08V voltage Open circuit 36.7V 37.1V 134.58~142.23V voltage Rated power 7.74A 7.92A 0.93~1.17A current Short circuit 8.72A 8.88A 1.11~1.34A current Version 03.1 Page 3 of 22

ECPG ECPG Number of cells 8,080 Pieces 26,800 Pieces 21,030 Pieces Inverter Sunway TG Sunway TG750- Solar Ocean Sunway TG610-800V- 750-800V-TE 900V-TE 500TL TE Manufacturer Carraro China Drive Systems Carraro China Drive Systems Samil New energy Co., Carraro China Drive Systems Co. Ltd. Co. Ltd. Co. Ltd. Ltd Maximum DC 684.3kW 770kW 570kW 553.7kW Power MPPT voltage 495~820V 495~820V 450~820V 415~760V range Rated capacity 665.1 kw 665.1 kw 500 kw 514.6 kw Rated output 320 V 320 V 270 V 270 V voltage Rated input 1253.4 A 1253.4 A 1200 A 1044.5 A current Number of 3 units 8 units 2 units 4 units units Maximum Efficiency 98.5% 98.5% 98.6% 98.5% The flow diagram of the bundled project is shown below: Inverter Yanghe Substation Polycrystalline silicon Solar cells Inverter Shuanggou Substation Polycrystalline silicon Solar cells Figure B-1 The flow diagram of Suqian Phase I Project Inverter Suqian phase II Substation Polycrystalline silicon Solar cells Figure B-2 The flow diagram of Suqian Phase II Project Version 03.1 Page 4 of 22

ECPG Inverter Huaining Substation Amorphous silicon film Solar cells Figure B-3 The flow diagram of Huaining Project No events or situations occurred during the monitoring period, which may impact the applicability of the methodology. B.2. Post registration changes B.2.1. Temporary deviations from registered monitoring plan or applied methodology There is no temporary deviation from registered monitoring plan or applied methodology for this monitoring period. B.2.2. Corrections There is no correction for this monitoring period. B.2.3. Permanent changes from registered monitoring plan or applied methodology There is no permanent change from registered monitoring plan and applied methodology for this monitoring period. B.2.4. Changes to project design of registered project activity There is no change to project design of registered project activity. B.2.5. Changes to start date of crediting period Not applicable. B.2.6. s of changes specific to afforestation or reforestation project activity Not applicable. SECTION C. Description of monitoring system Version 03.1 Page 5 of 22

The monitoring system is designed and implemented in accordance with the requirements of AMS-I.D. Grid connected renewable electricity generation (Version 17.0) and the registered PDD. 1. Monitoring organization Everbright Photovoltaic Energy (Suqian) Limited has established and maintained the appropriate monitoring and quality control systems, the responsibilities for carrying out these tasks are broadly elaborated in below: CDM project management group General Manager: responsible for the leadership, control for the CDM project management, and external coordination. Management and control center: responsible for the daily implementation of the CDM project monitoring plan and reporting to the group general manager. Data measurement and record: responsible for daily data monitoring and recording according to the monitoring plan. Instrument operation and maintenance: responsible for the installation and testing of the monitoring instruments, their routine operation, regular maintenance and calibrations, troubleshooting and emergency response, and reporting to management and control center Figure C-1 Structure and function of CDM project management group All the staffs had obtained the qualification by corresponding training before working during this monitoring period of the bundled project. 2. Installation of meters Version 03.1 Page 6 of 22

ECPG ECPG ECPG Project site EGin,y,Suqian phase I Yanghe Project consumption M2 Backup line Inverter Yanghe Substation M1' M1 Solar cells Inverter Shuanggou Substation EG ex,y,suqian phase I EG in,y,suqian phase I M3 M3' Solar cells Shuanggou Project consumption M4 Backup line M Meter Inverter EGin,y,Suqian phase I Figure C-2 Monitoring diagram of Suqian Phase I Project Project site EGin,y,Suqian phase II Project consumption M6 Backup line Inverter Suqian phase II Substation M5' M5 Solar cells EG ex,y,suqian phase II EG in,y,suqian phase II Figure C-3 Monitoring diagram of Suqian Phase II Project Version 03.1 Page 7 of 22

ECPG Project site EGin,y,Huaining Project consumption M8 Backup line Inverter Huaining Substation M7' M7 Solar cells EG ex,y,huaining EG in,y,huaining Figure C-4 Monitoring diagram of Huaining Project For Suqian Phase I Project, the electricity exported by the project (EG ex,y,suqian phase I ) are measured by the bidirectional electricity meter M1 and M3, which is installed at the gate way of the project site. The electricity imported from the grid (EG in,y,suqian phase I ) are measured by the bidirectional electricity meter M1 and M3 installed at gate way of the project site, and the unidirectional electricity M2 and M4 installed at the project site. The M1and M3 are the main meters, and the check meters M1 and M3 are also installed at the gate way of the project site. The net electricity used for ERs calculation of Suqian phase I project could be calculated as the difference between EG ex,y,suqian phase I and EG in,y,suqian phase I. For Suqian Phase II Project, the electricity exported by the project (EG ex,y,suqian phase II ) is measured by the bidirectional electricity meter M5, which is installed at the gate way of the project site. The electricity imported from the grid (EG in,y,suqian phase II ) are measured by the bidirectional electricity meter M5 installed at gate way of the project site, and the unidirectional electricity M6 installed at the project site. The M5 is the main meter, and the check meter M5 is also installed at the gate way of the project site. The net electricity used for ERs calculation of Suqian phase II project could be calculated as the difference between EG ex,y,suqian phase II and EG in,y,suqian phase II. For Huaining Project, the electricity exported by the project (EG ex,y,huaining ) is measured by the bidirectional electricity meter M7, which is installed at the gate way of the project site. The electricity imported from the grid (EG in,y,huaining ) are measured by the bidirectional electricity meter M7 installed at gate way of the project site, and the unidirectional electricity M8 installed at the project site. The M7 is the main meter, and the check meter M7 is also installed at the gate way of the project site. The net electricity used for ERs calculation of Huaining project could be calculated as the difference between EG ex,y,huaining and EG in,y,huaining. 3. Data record and management system The readings of the meters start from the first day of every month and end at 24:00 of the last day of every month are recorded. Specific staff was appointed to take the overall responsibility for keeping all the data collected as part of monitoring and kept for two years after the end of the last crediting period. Electronic data written data and documents, including records for cross-checking of data were regularly copied and kept at least for two years after the end of the last crediting period. 4. Quality assurance and quality control (QA/QC) The electricity supplied and consumed by the Project shall be cross-checked with records for sold/purchased electricity (e.g. invoices/receipts). Problem occurred in monitoring and measurement process will be recorded and reported to the Group General Manager. Should the reading of the main meter be inaccurate by more than the allowable error, or otherwise functioned improperly, the net generation output shall be determined as follows: a) Reading the data monitored by check meter; Version 03.1 Page 8 of 22

b) If the reading of the check meter is still inaccurate, the project owner and the grid company shall jointly prepare a reasonable and conservative estimate of the correct reading based on the plant consumption rate, and provide sufficient evidence that this estimation is reasonable and conservative when DOE undertakes verification. There is no inaccuracy of the meters occurred in this monitoring period. SECTION D. Data and parameters D.1. Data and parameters fixed ex ante or at renewal of crediting period (Copy this table for each piece of data and parameter.) EF CO2,grid,y Data / Parameter: Unit: tco 2 e/mwh Description: CO 2 Emission factor of the grid Source of data: Calculated base on Chinese DNA s publication Value(s) applied): 0.7905 Purpose of data: Calculation of baseline emissions Additional comment: It is fixed during the first crediting period and should be updated in the second crediting period. D.2. Data and parameters monitored (Copy this table for each piece of data and parameter.) Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: Measuring/ Reading/ Recording frequency: Calculation method (if applicable): EG facility,y,suqian phase I MWh Quantity of net electricity supplied to the grid by Suqian phase I project in year y Calculated Calculated based on the measured parameters of EG ex,y,suqian phase I and EG in,y,suqian phase I 1,014.346 The parameter will be calculated based on the following measured parameters of EG ex,y,suqian phase I and EG in,y,suqian phase I, EG EG EG i.e. facility, y,suqian phase I ex,y,suqian phase I in,y,suqian phase I QA/QC procedures: Measurement results shall be cross checked with records for sold/purchased electricity (e.g. invoices/receipts). Purpose of data: Calculation of baseline emissions Additional comment: - Data / Parameter: Unit: Description: Measured/ EG ex,y,suqian phase I MWh Electricity supplied to the grid by Suqian phase I project in year y Measured Version 03.1 Page 9 of 22

Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring Measured by electricity meter, and calculated as the sum of the measurement results of electricity meter M1 and M3 1,036.639 equipment: Meter M1 ZMD402CT44.0457 Serial number 95411219 Meter M1 (check meter of M1) ZMD405CR44.0007 Accuracy class 0.5S Serial number 96336841 Meter M3 (New meter) ZMD402CT44.0457 Serial number 97551690 Calibration validity Calibrated on 26/03/2011 valid to 25/03/2012; Version 03.1 Page 10 of 22

Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Meter M3 (check meter of M3) ZMD402CT44.0457 Serial number 96213047 Continuously measured and monthly recorded respectively. The electricity meter M1, M1, M3 and M3 are calibrated annually according to the related national standard. Cross check measurement results with records for sold electricity. Calculation of baseline emissions Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: EG in,y,suqian phase I MWh Electricity consumed by Suqian phase I project importing from the grid in year y Measured Measured by electricity meter(s), and calculated as the sum of the measurement results of electricity meter M1, M2, M3 and M4 22.293 Meter M1 ZMD402CT44.0457 Serial number 95411219 Version 03.1 Page 11 of 22

Meter M1 (check meter of M1) ZMD405CR44.0007 Accuracy class 0.5S Serial number 96336841 Meter M2 DTSD341 Accuracy class 0.5S Serial number 1011048976000002 Meter M3 (New meter) ZMD402CT44.0457 Serial number 97551690 Calibration validity Calibrated on 26/03/2011 valid to 25/03/2012; Meter M3 (check meter of M3) ZMD402CT44.0457 Serial number 96213047 Version 03.1 Page 12 of 22

Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Meter M4 DTSD341 Accuracy class 0.5S Serial number 1011048976000001 Continuously measured and monthly recorded respectively. The electricity meter M1, M1, M2, M3, M3 and M4 are calibrated annually according to the related national standard. Cross check measurement results with records for purchased electricity. Calculation of baseline emissions Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: Measuring/ Reading/ Recording frequency: Calculation method (if applicable): EG facility,y,suqian phase II MWh Quantity of net electricity supplied to the grid by Suqian phase II project in year y Calculated Calculated based on the measured parameters of EG ex,y,suqian phase II and EG in,y,suqian phase II 978.456 The parameter will be calculated based on the following measured parameters of EG ex,y,suqian phase II and EG in,y,suqian phase II, EG EG EG i.e. facility, y, Suqian phase II ex,y,suqian phase II in,y,suqian phase II QA/QC procedures: Measurement results shall be cross checked with records for sold/purchased electricity (e.g. invoices/receipts). Purpose of data: Calculation of baseline emissions Additional comment: - Data / Parameter: Unit: Description: Measured/ EG ex,y,suqian phase II MWh Electricity supplied to the grid by Suqian phase II project in year y Measured Version 03.1 Page 13 of 22

Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: Measured by electricity meter 1,009.900 Meter M5 DTZ876 Serial number 1400341751 Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Meter M5 (check meter of M5) DTZ876 Serial number 1400341777 Continuously measured and monthly recorded respectively. The electricity meter M5 and M5 are calibrated annually according to the related national standard. Cross check measurement results with records for sold electricity. Calculation of baseline emissions Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: EG in,y,suqian phase II MWh Electricity consumed by Suqian phase II project importing from the grid in year y Measured Measured by electricity meter(s), and calculated as the sum of the measurement results of electricity meter M5 and M6 31.444 Version 03.1 Page 14 of 22

Monitoring equipment: Meter M5 DTZ876 Serial number 1400341751 Meter M5 (check meter of M5) DTZ876 Serial number 1400341777 Meter M6 DTZY532-A Accuracy class 1.0 Serial number 1400205838 Calibration validity Calibrated on 22/09/2011 valid to 21/09/2012; Calibrated on 20/09/2012 valid to 19/09/2013. Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Continuously measured and monthly recorded respectively. The electricity meter M5, M6 and M5 are calibrated annually according to the related national standard. Cross check measurement results with records for purchased electricity. Calculation of baseline emissions Data / Parameter: Unit: Description: Measured/ Calculated / EG facility,y,huaining MWh Quantity of net electricity supplied to the grid by Huaining project in year y Calculated Version 03.1 Page 15 of 22

Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: Measuring/ Reading/ Recording frequency: Calculation method (if applicable): Calculated based on the measured parameters of EG ex,y,huaining and EG in,y,huaining 972.038 The parameter will be calculated based on the following measured parameters of EG ex,y,huaining and EG in,y,huaining, i.e. EG EG EG facility, y, Huaining ex,y,huaining in,y, Huaining QA/QC procedures: Measurement results shall be cross checked with records for sold/purchased electricity (e.g. invoices/receipts). Purpose of data: Calculation of baseline emissions Additional comment: - Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: EG ex,y,huaining MWh Electricity supplied to the grid by Huaining project in year y Measured Measured by electricity meter 991.758 Meter M7 AINRTAL/3 100V 3 1(10)A Serial number 02081993 Calibration validity Calibrated on 17/05/2011 valid to 16/05/2012; Calibrated on 27/01/2012 valid to 26/01/2013. Version 03.1 Page 16 of 22

Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Meter M7 AINRTAL/3 100V 3 1(10)A Serial number 02082012 Calibration validity Calibrated on 17/05/2011 valid to 16/05/2012; Calibrated on 27/01/2012 valid to 26/01/2013. Continuously measured and monthly recorded respectively. The electricity meter M7 and M7 are calibrated annually according to the related national standard. Cross check measurement results with records for sold electricity. Calculation of baseline emissions Data / Parameter: Unit: Description: Measured/ Calculated / Default: Source of data: Value(s) of monitored parameter: Monitoring equipment: EG in,y,huaining MWh Electricity consumed by Huaining project importing from the grid in year y Measured Measured by electricity meter(s), and calculated as the sum of the measurement results of electricity meter M7and M8 19.720 Meter M7 AINRTAL/3 100V 3 1(10)A Serial number 02081993 Calibration validity Calibrated on 17/05/2011 valid to 16/05/2012; Calibrated on 27/01/2012 valid to 26/01/2013. Version 03.1 Page 17 of 22

Measuring/ Reading/ Recording frequency: Calculation method (if applicable): QA/QC procedures: Purpose of data: Additional comment: - Meter M7 (check meter of M7) AINRTAL/3 100V 3 1(10)A Serial number 02082012 Calibration validity Calibrated on 17/05/2011 valid to 16/05/2012; Calibrated on 27/01/2012 valid to 26/01/2013. Meter M8 DTSD341 Accuracy class 1.0 Serial number 1012050835000020 Calibration validity Calibrated on 10/01/2011 valid to 09/01/2012; Calibrated on 21/10/2011 valid to 20/10/2012. Continuously measured and monthly recorded respectively. The electricity meter M7, M7 and M8 are calibrated annually according to the related national standard. Cross check measurement results with records for purchased electricity. Calculation of baseline emissions D.3. Implementation of sampling plan SECTION E. Calculation of emission reductions or GHG removals by sinks E.1. Calculation of baseline emissions or baseline net GHG removals by sinks The baseline emissions calculated as follows: BE y EGBL, y EFCO 2, grid, y (1) Where: BEy = Baseline emissions in year y (tco 2 ) EG BL, y = Quantity of net electricity supplied to the grid as a result of the implementation o Version 03.1 Page 18 of 22

the CDM project activity in year y (MWh); EF CO2,grid,y = CO 2 Emission Factor of the grid in year y. EG BL, y EG EG ex,y,suqian phase I EG in,y,suqian phase I EG ex,y,suqian phase II EG in,y,suqian phase II EG EG ex,y,huaining facility, y,suqian phase I in,y,huaining EG facility, y,suqian phase II EG facility, y,huaining (2) Where: EG facility,y,suqian phase I = Quantity of net electricity supplied to the grid by Suqian Phase I Project in year y (MWh); EG facility,y,suqian phase II = Quantity of net electricity supplied to the grid by Suqian Phase II Project in year y (MWh); EG facility,y, Huaining = Quantity of net electricity supplied to the grid by Huaining Project in year y (MWh); EG ex,y,suqian phase I = Electricity supplied to the grid by Suqian phase I project in year y (MWh); EG in,y,suqian phase I = Electricity consumed by Suqian phase I project importing from the grid in year y (MWh); EG ex,y,suqian phase II = Electricity supplied to the grid by Suqian phase II project in year y (MWh); EG in,y,suqian phase II = Electricity consumed by Suqian phase II project importing from the grid in year y (MWh). EG ex,y,huaining = Electricity supplied to the grid by Huaining project in year y (MWh); EG in,y,huaining = Electricity consumed by Huaining project importing from the grid in year y (MWh). The monthly electricity data of Suqian phase I project are listed in Table E-1 as following: Table E-1 Net electricity supplied by Suqian phase I Project Period EG ex,y,suqian phase I (MWh) EG in,y,suqian phase I (MWh) EG facility,y,suqian phase I (MWh) 01/09/2011-30/09/2011 165.677 3.203 162.474 01/10/2011-31/10/2011 171.544 3.068 168.476 01/11/2011-30/11/2011 113.337 3.328 110.009 01/12/2011-31/12/2011 151.008 3.405 147.603 01/01/2012-31/01/2012 122.065 3.482 118.583 01/02/2012-29/02/2012 147.356 2.900 144.456 01/03/2012-31/03/2012 165.652 2.907 162.745 Total 1,036.639 22.293 1,014.346 The monthly electricity data of Suqian phase II project are listed in Table E-2 as following: Table E-2 Net electricity supplied by Suqian phase II Project Period EG ex,y,suqian phase II (MWh) EG in,y,suqian phase II (MWh) EG facility,y,suqian phase II (MWh) 01/09/2011-30/09/2011 0.000 0.000 0.000 01/10/2011-31/10/2011 0.000 0.000 0.000 01/11/2011-30/11/2011 0.000 0.000 0.000 01/12/2011-31/12/2011 71.400 6.245 65.155 01/01/2012-31/01/2012 223.100 9.016 214.084 01/02/2012-29/02/2012 437.400 7.238 430.162 01/03/2012-31/03/2012 278.000 8.945 269.055 Total 1,009.900 31.444 978.456 Version 03.1 Page 19 of 22

The monthly electricity data of Huaining project are listed in Table E-3 as following: Table E-3 Net electricity supplied by Huaining Project Period EG ex,y,huaining (MWh) EG in,y,huaining (MWh) EG facility,y,huaining (MWh) 01/09/2011-30/09/2011 198.750 0.678 198.072 01/10/2011-31/10/2011 180.900 2.470 178.430 01/11/2011-30/11/2011 154.581 2.538 152.043 01/12/2011-31/12/2011 136.416 3.231 133.185 01/01/2012-31/01/2012 85.884 3.489 82.395 01/02/2012-29/02/2012 99.174 3.405 95.769 01/03/2012-31/03/2012 136.053 3.909 132.144 Total 991.758 19.720 972.038 The baseline emissions of the bundled project are listed in Table E-4 as following: Table E-4 Baseline emission of the bundled project Period EG BL, y (MWh) EF CO2,grid,y (tco 2 e/mwh) BEy (tco 2 e) 01/09/2011-30/09/2011 360.546 0.7905 285.011 01/10/2011-31/10/2011 346.906 0.7905 274.230 01/11/2011-30/11/2011 262.052 0.7905 207.152 01/12/2011-31/12/2011 345.943 0.7905 273.468 01/01/2012-31/01/2012 415.062 0.7905 328.107 01/02/2012-29/02/2012 670.387 0.7905 529.941 01/03/2012-31/03/2012 563.944 0.7905 445.798 Total 2,964.840-2,343 E.2. Calculation of project emissions or actual net GHG removals by sinks According to AMS-I.D. (version 17.0) and the registered PDD, the project emission of the bundled project is zero. E.3. Calculation of leakage According to AMS-I.D. (Version 17.0), no leakage is need to be considered. E.4. Summary of calculation of emission reductions or net anthropogenic GHG removals by sinks Item Baseline emissions or baseline net GHG removals by sinks (t CO 2 e) Project emissions or actual net GHG removals by sinks (t CO 2 e) Leakage (t CO 2 e) Total 2,343 0 0 2,343 Emission reductions or net anthropogenic GHG removals by sinks (t CO 2 e) E.5. Comparison of actual emission reductions or net anthropogenic GHG removals by sinks with estimates in registered PDD Version 03.1 Page 20 of 22

Item Emission reductions or GHG removals by sinks (t CO 2 e) Values estimated in exante Actual values achieved calculation of during this monitoring registered PDD period 3,876 2 2,343 E.6. Remarks on difference from estimated value in registered PDD For Suqian Phase I Project, the actual emission reductions achieved is 802tCO 2 e in this monitoring period, which is lower than the estimated emission reductions of 908tCO 2 e(=1,556/365*213tco 2 e) in the registered PDD. For Suqian Phase II Project, the actual emission reductions achieved is 773tCO 2 e in this monitoring period, which is lower than the estimated emission reductions of 1,981tCO 2 e(=5,522/365*131tco 2 e) in the registered PDD. For Huaining Project, the actual emission reductions achieved is 768tCO 2 e in this monitoring period, which is slightly higher than the estimated emission reductions of 987tCO 2 e(=1,692/365*213tco 2 e) in the registered PDD. The actual emission reductions achieved by the bundled project during this monitoring period are lower than the estimated emission reductions in the registered PDD. E.7. Actual emission reductions or net anthropogenic GHG removals by sinks during the first commitment period and the period from 1 January 2013 onwards Item Emission reductions or GHG removals by sinks (t CO 2 e) Actual values achieved up to 31 December 2012 2,343 0 Actual values achieved from 1 January 2013 onwards - - - - - 2 Suqian Phase II Project was commissioned on 22/11/2011, and the operation days are 131 in this monitoring period. According to the registered PDD, the annually emission reduction of Suqian Phase I Project is 1,556tCO 2e, and 5,522tCO 2e of Suqian Phase II Project, and 1,692tCO 2e of Huaining Project. Then the emission estimated in ex-ante calculation of registered PDD is calculated as 1,556/365*213+5,522/365*131+1,692/365*213=3,876tCO 2e. Version 03.1 Page 21 of 22

Document information Version Date Description 03.1 2 January 2013 Editorial revision to correct table in section E.5. 03.0 3 December 2012 Revision required to introduce a provision on reporting actual emission reductions or net anthropogenic GHG removals by sinks for the period up to 31 December 2012 and the period from 1 January 2013 onwards (EB70, Annex 11). 02.0 13 March 2012 Revision required to ensure consistency with the "Guidelines for completing the monitoring report form" (EB 66, Annex 20). 01 28 May 2010 EB 54, Annex 34. Initial adoption. Decision Class: Regulatory Document : Form Business Function: issuance Keywords: monitoring report, performance monitoring Version 03.1 Page 22 of 22