CHARACTERISTICS OF A RECIPROCATING PUMP FOR LOW-COST SUSTAINABLE WATER HYDRAULIC TECHNOLOGY DEMONSTRATOR

Similar documents
Slip flow coefficient analysis in water hydraulics gear pump for environmental friendly application

NUMERICAL ANALYSIS OF ELASTOHYDRODYNAMIC LUBRICATION WITH BIO-BASED FLUIDS DEDI ROSA PUTRA CUPU UNIVERSITI TEKNOLOGI MALAYSIA

APPLICATION OF DEMAND SIDE MANAGEMENT STRATEGIES TO REDUCE ENERGY CONSUMPTION IN UNIVERSITY BUILDINGS NAJAATUL FARIHAH BINTI HAMIDI

OPTIMAL LOCATION OF FACTS FOR ATC ENHANCEMENT BY USING SENSITIVITY ANALYSIS RAIMON OMAR AL SHAIKH SALEM

HAZILA BINTI NAYAN. A project report submitted in partial fulfillment of the requirement for the award of the Degree of Master of Manufacturing

ENERGY BALANCE STUDY FOR 4 STROKE GASOLINE ENGINE ANALYSES ABDULLAH SHARIFFUDIN MOHAMAD BACHELOR OF MECHANICAL ENGINEERING UNIVERSITI MALAYSIA PAHANG

OPTIMAL ANTI LOCK BRAKING SYSTEM WITH REGENERATIVE BRAKING IN HYBRID ELECTRIC VEHICLE DANA DEHGHANI UNIVERSITI TEKNOLOGI MALAYSIA

This item is protected by original copyright

OPTIMAL LOCATION OF THYRISTOR CONTROLLED SERIES COMPENSATOR USING SENSITIVITY APPROACH NEW HUANG CHIN UNIVERSITI TEKNOLOGI MALAYSIA

FINITE ELEMENT (FE) MODEL OF BRAKE INSULATOR IN REDUCING BRAKE SQUEAL NOISE FOR MOTORCYCLES MUNDHER FADHIL ABDULRIDHA UNIVERSITI TEKNOLOGI MALAYSIA

Multi Body Dynamic Analysis of Slider Crank Mechanism to Study the effect of Cylinder Offset

INSTRUCTION: This paper consists of SIX (6) structured questions. Answer any FOUR (4) questions.

COMPARISON OF AUTOMATIC AND CVT TRANSMISSION FOR A CAR UNDER 1 LITER ENGINE

DEVELOPMENT OF MICROHYDRO GENERATOR SYSTEM AHMAD ZUBAIDI BIN ABDUL MD RANI UNIVERSITI MALAYSIA PAHANG

MODELING OF ELECTRIC DOUBLE LAYER CAPACITOR FATHIN ASILA BINTI MOHD PABLI UNIVERSITI TEKNOLOGI MALAYSIA

THE STUDY ON THE IMPACT OF CONSTANT POWER LOAD TO A DIRECT CURRENT POWER SYSTEM DRIVEN BY PHOTOVOLTAIC, WIND - THYRISTOR RECTIFIER AND LINEAR SOURCES

UNIVERSITI MALAYSIA PAHANG BORANG PENGESAHAN STATUS TESIS

UNIVERSITI MALAYSIA PAHANG BORANG PENGESAHAN STATUS TESIS

AERODYNAMICS COOLING OF DISC BRAKE ROTOR MOHD RAUS BIN ZAINUDIN UNIVERSITI TEKNIKAL MALAYSIA MELAKA

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

A pump is a machine used to move liquid through a piping system and to raise the pressure of the liquid.

CURRENT CARRYING CAPABILTY OF POLYESTER CARBON COATED FOR ELECTRICAL CONDUCTOR MOHD HAIDIR BIN MANAF UNIVERSITI TEKNOLOGI MALAYSIA

DEVELOPMENT OF ELECTRICAL DISCHARGE MACHINING POWER GENERATOR MUHD ABU BAKAR BIN MUHD RADZI

INTERCONNECTION POSSIBILITIES FOR THE WORKING VOLUMES OF THE ALTERNATING HYDRAULIC MOTORS

GLYCERINE PITCH FROM GLYCERINE CONCENTRATION PROCESS AS ALTERNATIVE FUEL FOR BOILER OPERATIONS KIRUBAHARAN A/L MERAPAN

ZULHILMI AFIQ BIN ZULKIFLE

UNIVERSITI PUTRA MALAYSIA EXPERIMENTAL AND SIMULATED PERFORMANCE STUDY OF A SMALL-SCALE GAS TURBINE ENGINE USING JET A-1 AND PALM OIL BIODIESEL BLENDS

CONVERSION OF GLYCEROL TO METHANOL OVER COPPER AND NICKEL SUPPORTED ON HZSM-5 ZEOLITE BY HYDROTHERMAL PROCESS NURUL SYUHADA BT SPALIE

Analysis of Torsional Vibration in Elliptical Gears

DESIGN, DETAIL ANALYSIS AND PERFORMANCE TESTING OF UAV PROPULSION SYSTEM CHE MUHAMMAD RIDHWAN BIN CHE HASHIM

DESIGN AND FABRICATION OF POLYVINYL CHLORIDE TIE-ROD CYLINDER FOR LOW PRESSURE WATER HYDRAULIC SYSTEM

DISC BRAKE SQUEAL GENERATION DURING DRY AND WET CONDITIONS MUNEER NAJI WAHEED UNIVERSITI TEKNOLOGI MALAYSIA

Simulation Method of Hydraulic Confined Piston Engine

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

BORANG PENGESAHAN STATUS TESIS

DESIGN AND DEVELOPMENT A SMALL STIRLING ENGINE NURUL HUDA BINTI BASO

ARAHAN: Kertas soalan ini mengandungi ENAM (6) soalan esei. Jawab EMPAT (4) soalan sahaja.

Hydraulic Pumps Classification of Pumps

WIRELESS SOLAR CHARGER SITI NOR AZURA BINTI RAHMAN

Available online at ScienceDirect. Procedia Engineering 68 (2013 ) 70 76

SUPERVISOR DECLARATION

DESIGN AND SIMULATION OF PRECHAMBER WITH HIGH PRESSURE CNG INJECTOR SYSTEM FOR SINGLE CYLINDER FOUR STROKE ENGINE MOHD FADZLI BIN MAT LAZIM

SPRAY SIMULATION OF HYDROGEN FUEL FOR SPARK IGNITION ENGINE USING COMPUTATIONAL FLUID DYNAMIC (CFD)

THE NUMERICAL SIMULATION ANALYSIS OF KEY STRUCTURES OF INTEGRATED POWER SUPPLY IN MOTOR-PUMP

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

TECHNOLOGY AND INNOVATION MANAGEMENT AWARENESS AND PRACTISE A CASE STUDY IN BRITISH AMERICAN TOBACCO GSD (KL) SDN BHD

SIMULATION OF AUTOMATIC STEERING SYSTEM ZULFADLI BIN KASMANI UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Seals Stretch Running Friction Friction Break-Out Friction. Build With The Best!

ARC FLASH ANALYSIS STUDY IN INDUSTRY HARNA A/P ELAVARASU

FABRICATION OF A PROTOTYPE LOW POWER MOTOR FOR INDOOR VENTILATION SIMON THEOPHYLUS YUSUF

INSTRUCTION: This section consists of SIX (6) essay questions. Answer FOUR (4) questions only.

Hydraulic drives market trends and offerings

Simulation of Performance Parameters of Spark Ignition Engine for Various Ignition Timings

Design and Stress Analysis of Crankshaft for Single Cylinder 4-Stroke Diesel Engine

Balancing of Reciprocating Parts

TUTORIAL QUESTIONS FOR THE INDUSTRIAL HYDRAULICS COURSE TEP 4205

Power Performance and Exhaust Gas Analyses of Palm Oil and Used Cooking Oil Methyl Ester as Fuel for Diesel Engine

HYDROSTATIC TRANSMISSION AS AN ALTERNATIVE TO CONVENTIONAL GEARBOX

THE DESIGN OF A TORQUE FEEDBACK CONTROLLER USING PID CONTROLLER FOR AN UPPER LIMB ROBOTIC ARM KARTIKESU A/L VIJAYAN

Signature Supervisor name Date

A FREQUENCY CONTROLLER USING FUZZY IN ISOLATED MICROGRID SYSTEM

MODELLING OF THROUGH-THE-ROAD HYBRID ELECTRIC VEHICLE OKE PAUL OMEIZA

Farlister Glenn Gainus

Structural Analysis Of Reciprocating Compressor Manifold

DESIGN OF SINGLE CYLINDER VARIABLE COMPRESSION RATIO 4-STROKE ENGINE FIRDAUS HAIKAL BIN RAMLI

INSTRUCTION: This section consists of SIX (6) structure questions. Answer FOUR (4) questions only.

OPTIMIZATION ON FUEL GAS OPERATION FOR COMBINED CYCLE POWER PLANT MOHD IZAMUDDIN BIN MAHMUD

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL HYDRAULIC AND PNEUMATIC MOTORS. This work covers part of outcome 2 of the Edexcel standard module:

FLUID AND HEAT FLOW PERFORMANCE IN HEAT EXCHANGER NURLIYANA BINTI MOHD NADZRI

Noise Reduction in a Reciprocating Compressor by Optimizing the Suction Muffler

CHAPTER 8 EFFECTS OF COMBUSTION CHAMBER GEOMETRIES

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

CONTROL OF INVERTED PENDULUM-CART SYSTEM BASED ON FUZZY LOGIC APPROACH HASRULNIZAM BIN HASHIM

ELECTRIC CAR VOLTAGE MONITORING SYSTEM NAJMI AZFAR BIN MOHD ROSLI

The Performance Optimization of Rolling Piston Compressors Based on CFD Simulation

ROBUST ELECTRONIC BRAKE FORCE DISTRIBUTION IN HYBRID ELECTRIC VEHICLES YEOH WEI CHERNG UNIVERSITI TEKNOLOGI MALAYSIA

COMPARISON OF PRESENT-DAY LONG-STROKE SUCKER-ROD PUMPING SYSTEMS

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Clearance Loss Analysis in Linear Compressor with CFD Method

COMPARISON OF PROPELLER TYPE B-SERIES AND AU-OUTLINE GAWN SERIES FOR IMPROVING ON SUBMARINE PROPULSION PERFORMANCE USING CFD

Air Flow Analysis of Four Stroke Direct Injection Diesel Engines Based on Air Pressure Input and L/D Ratio

SMART SUN TRACKING WITH AUTOMATED CLEANING SYSTEM FOR PV MODULES AMIRAH AFIQAH BINTI AHMED

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic

Application of Simulation-X R based Simulation Technique to Notch Shape Optimization for a Variable Swash Plate Type Piston Pump

MODIFICATION OF SLIDER CRANK MECHANISM AND STUDY OF THE CURVES ASSOCIATED WITH IT

Technology, Xi an , China

PREDICTION STUDIES FOR THE PERFORMANCE OF A SINGLE CYLINDER HIGH SPEED SI LINEAR ENGINE MOHD NORDIN BIN ZAZALLI

THE ANALYSIS OF THE FORCES THAT ACT ON THE MOTORCYCLE BRAKE PEDAL DURING EMERGENCY BRAKE

UNIVERSITI PUTRA MALAYSIA REDUCTION OF TOTAL HARMONIC REDUCTION IN TORQUE CHARACTERISTICS IN TWO-PHASE SIDE BY SIDE BRUSHLESS DC MOTOR NG SENG SHIN

Influence of Cylinder Bore Volume on Pressure Pulsations in a Hermetic Reciprocating Compressor

INSTRUCTION : This section consists of SIX (6) structured questions. Answer any FOUR (4) only.

CONTROL OF ENERGY CONVERSION IN A HYBRID WIND AND ULTRACAPACITOR ENERGY SYSTEM MAJID ABDULLATEEF ABDULLAH UNIVERSITI TEKNOLOGI MALAYSIA

10/29/2018. Chapter 16. Turning Moment Diagrams and Flywheel. Mohammad Suliman Abuhaiba, Ph.D., PE

Investigation of micro surface shaping effects for improving the lubrication performance of water based high pressure external gear machines

AT 2303 AUTOMOTIVE POLLUTION AND CONTROL Automobile Engineering Question Bank

FEM ANALYSIS OF CONNECTING ROD FOR STATIONARY ENGINE. Republic

A New Device to Measure Instantaneous Swept Volume of Reciprocating Machines/Compressors

B.Tech. MECHANICAL ENGINEERING (BTMEVI) Term-End Examination December, 2012 BIMEE-007 : ADVANCED DYNAMICS OF MACHINE

Numerical Simulation and Performance Analysis of Rotary Vane Compressors for Automobile Air Conditioner

THE DEVELOPMENT OF ADAPTIVE LIGHTING SYSTEM FOR MOTORCYCLES ASYRAF BIN AMIR

Transcription:

CHARACTERISTICS OF A RECIPROCATING PUMP FOR LOW-COST SUSTAINABLE WATER HYDRAULIC TECHNOLOGY DEMONSTRATOR Universiti Teknikal Malaysia Melaka Abstract An investigation on water-based reciprocating triplex piston pump is being conducted, as a low cost solution in substituting traditional oil hydraulics to water hydraulics. Triplex pumps are used in applications that require continuous pumping, and generally are capable of handling a wide range of fluid types, including corrosive fluids, abrasive fluids, and slurries containing relatively large particulates. Thus, an evaluation by using simple simulation process has been conducted on the volumetric efficiency, in order to understand its ability in energy-efficient system. In this paper, the results of a simulated study on a positive displacement triplex piston pump are presented. The result concludes that the use of water is relatively efficient if the slip factor is maintained to 0.003, with system pressure from 10 to 40 bar. Keywords: Water Hydraulics, Triplex Piston Pump, Energy Efficient 75

CIRI PAM SALINGAN SEBAGAI PENUNJUK TEKNOLOGI HIDRAULIK AIR KOS RENDAH Universiti Teknikal Malaysia Melaka Abstrak Siasatan ke atas pam salingan tiga omboh berasaskan air dijalankan, sebagai penyelesaian kos rendah dalam menggantikan hidraulik minyak mineral untuk hidraulik air. Pam tiga omboh digunakan dalam aplikasi yang memerlukan pam berterusan dan pada amnya adalah mampu mengendalikan pelbagai jenis cecair, termasuk cecair yang menghakis, cecair yang kasar dan buburan yang mengandungi zarah yang agak besar. Oleh itu, penilaian dengan menggunakan proses simulasi mudah telah dijalankan ke atas kecekapan dan isipadu untuk memahami keupayaan dalam sistem cekap tenaga. Dalam kertas ini, keputusan kajian simulasi pada pam anjakan tiga omboh positif dibentangkan. Hasilnya menyimpulkan bahawa penggunaan air adalah agak berkesan jika slip factor dikekalkan pada nilai 0003, dengan tekanan sistem 10-40 bar Kata kunci: Hidraulik Air, Pam Tiga Omboh, Cekap Tenaga 76

1.0 INTRODUCTION Characteristics of a Reciprocating Pump for Low-Cost Sustainable Water Hydraulic Technology Demonstrator The use of water hydraulics promotes possibility in developing fluid power systems with sustainable, energy efficient and environmental friendly elements. In this case, water hydraulics plays a role as a technology, which is using tap water or water-based fluids as the working fluid to transmit energy and power. The aim of using water as the hydraulic medium is to transfer the energy, power and the resource sustainably, at a rate that does not compromise the natural environment. The use of non-renewable resources such as fossil fuels, natural gas and coal has to be decreased, in promoting eco-friendly technology for a greener future. This involves the use of hydraulic oil which is acquired from petroleum-based mineral oil. The use of water is vital in developing sustainable fluid power system. Simultaneously, water characteristics involving hygiene, safety and low maintenance cost provide interesting perspectives for design engineers due to concern over hydraulic fluid disposal, contamination, costly maintenance and flammability. The impressive uniqueness of energy and power transmission has also brought the technology to wider scopes of application. The challenging problems which normally occur in water hydraulic system such as low lubricity and highly corrosive properties can be lowered down by the usage of a water sprayer by the triplex piston pump. Water is significantly different from oil, which at the same time can provide advantages in one aspect while producing disadvantages in other aspects. Water hydraulics can offer a design for hygiene solution in various industries, as demonstrated by the development of water hydraulics driven burger machine, beef cutter and ice filled machine in the food processing industry, and the use of environmentfriendly industrial scissor lift and waste packer lorry. Therefore, based on the current reality, this paper investigates the effect of using a triplex piston pump on a water hydraulic technology demonstrator. The demonstrator will be use to promote the usage of water hydraulic in various area such as food processing, robotics and in education. Pump is the most important component in water hydraulics system. The triplex piston pump used in this study is a spray pump with maximum pressure up to 40 bars which is usually used for car wash. This pump has a built in pressure regulator with an electric motor as its prime mover. The size of the pump is 84 cm x 50 cm x 50 cm. A simulation study is being conducted on this triplex piston pump in order to determine the volumetric efficiency parameter of suction and discharge and the water flow characteristics, under the influence of various pump speed and dimensions. 77

2.0 MATHEMATICAL MODELING AND ANALYSIS Figure 1 illustrates a reciprocating pump that basically consists of a cylinder, piston, suction and delivery valve. The pump used in this study is considered as a triplex single-acting pump. Generally, a triplex piston pump exhibit typical flow variations in the delivery and suction caused by the rotary motion of the electric motor that drives the displacement elements which is piston or plungers in three cylinders. In the suction stroke event, the piston moves to create vacuum in the cylinder. This vacuum causes the suction valve to open, and thus allowing water to enter the cylinder. In the event of a delivery stroke, the piston s opposite movement increases the pressure inside the cylinder. The increment of pressure causes the suction valve to close and delivery valve to open, where the water is forced into the outlet pipe. Figure 1 Triplex Piston Pump Figure 2 Reciprocating Pump Geometry In Figure 2, the piston is connected to the rotating crank by a crank shaft. It is obvious that the piston will move, forward and backward, thus creating a simple harmonic motion. Therefore the velocity of the piston will not be uniform at all points. It will be zero at its extreme ends, whereas it will be at maximum on its centre. In addition, the piston will also have acceleration at the beginning and retardation at end of every stroke. This acceleration and retardation of piston causes a variation pressure in the cylinder and consequently in the suction and delivery pipes. The angular velocity of rotating crank, ω, can be stated as, 2N (1) 60 The angle can be described with respect to time, t, as, t (2) 78

The displacement of piston in t seconds is, Characteristics of a Reciprocating Pump for Low-Cost Sustainable Water Hydraulic Technology Demonstrator x r r cos (3) Thus, the equation of the piston velocity can be shown as, v r sin (4) The analysis on the velocity of the piston represents how fast the water is delivered in the system. The delivery or flow rate of a triplex piston pump can be calculated by identifying the volumetric displacement of the pump. Thus, the volumetric displacement, V D, of triplex piston pump can be represented by, D LC (5) 4 V D 2 where D,L and C refers to piston diameter, stroke length and number of piston used in the pump. Thus, the theoretical flow rate of the triplex piston pump is, VD N Q (6) 60 where N is the rotational speed of the pump in RPM. In energy efficiency, the volumetric efficiency must be achieved with minimum losses as much as possible. The slippage that influences the losses must be reduced by an optimum setting of operating conditions. Any changes in slippage and pressure have little effect on the performance, provided that it is operating at higher rotational speeds and flow rates. Because the clearances are so small, leakage flow is treated as laminar as, Q P (7) Thus for a triplex piston pump, the outlet to inlet leakage or slip flow is shown as, Q L SF P 2 P 1 (8) where SF is the slip flow coefficient. During operation, a partial vacuum is created at the pump inlet as the piston moves. The fluid will flow into the cylinder and at this moment the liquid have chances to slip at the edge of piston and cylinder wall. By applying the principle of continuity to the inlet and 79

outlet pipe, the expression for actual flow rate can be state as, Q 2 Q 1 Q L (9) where Q 2 is the actual flow rate, Q 1 is the ideal flow and Q L is the slip flow rate, 2 V N SF P2 P1 Q D (10) The expression for volumetric efficiency can be stated as, VDN SF P2 P1 V (11) V N 3.0 RESULTS AND DISCUSSION D The simulation value of piston velocity with respect to rotation of the rotating crank is presented in Figure 3. The piston velocity is represented by some theoretical parameters which is, rotational speed of pump, N = 700 rpm, stroke length, L = 300 mm and radius of rotating crank, r = 150 mm. The data is also represented with three sets of degree value which is considered as the degree of rotating crank by three pistons. It is obvious that the shape of the simulated curve describes the process of the pump which is suction (negative value) and delivery (positive value). The type of pump is responsible for the curve pattern. Triplex Single Acting Pump Figure 3: Velocity Curve This shape basically depends on ratio of connecting rod length to crank radius. All the pistons movement is controlled by the crank shaft. Thus, the first piston starts to rotate a 0 degree while the second and third piston starts at 30 and 60 degree respectively. At the beginning of the stroke, the piston velocity start on 0 rad m/s and dropped to -10.86 rad m/s due to the suction process. The pistons reach the bottom dead centre at the centre of the crank rotation. On the delivery 80

Characteristics of a Reciprocating Pump for Low-Cost Sustainable Water Hydraulic Technology Demonstrator stroke, the piston moves to the right at 9.8 rad m/s. Because of the typical harmonic motion, the liquid entering and leaving each cylinder experiences a start-stop flow with velocities ranging from zero to maximum. The simulated value of volumetric efficiency, with respect to slip flow coefficient, SF, is presented in Figure 4. The efficiency is represented with various pressures, ranging from 10 bar, 20 bar, 30 bar, and 40 bar as the maximum loading pressure for the pump. The data is also represented with various rotational speeds, ranging from 0 to 4000 RPM. All figures show the trend of the volumetric efficiency, with slip factor coefficient of 0.003, 0.015, 0.03 and 0.06. Basically, the slip factor is increased from 5, 10 and 20 times of the original SF. The simulated data is recorded for a triplex piston pump having theoretical volumetric displacement of 0.038 m 3 /rev. At loading pressure, P L = 10 bar, for slip flow coefficient, SF = 0.003. It is noted that the efficiency is around 96% to 98%, from 250 RPM up to 3500 RPM. The efficiency for the pump decreases when the slip factor is increased 5 times the original value, into SF = 0.015. At the same loading pressure, the efficiency is around 80% to 98%, ranging from 250 RPM up to 3500 RPM. At SF = 0.03, or 10 times the original value, the efficiency declines from 62% to 96%, which is recorded from 250 RPM to 3500 RPM. At 20 times the original value (SF = 0.06), the volumetric efficiency is around 24% to 82%, and also can be measured from 250 RPM to 3500 RPM. The value of simulated volumetric efficiency slightly changes when the loading pressure increases to 20 bar. It is noted that for slip flow coefficient, SF=0.003, the efficiency is around 92% to 98%, from 250 RPM up to 3500 RPM. The efficiency for the pump decreases when the slip factor is increased to SF = 0.015. At the same loading pressure, the efficiency is around 62% to 96%, ranging from 500 RPM up to 3500 RPM. At SF = 0.03, the efficiency decreases from 24% to 90%, which is recorded from 1000 RPM to 3500 RPM. At SF = 0.06 (20 times the original value), the volumetric efficiency is around 0% to 82%, but now, it is only measurable from 400 RPM to 3500 RPM. Changes can be seen more clearly when the loading pressure increases to 30 bar. For slip flow coefficient, SF = 0.003 the efficiency is around 90% to 98% which is recorded from 250 RPM up to 3500 RPM. At SF = 0.015, the efficiency dropped to around 44% to 90%. The efficiency for the pump keep decreasing when the slip factor is increased to SF = 0.03 and SF = 0.06. At the same loading pressure, the efficiency is ranging from the efficiency is around 0% to 84%, and around 0% to 80%, while it can only be measured from 300 RPM up to 3500 RPM and from 400 RPM to 3500 RPM respectively. Lastly, at P L = 40 bar, It is obvious that for slip flow coefficient, SF=0.003, the efficiency is around 84% to 96%, from 250 RPM up to 3500 RPM. The efficiency for the pump decreases when the slip factor is increased to SF = 0.015. At the same loading pressure, the efficiency is dropped until 24% to 88%, ranging from 250 RPM up to 3500 RPM. At SF = 0.03, the efficiency shows significant 81

decrement from 0% to 82%, which is recorded from 350 RPM to 3500 RPM. At SF = 0.06 (20 times the original value), the volumetric efficiency is around 0% to 78%, but now, it is only measurable from 800 RPM to 3500 RPM. From this figure, it shows that at a typical rotational speed of below 800 RPM, no efficiency can be recorded with the use of pumps having slip factor of 0.06. Therefore, if the slip factor represents the use of water hydraulics in triplex piston, it would be acceptable if a higher RPM is used. And even if the highest RPM is possible, for example around 3500 RPM, it will only provide volumetric efficiency around 78%. Figure 4: Volumetric Efficiency at Loading Pressure of 10, 20, 30, 40 bar 4.0 CONCLUSION The study on reciprocating pump for water hydraulic application is being conducted at Centre of Advanced Research on Energy, Universiti Teknikal Malaysia Melaka. The objective of the study is to provide variety informationregarding to the use of low viscosity, sustainable water hydraulic in triplex piston pump. The result suggests that the use of water is efficient and 82

Characteristics of a Reciprocating Pump for Low-Cost Sustainable Water Hydraulic Technology Demonstrator practical enough, if the slip factor is maintained to 0.003, with system pressure of 10 to 40 bar. The effectiveness varies from rotational speed of 250 to 3500 RPM, and provides volumetric efficiency ranges from 6 % to 98% accordingly. The results suggest that water can be applied in using triplex piston pump to generate flow and pressure to operate a water hydraulic power system. This is true if the slip factor can be achieved with a suitable value. ACKNOWLEDGEMENT The research work is supported under the short term project (PJP/2012/FKM (15A)/S1090). The authors wish to thank Universiti Teknikal Malaysia Melaka for their financial support. BIODATA PENULIS Zarin Syukri Zaili memperoleh Ijazah Sarjana Muda dari Unviersiti Teknikal Malaysia Melaka. Kini berkhidmat sebagai pensyarah Fakulti Sains & Teknologi di Kolej Universiti Islam Melaka. Ahmad Anas Yusof memperoleh Ijazah Sarjana Muda dan Ijazah Sarjana dari Universiti Teknologi Malaysia dan memperoleh Ijazah Doktor Falsafah dari Universiti di Jepun. Kini berkhidmat sebagai pensyarah Fakulti Kejuruteraan Mekanikal, Universiti Teknikal Malaysia Melaka. Nur Fathiah Mohd Nor memperoleh Ijazah Sarjana Muda dan Ijazah Sarjana dari Universiti Teknikal Malaysia Melaka. Kini berkhidmat sebagai pensyarah Fakulti Kejuruteraan Mekanikal, Universiti Teknikal Malaysia Melaka. REFERENCES E. Trostmann, B, Frolund, B. H. Olesen and B. Hilbrecht. Tap Water as a hydraulic pressure medium. New York. Marcel Dekker, Inc. (2001). G.W. Krutz, P.S. Chua. Water hydraulics theory and applications. The Water Hydraulics, Agricultural Equipment Technology Conference, Lousville, Kentucky. United States (2004). F. Conrad, Trends in Design of Water Hydraulics Motion Control and Open- Ended Solutions, Proceedings of The 6 th JFPS International Symposium on Fluid Power, Tsukuba, Japan, pp. 420-430. (2005). 83

W. Backe, Water or Oil Hydraulic in The Future, The Sixth Scandinavian International Conference on fluid power, SICFP 99, Tampere, Finland. 51-65. (1999). A.A.Yusof, S.Mat and A.T.Din. Promoting Sustainability through Water Hydraulics Technology: The Effect of Water Hydraulics in Industrial Scissor Lift. Applied Mechanics and Materials. 315(2013) 488 492. A.A.Yusof, F.Wasbari and M.Q. Ibrahim. Research Development of Energy Efficient Water Hydraulics Manipulator for Underwater Application. Applied Mechanics and Materials. 393(2013) 723 728. R.S. Khurmi, A Textbook of Hydraulic Machines. India. S. Chand. (2001). A.A. Yusof, F. Wasbari, M.S. Zakaria and M.Q. Ibrahim. Slip Flow Coefficient Analysis in Water Hydraulics Gear Pump for Environmental Friendly Application. Proceeding of 2 nd International Conference on Mechanical Engineering Research, Malaysia, pp. 11-21 (2013). 84