Installation Instructions Central Battery Units

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

IMPORTANT SAFEGUARDS

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

Self-Testing Industrial Series

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Spectron Industrial Series

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

MIRRORLITE RECESSED EMERGENCY LIGHTING

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation And Operation Instructions

EMIU 720W Mini Inverter

Installation and Operation Instructions 10/04/13

Installation And Operation Instructions

UL AND CODE COMPLIANCE

Installation And Operation Instructions

Installation Instructions and User Manual For. 100 Watt Inverter Power System

SURE-LITES FBP140XLP Instruction Manual

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

MaxLite LED UTILITY WRAP FIXTURES

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

LMI Watt Models

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Cat# DC LED Array Emergency Driver

Installation Instructions and User Manual For

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Illuminator System Series CM

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Illuminator System Series CIII

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

Powerware Vdc Extended Battery Cabinet User s Guide.

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

LESTRONIC II BATTERY CHARGER MODEL 19740

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Installation Instruction

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

When using electrical equipment, basic safety precautions should always be followed including the following:

Owner s Manual. Powered Dandy Lifts PLM-100, PLM100W, PLM150, PLM-150W. (See separate manual for PLM-250) Model # Serial #

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

INSTALLATION & USER S GUIDE

WF-5110R True Sine Wave Inverter

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

MaxLite LED Linear HighBay Fixtures

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

Cruising Charger Series OWNER S MANUAL

SAVE THESE INSTRUCTIONS

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

FHSCP-UNV-10P-L-SD SPECIFICATIONS

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

MODEL ELC-12/40-CVM-D BATTERY CHARGER

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

MM-AVR UPS Series User s Manual

Product Installation Document

BusPro Series Instruction Manual

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

Installation Instructions and User Manual For

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Car Battery Charger Instructions for Use

MASTERsine Inverter PXA Series Installation Guide

PSJ-2212, PSJ-3612, PSJ-4424

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

600 Amp Battery Jumper with Air Compressor

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SAVE THESE INSTRUCTIONS

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

MODEL ELC-12/60-D BATTERY CHARGER

Transcription:

Phone: 605.542.4444 concealite.com! Installation Instructions s Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions When using electrical equipment, basic safety precautions should always be followed including the following: NOT SELF TESTING PER ANSI/NFPA 101 Do not use outdoors. Do not let power supply cords touch hot surfaces. Do not mount near gas or electric heaters. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately. Equipment should be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the MANUFACTURER may cause an unsafe condition. CAUTION: When this equipment is furnished with a halogen cycle lamp, these additional safeguards apply: a. To avoid shattering, do not operate lamp in excess of rated voltage, protect lamp against abrasion and scratches and against liquids when lamp is operating. Dispose of lamps with care. b. Halogen cycle lamps operate at a high temperature. Do not store or place flammable materials near lamps. The AC voltage rating of this equipment is specified on the product label. Do not connect equipment to any other voltage. Do not use this equipment for other than its intended purpose. Servicing of this equipment should be performed by qualified service personnel. Series:CB Model: CB1, CB2, CB3 Index Listed UL 924 CB 1 Depth 4.0" (10.16 cm) x Width 13.5" (34.29 cm) x Height 8.7" (22.10 cm) CB2 & CB 3 Depth 6.75" (17.15 cm) x Width 18" (45.72 cm) x Height 8.7" (22.10 cm) 1 Important Safeguards 2 Installation 3 Operation and Maintenance 4 Wiring Installation CB 1 5 Wiring Installation CB 2 & CB 3 6 Optional XC Remote Wiring Limited Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our discretion) and shall constitute fulfillment of all manufacturer's obligations. We will not allow any charge for labor, materials, etc. that does not have our written approval before the work is begun. Damage incurring in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications to the product or failure to follow installation instructions will void the warranty. Copyright Concealite Life Safety Products. All Rights Reserved. Specifications Subject to Change. 1

i Installation CENTRAL BATTERY UNIT INSTALLATION INSTRUCTIONS 1. Extend an unswitched, 24 hour AC supply of rated voltage to the area in which the unit will be installed. DO NOT energize the circuit at this time. 2. Remove front cover and any packing material inside the unit housing that may have been used for shipping purposes. 3. Remove the unit battery (if installed) and the appropriate mounting pattern knockouts in the unit housing to accommodate the electrical box screws. Also remove the round center wire pass knockout in the mounting pattern and the two keyhole mounting knockouts in the upper corners on the rear of the housing. If electrical box is not being used for utility connection, wire utility directly through knockout on the side of the unit housing using approved connector (installer supplied). 4. Secure housing to the mounting surface through the keyhole knockouts using mounting hardware (installer supplied) sized appropriately to hold the unit weight (see SPECIFICATIONS). If accessory brackets or shelves are being utilized, follow the instructions provided with those devices to assure a safe installation. Attach the unit housing to the electrical box (if used). 5. Wire unit as follows: All standard models are furnished with a dual voltage 120/277VAC field selectable input. Connect unit to utility power using approved wiring or connector (see Wiring Diagram on back of sheet). For 120V supply connect the utility hot wire to the black lead, for 277V supply, connect the utility hot wire to the orange lead. Connect neutral utility wire to the white lead. Connect green chassis ground wire provided in accordance with local codes. DO NOT energize circuit at this time. CAUTION: Insulate the unused black or orange transformer lead. Failure to insulate the unused wire will cause an unsafe condition. 6. If remote fixtures are to be connected to the equipment extend the remote circuit in accordance with Article 700 and 720 of the National Electric Code (NEC) and connect to the white and blue fused output leads from the PC board. CAUTION: the minimum wire size required by the NEC is 12 ga. copper or equivalent. Your installation my require larger size wire to ensure that the voltage drop does not exceed 5%. Do not exceed the total output rating of the equipment including any equipment mounted heads. NOTE: Larger capacity units are provided with a fused output circuit. Total load should not exceed the rated circuit load. 7. Re-install the unit battery and secure with mounting strap provided. Make battery connections to charger as follows: Standard Lead Acid Battery Connection: Connect the battery (refer to WIRING DIAGRAM. Connect the red lead from the PC board charger assembly to the positive (+) battery terminal. Connect the black lead from the PC board charger assembly to the negative ( ) battery terminal. CAUTION: Observe polarity. Failure to connect the battery properly will result in equipment failure and an unsafe condition. Optional Nickel Cadmium Battery Connection: Units provided with optional nickel cadmium batteries are supplied with polarized Molex connectors for making battery connections. Simply plug the mating Molex connectors together to make battery connection. NOTE: The emergency lamps WILL NOT illuminate at this time. 8. Energize the AC supply. The CHARGE indicator will illuminate. 9. Re-install the front cover onto the unit. 2

Operation and Maintenance OPERATION 1. To test the equipment, depress the TEST switch(es). The CHARGE indicators will extinguish and the emergency lamps will illuminate. [ NOTE: One test switch on the CB 1; Two separate test switches on the CB 2 & CB 3]. 2. Release the TEST switch(es). The emergency lamps will extinguish and the CHARGE indicator will illuminate. 3. The charger circuit will automatically activate and return the battery in a fully charged state. [ NOTE: Allow the batteries to charge for a minimum of 24 hours after installation or after a power failure before conducting a 90-minute test (see TESTING) ]. CAUTION: This equipment is furnished with a sophisticated transfer switch that will automatically disconnect the emergency lamps from the battery if the battery has been discharged to its low voltage limit or the output circuit is overloaded or experiences a short circuit. MAINTENANCE CAUTION: Always turn off AC power to the equipment before attempting any service procedure. Servicing should be performed only by a qualified technician. Use only MANUFACTURER supplied or RECOMMENDED replacement parts. 1. BATTERY: The battery supplied in this equipment requires no maintenance. However, it should be tested periodically (see TESTING) and replaced when it no longer operates the connected fixtures for the full duration of a 90 minute test. The battery supplied in this equipment will provide its full rated life expectancy when used in a temperature range of 68 to 86ºF (20 to 30ºC). 2. OTHER: Clean lenses and replace lamps, as required. TESTING 1. Allow the battery to charge for 24 hours prior to performing any test. After the charging cycle, test emergency operation by either removing utility power or pressing the unit test switch. Emergency lamps will illuminate. 2. Following the return of utility power or the release of the test switch, the emergency lamps will extinguish and the unit charger will automatically return the battery to a fully charged state. ROUTINE TEST CYCLES Paragraph 31-1.3.7 of NFPA 101-1985, Life Safety Code requires that all emergency lighting equipment be functionally tested every 30 days for a minimum of 30 seconds and tested once a year for a full 90 minute discharge cycle. Written records of monthly and annual testing are to be kept for examination by the authority having jurisdiction. Exception: 30 day testing and written test records are not required on units equipped with the self-diagnostic (SD) option. TROUBLESHOOTING 1. The emergency lamps do not operate: a. If the charge indicator light is off: Check that the AC supply circuit breaker is on. b. If the charge indicator light is on: - Check the battery for proper connection. - If remote lighting heads are connected to equipment, turn off AC supply and disconnect output circuit wires to remote fixtures. Turn on AC supply and depress the test switch. If equipment mounted lighting heads are now on, check remote output circuit for short circuit or overload condition and correct as needed. Re-install output circuit wires and restore AC power. - If problem persists, Replace battery. 2. Emergency lamps are dim: a. Incorrect voltage lamps installed in lighting heads. b. Remote circuit wire conductor size is inadequate causing excessive voltage drop. Refer to INSTALLATION (Step 6.) Limited Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our discretion) and shall constitute fulfillment of all manufacturer's obligations. We will not allow any charge for labor, materials, etc. that does not have our written approval before the work is begun. Damage incurring in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications to the product, or failure to follow installation instructions, will void the warranty. 3

Wiring Installation Instructions CENTRAL BATTERY UNIT (CB 1) WIRING INSTRUCTIONS Total Remote Fixture Load (Watts) Model # Output Volts Watts for 90 Min CB1 12VDC 100 NOTE: Connections for standard single lead-acid battery shown. Refer to SPECIFICATIONS for connection of multiple batteries. Units provided with optional nickel cadmium batteries are preconfigured and supplied with mating Molex connectors between the PC Board and Battery for making connection. RECYCLING INFORMATION All steel, aluminum and thermoplastic parts are recyclable. NOTICE: Emergency units contain rechargeable batteries which must be recycled or disposed of properly. All s Model CB 1 have this operating system. 4

Wiring Installation Instructions CENTRAL BATTERY UNIT (CB 2 & CB 3) WIRING INSTRUCTIONS Total Remote Fixture Load (Watts) Model # Output Volts Watts for 90 Min CB2 12VDC 200 CB3 12VDC 300 CAUTION: The CB 2 and CB 3 s have two sets of outputs for remote emergency 12V DC power. Max load per set of outputs is 100 watts for the CB 2 and 150 watts for the CB 3. DO NOT COMBINE LOADS TOGETHER ON JUST ONE OUTPUT. NOTE: Connections for standard single lead-acid battery shown. Refer to SPECIFICATIONS for connection of multiple batteries. Units provided with optional nickel cadmium batteries are preconfigured and supplied with mating Molex connectors between the PC Board and Battery for making connection. RECYCLING INFORMATION All steel, aluminum and thermoplastic parts are recyclable. NOTICE: Emergency units contain rechargeable batteries which must be recycled or disposed of properly. All s Models CB 2 & CB 3 have two complete sets of this operating system. 4

Wiring Installation Instructions CENTRAL BATTERY UNIT WIRING INSTRUCTIONS Total Remote Fixture Load (Watts) Model # Output Volts Watts for 90 Min CB1 12VDC 100 CB2 12VDC 200 CB3 12VDC 300 NOTE: Connections for standard single lead-acid battery shown. Refer to SPECIFICATIONS for connection of multiple batteries. Units provided with optional nickel cadmium batteries are preconfigured and supplied with mating Molex connectors between the PC Board and Battery for making connection. RECYCLING INFORMATION All steel, aluminum and thermoplastic parts are recyclable. NOTICE: Emergency units contain rechargeable batteries which must be recycled or disposed of properly. OPTIONAL: XC Remote Concealed Fixture 12V DC Output Motorized Door Power System DC RECTIFIER Black (+) Positive White (-) Negative TO REMOTE POWERED 12V DC MOTORIZED LINEAR ACTUATOR 6