SENSORES DE PAR DINÁMICO SERIE 2100

Similar documents
Series 7000 Torque Sensor for PTO-shafts

Series 7000 Torque Sensor for PTO-shafts

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

Electronic Pressure Switch EDS 3000

Version 2016 / 07 Stator All-In-One

SERIE 59S. Rear clamp. Frontal clamp INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS SIN/COS

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

Online Gearbox-Load-Monitoring to Increase Gearbox Reliability

Standard cylinders DDPC, with measured-value transducer DADE

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor

S-SERIES DISPLACEMENT TRANSDUCERS

Electronic Temperature Sensor ETS 300

ACTUATORS POSITION SENSOR

Pressure Precision. Description. Features. Measuring ranges. Applications. with front-flush diaphragm for gauge pressure and absolute pressure

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

FORCE SENSORS FORCE SENSORS

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Length [mm] Stroke Stroke LENGTH

Directional servo-valve of 4-way design

Figure 1: WPR2 Dimensions and Hardware

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

HIGH POWER SOLENOID DRIVER 1

Proportional reducing valves with integral pressure transducer

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Clavijas y tomas industriales Industrial plugs & sockets

Linear Motors & Servo Drives 3x400VAC. Linear Motor Series P The linear motor technology for industrial applications. Peak force up to 2 500N

water-cooled motor / generator with up to 13 kw continuous power

Proportional relief valves with integral pressure transducer

force/torque solutions by sensor type

! CAUTION! Damages on the machine possible.

More Precision. mainsensor Magneto-inductive displacement sensor

SPT- I / U PRESSURE TRANSMITTER for general applications

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Proportional reducing valves

Proportional relief valves

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Wind display type WSDI-2

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

PRESSURE BENCH OPERATING INSTRUCTIONS

N4 Series Magnetic Encoder Module High Resolution Module

CLA 25 AC motor ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Rear bracket SP. Stroke. Capacitor. Standard head with threaded hollow bore BA

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Accessories smart additions for efficiency and intelligent performance

GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

JUMO MIDAS Pressure transmitter

Low Profile DC Power Supply with Zero Voltage Soft Switching

Digital Pressure Regulator Sentronic PLUS Series 614

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

Proportional relief valves with integral pressure transducer

DPX moulded case circuit breakers

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

LENORD. +BAUER... automates motion. Accessories for rotary encoders GEL 20x, 21x, 23x, 26x. Technical information Version General.

STT280 SEALED TILT SENSOR

LIGHTWEIGHT AND COMPACT. SERIES SL Nm. single-position multi-position. THE ultimate COUPLING from Nm

Proportional relief valves with integral pressure transducer

Pressure sensor for liquid and gaseous media QBE620-P...

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

LTX RF LEVEL SENSOR. Instruction Manual

DRAWWIRE SENSOR. SX135 Long Range. Content: Introduction Applications. Key-Features:

1291BL Series Technical Specification Single Axis Position and Rate Table System

Data Sheet. HEDR-54xx Series Mid-Sized Housed Encoder. Description. Features. applications. Available Styles

MF /MS Series

LINEAR ACTUATORS INDEX

Pressure transmitter for elevated media temperatures

Tina 4A Connection block

K3D300 ±200kN. Description

Electronic Ballast EVG 2000-T

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Instruction Manual. Rotating Torque Sensor Type 4501A. Version Q/QA (with standard square connections) Version R (with shaft ends)

4-way directional servo-valve

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Pressure transducer DMU 01K Compact version

WATERFLUX 3070 Quick Start

Acceleration sensors (ICP technology) VBS 50 overview Configurations

HDS 5105 Amplified pressure sensor/switch

Steering column and sensor

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

INSTRUMENTATION & CONTROL

MGX. 2-jaw parallel self-centering pneumatic gripper series MGX. Parallel grippers. Pinze parallele MGX

HDS 5812 Amplified pressure sensor

Transcription:

SENSORES DE PAR DINÁMICO SERIE 2100 Rango de medida desde 2,5 hasta 500 Nm bidireccional Repetitividad <±0.1% Señal analógica 0,5 a 4,5 Vcc ó +- 2Vcc Libre de mantenimiento Medida del par hasta 5000 rpm Sistema de medida sin contacto Frecuencia muestreo 1Khz Acondicionador de la señal incluido en el sensor 1. Introduction Los sensores de par dinámico de la serie 2100, han sido diseñados para medir par bidireccional tanto estático como dinámico en tiempo real. El sistema de medida es sin contacto entre el eje y el cuerpo del sensor, consiguiendo un equipo sin mantenimiento y de una alta fiabilidad, en el interior de la carcasa se encuentra la electrónica de detección y el amplificador. El conjunto se caracteriza por un bajo consumo, precisión, larga estabilidad de la medida en el tiempo y una excelente relación calidad - precio. 2. Characteristics Model No. 2x00, (TM-HR-X V06) Max rated Torque [Nm (ft-lb)] Max Overload [Nm (ft-lb)] Max Rotational [rpm] Round (Rd) Drive Square (Sq) Drive bidirectional (+/-) bidirectional (+/-) Rd/Sq 2200-2.5 2100-2.5 2.5 5 (TM-HR-Rd-2.5 V06) (TM-HR-Sq-2.5 V06) (1.8) (3.6) 2200-5.0 2100-5.0 5.0 10 (TM-HR-Rd-5.0 V06) (TM-HR-Sq-5.0 V06) (3.7) (7.4) 2200-7.5 2100-7.5 7.5 15 (TM-HR-Rd-7.5 V06) (TM-HR-Sq-7.5 V06) (5.5) (11) 2200-17.5 2100-17.5 17,5 35 (TM-HR-Rd-17.5 V06) (TM-HR-Sq-17.5 V06) (12.9) (25.8) 2200-75 2100-75 75 150 (TM-HR-Rd-75 V06) (TM-HR-Sq-75 V06) (55.3) (110.6) 2200-175 2100-175 175 350 (TM-HR-Rd-175 V06) (TM-HR-Sq-175 V06) (129) (258) 2200-250 2100-250 250 350 (TM-HR-Rd-250.0 V06) (TM-HR-Sq-250 V06) (184.3) (258) 2100-500 500 750 (TM-HR-Sq-500 V07) (368.6) (552.9) 1000 pag. 1/6

3. Technical Features Description Symbol 2x00-2.5 (TM-HR) 2x00-5.0 (TM-HR) 2x00-7.5 (TM-HR) 2x00-17.5 (TM-HR) 2x00-75 (TM-HR) 2x00-175 (TM-HR) 2x00-250 (TM-HR) 2x00-500 (TM-HR) Unit Remarks Maximum rated torque - bi-directional M 2.5 5.0 7.5 17.5 75 175 250 500 Nm Full Scale (FS) = 0 to maximum rated torque Analog signal output V out 0.5-4.5 VDC Degree of protection IP 50 Per EN60529 Supply voltage V cc 9.0..12.0 VDC Current consumption I in < 10 (Startpeak: 60mA for 10ms) ma Signal output at 0 Nm (adj. via offset Pot.) V out (0) 2.5 V Adjustable via potentiometer Signal output resistance Signal bandwidth BW 50 1000 Hz Rotational speed (Rd or 2200: round shaft 0... 5000 n Sq or 2100: square shaft) 0... 1000 rpm Repeatability <±0.1 %FS DKD-R 3-5 Hysteresis and linearity failure and signal variation during rotation <1 <2 %FS Operating temperature range T op 0...+70 C Reference temperature: 21 C Maximum longitudinal force between shaft and housing F l 40 N Influence on meas. signal <1%FS Maximal lateral force F q 50 N Influence on meas. signal <1%FS Zero drift (temperature-related) <±0.1 %FS/ K Resistance to magnetic fields (distance 70mm) 4000 Oe 318 ka/m Minimal distance from sensor housing: 70mm Electromagnetic compatibility EN 55011, EN 6100-4-3,EN 6100-4-6, EN 6100-4-4, EN 6100-4-2, EN 50204, EN 50081-3, EN 50082-2. Not intended for medical use Storage temperature T -20...+100 C Round 383 386 392 400 685 856 861 XX Weight g Square 395 397 401 386 652 754 749 1385 4. Typical Sensor Output Sensor Label Example 5.0V Typical Output: Signal Output vs. Torque V out (max) Output M T(min) V =2500mV out (0Nm) 8 M T 8 V out M T(max) V out (min) 0.0V -TR 0 Torque (Nm) TR: Torque range Note: Graph displays measurement with V ref as reference (not 0V)! Calibration based on 0Nm to +FS See "Calibration" on the sensor label +TR Slope (S) V M out T V = out (max) 2500 M T (max) mv V out(max) and V out(min) are defined by the slope of each sensor. This means, the output is capable to be between 0.5V and 4.5V; the actual signal output range depends on the calibration value and the torque range. pag. 2/6

5. Mechanical features Potentiometer for offset adjustment A C S 2200 (TM-HR-Rd) Round drive D L (1) (2) P Socket outlet: Binder Series 712 Round end with keyway DIN 748 and DIN 6885 see table Female end DIN3121 B C Male End DIN3121 2100 (TM-HR-Sq) Square drive E K N F G M A H Flats to secure the sensor housing against rotation (1) Do not loosen or thighten the assembly screws (2) See 8.4 Offset adjustment Dimensions Nominal Torque Capacity [Nm] A B C D E F G H K L M N P S Square drive shaft (2100) 1/4 Inch 2.5-5.0-7.5-17.5 95.5 70 9.5-40 16 8 5 12-43.9 15 37 1.5 3/8 Inch 75 107 70 13-50 24 8 5 18-43.9 18 47 1.5 1/2 Inch 175 250 123.5 70 18.5-50 35 8 5 24-43.9 18 47 1.5 3/4 Inch 500 146 87 29.6-60 29.6 10.5 2 33.5-61.4 19 57 1.5 Round drive shaft (2200) Ø9 mm 2.5-5.0-7.5-17.5 125 70 27.5 9 40-8 5-23 43.9 15 37 1.5 Ø14mm 75 139 70 34.5 14 50-8 5-30 43.9 18 47 1.5 Ø19mm 175 250 179 70 54.5 19 50-8 5-50 43.9 18 47 1.5 Dimensions Keyway [mm] Keystones Round drive shaft Width Depth Length Height Length Ø9 mm 3 1.8 18.5 3 18 Ø14mm 5 3 25.5 5 25 Ø19mm 6 3.5 45.5 6 45 Keyway Keystone pag. 3/6

6. Terminal Diagram Terminal diagram of socket outlet View looking at sensor socket Reference voltage V ref Not used 4 5 3 1 Supply voltage V cc 2 Ground GND Signal output V out Pin Colour Description 1 White Supply Voltage Vcc 2 Brown Signal Output Vout 3 Black Ground 4 Blue (Not used) 5 Grey Reference Voltage 2.5V The output V ref is a constant 2.5V output and represents the virtual zero point for direct +/- torque measurement (See below Sensor cable connection section B). Use connector with proper shielding termination (360 deg). Otherwise maintain shield as close to cable ends as possible and connect to earth ground. A) This circuit is recommended for absolute torque measurement e.g. 2.5V equals toapprox. 0 Nm. Grey and blue wires are not in use. Sensor cable connection white black brown + Power Supply - (+9.. 12V) 0.5V 4.5V - signal output B) This circuit is recommended for relative torque measurement e. g. 0 V equals to approx. 0 Nm. Blue wire is not in use. white black grey brown + Power Supply - (+9.. 12V) -2.0V +2.0V ref. voltage signal output 7. Accessories Connection cable, 5-pole 1,5m and 3m (1 1,5m cable included in set) Sensor- Holder Series 9100 Readout for automatical read out with digital display of measurements. Interface options for a PC or notebook, RS232 and more features available. Series 9400 Readout for automatical read out of measurements with a PC or notebook including TorqueMeter Windows software. Keystones (for round shafts 1 pair included in set) Series 9100 Readout Series 9400 Readout pag. 4/6

8. Operating instructions 8.1 Field of Application The torque sensor is intended for use in an industrial environment (e. g. in test stands). 8.2 Scope of Delivery The torque sensor set consists of the sensor unit (signal detector head and signal conditioning electronics integrated into sensor housing), one connecting cable (length: 1.5 m) with a soldered-on plug connector, and one installation and instruction manual. 8.3 Sensor Installation and Removal The shafts connected to the torque sensor must be properly aligned. A shaft coupling should be selected to eliminate or minimize backlash, angular misalignment of the shafts, end-float, or other mechanical situations that would affect the performance or operation of the torque sensor. Secure the sensor utilizing the 8mm guides on the sensor body (optional sensor holder). A maximum cable length of 3m must not be exceeded. Using a cable or connector other than supplied, or a similar cable that is of a different length may affect the overall performance of the sensor. Prior to removing the sensor from operation, remove all lateral forces or torque stored in the mechanical assembly. Remove the keys from the shafts before loosening the mounting screws. DO NOT REMOVE THE SHAFT WITH TORQUE APPLIED TO THE SENSOR. 8.4 Offset Adjustment The sensor is preset at the factory setting to have an output signal at 0 Nm of 2.5 V. If required, the output signal can be adjusted via a potentiometer (2) (see 5. - Mechanical Dimensions). Remove the headless screw, set the potentiometer to 2.5 V using a plastic screwdriver. Replace the headless screw until flush with the surface of the housing. Factory setting is 2.5V. 8.5 Interface description Mechanical interface: For transmission on both ends of the shafts are keyway adapter or square ends (male/female) available. Electrical interface: On the sensor outside is a 5 pole plug for power supply and signal lines (see 6. Terminal diagram). 8.6 Operation (Normal, Optimisation ) For optimal measurement results, do not exceed the rated torque when using the sensor. Do not operate the sensor at the maximum rotational speed for extended periods of time. Observe the prescribed operating conditions to ensure trouble-free and maintenance-free operation of the sensor. 8.7 Operation Outside Specified Conditions, Corrective Action External magnetic fields may have an adverse effect on the measurement results. Excessive mechanical stress on the sensor (e. g. longitudinal forces / loads outside the specified limits, strong vibrations) may cause damage to the sensor and thus lead to incorrect signal outputs. Should these conditions be experienced readjusting the sensor may improve the performance (see 8.4 - Offset Adjustment). If the problem persists, do not open the sensor housing. Contact the manufacturer for assistance. 8.8 Commissioning After sensor installation, observe the following procedure: Switch on the power supply unit and check the supply voltage. Peak voltages to the sensor must be avoided! Be sure to verify the power supply voltage prior to connecting the sensor! Using the supplied sensor cable, connect the sensor to the power supply unit. Connect the sensor output to a high-resistance device such as an A/D converter, oscilloscope, PLC analogue board, PC measurement board, etc. With the sensor under no mechanical load (zero torque condition) determine the output signal voltage. If required: Adjust the signal output to read 2.5V (0 Nm); see 8.4 - Offset Adjustment. 8.9 Service and Maintenance Service Hotline: Phone: 0034 17642100 Fax: 0034 1 7642132 There are no required maintenance operations for the sensor. 8.10 Disposal Please return the device to the manufacturer for disposal. 8.11 Handling and Transportation During sensor handling, storage and transportation, it is important to ensure that the sensor is not exposed to any magnetic or electromagnetic fields higher than specified by the electromagnetic compatibility. Static or dynamic loads on the sensor must be avoided. 8.12 Safety Precautions 1. Do not open the sensor housing under any circumstances. 2. Do not remove or loosen the locating rings on the shaft ends. 3. Do not loosen or tighten the nut of the flange-mounting socket-connector (1) (see 5. Mechanical dimensions). Carrying out any of the above operations (1.-3.) results in loss of sensor calibration. The sensor does no longer operate regularly and must be returned to FAST for calibration and certification. 4. Use only power supplies that are properly isolated from the electrical mains. 5. Observe the specifications regarding maximum electrical and mechanical loads on the sensor, as shown on the sensor label and under 3 - Technical Features. 6. Protect the sensor from exposure to any electric or magnetic fields higher than specified by the electromagnetic compatibility. pag. 5/6

The three main modules of an NC sensor NC sensing system consists of three main building blocks (or modules): the Primary Sensor, the Secondary Sensor, and the SCSP (Signal Conditioning & Signal Processing) electronics. The Primary Sensor is a magnetically encoded region at the power transmitting shaft. The encoding process is performed one time only (before the final assembly of the power transmitting shaft) and is permanent. The power transmitting shaft is also called Sensor Host (or SH) and has to be manufactured from ferro magnetic material. In general, industrial steels that include around >1.5% to <8% Ni will be a good basis for the NC sensor system. The Primary Sensor converts the changes of the physical stresses applied to the SH into changes of the magnetic signature that can be detected at the surface of the magnetically encoded region. The SH can be solid or hollow. SCSP Electronics Secondary Sensor Primary Sensor The Secondary Sensor is a number of Magnetic Field Sensor (MFS) devices that are placed nearest to the magnetically encoded region of the SH. However, the MFS devices do not need to touch the SH so that the SH can rotate freely in any direction. The Secondary Sensor converts changes of the magnetic field (caused by the Primary Sensor) into electrical information. NC is using passive MFS devices (coils) as they can be used in harsh environment (for example in oil) and operates in a very wide temperature range. The SCSP (Signal Conditioning & Signal Processing) electronics drives the MFS coils and provides the user with a standard format signal output. The SCSP electronics will be connected through a twisted pair cable (2 wires only) to the MFS coils and can be placed up to 2 meters away from the MFS coils. The SCSP electronics from NC is custom designed and has a typical current consumption of 6 ma. pag. 6/6