Pantera Cartridge Filter II PCF-II

Similar documents
OWNER`S MANUAL. Quiptron Skimmers. Models

OWNER S MANUAL. Pantera Series II. High Rate Sand Filter

OWNER`S MANUAL BLAZEMASTER. B & BM Series. Engine Drive Pumps for Fire Fighting & Water Transfer

OWNER S MANUAL SINGLE STAGE STAINLESS STEEL CENTRIFUGAL PUMPS SSS SERIES. Installation / Operation / Troubleshooting SSS702 SSS2102 SSS2103 SSS3703

OWNER`S MANUAL SMH RANGE HORIZONTAL MULTISTAGE CENTRIFUGAL PUMPS SMH35 SMH45 SMH55 SMH75 SMH90

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

Davey Repair or Replacement Guarantee

FARMMASTER. JJ & OJ Series

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

TRIMLINE CARTRIDGE FILTERS

SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

OWNER S MANUAL LCT65VR ENGINE DRIVE TRANSFER PUMP. For the installation, operation and service of

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

TRIMLINE CARTRIDGE FILTERS

OWNER S MANUAL. Horizontal Multistage Centrifugal Pumps. SMH Range

OWNER S MANUAL. Dominator Submersible Pump. For the Installation, Operation and Service of

INSTALLATION AND OPERATING INSTRUCTIONS

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

EcoPure. monarchseries.com.au. Cartridge Filter. INSTALLATION & OPERATING INSTRUCTIONS 50sqft 75sqft 100sqft 150sqft

Owners Manual: - Pumps

OWNER S MANUAL. Jet Assisted Pumps Series

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron CL Series Viron Cartridge Filter Cartridge Filter

INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operating Instructions

OWNERS MANUAL. enviromax. Variable Speed Pool Pump. For the Installation, Operation and Service of the

INSTALLATION AND OPERATING INSTRUCTIONS. EXP Hurlcon Pumps CTX Series & BX Series. Bolero ND Cleaner

Manual for 12 Sand Filter/ Pump Combo Unit.

Sand Filtration System

FULFLO CARTRIDGE FILTERS

PZ200 SWIMMING POOL PUMP INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS. Viron P280. Viron Cartridge Filter.

GARDEN HOSE UTILITY PUMP

Installation and Operation Manual. Jandy Single Element Cartridge Pool and Spa Filters. CS Series Filters

SELF PRIMING CHEMICAL SERVICE PUMPS

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

OWNER S MANUAL FOR THE PROTECTEAT TEAT SPRAY SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

D L Y AU S T L IAN D ESI SPRINTA PLUS OWNER S MANUAL. SOC33548 Sprinta instructions_art3.indd 1

QL 420 / 540 CARTRIDGE FILTER

HIGH RATE SAND FILTERS

SUPER PUMP OUT SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS

M-3025CB-AV Fuel Pump

INSTALLATION AND OPERATING INSTRUCTIONS

Above Ground Cartridge Filters Models PRC50, 5PRC50, PRC75 and 5PRC75

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

Clean & Clear Filter System Owner's Manual. Important Notice WARNING

Brushcutters. Bent Shaft Brushcutter. Straight Shaft Brushcutter BCS260 BCB260

PRESSURE BOOSTER 150

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

Pressurized Bead Filters

Instruction Manual & Warranty Card

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Marlow Series Cast Iron Swimming Pool Pumps

LAWN SPRINKLER, IRRIGATION PUMP

Installation and Operation Manual. Jandy Cartridge Pool/Spa Filters. Models CJ200 and CJ250

ArtesianPro Owners Manual

Owner s Manual. H03548 Rev A

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Reverse Polarity MANUAL. Surechlor S3500

Jandy Pro Series NeverLube and Backwash Valve

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Artesian2 Owners Manual

INSTRUCTION MANUAL (original instructions) K2, K3

F 167/94 07/ GM-

Posi Clear TM Cartridge Filters Models PXC75, PXC95, PXC125 and PXC150

VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Jacuzzi. J-SF24 Media Filter Installation and Operating Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

Model &

1600 PSI ELECTRIC PRESSURE WASHER

COMMERCIAL MULTIPORT VALVES

INSTALLATION AND OPERATING INSTRUCTIONS

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Zodiac VS FloPro Variable-Speed Pump Series E3 INSTALLATION AND OPERATION MANUAL WARNING ENGLISH

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

ENGINE DRIVEN 3 FULL TRASH PUMP

Artesian Owners Manual

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Care and use guide. Contents. page

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

POND PUMP Model Nos:SPP3 & SPP6 0200

Agxcel GX12i Chemical Injection System

Artesian2 Owners Manual

SUNC3000 / Item #40885

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

HALLMARK INDUSTRIES INC

PRODUCT MANUAL. Heavy Duty Backpack Sprayer 16L

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

Submersible Pump Instructions. Safety Instructions

Petrol Engine Powered Pump Instruction Manual

Transcription:

OWNER S MANUAL Pantera Cartridge Filter II PCF-II Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.

Relax - you ve bought an... Congratulations on your decision to purchase an Onga product. Onga is one of the best know brands in its field, with a proud local and international reputation. Onga is a brand for reliability, value for money and technological innovation. You will find Onga product wherever people need to move water in 3 broad markets covering: Technologically advanced solutions for moving and treating water in the home, garden and pool. Innovative stock and crop water management solutions for primary industries. Water movement products for building services, emergency services and original equipment manufacturers. 1

1. Continual Product Improvement We employ the best engineers both in Australia and around the world to develop new and better ways to take water further. 2. Operational Excellence There is only one standard that we set ourselves for both product quality and the quality of our service. That standard is excellence... to have no-one better than us at what we do... nothing short of that is acceptable. Our commitment to quality is reinforced with our ISO 9001 accreditation. 3. A Fair Price Onga products are neither the cheapest nor the most expensive in their field. Our products do, on the other hand, always represent very good value for money; they always have and they always will. 4. Our Team of Dealers The hand picked authorised Onga dealer network throughout Australia and worldwide are second to none. We invest considerable time and resources training and supporting them through the Onga Training Academy. 2

Table of Contents Page Model Data 4 Filter Application 5 Installation 6 Installation & Assembly of Filter 7 Startup 8 Operation 9 Cartridge Maintenance 10 Tank Assembly 11 Troubleshooting 12 3

Model Data The operator must be provided with the owner s manual. This must be read before operation and followed during operation. These instructions are a guide only. Users not familiar with pool equipment should seek advice for suitably qualified persons with experience in pool equipment installation. Manufactured in New Zealand, the Onga Pantera Cartridge filter is made from UV stabilised ABS. The reputation of durability and performance makes the Pantera cartridge filter a great choice for pools of all sizes. Model PCFII-075 PCFII-100 PCFII-150 PCFII-200 Filter Area (sq.ft/sq.m) 75/7.0 100/9.3 150/13.9 200/18.6 Design Flow Rate (lpm) 300 370 410 600 Max Working Pressure (psi/kpa) 40/280 40/280 40/280 40/280 Cartridge Diameter 185mm 185mm 185mm 185mm Clearance Cartridge Height 495mm 495mm 745mm 745mm Filter Height 690mm 690mm 940mm 940mm Filter Width 285mm 285mm 285mm 285mm Replacement Element Part No. PCFII- RC075 PCFII- RC100 PCFII- RC150 PCFII- RC200 *Pool sizes given as a guide only- in general, a larger filter is better as it has a lower pressure drop, and requires less maintenance. Due to excessive cycling, This filter is not suitable for use on the pressure circuit of inbuilt in-floor cleaning systems. 4

Filter Application - General Information This filter is designed for use in domestic/residential swimming pool installations with correctly sanitised fresh or salt chlorinated water. 1. Locate the filter system as close to the pool as practical. 2. Place the filter on a level stable foundation, preferably a concrete pad or paving. 3. Position all equipment to provide ease of access for future servicing 4. Protect the filter and pump from weather and direct sunlight by ensuring that they are properly housed. 5. Ensure there is sufficient space to provide adequate ventilation to the electric pump motor 6. Clean a new pool as well as possible before filing pool and operating filter. Excess dirt and large particles of foreign matter in the system can cause serious damage to the filter and pump. 7. Ensure pump is compatible with filter specifications 5

Installation Hazardous Pressure Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Read and follow instructions in owner s manual when installing and operating equipment. Have a trained pool professional perform all pressure tests. All glued fittings and pipe work should be allowed to dry to atmosphere for 24 hours before closing installation. Failure to do so could cause injury or installation failure. The filter owner and operator must be provided with this owner s manual by the installer. This must be read before installation and followed during operation. Users not familiar with pool equipment should seek advice from suitably qualified persons. BEFORE WORKING ON THE FILTER: Hazardous Pressure! Can cause severe injury or major property damage from tank explosion. 1. Stop Pump 2. Release all pressure from system, by turning valve handle to waste. WARNING Filter pumps require hazardous voltage which can shock, burn, or cause death. BEFORE WORKING ON THE PUMP OR MOTOR: Disconnect power to motor. 6

Installation & Assembly of Filter Installation of filter should be carried out by qualified personnel. 1. Select the filters location. Ensure that the filter does not restrict the airflow from the pump s motor, and ensure that there is enough room above the filter to enable the cartridge to be removed. 2. Select whether 40mm or 50mm PVC is required. Blank off the one inlet and one outlet that will not be used with the supplied bungs/reducers. 3. Glue PVC fitings from the pump to the inlet of the filter. The adhesive needs to be either PVC type P pipe adhesive or a suitable ABS plastic adhesive like Durapipe specifically suited to ABS parts. Please ensure that all glued connections are left for 24 hours or as per instructions on glue label to ensure proper water tight bond. 4. If a chlorinator is to be used, glue a PVC line from the filter outlet to the chlorinator cell. Ensure that a gas trap is installed in accordance with the chlorinator manufacturer s instructions. Failure to install a gas trap may mean that chlorine gas accumulates inside the filter housing, with risk of explosion or asphyxiation. 5. Ensure cartridge is in place, the lid is properly seated, and the locking ring screwed hand tight only. 7

Startup 1. Ensure pool is filled to three quarters of the way up the skimmer opening. 2. Open manual air bleed on the lid of the filter, so that the filter fills with water from the pool. Air will be expelled as it fills. Close the manual air bleed when it starts to release water. 3. Open all valves and start the pump. Ensure that water is flowing from the skimmer or other pool outlet and is returning into the pool. Ensure there are no leaks in the system. 4. Record the startup pressure. This reading will be used to decide when to clean the cartridge. 5. If you notice a leak around the locking ring area after 15-30 minutes of running, stop the pump. Release system pressure using the manual air bleed, and remove the lid. Ensure all valves are closed to ensure that the pool water does not flow out through ther filter housing. Clean the seal area and the o-ring and replace. 8

Operation The filter operator or owner must be provided with this owner s manual. This must be read before operation, and followed during operation. Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Read and follow instructions in owner s manual when installing and operating equipment. Have a trained pool professional perform all pressure tests. Hazardous pressure to avoid explosion and possible severe or fatal injury, filter system pressure must not exceed 40psi (280kPa) under any circumstances. NEVER test this filter system with compressed air; never operate system with water temperature above 35 0 C. To prevent equipment damage and possible injury, turn pump OFF before adjusting or opening filter. Do not add chemicals directly into the pool skimmer. Adding undiluted chemicals may damage equipment and void warranty. 1. The filter should require no intervention during operation, except to clean or replace the cartridge. 2. When the pressure gauge shows a reading 70kPa higher than the startup reading taken in item (4) above, the cartridge requires cleaning. See below for cleaning procedure. 3. If the time period between filter cleans gets progressively shorter, it may be necessary to soak the filter in a proprietary cleaner. See your pool shop or technician for advice. This is because the build up of debris that cannot be washed away with normal methods. 4. If the filter material is torn, it will be necesary to replace the cartridge. 9

Cartridge Maintenance General: Wash outside of filter with a mild detergent and water. Rinse off with hose. DO NOT use solvents to clean filter, solvents may damage components in system. 1. On a weekly basis, check pressure during operation. When pressure is 70kPa higher than clean operating pressure, clean the filter cartridge. 2. Except during hot weather with heavy skimmer loads, operating filter 6 to 12 hours per day should be sufficient. Carefully monitor water chemical balance and follow recommendations of your local pool professional. Cartridge Cleaning 1. Switch off pump, release system pressure using the air bleed on the filter lid. Close all valves, remove locking ring from filter, remove lid. 2. Lift the cartridge out of the filter housing. 3. Inspect for damage (rips in the filter material). Replace if ripped. 4. Using a garden hose with a high pressure nozzle sweep debris from the cartridge pleats. When all pleats are clean, the cartridge is ready to be placed back in the filter. 5. Replace filter. Ensure that it is correctly seated. Replace lid, ensuring that the o-ring and sealing surface are clean, and correctly in place. Replace the locking ring. Open all valves and bleed the air from the housing. 6. Restart the pump. Water Maintenance Keep water level at least 2 (50mm) above bottom of skimmer opening. Failure to do so can allow air to enter system, causing pump to lose prime and air to enter filter. Maintain ph between 7.2 and 7.6 in pool. To prevent damage to system components, keep water temperature below 45 O C at all times. 10

Tank Assembly Item Title Quantity 1 Tank Base 1 2 Element 1 3 Lid O-Ring 1 4 Lid 1 5 Lock Ring 1 6 Air Bleed O-Ring 1 7 Air Bleed 1 8 Pressure Gauge 1 9 Mac Union Nut 1 Item Title Quantity 10 Mac Union Tail 2 11 Mac Union O-Ring 2 12 Drain Bung O-Ring 1 13 Drain Bung 1 14 Blank cap 1 15 Safety Lock Lever Screw 1 16 Safety Lock Lever Washer 1 17 Safety Lock 1 11

Trouble Shooting Symptom Cause Remedy No Water Discharge Pool water level too low Fill pool to correct level Air leaks in inlet fi ttings to pump. Check and tighten all connections. Tefl on tape fi ttings Short Filter cycles Filter Dirty Clean fi lter cartridge Replace fi lter cartridge Algae present in Pool water. DON T RUN FILTER WITH LIVE ALGAE IN POOL. Check the chemical condition of pool water and refer to Pool Water Chemical Treatment. Note: Incorrect chemical treatment will greatly shorten fi lter cycle. Filter startup pressure high and water fl ow low Filter startup pressure low and water fl ow high Filter requires cleaning Return line restricted Skimmer basket full of leaves or debris Pump strainer lid not sealed correctly Pool water level too low Pump impeller blocked Blockage in suction line Air leak in suction line Follow fi lter cleaning procedure in this manual Check for fl ow at return Clear Skimmer Basket of all foreign matter and debris Refer to pump owners manual for correct procedure for sealing strainer lid correctly Fill pool correct level Call an authorised service agent to service pump Leaking from fi lter tank joint Tank 0-ring dirty Call an authorised service agent to O-ring incorrectly fi tted service pump O-ring damaged (pinched) Should problems persist, contact your nearest Pentair Water Service Agent. 12

Notes...... 13

Notes...... 14

IMPORTANT Please attach your sales invoice/docket here as proof of purchase should warranty service be required. Please do not return Warranty Form to Pentair Water Australia - please retain for your records. Purchased From... Purchase Date... Serial No... Model No... Head Office Pentair AU/NZ: Australia 1-21 Monash Drive, Dandenong South, Vic 3175 National Customer Service: Phone: 1300 137 344 Fax: 1800 006 688 National Dealer Locator: Phone: 1800 664 266 Email: Web: au.sales@pentair.com www.pentairwater.com.au New Zealand National Customer Service: Phone: 0800 654 112 Fax: 0800 806 642 National Dealer Locator: Phone: 0800 664 269 Email: Web: nz.sales@pentair.com www.pentairwater.co.nz International Australia/New Zealand Phone: +61 3 9709 5800 Fax: +61 3 9709 5888 Information contained here-in remains the property of Pentair Water Pty Ltd. Any reproduction, display, publication, modifi cation or distribution is strictly prohibited without the prior written permission of Pentair Water Pty Ltd. Disclaimer: Every endeavour has been made to publish the correct details in this data sheet. No responsibility will be taken for errors, omissions or changes in product specifi cations. Pentair Water reserves the right to change specifi cations L300137C 0612