Digital Insulation Resistance Testers. you can depend on

Similar documents
MegOhmMeter. Users Manual

MIT515, MIT525, MIT1025, MIT1525

Digital/Analog Megohmmeter Model 1026

S1 Series. 5-kV and 10-kV Insulation Resistance Testers. S1 Series 5-kV and 10-kV Insulation Resistance Testers

HD110C Heavy-Duty Digital Multimeter

S1-568, S1-1068, S1-1568

Digital/Analog Megohmmeter Model 1026 USER MANUAL

5 kv and 10 kv Insulation Resistance

Users Manual. MegOhmMeter

MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kv DC Insulation Resistance Testers

MIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

USER MANUAL. Insulation Tester + DMM. Model MG320

BM kv Digital Insulation Tester USER MANUAL

MIT515, MIT525, MIT1025, MIT kv, 10 kv, 15 kv DC Insulation resistance testers

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Model Insulation Tester / Megohmmeter. User Manual

Digital Transformer Ratiometer

Advanced Test Equipment Rentals ATEC (2832)

User's Manual Digital High Voltage Insulation Tester Model

User Guide. Model Insulation Tester / Megohmmeter

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

KMP Insulation-Continuity Tester. Users Manual

User Guide. Model Insulation Tester / Megohmmeter

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

PAT120, PAT150 and PAT150R

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Fluke 500 Series Battery Analyzers

Multi-Function Ground Resistance Tester Model 6472

707Ex. Users Manual. ma Calibrator

Heavy-Duty Battery and Electrical System Diagnostic Tester

362 Clamp Meter. Users Manual

Ground Resistance Tester Model 3620 & 3620 Kits

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

OPERATING INSTRUCTION

New! Fluke 922 Airflow Meter. Fluke HVAC/IAQ Tools. Get more done.

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

Temperature Calibrator

DIGITAL RCD(ELCB) TESTER

323/324/325 Clamp Meter

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

DLRO10HDX 10 Amp Digital Low Resistance

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

OPERATING INSTRUCTION

COMPONENT-TESTER INSTRUCTION MANUAL

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Dawson DDM190D. Digital Multimeter User s Manual

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

MEGOHMMETER. User Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Autoranging Multimeter

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

PRODUCT GUIDE

OPERATING INSTRUCTION

T2 Tester. Calibration Information. Introduction. Safety Information

MIT300 Series Insulation and Continuity Testers

Autoranging Industrial Multimeter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

PROVA 1011 Solar System Analyzer

365 Detachable Jaw True-rms Clamp Meter

True RMS Autoranging Multimeter

1.Safe testing IMPORTANT:

Handheld Micro Ohmmeters RMO-H series

MODEL 3567A. Digital MΩ Tester. Instruction Manual

WENS30C Loop Calibrator

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

MCE TM Product Information 5 kv Electric Motor Analyzer

KTD30 Digital Insulation and Continuity Tester

3550 series BATTERY HiTESTER

Visit us at

RVS-DN Digital Reduced Voltage Motor Starter

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

PORTABLE PRODUCTS for Field Testing High Voltage High Current High Power Test Systems and Components

362 Clamp Meter. Users Manual

SafetyPAT Plus A B P/N:

Mini Multimeter with Non-Contact Voltage Detector (NCV)

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

80 Series V Digital Multimeter Safety Information

Date received into service; / /.

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

90HJRKPPHWHU 0RGHO1 (6'&RQGX WLYLW\7HVW.LW

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

DIGITAL MULTIMETER INSTRUCTION MANUAL

373 Clamp Meter. Users Manual

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Transcription:

Digital Insulation Resistance Testers you can depend on

Fluke 1550 MegOhmMeter Digital insulation testing up to 5000 Volts The Fluke 1550 is a digital insulation tester capable of testing switchgear, motors, generators and cables at up to 5000 V DC. It can be used for a wide range of tests: from simple spot checks to timed tests and breakdown tests. Measurement storage and PC interface software make it ideal for preventive maintenance. Heavy-duty leads, probes and alligator clips fit in the custom carrying case, for a rugged field testing kit. Test voltages of 500 V, 1000 V, 2500 V, 5000 V Measures up to 1 Tera-Ω Warning voltage function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD shows detailed measurement data Cable or insulation capacitance Leakage current Ramp function (0-5000 V DC) for breakdown testing Timer for dielectric absorption and polarization index tests 99 memory locations store all measurements parameters High capacity rechargeable batteries Mobile (Car) charging adapter for DC charging Includes Quicklink 1550 Software and Optical Interface cable 2 Years warranty Quicklink Software The Fluke 1550 comes with Quicklink software and has on-board memory to store individual test results. These can be down-loaded to a serial printer or computer through the integral Infrared Communication port (IRDA PORT). Fluke Quicklink 1550 Software requires a PC running Windows 95, 98, Me, 2000, NT4.0; software available in... language. Ramp Voltage at terminals Battery status Alphanumeric text Bargraph with IrDa PORT Large, digital display with analog bar graph.

Fluke 1520 MegOhmMeter Digital insulation testing up to 1000 V The Fluke 1520 MegOhmMeter is a handy insulation resistance tester for testing insulation in power system wiring and motor winding. It also measures voltage and checks continuity and ground connections with its Lo-Ohms function. Easy to use with a simple user interface, the 1520 provides insulation resistance testing up to to 4000 MΩ, with three output voltages: 250 V, 500 V and 1000 V. Large, backlit LCD with analog bargraph and digital display Three output voltages for insulation resistance testing: 250 V, 500 V, 1000 V Insulation resistance testing up to 4000 MΩ; switches automatically to voltage measurement when voltage is greater than 30 V AC or 30 V DC AC/DC voltage measurement up to 600 V Lo-Ohms function for testing connections Last reading memory display 4 C-cell batteries for up to 5,000 tests, with battery-life indicator and auto shut-off Autodischarge of capacitive voltage charges Rugged, splash-proof case with impact absorbing holster 3 Years warranty Actual output voltage Last reading memory Safety conformance All inputs are protected to IEN61010-1 CAT III 600 V and the 1520 is compliant to EN 61557/VDE 0413. Analog bargraph Live cicuit warning Large, backlit digital display with analog bar graph.

Specifications 1520 Function Range Accuracy Resolution Insulation Resistance Auto ranges 4.000 MΩ, 40.00 MΩ, 400.0 MΩ, 4000 MΩ To 100MΩ: 2% + 2 counts over 100 MΩ,: 0.001 MΩ, to 10 MΩ, 10% + 2 counts + 1%/GΩ, Test voltages 250 V, 500 V, 1000 V + 20%, - 0% Max. measurement current 1mA Audible/visible voltage warning 30 V AC or DC Lo-Ohms Resistance 0 to 40.00 Ω, 2% + 2 counts 0.01 Ω, Analog Bar Graph 0 to 100 Ω, Audible/visible voltage warning 30 V AC or DC Resistance Resistance 4000 Ω 2% + 2 counts 1 Ω, Analog Bar graph 0 to 10 kω, Voltage Voltage 0 to 600 V AC (50/60 Hz) 2% + 2 counts 1 V Mechanical Specifications Dimensions (L x W x H) Weight (with battery) 241 mm x 108 mm x 72 mm 1.1 kg Power Battery type 4 C Size 1.5 V alkaline Battery life (typical) up to 5.000 tests per EN 61557-2 Environmental Specifications Operating temperature -10 C to 50 C Storage temperature -40 C to 70 C Relative humidity (without condensation) 75% RH (40 C) Operating altitude 2500 meters Enclosure sealing IP-54 per IEC 529 Shock, vibration Per IEC 1010-1 EMI immunity EN 61326-1 Safety EN 61010-1, CAT III, 600 V, EN61557 Max.Operating Voltage 600 V AC or DC between any terminal and earth ground

Specifications 1550 Electrical Specifications All stated accuracy tolerances apply to the temperature range 0 C to 35 C. For operating temperatures between -20 C to 0 C and 35 C to 40 C, these tolerances double. Insulation Resistance Measurement Test Voltage (DC) Range Accuracy (± reading) 500 V 200 kω to 10 GΩ 5% 10 GΩ to 100 GΩ 20% 1000 V 200 kω to 20 GΩ 5% 20 GΩ to 200 GΩ 20% 2500 V 200 kω to 50 GΩ 5% 50 GΩ to 500 GΩ 20% 5000 V 200 kω to 100 GΩ 5% 100 GΩ to 1 TΩ 20% Short circuit current greater than 1 ma and less than 2 ma Bar graph range 0 to 1 TΩ Insulation test voltage accuracy 0% to +10% at 1 ma load current Induced AC mains current rejection 2 ma maximum Charging rate for capacitive load 5 seconds per µf Range Accuracy (± reading) Leakage current 1 na to 2 ma ± (5% + 2 na) Capacitance measurements 0.01 µf to 15.00 µf ± (15% rdg + 0.03 µf) Live circuit indicator 30 V to 600 V ± (5% + 2 V) AC/DC, 50/60 Hz Timer 0 to 99 minutes; settable in 1 minute increments; indicated to within 1 second Ramp 0% to 100% of selected test voltage, or until breakdown Mechanical Specifications Dimensions (L x W x H) Weight (with battery) 170 mm x 242 mm x 330 mm 4 kg Power Battery type Charger input (AC) Charger input (DC car adapter) 12 volt, lead-acid, rechargeable 85 to 250 V AC 50/60 Hz 50 VA 10 to 15 V DC, 30 VA Test voltage Number of tests Battery life (typical) 500 V 3600 Note: At higher temperatures, the battery requires more frequent charging. 1000 V 3200 2500 V 2500 5000 V 1500 Environmental Specifications Operating temperature -20 C to 40 C Storage temperature -20 C to 65 C Relative humidity 80% at 31 C decreasing linearly to 50% at 40 C Operating altitude 0 to 2000 meters Enclosure sealing IP-40 Shock, vibration MIL-PRF-28800F, CLASS II EMI immunity EN 61326 Safety EN 61010-1, CAT III, 600 V, EN61557, PARTS 1 & 2 Input Overload Protection 600 V AC continuous

Fluke 1520 and 1550 MegOhmMeters Features and specifications at a glance Function 1520 1550 Auto range Up to 4000 MΩ Up to 1 TΩ Test voltage (DC) 250 V, 500 V, 1000 V 500 V, 1000 V, 2500 V, 5000 V Max. measurement current 1 ma 1 ma < I 2 ma Audible/visible voltage warning 30 V AC or DC 30 V AC or DC Resistance lo-ohms 0 to 40.00 Ω - Resistance (max.) 4000 Ω - Voltage 0 600 V AC - Leakage current - 1nA to 2 ma +/- (5% + 2 na) Capacitance range - 0.01 µf to 15.00 µf General specifications Warranty in years 3 2 Battery life (typical) 5.000 test up to 3.600 tests (500 V tests) Safety rating CAT III 600 V CAT III 600 V Fluke 1550 Included Accessories Test leads, 5000 V-rated probes Alligator clips Interface adapter and cable Quicklink 1550 PC software DC (Car) charging adapter Line cord Soft carrying case with water-proof bottom User s manual Fluke. Keeping your world up and running. Fluke 1520 Included Accessories TL27 heavy duty test leads TP74 lantern test probes AC86 large jaw alligator clips Protective holster with hand strap Carrying case User s manual Elveveien 28, 3262 Larvik Tlf. 33 16 57 00 - Faks 33 16 57 01 post@instrutek.no - www.instrutek.no Fluke 1520 Optional Accessories SH100 shoulder strap TPAK strap and magnet Copyright 2002 Fluke Corporation. All rights reserved. Printed in the Netherlands 02/01. Data subject to alteration without notice. Pub_ID: 10479-eng Rev. 01