No.1 in testing solutions in der Prüftechnik Test Probes Test Fixtures Side approach Precise lateral contacting Catalogue 1.1
16 mm, 1 N contact force INGUN for precise lateral contacting -controlled operated Part No. 4568 2 mm, 1 N contact force Part No. 417 Side approach () are designed for the testing industry i.e. for testing electrical components where lateral contacting in the form of a horizontally guided action is necessary. The contacting can be generated in three different ways: -controlled (-H), () or pneumatically (-P). Determinant features compact and robust design stable and maintenance-free precision guide space-saving, easy and precise assembly outstanding lifespan -controlled, manual or pneumatic activation -H -controlled 14 mm, 3 N contact force, single Euro-format Operating- and function elements Stroke-controlled operated Manually operated operated housing activation lever housing bar Part No. 1236 14 mm, 3 N contact force, double Euro-format activation tappet bar check contact (Figure: () contacted state) pneumatically operated mm, 68 N contact force Part No. 12559 -P pneumatically Conformity Our pneumatically operated are regarded as unfinished machines and comply with the definition of the directive 26/42/EG. Part No. 14 2 3
-H Stroke-controlled operated with 16 mm and 1 N contact force Manually operated with 2 mm and 1 N contact force Stroke-controlled operated -H7-16-1N-2-6-S Part No.: 4568 Manually operated -2-1N-7-63 Part No.: 417 -H -controlled 4 6 series: -H max. contact force: 1 N (with centre load) max. contact : 16 mm contact generation: -controlled max. activation : 7 mm max. length (s): 6 mm torque: 1,5 Nm : approx. 2 x 6 x 4 mm (w x d x h) weight: approx.,14 kg series: max. contact force: 1 N (with centre load) max. contact : 2 mm contact generation: manual check contact : proximity switch (optionally available) max. length (s): 6 mm torque: 1,5 Nm : approx. 7 x 63 x 4 mm (w x d x h) weight: approx.,41 kg 2 The activation is carried out -controlled due to the conversion of the vertical action of the test fixture (activation ) into a horizontally guided action of the bar of the (contact ). The max. contact is designed for 16 mm with an activation of 7 mm. 4568 mounting drawing for the mounting of the Part No. 4568. 4 7 63 Activation is carried out turning the activation lever approx. 9 clockwise. The final position of the is given via an optionally available proximity switch. After activation the remains in a stable final position. 417 mounting drawing for the mounting of the Part No. 417. Additional features: operation in vacuum test fixtures possible (Figure: not contacted state) 16 16 direction direction 2 direction Set check contact Part No.: 4579 included in delivery: proximity switch SME-8-K-LED-24 (cable length approx. 2,5 m), ring magnet D6x2, countersunk screw M2,5x6 Technical information proximity switch: measuring principle: magnetic Reed switching element: closer rated operating voltage range: 12 to 3 V (DC and AC) max. output current: ma electrical connection: cable (3 wires) contacting backwards pushing (Figure: not contacted state) (Figure: not contacted state) Part No.: 4579 4 5
Manually operated with 14 mm and 3 N contact force in single Euro-format Manually operated with 14 mm and 3 N contact force in double Euro-format Manually operated -14-3N-22-145 Part No.: 1236 Manually operated -14-3N-268-145 Part No.: 12559 85 22 145 series: max. contact force: 3 N (with centre load) max. contact : 14 mm contact generation: manual check contact : micro switch (closer) max. length (s): 17 mm torque: 2,1 Nm : approx. 22 x 145 x 85 mm (w x d x h) weight: approx.,78 kg Activation is carried out turning the activation lever approx. 9 clockwise. The final position of the is given via an included micro switch (closer). After activation the remains in stable final position. 85 268 145 series: max. contact force: 3 N (with centre load) max. contact : 14 mm contact generation: manual check contact : micro switch (closer) max. length (s): 2 mm torque: 3, Nm : approx. 268 x 145 x 85 mm (w x d x h) weight: approx.,85 kg Activation is carried out turning the activation lever approx. 9 clockwise. The final position of the is given via an included micro switch (closer). After activation the remains in stable final position. 3 3 2 2 1 1236 mounting drawing for the mounting of the Part No. 1236. Additional features: quick exchangeable via two knurled-head screws mounting of one VG-strip (DIN 41612) possible 3 3 2 2 1 12559 mounting drawing for the mounting of the Part No. 12559. Additional features: quick exchangeable via two knurled-head screws mounting of two VG-strips (DIN 41612) possible 25 75 125 1 175 3 6 9 12 1 18 21 14 direction 64-pole VG-strip (female connector) Part No.: 8256 64-pole VG-strip (male connector) Part No.: 4864 96-pole VG-strip (female connector) Part No.: 8257 96-pole VG-strip (male connector) Part No.: 5195 Technical information VG-strips (DIN 41612): type: C version: straight post length: 13 mm rated current: 2 A grid: 2,54 mm loaded rows: a/c (64-pole) or a/b/c (96-pole) 14 direction 64-pole VG-strip (female connector) Part No.: 8256 64-pole VG-strip (male connector) Part No.: 4864 96-pole VG-strip (female connector) Part No.: 8257 96-pole VG-strip (male connector) Part No.: 5195 Technical information VG-strips (DIN 41612): type: C version: straight post length: 13 mm rated current: 2 A grid: 2,54 mm loaded rows: a/c (64-pole) or a/b/c (96-pole) (Figure: not contacted state) Part No.: 8256 Part No.: 4864 Part No.: 8257 Part No.: 5195 (Figure: not contacted state) Part No.: 5195 Part No.: 8257 Part No.: 4864 Part No.: 8256 Part No.: 8256 Part No.: 4864 Part No.: 8257 Part No.: 5195 6 7
-P Pneumatically operated with mm and 68 N contact force Side approach Pneumatically operated -P--68N-82-15 Part No.: 14 Lifespan To determine the lifespan of our, life cycle tests with fully automatic, computerised test standards are carried out. Thus we ensure long-term high quality and performance of our products. 28 82 14 15 series: -P max. contact force: 68 N (with centre load) max. contact : mm contact generation: pneumatic check contact : proximity switch (optionally available) max. length (s): 12 mm torque: 2, Nm operating pressure: 6 bar compressed air connection: QS-4 : approx. 82 x 15 x 28 mm (w x d x h) weight: approx.,58 kg Activation is carried out pneumatically via compressed air to the cylinder. The final position of the is given via an optionally available proximity switch. After switching off the compressed air, the sets back. We have successfully completed the latest life cycle tests under laboratory conditions on our after approx. 3. cycles without detecting wear and tear which would limit the function of the. As the lifespan depends on various incalculable factors, especially largely on individual testing use we can t provide any guarantees regarding the actual life cycle determined by the laboratory. Application examples With our we offer diversely applicable function units for the lateral contacting of electronic components which can be assembled individually matching the respective testing demand. pneumatic life cycle tester 12 8 6 14 mounting drawing for the mounting of the Part No. 14. 4 2 CE-Conformity (26/42/EG): unfinished machine -H -P 2 4 6 8 12 14 proximity switch SME-8-K-LED-24 Part No.: 25638 Set valve assembly 5/2-24 VDC Part No.: 4272 included in delivery: magnet valve, plug socket with cable, screw connection, silencer, pneumatic-hose PUN-4x,75 bl. (length approx. 1 m) Product description The structured and logical constellation of the individual numbers, the ordering index, allows clear identification and classification of our side approach. H7 16 1N 2 6 S -P pneumatically direction lever arm Technical information proximity switch: see page 5 Technical information valve assembly: valve function: 5/2 monostable operating pressure:,9 to 1 bar pneumatic connection: M5 rated operating voltage: 24 VDC signal: LED Part No.: 25638 product group drive contact force width depth version = Hx M P E H = -controlled drive x = activation [mm] M = manual drive P = pneumatic drive E = electrical drive XX XX = max. [mm] XXXN XXX = max. contact force [N] XXX XXX = width [mm] (decimal places rounded up) XXX XXX = depth [mm] (decimal places rounded up) S quick (Figure: not contacted state) Part No.: 4272 8 9
Side approach overview Product finder Product name Part No. Page Side approach Female connector 64-pole 8256 6, 7 Female connector 96-pole 8257 6, 7 Male connector 64-pole 4864 6, 7 Male connector 96-pole 5195 6, 7 Proximity switch 25638 8 -H7-16-1N-2-6-S 4568 4-14-3N-22-145 1236 6-14-3N-268-145 12559 7-2-1N-7-63 417 5 Product group Series -H Product name -H7-16-1N-2-6-S -2-1N-7-63 -14-3N-22-145 -14-3N-268-145 -P -P--68N-82-15 -P--68N-82-15 14 8 Set check contact 4579 5 Set valve assembly 4272 8 Part No. 4568 417 1236 Max. contact force (with centre load) 1 N 1 N 3 N Max. contact : 16 mm 2 mm 14 mm Contact generation -controlled manual manual Check contact --- proximity switch * micro switch (closer) Max. activation 7 mm --- --- Max. length (s) 6 mm 6 mm 17 mm Torque 1,5 Nm 1,5 Nm 2,1 Nm Operating pressure --- --- --- Compressed air connection --- --- --- Operating temp. range -5 C to +6 C -5 C to +6 C -5 C to +6 C Outside dimension (w x d x h ) approx. 2 x 6 x 4 mm approx. 7 x 63 x 4 mm approx. 22 x 145 x 85 mm 12559 14 3 N 68 N 14 mm mm manual pneumatic micro switch (closer) proximity switch * --- --- 2 mm 12 mm 3, Nm 2, Nm --- 6 bar --- QS-4-5 C to +6 C -5 C to +6 C approx. 268 x 145 x 85 mm approx. 82 x 15 x 28 mm More by INGUN Do you need test fixtures: for testing low, mixed or high volumes with different usable areas with different contact forces with special test system interface for testing higher voltage we recommend the manual test fixture series MA xx-series (low volume) MA 21xx-series (mixed volume) MA 32xx-series (high volume) Weight approx.,14 kg approx.,41 kg approx.,78 kg approx.,85 kg approx.,58 kg Recommended accessories --- (see page 5) (see page 6) CE-Conformity (26/42/EG) --- --- --- (see page 7) (see page 8) --- unfinished machine * optionally available (not included in delivery) Permitted loads You will find further information about the secure and intended use of the INGUN in the respective operating instructions. 3 3 2 2 1 (Part No. 12559) (Part No. 1236) (Part No. 14) (Part No. 4568, Part No. 417) Please contact us for further information. Prices and delivery time on request. MA 2112/D/H/S-7/Pylon Please contact us. You would like more information about our manual test fixtures and further innovative products? MA 36 Please visit our website www.ingun.com or ask for our latest catalogue: 3 6 9 12 1 18 21 Tel +49 7531 815- info@ingun.com 1 11
M-PR-6: 9/15 EN-1.1 Test Probes and Test Fixtures by Ingun Headquarters INGUN Germany Subsidiaries INGUN Benelux INGUN China INGUN India INGUN Korea INGUN Mexico INGUN España INGUN Switzerland INGUN UK INGUN USA Europe Austria Benelux Bosnia-Herzegovina Croatia Czech Republic Denmark Estonia Finland France Germany Hungary Italy Norway Poland Portugal Romania Serbia Slovenia Slovak Republic Spain Sweden Switzerland Turkey United Kingdom Asia China Hongkong India Israel Japan Korea Malaysia Taiwan Thailand Vietnam Africa South Afirca Tunesia Australia Australia New Zealand America Argentinia Brazil Canada Mexico USA The addresses of our international agencies can be found under www.ingun.com ingun Prüfmittelbau GmbH