kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

Similar documents
kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Voltage. kva kw kva kw

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

C U K U R O V A GENERATOR SYSTEMS

Perkins 404D-22G diesel engine Newage/Stamford BCI184E alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TAG2 diesel engine Newage/Stamford UCI274F alternator Standard Generator Features

GNS 670 P. Stand-by power: 670 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 1100 P. Stand-by power: 1100 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

GNS 400 V. Stand-by power: 400 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

GNS 630 V. Stand-by power: 630 kva. Diesel Generating Sets, made for Europe. Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

GNS 500 V. Stand-by power: 500 kva. Diesel Generating Sets, made for Europe

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

Volvo TAD530GE diesel engine Leroy Somer LSA 44.2 VS3 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

CUKUROVA GENERATOR SYSTEMS

Volvo TAD941GE diesel engine Leroy Somer LSA 46.2 VL12 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

204 KW / 254 KVA POWERED by

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

28 KW / 28 KVA POWERED by

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

Perkins 4016TAG1A diesel engine Stamford PI734E alternator Standard Generator Features

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

130 KW / 165 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

55 KW / 70 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

600 KW / 750 KVA POWERED by

64 KW / 80 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

30 KW / 40 KVA POWERED by

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

Perkins TWG2A diesel engine Newage/Stamford PI734B alternator Standard Generator Features

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

18 KW / 18 KVA POWERED by

Perkins TAG3A diesel engine Newage/Stamford PI734E alternator Standard Generator Features. Optional Features ISO ISO 9001:2000

2000 KW / 2500 KVA POWERED by

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

500 KW / 625 KVA POWERED by

Perkins 2206A-E13TAG2 diesel engine Newage/Stamford HCI444E alternator Standard Generator Features

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

300 KW / 375 KVA POWERED by

UCDI224F - Technical Data Sheet

1000 KW / 1250 KVA POWERED by

UCI224C - Technical Data Sheet

UCI274H - Technical Data Sheet Winding 06

640 KW / 800 KVA POWERED by

UCDI274J - Technical Data Sheet

UCDI224E - Technical Data Sheet

UCI274H - Technical Data Sheet

UCI274C - Technical Data Sheet Winding 06

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI736F - Winding 312. Technical Data Sheet

UCI224F - Technical Data Sheet

UCI274D - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274G - Technical Data Sheet

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

UCDI274K - Technical Data Sheet

HCI634G - Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

HCI 534C/544C - Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

1800 KW / 2250 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

HCI 434E/444E - Technical Data Sheet

45 KW / 55 KVA POWERED by

HCI634V - Technical Data Sheet

HCI 434D/444D - Technical Data Sheet

HCI 534F/544F - Technical Data Sheet

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Transcription:

Voltage 380-415 Prime* Standby* kva kw kva kw 1844 1475 2030 1624 Ampere 2568 Prime Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply 10% overload power for a period of 1 hour in 12 hours operation as it is defined in ISO 3046. Standby Rating Applicable for supplying continuous power ar variable load in the event of a utility power failure and overload is not allowed as it is defined in ISO 8528-3. Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 16 cylinder, water cooled engine 52 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features Automatic load transfer panel Automatic syncronization and power sharing systems Soundproof canopy Container type enclosers Road trailer Job-site trailer Protection circuit breaker Air start Remote type radiator Base fuel tank External type fuel tank Automatic fuel transfer system Residential silencer Dimensions & Weight Open Type KZS1850PS Sound Attenuated KZS1850PS Dry Weigt kg 11500 Dry Weigt kg Length Width 5300 2300 Length Width Height Tank Capacity L 2450 External Height Tank Capacity L External KZS1850PS Technical Data Sheet 120508 - Page1

Engine Technical Data Cooling System Manufacturer PERKINS Type Tropical, heavy duty type Model 4016TAG1A Ambient temperature, C 52 Type 4 cycle, water-cooled Engine coolant capacity, Liters 95 Number of cylinders 16 Engine&Radiator coolant capacity 316 Cylinder arrangement 60 Vee Jacket coolant flow Liters/sec 19 Displacement, Liters 61,123 Cooling minimum airflow m³/min 2394 Bore X Stroke, 160 X 190 Two twin thermostats Compression Ratio 13,6:1 Twin gear driven circulating pumps Combustion System Direct injection Crankshaft pulley for fan drive Aspiration Turbocharge, air to air cooled Rotation Anticlockwise viewed on flywheel Lubrication System Gross engine power, kwb 1741 Fan Power, kwm 51 Type Pressurized BMEP gross, bar 22,8 Lub oil capacity sump min, Liters 214 Combustion air flow, m³ / min 140 Lub oil pressure, MPa 0,34 Exhaust gas temp.(after turbo), C 439 Wet sump with filler and disptick Exhaust gas flow (after turbo),m³ / m343 Engine jacket water / lub oil temperature stabilizer Mean piston speed, m / s 9,5 Full-flow spin-on oil filters Fuel System Fuel Consumption Type of injection system Fuel injection pump Fuel injector pressure, bar Delivery/hour at 1500rev/min, Lt Direct injection Combined unit injector 234 1380 liters per hour %110 Load %100 Load %75 Load %50 Load Fuel lift pump type Tuthill TCH 5 Governing to Electronic governor to ISO 3046 Part 4 class A1 grams per kwh %110 Load %100 Load Unit fuel injectors with lift pump and hand stop control %75 Load Full-flow spin-on fuel oil filters %50 Load 424 L 383 L 277 L 185 L 207 g/kwh 205 g/kwh 198 g/kwh 198 g/kwh Electrical System Alternator 24 Volt with integral regulator Standby kw Prime kw Model Starter motor (DC) 24 Volt Gross Net Gross Net Starter motor power 16,4 kw Turbo inlet temperature shutdown switch Overspeed switch and magnetic pick up 24 Volt stop solenoid Combined high coolant temperature / low oil pressure switch 4016TAG1A 1741 1690 1588 1537 KZS1850PS Technical Data Sheet 120508 - Page2

Alternator Technical Data Optional Equipment Manufacturer STAMFORD Optional Permanent Magnet Generator (PMG) provides an isolated Model PI734E power supply to the excitation control system Type 4-Poles, Rotating Field, Brushless MX321 (PMG) with 3 Phase Sensing and improved Regulation 0.5% Standby power at rated voltage, kva2035 Quadrature Droop kit for Parallel Operation Efficiency, % 95,6 Winding Protection Thermistors Power factor 0.8 Temperature Indicaiton RTD's Phase 3 Air filters Frequency, Hz 50 Anti condensation heaters Speed, Rpm 1500 Voltage, V 380/415 Excitation Self excited Stator windings 2/3 Pitch factor Regulation AVR, Auto Voltage Regulator Terminals&Terminal Box Voltage Regulator MX341 Voltage Regulation, % ± 1 Standard generators feature a main stator with 6 ends brought out to R.F.I Suppression BS EN 61000-6-2,BS EN 61000-6-4 the terminals, which are mounted on the frame at the non-drive end VDE0875G, VDE 0875N of the generator. A sheet steel terminal box contains the AVR and Waveform distortion No Load <1.5% Non distorting balanced provides ample space for the customers wiring and gland Rotor Dynamic balanced arrangements.it has removable panels for easy access. Overspeed, Rpm 2250 Short circuit current < 300% Shaft&Keys TIF Less than 50 Insultion class H All generator rotors are dynamically balanced to better than BS6861 Construction Single bearing, direct coupled :Part 1 Grade 2.5 for minimum vibration in operation. Two bearing Coupling Flexible generators are balanced with a half key. Stator winding Double layer concentric Connection WYE Insulation / Impregnation Protection class IP23 Cooling air volume,m³ / sec 2,69 The insulation system is class 'H' All wound components are impregnated with materials and Winding&Electrical Performance processes designed specifically to provide the high build required for static windings and the high mechanical strength required for All generator stators are wound to 2/3 pitch.this eliminates triplen rotating components. harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch Standards design avoid sexcessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully Newage Stamford industrial generators meet the requirements of BS connected damper winding reduces oscillations during paralelling. EN 60034 and the relevent section of other international standards such as This winding, with the 2/3 pitch and carefully selected pole and BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 tooth designs, ensures very low waveform distortion. Other standards and certifications can be considered on request Quaility Assurance Standby Prime Model Generators are manufactured using production procedures having a quaility kva kw kva kw assurance level to BS EN ISO 9001. PI734E 2035 1628 1900 1520 KZS1850PS Technical Data Sheet 120508 - Page3

Deepsea 7320 Control System Description Deepsea 7320 is an Auto Mains(Utility) Failure Control module. The module is used to monitor a mains supply and automaticlly start a standby generator set. The module can also monitor an extensive number of engine parameters and it can display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC and it also provides real time diagnostic facilities Specification DC SUPPLY Continuous Voltage Rating: 8 V to 35 V Maximum Operating Current: 340 ma at 12 V, 160 ma at 24 V Maximum Standby Current: 160 ma at 12 V, 80 ma at 24 V Charge Fail/Excitation Range: 0 V to 35 V MAINS(UTILITY) & GENERATOR Voltage Range: 15 V - 333 V AC (L-N) Frequency Range: 3,5 Hz to 75 Hz OUTPUTS Output A (Fuel): Output B (Start): Output C & D : Input Functions display on LCD 15 A DC at supply voltage 15 A DC at supply voltage 8 A 250 V (Volt free) Generator Volts Volts L1-N, L2-N, L3-N Generator Volts Volts L1-L2, L2-L3, L3-L1 Generator Amps Amps L1, L2, L3 Generator Frequency Hz Mains Volts Volts L1-N, L2-N, L3-N Mains Volts Volts L1-L2, L2-L3, L3-L1 Mains Frequency Hz Engine Speed RPM Plant Battery Volts Volts Engine Hours Run Hour Generator total power kva L1, L2, L3,total Generator total power kw L1, L2, L3,total Generator power factor Cosφ L1, L2, L3,total Features 4-Line back-lit LCD text display and five key menu navigation LED and LCD alarm indication 9 configurable inputs and 8 configurable outputs Configurable timers, alarms and event log (250) Fuel usage monitor and low fuel alarms Charge alternator failure alarm Manual speed and manual fuel pump control Engine exerciser and ''Protections disabled'' feature kw overload protection Power monitoring ( kw, h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and duy load outputs) Automatic load transfer and unbalanced load protection Independent Earth Fault trip Support for up to three remote display units and USB connectivity Configurable display languages Remote SCADA monitoring User selectable RS232 and RS485 counications SMS messaging ( external modem required) Additional display screens to help with modem diagnostics Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits Optional Input Functions Engine Oil pressure Fuel level Engine Temperature kpa % C KZS1850PS Technical Data Sheet 120508 - Page4

Model Codes and General Information Kunz Diesel Generator KZ S 1850 P S Alternator Make-Stamford Engine Make-Perkins Prime Rating - kva Stationary type KUNZ diesel generator Perkins 4000 Series Diesel Engine Newage / Stamford Alternator 4016 T A G 1A P I 73 4 E Power Level Genset Engine Air to air charge cooled Turbocharged 4000 Series, 16 cylinder Core Length Number of poles Shaft Height in cm Industrial Generator type KZS1850PS Technical Data Sheet 120508 - Page5