ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

Similar documents
LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year.

Product Evaluation Report

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

Equivalency Evaluation to 2010 FBC

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

ICC-ES Evaluation Report

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

continuous mounting flange intended for direct attachment to roofing substrate.

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

Equivalency Evaluation to 2010 FBC

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

EVALUATION SUBJECT: >B< MAXIPRO PRESS FITTINGS FOR AC AND REFRIGERATION APPLICATION

EVALUATION SUBJECT: GASTITE FLASHSHIELD METALLICALLY SHIELDED CORRUGATED STAINLESS STEEL TUBING

CITY OF LOS ANGELES CALIFORNIA

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS

Not to be distributed outside of FM Approvals and its affiliates except by Customer

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

Code Compliance Research Report CCRR-0258

TM MANUFACTURERS

UNDERSTANDING FIREBLOCK

Tubular Daylighting Device with Proven Performance

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

TECHNICAL DATA SHEET Artisan Lap Siding

National Evaluation Service, Inc.

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

Submittal Requirements for Product Evaluation - Doors

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

AAMA/WDMA/CSA 101/I.S.2/A440-08

SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

EVALUATION SUBJECT: EPA WATERSENSE HUNTER INDUSTRIES WEATHER-BASED IRRIGATION CONTROLLERS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Model A-FS-CM-SP Skylight Skyco Skylights

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Skylight. VELUX America LLC

A. This Section includes the following types of sectional overhead doors:

CREEK Technical Services, LLC

FIXED SKYLIGHTS. A skylight in every shape and size. SERIES SI5006

STREAMLINED SOLAR CHECKLIST Owner Name:

Roof Hatches Smoke Vents /BAB BuyLine 0898

Artisan Siding with Lock Joint System

CREEK Technical Services, LLC

Contents. Preface 6. 1 Scope General Outside of scope Terminology Units of measurement 13 1.

Commercial skylights. Dynamic Dome skylight. whyskylights.com

ENLIGHTENED LIVING RESIDENTIAL SKYLIGHTS E-CLASS CURB-MOUNT ARCHITECTURAL SERIES

SECTION SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

TECH BULLETIN. SIP No. Subject: Fiber Cement Siding from James Hardie. Date: February 2010 (Revised November 2015)

AAMA/WDMA/CSA 101/I.S.2/A440-08

Residential skylights

Quick Selection Guide

BIRDVIEW SKYLIGHTS The Clear Choice

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015.

Engineered to fit Thermatite and Alumatite Sectional Overhead Doors

Guangzhou Stadium Project TRADITIONAL

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

Residential skylight sizes 2008 edition

EVALUATION SUBJECT: KITCHEN AND VANITY CABINETS

New Gateway 101/I.S.2/A440

PRODUCT SHEET MOULDINGS

Installation Instructions

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

SECTION FRAMELESS GLASS VERTICAL POST SHOWER DOOR SYSTEM

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

Automatic Roof Door Vents

Fire, Smoke, and Combination Fire Smoke Dampers

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Québec) J3X 1P7 Tél. : (450) Fax : (450)

EVALUATION SUBJECT: EPA WATERSENSE SHOWERHEADS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

2.0E ES LVL U.S. Design Manual

PRIMEX VENTING PRODUCTS AND ACCESSORIES

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

RECEIVING AND INSPECTION

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

METAL BUILDING AND STANDING SEAM COMPONENTS

01 CONTENTS. e-beam. e-beam. Technical Information 03

DASMA DASMA

Roof Hatches Heat and Smoke Vents Sidewalk and Floor Doors

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

City of Storm Lake Fire Department Heavy Rescue Specifications

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

Transcription:

ESR-2253 Issued December 1, 2006 This report is subject to re-examination in one year. ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900 Montclair Road, Suite A, Birmingham, Alabama 35213 # (205) 599-9800 Regional Office # 4051 West Flossmoor Road, Country Club Hills, Illinois 60478 # (708) 799-2305 DIVISION: 08 DOORS AND WINDOWS Section: 08620 Unit Skylights REPORT HOLDER: SOLATUBE INTERNATIONAL, INC. 2210 OAK RIDGEWAY VISTA, CALIFORNIA 92081-8341 (760) 597-4400 www.solatube.com info@solatube.com EVALUATION SUBJECT: SOLATUBE TUBULAR SKYLIGHTS 1.0 EVALUATION SCOPE Compliance with the following codes: # 2003 International Building Code (IBC) # 2003 International Residential Code (IRC) # 1997 Uniform Building Code (UBC) Properties evaluated: # Structural # Durability # Weather resistance 2.0 USES The Solatube Tubular Skylights described in this report are plastic-glazed tubular skylights complying with Chapters 24 and 26 of the IBC and UBC, and Section R308.6 of the IRC. 3.0 DESCRIPTION Solatube Tubular Skylights consist of a light-transmitting dome with an optional internal curved reflector; a roofmounted support base (flashing or curb); an upper-tubesupporting element (dome ring); reflective light-conducting tubing of either adjustable 0-to-30-degree elbows or 0-to-90 degree elbows, and/or straight tube extensions; a bottomtube-supporting element (either ceiling ring or round-tosquare plastic transition box); and a ceiling-mounted lightdiffusing assembly (diffuser). The Solatube skylights have a maximum allowable air leakage of 0.3 cfm/ft 2 (1.5 L/s C m 2 ). Solatube Tubular Skylights are available in 10-, 14- and 21- inch-diameter (254, 356 and 533 mm) sizes, identified as models 160 DS, 290 DS and Solamaster, respectively. See Figures 1 and 2. 3.1 Domes for the 10- and 14-inch-diameter models (160 DS and 290 DS): The 10- and 14-inch-diameter (254 or 356 mm) models are available with single acrylic and dual-glazed acrylic options. See Figure 1 and Table 1. 3.2 Domes for the 21-inch diameter model (Solamaster): The 21-inch-diameter (533 mm) model is available with single acrylic and single polycarbonate glazing options. See Figure 2 and Table 1. 3.3 Dome Rings: Dome rings are used to connect the reflective tubing to the flashing and secure the dome. A reflector may be mounted inside the dome. Domes snap onto the dome ring for the 10- inch- and 14-inch-diameter (254 and 356 mm) models. Domes are mechanically fastened to the dome ring for the 21- inch-diameter (533 mm) model. See Figures 1 and 2. 3.4 Ceiling Rings: Ceiling rings are used as mounting frames for the diffuser assemblies and to connect the light-conducting tubing to the tube-supporting ceiling for the 10- and 14-inch-diameter (254 or 356 mm) models. See Figure 1. 3.5 Round-to-square Transitions: Round-to-square transitions are used to connect cylindrical tubing to a square aperture at the ceiling for suspended and framed ceiling applications for the 21-inch-diameter (533 mm) model. See Figure 2. 3.6 Flashing: Pitched flashing is used for the 10- and 14-inch-diameter (254 or 356 mm) models. Nonpitched flashing or curb flashing is used with the 10-, 14- and 21-inch-diameter (254, 356 or 533 mm) models. Counter-flashing is used for the 10- and 14- inch-diameter (254 or 356 mm) models in tile roof applications. Turret extensions are available in lengths of 2, 4, 12, 24, 36 and 48 inches (51, 102, 305, 610, 914 and 1219 mm) for the 10- and 14-inch-diameter (254 and 356 mm) models, and 12, 24, 36 and 48 inches (305, 610, 914 and 1219 mm) for the 21-inch-diameter (533 mm) model. See Figures 1 and 2. 3.7 Diffusers: The Optiview diffuser is a Class A (Class I) polycarbonate material with a flame spread index not exceeding 25 and a smoke developed index not exceeding 450, when tested in accordance with ASTM E 84 (UBC Standard 8-1). Vusion lens and optional decorative diffuser attachments are Class C (Class III) acrylic materials with a flame spread index not exceeding 200 and a smoke developed index not exceeding 450, when tested in accordance with ASTM E 84 (UBC Standard 8-1). See Figures 1 and 2 and Table 1. 4.0 INSTALLATION 4.1 General: Installation of Solatube Tubular Skylights must comply with this report, the applicable code and the manufacturer s published installation instructions. See Figures 1 and 2 for details. are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2006 Page 1 of 5

Page 2 of 5 ESR-2253 A 10.75-, 14.75- or 22-inch-diameter (273, 375 or 559 mm) round hole, for the 10-, 14- and 21-inch-diameter (254, 356 or 533 mm) skylights, respectively, must be cut in the roof sheathing and ceiling below the attic space. The sheathing must be minimum 7 / 16 -inch-thick (11.1 mm) orientated strand board complying with DOC PS 2, or 1 / 2 -inch-thick (12.7 mm) plywood complying with DOC PS 1 or DOC PS 2. The skylight support base must be attached to the roof sheathing using eight No. 10 by 2-inch-long (51 mm) stainless steel or dacrotized-finish (corrosion-resistant) steel sheet metal screws for the 10- and 14-inch-diameter (254 and 356 mm) models, and sixteen screws for the 21-inch-diameter (533 mm) model. A felt or foam weather seal must be adhered to the top edge of the skylight support base for the 21-inchdiameter (533 mm) model. A polyurethane-based sealant must be used to seal the flashing or curb to the roof. The reflective top tube with attached dome ring must be inserted into the skylight support base opening. A curved reflector may be mounted inside the dome. The dome ring must be secured to the support base using four No. 8 by 1- inch-long (25.4 mm) stainless steel, dacrotized-finish (corrosion-resistant) or other corrosion-resistant steel pan or truss head sheet metal screws for the 10- and 14-inchdiameter (254 and 356 mm) units, and six No. 8 by 3 / 4 -inchlong (19.1 mm) screws for the 21-inch-diameter (533 mm) unit. The 10- and 14-inch-diameter (254 and 356 mm) units terminate at the ceiling into the ceiling ring installed using six No. 6 by 1 5 / 8 -inch-long (41 mm), corrosion-resistant, bugle head, drywall screws and/or four plastic self-locking anchors with No. 8 by 1 1 / 2 -inch-long (38 mm), corrosion-resistant sheet metal screws or four plastic anchors/screws only. The 21-inch (533 mm) unit terminates at the ceiling into a round-to-square plastic transition box set into the framework on a suspended T-bar ceiling system, or must be installed into a gypsum ceiling using four No. 6 by 1 5 / 8 -inch-long (41 mm), corrosionresistant, bugle head drywall screws. The 10- and 14-inchdiameter (254 and 356 mm) light diffusers must be secured onto the ceiling ring by means of the Snap fit feature. The 21- inch-diameter (533 mm) light diffuser must be secured onto the square-to-round plastic transition box by means of four diffuser latches or, for the 21-inch-diameter (533 mm) open ceiling light diffuser, by means of four plastic diffuser clips. The lowest edge of the support base turret opening must be at least 4 inches (102 mm) above the plane of the roof. This may be accomplished with installation of the optional Solatube 2- or 4-inch-high (51 or 102 mm) galvanized or aluminized-steel turret extension. The 4-inch (102 mm) clearance requirement and the turret extension are not required on roofs of IBC Group R-3 or UBC Group R, Division 3, occupancy with a minimum slope of 3:12 (25%). 4.2 Tile Roofs: For installation on a tile roof, a dead-soft 0.020-inch-thick (0.51 mm) pleated aluminum sheet must be used as malleable counter-flashing. After the appropriately sized hole for the 10- or 14-inch-diameter (254 and 356 mm) Solatube skylight is cut in the roof sheathing, a metal base flashing must be placed over the hole and secured in place using eight No. 10 by 2-inch-long (51 mm) stainless steel or dacrotized-finish steel panhead sheet metal screws. See Figure 1 for additional details. Tiles surrounding the flashing are cut according to the profile of the flashing, with a maximum clearance of 1 / 2 inch (12.7 mm) from the flashing. The pleated aluminum sheet, with a circular hole cut in the center to match the flashing, must be placed over the flashing. A galvanized or aluminized steel turret extension ring must be placed over the opening of the base flashing, sandwiching the aluminum sheet between the flashing and turret extension ring. The aluminum sheet must then be secured to the top of the tiles in the course below using nonalkaline and nonacidic tile mastic. The remaining sheet must be tucked under the tiles in the upper course. When installing the system with high-profile tiles, the upper and side edges of the pleated aluminum must be bent up to form a bird stop and water seal under the upper course tiles and surrounding field tiles. 4.3 Allowable Loads: The allowable positive and negative loads are 60 psf (2.87 kpa), for the 10- and 14-inch-diameter (254 and 356 mm) skylights, and 35 psf (1.67 kpa) for the 21-inch-diameter (533 mm) skylight. 5.0 CONDITIONS OF USE The Solatube Tubular Skylights described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the manufacturer s published installation instructions and IBC Section 2405, IRC Section R308.6 and UBC Sections 2409 and 2603.7, as applicable. In the event of a conflict between the manufacturer s published installation instructions and this report, this report governs. 5.2 The maximum positive and negative allowable loads are as described in Section 4.2 of this report. 5.3 Skylights are limited to use on wood-framed roof construction. 5.4 Where a Class A, B or C roof covering is required, skylight dome edges for the 10- and 14-inch-diameter (254 and 356 mm) skylights must be protected with the application of galvanized or aluminized steel dome-edge protective rings, as shown in Figure 1. Dome-edge protective rings are not required for the 21-inchdiameter (533 mm) skylights with 8- or 11-inch-high (203 or 279 mm) flashing, or any model with curb-mount flashing on curbs a minimum of 8 inches (203 mm) high. 5.5 Solatube Tubular Skylights are produced in Vista, California, under a quality control program with inspections by Underwriters Laboratories Inc. (AA-668). 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Plastic Skylights (AC16), dated June 2006. 7.0 IDENTIFICATION The Solatube Tubular Skylights described in this report must have a permanent label bearing the manufacturer s name (Solatube) and address; the product name; the name of the inspection agency (Underwriters Laboratories Inc.); the evaluation report number (ESR-2253); the plastic classification (CC-1 or CC-2); the thickness of the plastic glazing prior to forming. The 21-inch-diameter (533 mm) skylight must also have a safety label complying with Class 1, ANSI Standard Z35.1, warning of the risk of fall.

Page 3 of 5 ESR-2253 TABLE 1 SOLATUBE SKYLIGHT MATERIAL COMPONENTS COMPONENTS 1 MATERIAL THICKNESS SKYLIGHT MODEL (inch) 10-inch 14-inch 21-inch Outer dome 2 Acrylic 1 0.125 X X Inner dome 2 Acrylic 1 0.115 X X Dome 2 Acrylic 1 0.143 X Dome 3 Polycarbonate 1 0.125 4 X Support base Galvanized or aluminized steel 0.030 X X X Turret extensions Galvanized or aluminized steel 0.030 X X X Round-to-square transition PVC 0.060 X Round-to-square transition Acrylic 0.100 X Dome edge protective ring Galvanized or aluminized steel 0.030 X X X Tile roof kit Dead soft, pleated aluminum 0.020 X X Reflective tube Aluminum 0.015 X X Reflective tube Aluminum 0.018 X Acrylic Light diffuser 2 Acrylic 0.100 X X X Optiview diffuser 2 Polycarbonate 0.022 X X X For SI: 1 inch = 25.4 mm. 1 Plastic dome materials conform to products specified in the approved quality control manual.. 2 Classification CC-2. 3 Classification CC-1. 4 Thickness prior to thermoforming.

Page 4 of 5 ESR-2253 FIGURE 1 10-INCH AND 14-INCH SOLATUBE DETAILS

Page 5 of 5 ESR-2253 FIGURE 2 21-INCH SOLATUBE WITH DETAILS