USER GUIDE Moisture Meter

Similar documents
USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Non-Contact Phase Rotation Tester

Hot Wire CFM/CMM Thermo-Anemometer

User Guide. Model Insulation Tester / Megohmmeter

Non-Contact Phase Rotation Tester

Digital Formaldehyde Meter

USER MANUAL. Insulation Tester + DMM. Model MG320

Model Insulation Tester / Megohmmeter. User Manual

Solar Power Light Meter

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

Phase Sequence Tester

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

Model Battery Powered Milliohm Meter

User's Manual. Earth Ground Resistance Tester. Model Introduction

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User Guide. Model Insulation Tester / Megohmmeter

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

Mini Multimeter with Non-Contact Voltage Detector (NCV)

True RMS Autoranging Multimeter

Autoranging Multimeter

Autoranging Industrial Multimeter

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

User's Manual Digital High Voltage Insulation Tester Model

User's Guide. CO 2 Meter. Model CO250

NearBright Illuminated Near Vision Kit. User s Guide

Compact Scales. Software Revision V1.25 & above

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

User's Guide. True RMS Multim eter. Extech 430

TMD90A Dual Input Digital Thermometer

Spotlight 1,000,000 Power Series Cordless Rechargeable

37SCENE 46SCENE 79SCENE

INSTRUCTION MANUAL DM5B Fax: (503)

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

Panel Mount Digital Tachometer Model

HG 20F-012E-01 OIL CONTROL GUN

Digital/Analog Megohmmeter Model 1026 USER MANUAL

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

OPERATING MANUAL CMP-200

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Installation instructions

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Flashlights Unlimited Xenopus Electronix Deep Purple 405 Premium Inspection Lantern Operations Guide

DT304. Digital Temperature Logger INSTRUCTION MANUAL

FOR YOUR PERMANENT FILE

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Tracer ORP PockeTester TM Code 1742

12VDC TO 230VAC INVERTERS

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

TRACER. POCKETESTER ä ORP CODE 1742

operating manual DL7 101 DIGITAL THERMOMETER

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Remote-adjustable Radiator Controller HR 40 F. Mounting and Operation

Owner's Manual. Rapid Charger. 4-Hour. Port USB Charger. and Portable Power Pack. for AA/AAA Ni-MH & Ni-Cd Rechargeable Batteries

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Thermocouple Thermometer Models

FOR YOUR PERMANENT FILE

ValveSentry USER S MANUAL REVISED 8/6/16 IMPORTANT! PLEASE READ CAREFULLY AND SAVE

USER MANUAL MOMENTS COLLECTION

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

User s Manual Power Supply IM E. 5th Edition

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Advanced Calibration Designs, Inc. Release II

Universal Battery Holder Operator s Manual

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

SOLAR SECURITY LIGHT with MOTION SENSOR

Differential Pressure Transmitter

Product Data Sheet : LIGHTHAWK 6 CELL

Digital/Analog Megohmmeter Model 1026

6 Bay Battery Charger Operation Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

BUTTON CELL CR2450S BRIEF SPECIFICATION

OPERATING INSTRUCTION

Thermistor Thermometer MODEL NO

Visit us at

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

1.Safe testing IMPORTANT:

Table of Contents. CLS-420 Wireless Version. CLS-920i Wired Version. CLS-920i Wireless Version. lift truck CLS-420 Wired Version

Transcription:

USER GUIDE Moisture Meter Model MO210

Introduction Thank you for selecting the Extech Model MO210. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Safety Notes Do not exceed the maximum allowable input range of any function. Set the function switch OFF when the device is not in use. Remove the battery if the device is to be stored for longer than 60 days. Never dispose of batteries in a fire. Batteries may explode or leak. Never mix battery types. Always install new batteries of the same type. Warnings Set function switch to the appropriate position before measuring. Do not measure current on a circuit whose voltage exceeds 600V. When changing ranges always disconnect the test leads from the circuit under test. Cautions Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live". If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 2

Description Meter Description 1. Measurement electrode pin 2. Cutoff switch 3. LCD (detail below) 4. Hand grip 5. Verification Test Points 6. Battery check Test Points 7. Removable cap 8. Material Selector Switch Display Description 1. Graphical Display 2. Numerical Reading 3. Units 4. Low Battery Indicator 5. Solid lines even number 6. Dashed lines odd number 5 6 2 2 3 3 1 4 4 5 6 Wood Scale Building Material Scale 3

Operation CAUTION: The electrode measurement pins are extremely sharp. Use care when handling this instrument. Cover the pins with the protective cap when the instrument is not in use. 1. Remove the protective cap to expose the electrode pins. 2. The meter automatically switches ON when the cap is removed. 3. The meter automatically shuts OFF when the cap is replaced. 4. To conserve battery life, the meter automatically shuts off after 15 minutes when the cap is left off. To revive the meter after an Auto Power OFF, simply press the yellow cut-off switch momentarily. 5. Slide material selection switch to read wood moisture or building moisture. 6. Carefully push the electrode pins as far as possible into the material under test. Note that the pins should be inserted into wood perpendicular to the wood s fiber structure. 7. Take several readings in several locations on the material for the best representation of the amount of moisture present. 8. Read the measurement values on the display. 9. Replace the protective cap when finished. Reading the Display 1. The LCD display has two scales 2. The wood scale indicates wood moisture from 6 to 44%. 3. The building materials scale indicates moisture content from 0.2 to 2.0%. 4. A continuous line indicates an even number. A dotted line indicates on odd number. 5. The battery icon appears when the batteries are weak and require replacement. Auto Power OFF With the protective cap removed, the meter will turn off after 15 minutes to conserve battery life. Press the yellow cutoff switch momentarily to restart the meter. Always secure the protective cap when the instrument is not in use. Instrument Measurement Verification check 1. With the meter wood moisture position, touch the Wood Scale Building Material Scale electrode test pins to the two test points 1 and 2 at the top of the protective cap labeled T. 2. With the unit on and the electrode pins touching the T test points, the meter should read 27% ±2%. If not, the meter may require repair. Battery Check 1. With the meter wood moisture position, touch the electrode test pins to the two test points 3 and 4 at the top of the protective cap labeled B (see diagram). 1 3 B 2 4 2. With the unit on and the electrode pins touching the B test points, the meter should read > 44% on the wood moisture scale. If not, replace the batteries. T 4

Battery Replacement If the instrument does not switch on, displays the low battery symbol, or if the Battery Check yields less than 44% on the wood moisture scale, replace the batteries as follows: 1. Remove the Phillips head screw from the belt clip/battery compartment located on the rear of the instrument. 2. Remove the batteries taking note of their orientation and polarity. 3. Install three (3) new CR-2032 button batteries observing polarity. 4. Secure the battery compartment with the Phillips head screw. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle. Battery Safety Reminders Please dispose of batteries responsibly; always observe local, state, and federal regulations with regard to battery disposal. Never dispose of batteries in a fire. Batteries may explode or leak. Never mix battery types. Always install new batteries of the same type. Electrode Pin Replacement To replace the two electrode pins: 1. Remove the protective cap 2. Unscrew the electrode pins 3. Install the new pins 4. Replace the protective cap Maintenance Always keep the instrument dry Prevent dirt from accumulating at the electrode pins 5

Specifications Display Dual measurement scale LCD with bargraph metering Measurement principle Electrical resistance Range Wood: 6 to 44%, Building materials: 0.2 to 2.4% Electrode length 9.5mm (0.375 ) Electrode pins Integrated, replaceable Auto Power OFF After approx. 15 minutes Power supply Three (3) CR-2032 button cells Meter housing Impact-proof plastic Operating Temperature 0 to 40 o C (32 to 104 o F) Operating Humidity 85% Relative Humidity maximum Dimensions 130 x 40 x 25mm (5.1 x 1.6 x 1.0 ) Weight 108.3g. (3.82 oz) Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 6