Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Similar documents
LEGISLATIVE FRAMEWORK

2017/SOM3/SCSC/JRAC/010 Agenda Item: 6a

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

LIST OF PUBLISHED STANDARDS

SHEDULE 1(A) Serial No. Serial No. HS Codes Article Column III Article Column IV. HS Codes Article Column III Article Column IV

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LIST OF PUBLISHED STANDARDS

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

CERTIFICATION BODY ACCREDITATION PROGRAM (CBAP) Scope of Accreditation

About us. Switchgear Factory, Mumbai

IMPORTS SUBJECT TO SRI LANKA STANDARDS

Products Under Mandatory Labeling with Self-Declaration of Conformity As required under Republic Act No (Consumer Act) HOUSEHOLD APPLIANCES

LIST OF PUBLISHED STANDARDS

A List of Standards Often Used for Designing Electrical Systems and for Specifying Equipment

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

Particular requirements (apply as applicable to luminaire type) Emergency Escape Lighting and Exit Signs for Buildings

CHAPTER V RESIDENTIAL WIRING

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Spring Test 10 due 05/11/2013

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

Volume 2 Charts, Formulas, and Other Useful Information

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

Other DC motors; DC generators: Of an output not exceeding 750 W 5% kg and No

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

UNIT 6: BATTERIES, UPS AND CABLES

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

Demonstrate knowledge of electrical theory for Electrical Service Technician B

Standards Update Notice (SUN) Issued: June 6, 2017

Our annual production capacity is 3000 tons for copper and 4000 tons for PVC.

NEC 2011 Code Changes

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

STANDARDS SOUTH AFRICA. Amendment No. 5 : May SANS :2006 (Ed 1.5) THE WIRING OF PREMISES PART 1: LOW-VOLTAGE INSTALLATIONS

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

SYLLABUS. osmania university UNIT - I UNIT - II UNIT - III CHAPTER - 1 : ELECTRIC HEATING ELECTRIC WELDING CHAPTER - 2 : CHAPTER - 3 :

ELECTRIC POWER AND HOUSEHOLD CIRCUITS

NZQA registered unit standard version 1 Page 1 of 5

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

City & Guilds 2381 Test 2382 Level 3. Which one of these electrical installations does BS 7671:2008 not apply to:

Generator Fire Safety: Generator assemblies should be located outside the building.

ELECTROTECHNICAL Letter of Authority (LOA) ADMINISTRATION PROCEDURE

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

Chapter 8 Interior Wiring and Lighting

Year 11 GCSE PHYSICS REVISION QUESTIONS PAPER 1. Higher Level. Energy and Electricity

Grid Plus. technical hotline +44 (0) modular wiring devices

production program 1

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

FTS600P FTS800P FTS1200P

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

D R A F T SUMMARY. Excludes certain battery charger systems from definition of battery charger system for purposes of energy efficiency standards.

Trade of Metal Fabrication. Module 1: Basic Fabrication Unit 15: Electricity Phase 2

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Scale of Inspection Fees of Electrical Inspectorate Schedule. I. Fees for Initial Inspections:

Current Electricity Basics Worksheet Current Definition C of charge pass a point in a wire in 3.0 ms. How much current is this?

Modular contactor for installation into distribution boards

Class X Chapter 09 Electrical Power and Household circuits Physics

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Load Resistors Testing Resistors

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

CERTIFICATE OF ACCREDITATION

Unified requirements for systems with voltages above 1 kv up to 15 kv

The graphs show the voltage across two different types of cell as they transfer the last bit of their stored energy through the torch bulb.

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

SECTION MOTOR REQUIREMENTS for HVAC

EI30MH55GBA EI30MH55GSA EI30MH55GWA EI30MH55GZA

LB - LIGHTING BUSWAY 25-40A

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

Table 3:List of Mandatory Omani Standards

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

Power & Control Cable IEC

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

table of contents Lampholders for Innovative Light Sources SECTION C CS ECTION

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

DRAFT: SOUTH AFRICAN NATIONAL STANDARD

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Electric Vehicle Charging Safety Guidelines Part 1: Safety Fundamentals Edition DRAFT

E-12 Low-voltage Switchboard

DOMINO Series surface mounting IP55

CERTIFICATE OF ACCREDITATION

Domae. The right solution for distribution boards

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

P High Voltage Catalogue Cables Australia Powering your Project

High Voltage Copper, Smooth Aluminum Shield/Sheath

Switchgear for Luminaires

UV-AIRE AIR PURIFYING SYSTEM

ASEAN SECTORAL MRA ON ELECTRICAL AND ELECTRONIC EQUIPMENT (ASEAN EE MRA) LISTING OF THE DESIGNATED CONFORMITY ASSESSMENT BODIES

Transcription:

17065:2012 to provide product conformity certification 1, Place des Alpes CH-1211 Geneva Switzerland Contact: Patricia Lumbreras Tel: +(511) 221 1159 E-Mail: patricia.lumbreras@sgs.com Locations where certification activities covered by the above Accreditation Standard are undertaken Switzerland SGS Société Générale de Surveillance SA 1, Place des Alpes CH-1211, Geneva Philippines 20th Floor, Citibank Tower Paseo de Roxas Makati City 1200 Manila Philippines Assessment Manager: GH Page 1 of 20

DETAIL OF ACCREDITATION Electrical Products & Electrical Apparatus Conformity assessment of goods to be exported in to the Kingdom of Saudi Arabia SGS Scheme Document Electrical Product Safety (Batch Certification) D3-GIS-13-CC-08 SGS Scheme Document Electrical Product Safety (Product Registration) D3-GIS-13-CC-09 SGS Scheme Document Electrical Product Safety (Product Licensing) D3-GIS-13-CC-10 For the following standards:- Audio, video and similar electronic apparatus Audio, Video and similar electronic apparatus - Safety requirements Ordinary television receivers. Low power radio frequency devices. Sound broadcast radio receiver - Part 2: General requirements. Electrical supply track systems for luminaires -Part 2: Mixed supply systems - Section 1: Classes I and III. Equipment for speech audiometry Sound system equipment - Part 4 : microphones Sound system equipment - Part 5 : loudspeakers Sound system equipment. Part 1: General IEC 60065:2001 SASO-GSO-60065-2008 SASO-IEC-60065-2009 SASO-1278-1998 SASO-1322-1997 SASO-1323-1997 SASO-1673-2000 SASO-1969-2001 SASO-2222-2004 SASO-2223-2004 SASO-2717-2007 Assessment Manager: GH Page 2 of 20

Cables and cords Conduit Systems for Electrical Installations Part 1: General Requirement Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible Cables(Cords) Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 6: Lift cables and Cables for Flexible connections Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Screened and unscreened flexible cables with two or more conductors. Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 1 General Requirements Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 3 Heat resistant silicone insulated cables Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 4 - Cords and Flexible Cables Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 5 Lift cables Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 6 Arc welding electrode cables Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 7 Heat resistant ethylenevinyl acetate rubber insulated cables IEC 60227-1: 2007 IEC 60227-3:1997 IEC 60227-4:1997 IEC 60227-5:2011 IEC 60227-6:2001 IEC 60227-7:2011 IEC 60245-1:2008 IEC 60245-3:2008 IEC 60245-4:2011 IEC 60245-5:1994 IEC 60245-6:1994 IEC 60245-7:1994 Assessment Manager: GH Page 3 of 20

Cables and cords (cont d) Rubber Insulated Cables-Rated Voltage up to and Including 450/750V Part 7 Cords for applications requiring high flexibility IEC 60245-8:2012 Enamelled wire IEC 60317-0-1:2013 And the IEC 60317-XX series of standards Power cables with extruded insulation and their accessories for rated voltages from 1kV (um = 1,2 kv) up to 30 kv (Um = 36kV) - Part 1: Cables for rated voltages of 1kV (Um = 1,2 kv) and 3 kv ( Um = 3,6kV) Power cables with extruded insulation and their accessories for rated voltages from 1kV (um = 1,2 kv) up to 30 kv (Um = 36kV) - Part 2: Cables for rated voltages of 6 kv (Um = 7,2 kv) up to 30 kv ( Um = 36 kv) PVC - insulated cables with circular copper conductors Commercial Annealed Aluminum Electrical Conductor Wire Aluminum- Magnesium - Silicon Alloy Wire For Overhead Line Conductors. Low - Frequency Cables And Wires With PVC Insulation And PVC Sheath - Part 2 : Telephone Wire For Inside Application Round Wire Concentric Lay Overhead Electrical Stranded Conductors Low frequency cables with polyolefin insulation and moisture barrier polyolefin sheath - Part1:General design details Low frequency cables and wires with PVC insulation and PVC sheath Part 3: Equipment wires with solid or stranded Zinc-Coated steel wires for stranded conductors. Aluminum-clad steel wires for electrical purposes. IEC 60502-1:201 IEC 60502-2:2005 SASO-55-1984 SASO-786-1994 SASO-787-1994 SASO-1346-1998 SASO-1347-1998 SASO-1594-1999 SASO-1839-2001 SASO-1841-2001 SASO-1980-2001 Assessment Manager: GH Page 4 of 20

Cables and cords (cont d) Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Chapter 52: Wiring systems. Rubber insulated cables - rated voltages up to and including450/750 v Power cables with extruded insulation and their accessories for rated voltages above 150 kv (um=170 kv) up to 500 kv (um=550kv)-test methods and requirements Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations Coaxial communication cables - Part 8-2: Detail specification for 50-047 type semi-flexible cables with solid polytetrafluoroethylene (PTFE) insulation SASO-1985-2001 SASO-2036-2002 SASO-2435-2005 SASO-2599-2006 SASO-2600-2006 SASO-IEC-61196-8-2-2012 Conduit systems for cable management Specification for conduit fittings for electrical installations Part 1: General requirements Cable trunking and ducting systems for electrical installations Part 1: General requirements Conduit systems for cable management - Part 1: General requirements Conduit systems for cable management -- Part 21: Particular requirements - Rigid conduit systems Conduit systems for cable management -- Part 22: Particular requirements - Pliable conduit systems Conduit systems for cable management -- Part 23: Particular requirements - Flexible conduit systems Conduit systems for cable management -- Part 24: Particular requirements - Conduit systems buried underground IEC 61035-1:1990 and the -2-XX series of standards IEC 61084-1:1991 and the -2-XX series of standards IEC 61386-1:2008 IEC 61386-21:2002 IEC 61386-22:2002 IEC 61386-23:2002 IEC 61386-24:2004 Assessment Manager: GH Page 5 of 20

Conduit systems for cable management (cont d) Plastic conduits and fittings for electrical installations. SASO-255-2007 Metal conduits and fittings for electrical installations. Cable trunking and ducting systems for electrical installations - part2: particular requirements-section1: Cable trunking SASO-1901-2001 SASO-2756-2008 Controls and Switches for appliances Automatic electrical controls for household and similar use Switches for domestic purposes. IEC 60730-1:1999 and the -2-XX series of standards SASO-51-1977 Galvanic cells and batteries Primary batteries - Part 1: General IEC 60086-1:2011 SASO-IEC 60086-1-2007 Primary batteries - Part 2: Physical and electrical specifications IEC 60086-2:2011 SASO-IEC 60086-2-2007 Primary batteries - Part 3: Watch batteries IEC 60086-3:2011 SASO-IEC 60086-3-2007 Primary batteries - Part 4: Safety of lithium batteries IEC 60086-4:2011 SASO-IEC 60086-4-2007 Primary batteries - Part 5: Safety of batteries with aqueous electrolyte Lead-acid starter batteries - Part 1: General requirements and methods of test Lead-acid starter batteries Part 2: Dimensions of batteries and dimensions and marking of terminals Lead-acid starter batteries Part 4: Dimensions of batteries for heavy trucks Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests IEC 60086-5:2011 SASO-IEC 60086-5-2007 IEC 60095-1: 2006 IEC 60095-2:2009 IEC 60095-4:2008 SASO-IEC 60095-4-2009 IEC 60896-11:2002 SASO-IEC 60896-11-2007 Assessment Manager: GH Page 6 of 20

Galvanic cells and batteries (cont d) Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application Batteries for use in photovoltaic power systems Specification Part 2: Modified lead acid batteries Secondary cells and batteries containing alkaline or other non-acid electrolytes Secondary lithium cells and batteries for portable applications Lead-acid starter batteries used for motor cars & internal combustion engines. Dry primary batteries. Lead-acid starter batteries used for motor vehicles and internal combustion engines. IEC 60896-22:2004 SASO-IEC 60896-22-2007 IEC 61427-1:2013 IEC 61427-2:2013 IEC 61960:2000 SASO-IEC 61960-2007 SASO-27-1984 SASO-269-1982 SASO-1919-2001 Assessment Manager: GH Page 7 of 20

Household and Similar Electrical Appliances Household and similar electrical appliances IEC 60335-1:2010 and the -2-XX series of standard SASO 1062-2007 and the -2-XX series of standard in SASO-GSO-60335-2-XX and SASO-IEC-60335-2-XX Evaporative Air Coolers (Desert Coolers) Domestic electric fans. Household Electric clothes washing machine. Drinking water coolers. Storage-type electric water heaters for household use. Electric Cooking Ranges. Commercial refrigerated cabinets for the sale and /or display of food products-part1: General requirements. Water centrifugal pumps - general requirements Household and similar electrical appliances - Safety -- Part 2-28: Particular requirements for sewing machines Safety of household and similar electrical appliances part2: particular requirements section34 : motor - compressor Safety of Household and Similar Electrical Appliances Part 2: Particular Requirements - Section 9: Grills, Toasters and Similar Portable Cooking Appliances Household and similar electrical appliances Safety - Part2: Particular requirements -section 14 :kitchen machines Safety of household and similar electrical appliances Part 2: Particular requirements -Section 21: Storage water heaters. Safety of Household and Similar Electrical Appliances - Part 2: Particular Requirements Section 8: Shavers Hair Clippers and Similar Appliances SASO-35-2011 SASO-112-1979 SASO-141-1979 SASO-415-2007 SASO-532-2008 SASO-1236-2009 SASO-1303-1997 SASO-1305-1997 SASO-1348-1998 SASO-1367-1998 SASO-1600-2009 SASO-1601-2005 SASO-1698-2000 SASO-1604-2009 Assessment Manager: GH Page 8 of 20

Household and Similar Electrical Appliances (cont d) Commercial refrigerated cabinets for the sales and /or display of food products - technical specification -Part 2-: Particular requirements. Safety of household and similar electrical appliances - Part 2-95: Particular requirements for drives for vertically moving garage doors for residential use. Vertical turbine water pumps - general requirements For Column pipe Assembly Safety of household and similar electrical appliances - Part 2: Particular requirements-section 11: Tumble dryers. Household and similar electrical appliances - Safety -- Part 2-56: Particular requirements for projectors and similar appliances Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers Safety of household and similar electrical appliances - Part 2: Particular requirements - Section16: Food waste disposers. particular requirements for stationary cooking ranges, hobs, ovens and similar appliances Particular requirements for Sauna heating appliances Particular requirements for ironers Household and similar electrical appliances - Safety - Part 2-75: Particular requirements for commercial dispensing appliances and vending machines Safety of household and similar electrical appliances - part 2: Particular requirements - section 10: Floor treatment machines and wet scrubbing machines Energy Labelling and Minimum Energy Performance Requirements for Air-Conditioners SASO-1707-2000 SASO-1821-2001 SASO-1972-2001 SASO-1977-2001 SASO-2136-2003 SASO-2007-2006 SASO-2026-2002 SASO-2370-2009 SASO-2371-2005 SASO-2603-2006 SASO-2606-2006 SASO-2135-2003 SASO-2663-2012 Assessment Manager: GH Page 9 of 20

Household and Similar Electrical Appliances (cont d) Energy Performance, Capacity and Labelling of Household Refrigerators, Refrigerator-Freezers and Freezers Energy Labelling Requirement of Clothes Washing Machines for Household Use Safety and performance requirement for window airconditioners and their method of test SASO-2664-2007 SASO-2692-2007 SASO-2763-2008 Insulation and insulating materials Flexible insulating sleeving - Part 1: Definitions and general requirements Specifications for pressure-sensitive adhesive tapes for electrical purposes Adhesive insulating tapes for electrical purposes. Poly(vinyl chloride) insulation for wire and cable Poly(vinyl chloride) jacket for wire and cable Specification for pressure-sensitive adhesive tapes for electrical purposes Part 1: General requirements IEC 60684-1:2003 IEC 60454-1-1992 SASO-232-1994 SASO-2048-2002 SASO-2049-2002 SASO-GSO-60454-1-2010 IT, Office and Telecommunications Equipment Information technology equipment - Safety -- Part 1: General requirements IEC 60950-1:2005 SASO-GSO-60950-1-2012 SASO-2551-2006 Low-voltage switchgear and controlgear assemblies Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways) IEC 60439-1:1999 IEC 60439-2:2000 Assessment Manager: GH Page 10 of 20

Low-voltage switchgear and controlgear assemblies (cont d) Low-voltage switchgear and controlgear assemblies - Part 3: Particular requirements for low-voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use - Distribution boards Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites(acs) Specification for low-voltage switchgear and controlgear - Part 1: General requirements Specification for low-voltage switchgear and controlgear - Part 2: Circuit-breakers Specification for low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch disconnectors and fuse combinations Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines IEC 60439-3:1991 IEC 60439-4:1990 IEC 60947-1:2007 and the -4-XX series of standards and the -5-XX series of standards and the -6-XX series of standards and the -7-XX series of standards IEC 60947-2:2006 IEC 60947-3:2008 IEC 60947-8:2003 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation Circuit-breakers for overcurrent protection for household and similar installations. Circuit - Breakers for equipment A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 Kv and up to and including 52 KV. Residual current operated circuit-breakers without integral overcurrent protection for house hold and similar uses (RCCBs) Part 1 : General rules IEC 60898: 2003 SASO-1349-1998 SASO-1612-1999 SASO-2003-2002 SASO-2611-2006 Assessment Manager: GH Page 11 of 20

Lamps/Lighting equipment and accessories Tungsten filament lamps for domestic and similar general lighting purposes - Performance requirements IEC 60064:2005 Edison screw lampholders IEC 60238:2011 SASO-60238-2011 Lampholders for tubular fluorescent lamps and starterholders Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes IEC 60400:2011 IEC 60432-1:2012 SASO-IEC-60432-1-2010 IEC 60432-2:2012 Luminaires - Part 1: General requirements and tests IEC 60598-1:2008 and the -2-XX series of standards SASO-GSO-60598-1-2010 SASO-1318-1997 Particular requirements High-pressure sodium vapour lamps Self-ballasted lamps for general lighting services - Safety requirements SASO-1674-2000 SASO-1675-2000 SASO-1676-2006 SASO-1677-2000 SASO-1679-2000 SASO-1680-2000 SASO-1681-2000 SASO-1682-2000 SASO-1683-2006 SASO-1684-2000 SASO-1685-2000 SASO-1686-2000 SASO-1687-2006 SASO-1688-2000 SASO-1689-2000 SASO-1690-2000 SASO-2569-2006 SASO-2721-2007 SASO-2722-2007 IEC-60662-2011 IEC 60968:2012 Assessment Manager: GH Page 12 of 20

Lamps/Lighting equipment and accessories (cont d) Self-ballasted lamps for general lighting services - Performance requirements Transformers for tubular discharge lamps having a noload output voltage exceeding 1000 V (generally called neon-transformers). General and safety IEC 60969:2001 IEC-61050-1991 SASO-IEC-61050-2007 Bayonet lampholders IEC 61184:2011 Double-capped fluorescent lamps - Safety specifications IEC 61195-2012 SASO-GSO-61195-2010 Lamp controlgear IEC 61347-1:2007 and the -2-XX series of standards and SASO-IEC-61347-2-XX series of standards and SASO-GSO-61347-2-XX series of standards LED modules for general lighting - Safety specifications Discharge Lamps (Excluding fluorescent) - Safety Requirements Tungsten filament lamps for domestic and similar general lighting purposes Tungsten filament lamps for domestic and similar general lighting purposes Tubular fluorescent lamp for general lighting service. Starters for fluorescent lamps. Bayonet lamp holder for general use Ballasts for tabular fluorescent lamps. Ballasts for high pressure mercury vapour lamps. High pressure mercury vapour lamps. High - pressure sodium vapour lamps D.C supplied electronic ballast for tubular fluorescent lamps: Performance requirements IEC-62031-2008 SASO-IEC-62031-2008 IEC 62035:2012 SASO-GSO-62035-2010 SASO-33-1998 SASO-34-1998 SASO-139-1979 SASO-147-1979 SASO-234-1981 SASO-508-2001 SASO-692-1994 SASO-1131-1998 SASO-1350-1998 SASO-1372-1998 Assessment Manager: GH Page 13 of 20

Lamps/Lighting equipment and accessories (cont d) D.C. Supplied electronic ballasts for tubular fluorescent lamps general and safety requirements. A.C. supplied electronic ballasts for tubular fluorescent lamps - General and safety requirements. Ballasts for discharge lamps (excluding tubular fluorescent lamps) general and safety requirements Auxiliaries for lamps - ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements. Auxiliaries for lamps - Starting devices (other than glow starters) - General and safety requirements. Auxiliaries for lamps - Starting devices (other than glow starters) performance requirement A.C.-supplied electronic ballasts for tubular fluorescent lamps - Performance requirements. Electrical supply system for luminaires Self-Ballasted lamps for general lighting services: Safety requirements. Self-Ballasted lamps for general lighting services: Performance requirements. Metal halide lamps. Capacitors for use in tubular fluorescent and other discharge lamp circuits Auxiliaries for lamps - capacitors for use in tubular fluorescent and other discharge lamp circuit - general and safety requirements Lamp controlgear - Part 2-1-particular requirement for starting devices(other than glow starters) D.C or A.C supplied electronic step-down convertors for filament lamps-performance requirement SASO-1488-1999 SASO-1489-1999 SASO-1491-1999 SASO-1492-1999 SASO-1493-1999 SASO-1494-1999 SASO-1671-2000 SASO-1672-2005 SASO-1894-2001 SASO-1895-2001 SASO-1982-2001 SASO-1984-2001 SASO-2013-2002 SASO-2014-2000 SASO-2015-2002 Assessment Manager: GH Page 14 of 20

Lamps/Lighting equipment and accessories (cont d) Maximum lamp outline for incandescent lamps Tungsten halogen lamps(non vehicle)-performance specification Incandescent lamps-safety specifications Part 3 Tungsten halogen lamps (non-vehicle) Lamp controlgear Part 1: General and Safety requirements Single-capped fluorescent lamp-performance specifications Single- capped fluorescent lamp-safety specification Lighting of work places -- Part 2: Lighting requirements for safety and security of outdoor work places Lighting of indoor work places Glow-starters for fluorescent lamps High-pressure sodium vapour lamps Ballasts for tubular fluorescent lamps Performance requirements SASO-2367-2005 SASO-2571-2006 SASO-2570-2006 SASO-2602-2006 SASO-2719-2007 SASO-2720-2007 SASO-2811-2010 SASO-2814-2010 SASO-GSO-60155-2011 SASO-IEC-60662-2011 SASO-GSO-60921-2011 Assessment Manager: GH Page 15 of 20

Measurement, Control and laboratory equipment Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 11: Metering equipment Electricity metering equipment (AC) Acceptance Inspection - Part 11: General acceptance inspection methods IEC 62053-11:2003 SASO-IEC-62058-11-2010 Class 0.5, 1, 2 Induction type watt-hour meter SASO 426-1998 Electronic commercial balances. Safety requirements for indicating and recording electrical measuring instruments and their recording accessorie Safety Requirements for electrical equipment for measurement, control,and laboratory use-part 1: General requirements Safety Requirements for electrical equipment for measurement, control,and laboratory use-part 2-032:particular requirements for hand-held and handmanipulated current sensors for electrical test and measurement Safety Requirements for electrical equipment for measurement, control,and laboratory use-part 031:safety requirements for hand-held probe assemblies for electrical measurement and test SASO-537-1994 SASO-1224-1998 SASO-2416-2005 SASO-2417-2005 SASO-2418-2005 Assessment Manager: GH Page 16 of 20

Medical Electrical Equipment Medical electrical equipment Part 1: General requirement for basic safety and essential requirements Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source Medical Electrical Equipment - Part 2-13: Particular Requirements for the Safety of anaesthetic machines. Medical electrical equipment Part 2-6 : Particular requirements for the safety of microwave therapy equipment Medical electrical equipment- Part 2-18: particular requirements for the safety of endoscopic equipment Medical electrical equipment- Part 2-19: particular requirements for safety of baby incubators Medical electrical equipment- Part 2-10: Particular requirements for the safety of nerve and muscle stimulators Medical electrical equipment- Part 2-4: Particular requirements for the safety of cardiac defibrillators Medical electrical requirement Part 2-2: Particular requirements for the safety of high frequency surgical equipment Medical electrical equipment- Part 2-3: Particular requirements for the safety of short-wave therapy equipment IEC 60601-1:2005 SASO-IEC-60601-2-31-2011 SASO-1889-2001 SASO-2297-2005 SASO-2373-2005 SASO-2694-2008 SASO-2695-2008 SASO-2753-2008 SASO-2754-2008 SASO-2277-2004 Photovoltaic equipment Crystalline silicon terrestrial photovoltaic (PV) module - Design qualification and type approval Thin-film terrestrial photovoltaic (PV) modules - Design qualification and type approval Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction IEC 61215: 2005 SASO-IEC 61215-2006 IEC 61646:2008 IEC 61730-1:2004 SASO-IEC 61730-1-2008 Assessment Manager: GH Page 17 of 20

Rotating Machines Rotating electrical machines - Part 1: Rating and performance Air-cooled electric motors. IEC 60034-1:2010 SASO-IEC 60034-1-2007 SASO-609-1994 Switches for household and similar fixed electrical installations Switches for household and similar fixed-electrical installations - Part 1: General requirements Switches for domestic purposes. IEC 60669-1:2007 and the -2-XX series of standard SASO-GSO-60669-1-2010 and the -2-XX series of standard SASO-51-1977 Electric Tools Safety of hand-held motor-operated electric tools IEC 60745-1:2006 and the -2-XX series of standard and SASO-GSO-60745-2-XX series of standard Safety of transportable motor-operated electric tools - Part 1: General requirements IEC 61029-1:1990 and the -2-XX series of standard Transformers, reactors and power supplies - Power transformers - Part 1: General IEC 60076:2011 Specification for safety of power transformers, power supply units and similar apparatus Uninterruptible power systems (UPS) - Part 1: General and safety requirements for UPS Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations IEC 61558-1:2005 and the -2-XX series of standard SASO-IEC 61558-1-2007 and the -2-XX series of standard IEC 62040-1:2008 SASO-IEC 62040-1-2009 IEC 62040-1-5-2007 SASO-IEC 62040-1-2-2007 Assessment Manager: GH Page 18 of 20

Transformers, reactors and power supplies (cont d) Instrument transformers - Part 1: General requirements Instrument transformers - Part2 : Current transformers Instrument transformers - Part 2 : Inductive voltage transformers Instrument transformers - Part 5: Capacitor voltage transformers Power transformers. Power transformers - Part 1 : General Instrument transformers - Part 3: Combined transformers Instrument transformers - Part 6: Requirements for protective current transformers for transient performance Instrument transformers - Part 7: Electronic voltage transformers Instrument transformers - Part 8: Electronic current transformers IEC-61869-1-2007 SASO-IEC-61869-1-2009 IEC-61869-2:2012 SASO-2301-2005 IEC-61869-3:2011 SASO-2560-2006 IEC-61869-5:2011 SASO-2748-2007 SASO-422-1994 SASO-1606-1999 SASO-2561-2006 SASO-2562-2006 SASO-2594-2006 SASO-2595-2006 Wiring Accessories Plugs and socket-outlets for household and similar purposes - Part 1: General requirements Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 1: General requirements Boxes and Enclosures for Electrical Accessories for Household and Similar Fixed Electrical Installations Pt 23: Particular Requirements for Floor Boxes and Enclosures IEC 60884-1:2013 and the -2-XX series of standard IEC 60670-1:2002 IEC 60670-23:2006 Assessment Manager: GH Page 19 of 20

Wiring Accessories (cont d) Boxes and Enclosures for Electricity Accessories for Household and Similar Fixed Electrical Installations Pt 24: Particular Requirements for Housing Protective Devices and Similar Power Consuming Devices Pressure type thermostats for use in house hold electrical appliances. Plugs, socket-outlets and couplers for industrial purposes Part 1: General requirements. Low-voltage fuses- Part 1: General requirements. Electrical relays-part5 insulation tests for electrical relays Plugs and socket-outlets for Household and similar General use 220V Plugs and socket-outlets for Household and similar General use 125V General requirements for enclosures for accessories for house hold and similar fixed electrical installations Low-voltage fuses Part 2 : Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) Plugs, socket-outlets and couplers for industrial purposes -Part 2: Dimensional inter changeability requirements for Pin and contact-tubes accessories Safety requirements for cord extension sets IEC 60670-24:2011 SASO-704-1993 SASO-1693-2000 SASO-1899-2001 SASO-2018-2002 SASO-2203-2003 SASO-2204-2003 SASO-2684-2007 SASO-2685-2007 SASO-2686-2007 SASO-2815-2010 END Assessment Manager: GH Page 20 of 20