MODEL 151B FIRE DAMPER

Similar documents
INSTALLATION INSTRUCTIONS MODEL KFD-555

LLOYD INDUSTRIES INC.

Standard Installation Fire Damper Models: 319, 319(SS), D39

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Fusible Link (replaceable) Horizontal Mount

Fire Dampers Catalogue

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Fusible Link (replaceable) Horizontal Mount

SMOKE DAMPER - CLASS F MODEL BMSD

table of contents PRODUCT SUMMARY 2

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Fire, Smoke, and Combination Fire Smoke Dampers

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

BC 03. Fire Dampers FD-GB-30-AS LISTED

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Part # Installation,Operation and Maintenance Instructions

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

CFSD Series. Product Description

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SECTION CENTRIFUGAL HVAC FANS

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

Model FSD-212. Combination FIRE SMOKE DAMPERS

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

PRODUCTS BULLETIN PRODUCTS CATALOGUE

Motorized Fire Dampers

SECTION AXIAL HVAC FANS

Installation, Operation and Maintenance Manual

SECTION HVAC POWER VENTILATORS

CURTAIN TYPE FIRE DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

MULTI-BLADE FIRE DAMPERS

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

EGG CRATE RETURN GRILLE

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

We make dampers easy for you!

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

Installation, Operation and Maintenance Manual

MULTI-BLADE FIRE DAMPERS

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

SD-1250 and SD-1600 Series Smoke Dampers

Installation, Operation and Maintenance Instructions

SECTION DUCTWORK ACCESSORIES

Introduction to Johnson Controls Dampers

Smoke Dampers. Installation Instructions

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

PERFORMANCE SPECIFICATIONS SINGLE-SPEED, 110 CFM VENTILATION FAN

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

CEILING & INLINE/CABINET VENTILATORS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

Model ND-2 Specification

University of Delaware

AIR DUCT ACCESSORIES

Filtered Kitchen Supply Packaged Ventilator

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

SINGLE DUCT TERMINAL UNITS

Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Product Catalog Edition 4

4 Installation Guidelines

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

ceiling & inline/cabinet ventilators

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

Model VCD-20 3V CONTROL DAMPER

Qualified for installation in wood joist ceiling construction. CRD-1WT. Fire Dampers. Model

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Transcription:

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Stock ID: IOM-151B January, 2003 2003 Miami Tech Inc., Inc. Miami, FL Miami Tech T Inc. MODEL 151B FIRE INSTALLATION INSTRUCTIONS The City of New York 909-89-SM California State Fire Marshall 3225-1382:100

151B FIRE I.O.M. Miami Tech Inc. Foreword This publication details the installation requirements for dynamic application fire dampers as manufactured by Miami Tech Inc.. Use of this manual for systems or products not manufactured or supplied by Miami Tech Inc. shall not be applicable. All products covered by this manual have been tested in accordance with UL555 and are authorized to bear the UL classification mark for fire dampers. Specific Fire Damper model numbers and their corresponding UL file numbers may be found in UL s Fire Resistance Directory. For specific fire damper location requirements, duct construction and connection or installation practices, refer to the following codes or standards: NFPA Publications: NFPA 90A - Standard for the Installation of Air-Conditioning and Ventilation Systems UL Publications: UL555 - Standard for Safety, Fire Dampers SMACNA Publications: Fire, Smoke and Radiation Damper Installation Guide for HVAC Systems Guide HVAC Duct Construction Standards Metal and Flexible The Installation Instructions found within this manual have been specifically drawn and detailed to meet the requirements of UL555. Some jurisdictions may require additional or different installation methods; therefore, consult with the authority having jurisdiction for specific differences. For these cases, the requirements defined by the authority having jurisdiction will take precedence over the documents contained herein. 2 Miami Tech, Inc. 3611 NW 74 Street. Miami, FL 33147 305-693-9396 www.miamitech.com

Miami Tech Inc. I.O.M. 151B FIRE Model 151B 1.5 Hour Single Section Dynamic Fire Damper HORIZONTAL MOUNTING (Model 151B) VERTICAL MOUNTING (Model 151B) 5 2 1 STEEL 3 CLEARANCE: 1/8" PER LINEAR FT. CEILING WALL OR OTHER PARTITION CEILING WALL OR OTHER PARTITION 1 STEEL 4 ANGLES AIR DUCT 3 CLEARANCE: 1/8" PER LINEAR FT. 1-1/2 HR. UL CLASSIFIED MODEL 151B FIRE 4 ANGLES IMPORTANT: FOR VERTICAL MOUNTING BLADE STACK MUST BE TOP AS SHOWN 6" MAXIMUN EACH SIDE (TYP. HORIZONTAL & VERTICAL) AIR DUCT 1-1/2 HR. UL CLASSIFIED MODEL 151B FIRE Fusible Link 165 F 5 NOTES: 1. Sleeve shall be of the same or heavier gauge as the duct to which it is attached. Gauges shall conform to SMACNA or ASHRAE Duct Standards. When the following duct-sleeve connections are used, minimum gauge of the sleeve shall be 16 gauge on dampers not exceeding 36" wide x 24" high and 14 gauge on larger dampers: (a) angle reinforced standing seam, (b) angle reinforced pocket lock, (c) companion angle, or (d) metal fasteners spaced approximately 16" on center. Refer to the latest edition of UL 555 for connections which may be used in all systems. 2. Damper is secured to sleeve by the use of either 1/4" diameter steel nuts and bolts, No. 10 sheetmetal screws, 1/4" diameter steel rivets, or 1/2" long welds...all of which must be 6" on center and a maximum of 1 3/4" from the ends. 3. Fire dampers shall have clearance of 1/8" per linear foot on width and height. The unit (damper and sleeve) may rest on the bottom of the opening and need not be centered. 4. Retaining angles shall be a minimum of 1 1/2" x 1 1/2" x 16 gauge steel. Angles increase in size proportionally, so that there will be a minimum of 1" overlap on the partition, and angles must also cover corners of opening. 5. The sleeve is retained in the partition opening by the use of either 1/4" diameter steel nuts and bolts, No. 10 sheetmetal screws, 1/4" diameter steel pop rivets or 1/2" long welds...all of which must be 6" on center and no more than 2" from the ends. Devices are to attach angle to sleeve only. 6. This installation is for dampers which are to be installed in masonry walls only. See Alternate Framing Methods on page 5. 7. Connecting ducts shall be terminated at the sleeve or transition collar where a draw-band type breakaway joint is used. 8. Maximum duct size of single section Model 151B unit is 24" wide x 24" high. Miami Tech Inc. 3611 NW 74 Street Miami, FL 33147 305-693-9396 www.miamitech.com 3

FIRE GENERAL INFORMATION Miami Tech T Inc. What is a Fire Damper? The National Fire Protection Association (NFPA) Standard 90A defines a fire damper as a device, installed in an air distribution system, that is designated to close automatically upon detection of heat, to interupt migratory airflow, and to restrict the passage of flame. Types of Curtain Fire Dampers: Curtain type Fire Dampers are available in three configurations. Type A Type B Type C Blades & Frame in Airstream. Blades out of Airstream. This provides better free flow area and pressure drop than Type A. Blades and frame are out of Airstream; primarly used when transitioning to round or square duct. Type C provides maximum pressure drop characteristics with blades and frame out of airstream. STATIC TIC RATED OR DYNAMIC RATED, WHATS THE DIFFERENCE? Underwriters Laboratories (UL) Standard for Safety 555 catagorizes smoke and fire control systems as either static or dynamic. UL555 defines dampers intended to close under no airflow conditions as dampers for static systems, and dampers intended to close under flow conditions as dampers for dynamic systems. As of July 1, 2002, all Dynamic Fire Dampers must meet the new UL555 Standard. This Standard changes the way Dynamic Fire Dampers are tested. The new Standard requires all manufacturers to retest to a stricter requirment. This insures better designed and built dampers. Miami Tech Inc. Model 151 has been tested and has passed in both Vertical and Horizontal Installation. Did you know?... Fire Dampers must be mounted in a steel sleeve. The damper and sleeve assembly is held in place by using retaining angles on each side of the wall. Ductwork shall be connected to eigther side with a break away connection. This allows the damper to remain in the wall in the event that ductwork fall during a fire. All necessary mounting products are available from Miami Tech Inc. 4 Miami Tech Inc. 3611 NW 74 Street Miami, FL 33147 305-693-9396 www.miamitech.com

Miami Tech Inc. ALTERNATE FRAMING METHODS Model 150 & 151 Alternate Framing Methods Fire Resistive Material Connection Angle with 1" overlap Minimum Opening to be lined with Fire Resistive Material of Rating Equal to that on the Wall Wood Stud Straps wrapped around metal stubs may be used on some UL approved fire damper assemblies in place of angle iron frames Fire Damper Sleeve Optional lining of opening: Local Authorities may require openingto to be lined with fire resistive material of rating equal to that on the wall for some fire damper installations. Connection Metal Stud NOTES: 1. Thickness and type of fire resistive material may vary with the jurisdiction. Specific framing requirements of openings should be provided in the architectural and structural drawings that are submitted for building permits. 2. Sleeve shall be 14 gauge when the following duct-sleeve connection is: (a) angle reinforced standing seam, (b) angle reinforced pocket, (c) companion angles, (d) metal fasteners spaced approximately 16" on center. Refer to latest edition of UL 555 for connections with may be used in all systems. Gauges shall conform to SMACNA or ASHRAE Duct Standards. 3. Damper is secured to sleeve by the use of either 1/4" diameter steel nuts and bolts, No. 10 sheetmetal screws, 1/4" diameter steel rivets, or 1/2" long welds...all of which must be 6" on center and a maximum of 1 3/4" from the ends. 4. Fire dampers shall have clearance of 1/8" per linear foot on width and height. The unit (damper and sleeve) may rest on the bottom of the opening and need not be centered. 5. Retaining angles shall be a minimum of 1 1/2" x 1 1/2" x 16 gauge steel. Angles increase in size proportionally, so that there will be a minimum of 1" overlap on the partition, and angles must also cover corners of opening. 6. The sleeve is retained in the partition opening by the use of either 1/4" diameter steel nuts and bolts, No. 10 sheetmetal screws, 1/4" diameter steel pop rivets or 1/2" long welds...all of which must be 6" on center and no more than 2" from the ends. Devices are to attach angle to sleeve only. 7. For Horizontal Mount Dampers, the assembly is formed by using a full length 1/8" by 5" wide mullion plate with 1/4" diameter steel nuts and bolts, spaced 6" on center and a maximum of 3/4" from corners attaching frames to mullion plate. 8. For Vertical Mount Dampers, the damper frames are butted together and fastened with either No. 10 x 3/4" long sheetmetal screws, 1/4" diameter steel rivets, 1/4" diameter steel nuts and bolts, or 1/2" long welds...all of which must be spaced at 4" on center and maximum of 3/4" from corners of dampers. 9. Connecting ducts shall be terminated at the sleeve. 10. Maximum duct size of single section vertical only unit is 24" wide x 24" high. Miami Tech Inc. 3611 NW 74 Street Miami, FL 33147 305-693-9396 www.miamitech.com 5