DESCRIPTION RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today s popular ceiling systems and is available with a number of options and accessories for application versatility. The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Catalog # Project Comments Prepared by Metalux Date SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral rid-lock feature for safety and convenience. Controls The RLN LED is Powered by Fifth Light, with a standard -1V continuous dimming driver that works with any -1V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the RLN can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 1%, for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-Life LED system coupled with electrical driver to deliver optimal performance. LED s available in 3K, 3K or 4K with a minimum CRI of 8. Projected life is 6, hours at 93% lumen output. culus listed. Electronic drivers are available for 12-277V applications. Emergency Battery Pack Option Optional 12V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 9-minute batteries provide constant power to the LED system, ensuring codecompliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 9% reflective white enamel for superior performance. Hinging/Latching Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. Frame/Sheilding Die formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens. Compliance Modules are UL recognized components and indoor luminaires are culus listed for 2ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-8 standards. DesignLights Consortium Qualified and classified for DLC Standard, refer to www. designlights.org for details. Warranty Five year warranty. 24RLN LED 2' X 4' TROFFER LED MODULE Specification rade Troffer Rectilinear Shielding RECTILINEAR 3-1/4" [83mm] 23-3/4" [63mm] MOUNTIN DATA DOOR FRAMES CERTIFICATION DATA 23-3/4" [63mm] 47-1/16" [1218mm] RLN Flat, White Steel culus198 Damp Location Listed IC Rated LM79/LM8 Compliant ROHS Compliant DesignLights Consortium Qualified 47-3/4" [1212mm] Safe and convenient means of disconnecting power
24RLN LED RECTILINEAR SHIELDIN CEILIN COMPATIBILITY rid/lay-in Standard Concealed T Slot rid Ceiling Exposed rid Concealed T Slot rid Trim (Verify compatibility/ consult factory.) ENERY AND PERFORMANCE DATA BY CATALO NUMBER Stock or Delivered Efficacy Watts MTO* Catalog Logic (Rectilinear Shielding) Lumens (lm/w) MTO 24RLN-LD-31-UNV-L83-CD1-U 32 22.9 133 MTO 24RLN-LD-31-UNV-L83-CD1-U 3179 22.9 139 MTO 24RLN-LD-31-UNV-L84-CD1-U 3179 22.9 139 MTO 24RLN-LD-36-UNV-L83-CD1-U 3 26. 132 MTO 24RLN-LD-36-UNV-L83-CD1-U 361 26. 138 MTO 24RLN-LD-36-UNV-L84-CD1-U 361 26. 138 MTO 24RLN-LD-42-UNV-L83-CD1-U 44 31.2 129 MTO 24RLN-LD-42-UNV-L83-CD1-U 428 31.2 13 MTO 24RLN-LD-42-UNV-L84-CD1-U 428 31.2 13 MTO 24RLN-LD-4-UNV-L83-CD1-U 436 34. 128 STOCK 24RLN-LD-4-UNV-L83-CD1-U 447 34. 134 STOCK 24RLN-LD-4-UNV-L84-CD1-U 447 34. 134 MTO 24RLN-LD--UNV-L83-CD1-U 48 37.8 127 MTO 24RLN-LD--UNV-L83-CD1-U 37.8 132 MTO 24RLN-LD--UNV-L84-CD1-U 37.8 132 MTO 24RLN-LD--UNV-L83-CD1-U 332 42.7 12 STOCK 24RLN-LD--UNV-L83-CD1-U 4 42.7 13 STOCK 24RLN-LD--UNV-L84-CD1-U 4 42.7 13 MTO 24RLN-LD-6-UNV-L83-CD1-U 79 47.7 121 MTO 24RLN-LD-6-UNV-L83-CD1-U 999 47.7 126 MTO 24RLN-LD-6-UNV-L84-CD1-U 999 47.7 126 MTO 24RLN-LD-67-UNV-L83-CD1-U 648 3.9 12 MTO 24RLN-LD-67-UNV-L83-CD1-U 67 3.9 12 MTO 24RLN-LD-67-UNV-L84-CD1-U 67 3.9 12 MTO 24RLN-LD-74-UNV-L83-CD1-U 7136 61.6 116 MTO 24RLN-LD-74-UNV-L83-CD1-U 7433 61.6 121 MTO 24RLN-LD-74-UNV-L84-CD1-U 7433 61.6 121 MTO 24RLN-LD-8-UNV-L83-CD1-U 773 67. 11 MTO 24RLN-LD-8-UNV-L83-CD1-U 87 67. 119 MTO 24RLN-LD-8-UNV-L84-CD1-U 87 67. 119 *Made to order (MTO) requires a typical four week lead time. LUMEN MAINTENANCE Ambient Temperature 9 CRI TM-21 Lumen Maintenance (6, hours) Theoretical L7 (Hours) 2 C > 93% > 31, Lumen Adjustment Factors 8->9 CRI 3K.86 3K.861 4K.883 K n.a. Example of Lumen Adjustment Calculation 24RLN-LD-4-UNV-L93-CD1-U at 9CRI at 3K Lumen Adjustment Factor =.861 Total Light Output = 4,47 lm x.861 = 3,914 lm Efficacy = 3,914 lm = 11.1 lm/w 34 W Peachtree City, A 3269 P: 77-486-48
24RLN LED RECTILINEAR SHIELDIN PHOTOMETRICS 444 888 1332 1776 Coefficients of Utilization 24RLN-LD-4-UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.2 x mounting height, ( ) 1.21 x mounting height Lumens: 447.1 Input Watts: 34W Efficacy: 133.7 lm/w Test Report: 24RLN-LD-4-UNV- L83-CD1-U.IES Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 7 8 8 9 1774 1774 1774 1767 1762 1771 1738 1733 1741 1689 1684 1693 1619 1617 1629 134 133 147 1434 1432 1448 1318 1317 1332 1197 1194 124 16 162 169 934 92 929 83 79 788 662 6 646 32 12 42 376 366 278 22 241 166 14 126 67 48 4 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 89 91 89 87 8 1 92 8 8 97 9 84 79 86 81 77 83 79 7 8 77 73 71 91 81 73 67 89 79 72 66 76 7 6 74 68 64 71 67 63 6 84 72 63 7 81 71 63 6 68 61 6 66 6 64 8 4 2 77 64 6 49 7 63 49 61 4 48 9 3 48 7 2 47 4 71 8 49 43 69 7 49 43 48 42 4 47 42 2 46 42 4 66 3 44 38 64 2 44 38 43 38 49 42 37 48 42 37 3 62 48 4 34 6 48 4 34 46 39 34 4 38 34 44 38 33 32 8 44 36 31 6 44 36 31 43 36 31 42 3 3 41 3 3 28 4 41 33 28 3 4 33 28 39 33 28 39 32 28 38 32 28 26 42 18 1627 2169 Coefficients of Utilization 24RLN-LD--UNV- L83-CD1-U Electronic Driver Linear LED 3K Spacing criterion: (II) 1.2 x mounting height, ( ) 1.21 x mounting height Lumens: 4. Input Watts: 42.7W Efficacy: 13.1 lm/w Test Report: 24RLN-LD--UNV- L83-CD1-U.IES Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 1 2 2 3 3 4 4 6 6 7 7 8 8 9 2167 2167 2167 216 211 2162 2124 2117 2129 261 29 267 1979 1977 1989 1871 1872 189 1748 171 1769 1612 161 163 1462 146 1472 134 1298 131 1142 113 114 976 964 962 814 792 783 649 623 613 492 49 44 34 38 289 24 17 16 81 9 48 rc 8% 7% % 3% 1% % rw 7 3 1 7 3 1 3 1 3 1 3 1 RCR 1 2 3 4 6 7 8 9 1 1 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 16 16 16 12 12 12 1 19 1 11 97 17 12 99 9 98 9 92 94 92 89 91 89 87 8 1 92 8 8 97 9 84 79 86 81 77 83 79 7 8 77 73 71 91 81 73 67 89 79 72 66 76 7 6 74 68 64 71 67 63 6 84 72 63 7 81 71 63 6 68 61 6 66 6 64 8 4 2 77 64 6 49 7 63 49 61 4 48 9 3 48 7 2 47 4 71 8 49 43 69 7 49 43 48 42 4 47 42 2 46 42 4 66 3 44 38 64 2 44 38 43 38 49 42 37 48 42 37 3 62 48 4 34 6 48 4 34 46 39 34 4 38 34 44 38 33 32 8 44 36 31 6 44 36 31 43 36 31 42 3 3 41 3 3 28 4 41 33 28 3 4 33 28 39 33 28 39 32 28 38 32 28 26 Zonal Lumen Summary Zone Lumens % Fixture -3 131 29.7-4 2178 47.9-6 37 81. -9 447 1. -18 447 1. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 237 23 2316 2144 211 214 1928 186 1812 164 1491 1426 1177 844 73 Zonal Lumen Summary Zone Lumens % Fixture -3 161 29.7-4 266 47.9-6 426 81. -9 4 1. -18 4 1. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 282 2812 2838 266 274 269 232 228 2222 212 1823 171 1423 137 844 Peachtree City, A 3269 P: 77-486-48
24RLN LED RECTILINEAR SHIELDIN ORDERIN INFORMATION SAMPLE NUMBER: 24RLN-LD-4-UNV-L83-CD1-U Rating Blank= Standard ATW-SW4= Chicago Rated Series (7) 24RLN=2x4 RLN Series Door Frame Standard=Flat White Steel Door (Leave Blank) Lamp LD=LED. Stock Lumen Output 4=4 Lumen = Lumen MTO Lumen Output 31=31 Lumen 36=36 Lumen 42=42 Lumen = Lumen 6=6 Lumen 67=67 Lumen 74=74 Lumen 8=8 Lumen Shielding Blank=Standard Lens RDP=Rectilinear with Round Pattern Insert Voltage (2) 347V=347 Volt (9) UNV =Universal Voltage 12-277 Options Emergency EL7W=7-watt, 12V-277V emergency battery pack installed (3) EL14W=14-watt 12V-277V emergency battery pack installed (3) Driver CD=-1V Dimming Driver (1% - 1% Dimming) HCD=-1V Dimming Driver (1% - 1% Dimming) (8) SD=Step-Dim Driver (6) LTD=Fifth Light DALI Driver (4), (6) (1% - 1% Dimming) SR=Sensor Ready (1% to 1% dimming) (12) Number of Drivers 1=1 Driver 2=2 Drivers TD2=Bodine enerator Transfer Device (1) ETS2=IOTA Emergency Transfer Switch (1) CCT L83=3K L83=3K L84=4K L93=3K L93=3K L94=4K Flex () Multiple Configurations Available Integrated Solutions S=Integrated Sensor (11) L=LumaWatt Control V=Analog (-1V) Output for Local Control (11) W=WaveLinx (11) WI=Wireless Integral (12) (13), (14) WT=Wireless Tile Occupancy Technology P=Passive Infrared Sensing Technology D=Dimming Daylight Harvesting (Closed Loop) Coverage Pattern 1= ~144 Square Feet Packaging U=Unit Pack PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) DF-24-W=2' x 4' Drywall Frame Kit DF1P-C =Decorator Dimmer, -1V SF1P- =Decorator Slide Dimmer, -1V SK-24-WS=Field Install Surface Mount Kit, Shallow SK-24-WT=Field Install Surface Mount Kit, Tall ISHH-1=Programming Remote for Integrated Sensor ISHH-2=Personal Control Remote for Integrated Sensor NOTES: (1) An EQ rid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2) Products also available in non-us voltages and frequencies for international markets. (3) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (1 lm/w x 7=7 lumens). IES-format photometry for luminaire under emergency operation available. (4) Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light visit systems () Flex does not include dimming leads. Control leads provided by others. (6) 31, 36 Lumen packages not available with Step- Dim (SD) and Fifth Light (LTD) driver option. (7) DesignLights Consortium Qualified and classified for DLC Standard/Premium (all lumen packages), refer to www.designlights.org for details. (8) Two HCD drivers are required for 74 and 8 lumen packages. (9) 347V versions are not available with emergency options. (1) Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (11) Integral sensors work with CD and HCD drivers only and is factory prewired to the driver for stand-alone control. (12) SR driver compatible with LWI option only. (13) LWT compatible with CD and HCD drivers only. (14) LWT sensor is external to luminaire, cable factory wired. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit www.eaton.com/lumawattpro. Specifications & Consult your Representative for availability and ordering information. SHIPPIN DATA Catalog No. 24RLN-LD-4 24RLN-LD- Wt. 1 lbs. 1 lbs. Peachtree City, A 3269 P: 77-486-48
LO SET MIN INTERATED SENSOR 24RLN LED RECTILINEAR SHIELDIN The RLN with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RLN delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RLN delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-1). The integrated sensor personal remote (Catalog Number: ISHH-2) provides code compliant manual raise, lower, ON, OFF control. The RLN with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 2 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. 1 Energy Savings Opportunities Light Level (DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level (DU) Unoccupied Level Unoccupied Occupied Unoccupied Occupied Target light level default: lux at 8 ft. Coverage Top View C L 3.3m [1 ft.] Side View m [ ft.] Major Motion m [ ft.] m [ ft.] Reccomended Mounting Height 8 12 ft. Optional Remote Control Raise/ Lower Time Out HI 1 ES 1 7 2 Occ MAX To Set Output Un Occ 1. Raise, Lower or Press Min., 7, Max. 2. To save press SET 3. Select Occ or Un Occ Programming Remote ISHH-1 ISHH-1 Remote Peachtree City, A 3269 P: 77-486-48