Electric Vehicle Supply Equipment EVSE Vehicle Simulator

Similar documents
TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

OpenEVSE. Testing Basic and Advanced

Electric Vehicle Supply Equipment Basics Review

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Abstract. GLV Systems Test Plan 1

TRAVEL CORDSET AND WALL STATION TEST REPORT

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Mobility & emobility

INSTRUCTION & INSTALLATION

USER GUIDE TURBOCORD TM PORTABLE CHARGER 240V. AeroVironment EV Solutions

EMERGENCY VEHICLE BATTERY MANAGER PS2024

58kHz AM Deactivator DB104 Instruction Manual V1.0

CHARGE TANK. Overview. Using The Charge Tank. User Guide

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Plugless Level 2 EV Charging System (3.3kW)

REVISED ATM72 Auto Transfer Module

INTELEPOWER CXS SWITCHING SYSTEMS

Managing Electric Vehicle Supply Equipment (EVSE) Installations

OutdoorXUPS-600AHV-8364

Galvanic Isolator. Instruction Leaflet

CAUTION-ELECTRICALLY OPERATED PRODUCT

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

12VDC TO 230VAC INVERTERS

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

SUM340 SUMMATION BOARD

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

INSTALLATION GUIDE AND USER MANUAL

SAM Series Power Inverter

Installation Manual & Warranty

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

Clipsal Lifesaver Portable Power Outlet with RCBO protection 485 Series

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

Post evolve Series. Installation Manual

PowerMax. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.

PRO-WAVE INVERTER 12 VOLT, PURE SINE WAVE. P/No.s PW150, PW350, PW600, PW900 & PW1800

RAY TYPE 1 PRODUCT MANUAL

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Operations and Service Manual. X30208 Load Bank

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Installation and Operating Instructions. Solar System Controller ISC3020

Instruction Manual for model CB1 Check Box

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Post evolve Series. Installation Manual

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

Power Product Specifications

Application Engineering

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Application Engineering

Fiber Optic Illuminator. Model 21AC Model 21DC

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

USERS MANUAL MCD REMOTE OPERATOR

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

RESIDUAL CURRENT CIRCUIT BREAKER

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

EV CHARGER REQUIREMENT LEV READY

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

X100P Load Bank. Read all instructions before using the load bank. Contents

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Matson Jump Starter Operator s Manual

Problems with your 12/24V Booster?

ELECTRICAL SYSTEM RP-7

OPERATION & MAINTENANCE INSTRUCTIONS

PowerOhm Installation Manual for BM R Series Braking Modules

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Electric Vehicle Charging Station

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

USER GUIDE. AeroVironment EV Solutions Charging Station Model EVSE-RS Plug-in

PowerOhm Installation Manual for LG ATV Series Braking Modules

Door Operator Conversion Package: Type M to PM/SSC or HPM/SSC with Board 1Ø4

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

SUBMERSIBLE WATER PUMPS

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

WF-5110R True Sine Wave Inverter

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

EVlink. Cluster Cabinet Including EVlink MS Energy Management and EVlink MS Supervision Recommendation Guide 04/2013.

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

JUMP STARTER OPERATOR S MANUAL RA1900

Elmdene International Ltd

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

USER GUIDE. 100% electric. AeroVironment EV Solutions Charging Dock Model EVSE-RS Plug-In

Transcription:

Electric Vehicle Supply Equipment EVSE Vehicle Simulator Equipment design and Operating Instructions GS1007 A Technicians Service Tool to enable the functional, safety and operation of an installed EVSE in regard to all EV vehicle interfaces.

EVSE Simulator Operating Instructions Model GS-1007 This EVSE Simulator is designed to allow full functionality testing of a SAE J1772 compliant EV Charger Fixed or Mobile charger. The EVSE Simulator can only be used with a fully compliant EV Charge system that has the SAE J1772 protocol employed. The EVSE Simulator load output voltage is protected by a 25A CB. GELCOservices Pty. Ltd. 16 Dawson St FULLARTON SA 5063 Australia PO Box 404, FULLARTON SA 5063, Australia Phone: +61 8 8338-4388 Mobile: +61 407 726 106 E-mail: gell@internode.on.net Web: www.gelcoservices.com.au ABN 78 288 709 971 The instructions are to be followed to ensure the correct Level 2 EV Charger testing is accomplished. DANGER: High Voltage present EVSE Simulator face panel identification: Load current test loop used with a Hall Effect Amp clamp to measure Amps output under load AC Volt Meter indicates all high voltage systems functional. Control Pilot Signal test push button 25Amp circuit breaker Carry handle Twin Proximity Signal LED s Twin load outlets 240 volt, 10 Amps SAE J1772 AC Inlet Connector from EV Charger plugs into this AC Inlet socket 1

The EVSE Simulator is designed to enable a Level 2 Mobile or static EV Charger to be connected and various functions can be simulated. EVSE power ready recognition EVSE connected to vehicle function EVSE charge delivery function EVSE Control Pilot Signal communication test EVSE Proximity signal operation test. Load test to a safe 2.5Kw capacity. The EVSE Simulator is powered entirely from the output of the EV Charger system, thus fully replicating the connection to a vehicle. Be sure EVSE Simulator is placed on a firm dry area before using. Simulated load, using radiant heaters 240 volts AC as typical of the output of the EVSE charger to the EV in Level 2 format. Operation Instructions: 1. Do not use this EVSE Simulator in wet, rainy or extremely high humidity conditions without adequate protection 2. The EVSE Simulator will take the 240VAC 50Hz or 60Hz outputs from the EV Charger SAE J1772 connector and deliver the simulation. 2

3. The load bank is designed to be a simple radiant heater device with a maximum capacity of 2400 watts. DO NOT attempt to exceed this load rating. 4. Power up the EVSE and be sure all self checks are performed. 5. Place the Heater Load Bank well clear of any flammable materials. DO NOT plug in the two heaters to the EVSE Simulator at this time. 6. Connect the EV Charger J1772 Connector to the J1772 AC Inlet socket on the EVSE Simulator. 7. The EV Charger will recognise that it is connected to the EVSE Simulator by illuminating the Vehicle Connected LED on the EV Charger. 8. The EV Charger will then engage the internal Contactors which will be recognised by a loud click and followed by the EV Charger vehicle charging LED being illuminated 9. The Voltmeter on the EVSE Simulator will indicate 240VAC is being delivered. 10. The green Proximity Signal 5 volt DC LED will illuminate on low power. 11. The red Proximity Signal LED correct circuit will illuminate on low power The EVSE Simulator is now ready for functionality testing. Control Pilot Signal Test: 1. Maintain the EV Charger SAE J1772 connector to the AC Inlet socket. 2. Press the red Control Pilot Signal button on the Simulator face panel and the Vehicle Charging and Vehicle Connected LED s on the EV Charger will extinguish. 3. The Voltmeter will return to zero volts 4. Release the Control Pilot Signal red press button and the EV Charger will engage the internal Contactors and once again indicate the Vehicle Connected and Vehicle Charging LED s will illuminate.. 5. Press the Proximity button on the EV Charger J1772 Connector and remove the Connector from the AC Inlet. 3

6. The EV Charger will immediately dis-engage the internal power contactor and extinguish both the Vehicle Charging LED and the Vehicle Connected LED 7. If all above functions test correctly then the Control Pilot Signal operation is fully functional. Proximity Test: 1. Leave the EV Charger unit on and connected to the EVSE Simulator. 2. Leave the EV Charger SAE J 1772 Connector in the AC Inlet socket. 3. Note the glowing green (5 VDC being delivered) and red (J1772 Connector circuit engaged) LED s are operating. 4. Press the Proximity button on top of the J1772 EV Connector as though you were going to remove the EV Charger Connector from the car. 5. Visually both the green and red LED s will increase in light intensity, thus demonstrating that the release button reed switch for the Proximity Signal is operating. 6. As the Simulator is not gaining access to the Command Logic of the EV itself, there is no disconnect function transmitted to the EV Charger. 7. Confirm that both LED s light emission intensifies, and if so then the Proximity Signal function is all correct. Load Test: 1. Leave the EV Charger unit on and connected to the EVSE Simulator. 2. Leave the EV Charger SAE J 1772 Connector in the AC Inlet socket. 3. Note the Voltage reading as indicated on the Voltmeter. should be 240 VAC. 4. Plug in both Heaters from the Load Bank. 5. Switch on each heater in turn by pulling the switch activation cord located on each Heater. Two pulls to reach maximum heat radiation. 6. Note the EVSE Simulator voltage as delivered should remain at 240 VAC. 4

7. DO NOT use non recommended Heaters as an alternate or additional Load Bank. The system protection CB will trip if this is done. Load Current AMPS Test: 1. Leave the EV Charger unit on and connected to the EVSE Simulator. 2. Leave the EV Charger SAE J 1772 Connector in the AC Inlet socket. 3. Note the Voltage reading as indicated on the Voltmeter. should be 240 VAC. 4. Plug in both Heaters from the Load Bank. 5. Switch on each heater in turn by pulling the switch activation cord located on each Heater. 6. Place a Hall Effect Amp Clamp around the Load Current Test Loop and register to display Amps in AC Mode. Be sure to select correct Amp range and zero tester before placing on loop. 7. With full load as detailed above 2400Watts, the current draw should be around 10.26-10.50 Amps. GFCI (RCD) Earth Leakage Testing: The following procedure allows the regular compliance testing for GFCI (RCD) operation of the EVSE. 1. Insert the Digitech QP-2000 Power Point and Earth Leakage Tester into one of the Level 1-10/15 amp AC outlets. 2. Read the illuminated neon s to be sure both top neon s are lit, indicating AC Outlet is correctly wired and that there is power delivered to this AC Outlet. 5

3. To determine ELCB trip levels simply slide the switch from 10mA up toward 100mA, pressing the RCD test button at each leakage calibration. The EVSE should trip before 100mA. Switch positions are 10mA, 15mA, 30mA and 100mA. An AeroVironment EVSE-RS charger is set at 30mA. 4. The Tester should trip the permanently installed RCD at the 30mA switch position. Using the Volt Finder determine that the 240 VAC delivery to the Level 1 AC Outlet is no longer present. 5. Check that the two neon s on the Tester are also NOT illuminated. 6. The EVSE Charge Controller Computer performs this GFCI process every time the SAE J1772 connector is engaged with the Electric Vehicle. 7. Should a GFCI fault be found then the EVSE will deliver a red illuminated LED TROUBLE and shut down power delivery. 8. The technical representative will demonstrate the GFCI trip, using a specially developed EVSE EV Car simulator. Test re-set is by activating the Control Pilot signal circuit. Closing Down Tests: 1. Turn off Load Bank 2. Remove heater plugs from EVSE Simulator 3. Allow heaters to cool before moving 4. Remove SA J1772 Connector All tests complete. Record results on Commissioning Form. Support: EVSE Simulator Constructed and Supplied by: GELCOservices Pty. Ltd. 16 Dawson St Fullarton South Australia 5063 Australia Contact: +61 407 726 106 www.gelcoservices.com.au 6