MEDMASTER EXTERNAL POWER SUPPLY

Similar documents
INSTALLATION INSTRUCTIONS

MEDMASTER CLEANSCENE MRI/Imaging Suite Luminaires

MEDMASTER DOWNLIGHT Luminaires for MRI Applications

Options AMF Antimicrobial Finish (All Exposed Surfaces) BLK Black Doorframe. Accessory

SAVE THESE INSTRUCTIONS

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Air Curtain. Installation, Operating and Maintenance Instructions

MaxLite LED UTILITY WRAP FIXTURES

User s Manual and Operating Instructions

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

BMRX Series ROTARY LEVEL CONTROL

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

DC to AC Power Inverters

DC to AC Power Inverters

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

SAVE THESE INSTRUCTIONS

ADI-125/750 ADI-125/1500 ADI-125/2500

MIL-24/2600Q MIL-24/3200DQ

INSTALLATION & OPERATION MANUAL

User Guide IGD Series

OWNERS MANUAL JANUARY 2007 ISO

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

C3000 SIGNAL TRANSMITTER. Introduction

LED LARGE WALL PACK (CUTOFF & STANDARD)

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Integrated Heating System

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

INSTALLATION & OPERATION MANUAL

Installation Manual Stand-Alone Dispenser Pan Sensor

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

HBC-20 - LED HIGH BAY

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Compressor Duty Motor - 1 HP. Model 40132

Thermoelectric Cooling System. Model 5473

EnForcer 100. Universal 100W Solid State Power Supply VAC input power. Indoor or Outdoor enclosures to suit most applications

Kitchen Tech Series Air Curtain

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

User s Manual and Operating Instructions

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

AEROMOTIVE Part # / L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Flex Tube. User guide

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Pure Sine Wave Inverter 600W-24V User Manual

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

DISC BRAKE CALIPER TOOL SET

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

Operators Manual. Recirculating Chiller /06/08

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Installation Manual for the SHURflo LCB - G Pump Controller

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

MaxLite LED Linear HighBay Fixtures

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

OWNERS MANUAL JANUARY 2007 ISO

PVI 60KW, PVI 82KW, PVI 95KW

Project: Type: Qty: QH2L. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole. Options

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

LED IMPORTANT SAFETY INSTRUCTIONS

PSX-240 Enclosed Autotransformer Installation Manual

AEROMOTIVE Part # L Mustang Digital FMU INSTALLATION INSTRUCTIONS

SUBMERSIBLE POND PUMP

RU BMS Power Supply and Battery Management System Owners Guide

Go Power! Manual. GP-Smart Charger

Power Inverter 400 MW Owner s Manual

AEROMOTIVE Part # L Ford F L Ford Expedition L Ford F-250 Super Duty INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Positive Displacement Pump

MaxLite LED Enclosed & Sealed Jelly Jars

40º 14 1 / Plaster Frame 6. Plaster Skim Coat (by others) ORDERING INFORMATION:

60 Watt Industrial LED Low Bay Light

INSTALLATION & OPERATION MANUAL

WARNINGS, CAUTIONS AND NOTES

MAXIGARD A2000 SPEED SWITCH. Introduction

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Heavy Duty Industrial Foot Switches

Video & Power Over Coax Kit

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

G3PE-Single-phase. Solid State Relays for Heaters

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

INSTALLATION NOTES: nbeckon-26

INSTALLATION INSTRUCTIONS

16 Inch Hanging Pendant Barn Light

Universal Retrofit System Installation Instructions Revised:

Installation & Operation Manual PWS1000R Rack Mount Power Supply

Effective June 1, 2013 This guide supersedes all previous versions

TO AVOID DOING IRREPARABLE DAMAGE TO DRIVE CIRCUITRY NEVER APPLY AC POWER DIRECTLY TO LED LIGHTBOXES!

20250 Module Installation Guide

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Transcription:

PROJECT INFORMATION Job Name MEDMASTER EXTERNAL POWER SUPPLY MRIPS-312 SERIES PRODUCT FEATURES: Recommended for MRI CleanScene, Downlight, Auracyl Sconce, Stratalume Undercabinet and Envela Remote mounted outside EMI shielded structure 13.5" 8.5" Provides DC Power to MedMaster MRI luminaires ETL Listed power supply and enclosure Fixture Type Catalog Number Approved by SPECIFICATIONS HOUSING: Die formed marine grade extruded aluminum. Black TGIC polyester powder coat finish 5-stage pre-treatment; Salt spray test: 1,000 hours. ELECTRICAL: INPUT: 120~240 VAC, 50/60 Hz. Active PFC Function, PF>0.95. OUTPUT: Constant-voltage DC output. Factory preset at 24VDC, adjustablerange 20~26.4VDC. Maximum current load 13ADC. WARRANTY: This product is warranted by Kenall Manufacturing to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the enclosure carries a five-year warranty from the date of invoice. Warranty is void if all wiring is not completely shielded in grounded conduit. LISTINGS: Power supply is certified to UL1012 and CSA C22.2 No. 107.1 by Intertek Testing Services. Dry Location only. NOTE: See Kenall luminaire specifications that utilize remote power supplies for use with this unit. INSTALLATION WIRING/CONDUIT: All power and signal wiring must be completely shielded in grounded conduit. Total length of low-voltage supply wires, at least 18AWG, from power supply to filter to luminaires, should not exceed 50 feet (15m). EMI FILTERS: All MRI room EMI filters must be sized as suitable for power supply load (supplied by others). AMBIENT TEMPERATURE/HUMIDITY: The surrounding ambient temperature must remain below 104 F (40 C). The working temperature is between -20~+65 C. Allowable relative humidity is 20~90% non-condensing. PRODUCT LOCATION: The MRIPS-312 power supply must be installed outside the shielded MRI environment. It contains ferrous components that can damage or interfere with MRI equipment. A minimum free-air spacing must exist of 3" around all sides and 6" over exhaust fan. Location should not allow excessive dirt/dust to clog ventilation holes and prevent internal air circulation. MRI LUMINAIRES CONNECTION PER POWER SUPPLY 8.41 13.50 2.94 Amps Max. Luminaires per per Power Supply Luminaires Luminaire per room CSMRI22.35 28 CSMRI24 0.7 16 CSMRI44 1.4 8 MRIDL6 (13L) 0.8 13 MRIDL6 (23L) 1.2 8 MRIDL6 (31L) 1.7 6 MRIMAS813 (6W) 0.4 28 MRIMAS813 (14W) 0.7 16 MRIMAS826 1.0 10 MRIMAS838 1.3 8 MRIMAS850 1.7 6 MRIAUC 18 0.7 16 MRIAUC 36 1.4 8 ME11MRI 1.4 8 LPS5MRI-12 0.7 16 LPSR5MRI-12 0.7 16 at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. 2016 Kenall Mfg. Co. All rights reserved. MRIPS-312-072817

MEDMASTER External Power Supply for MRI Luminaires MRIPS SERIES INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: 1 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS This instruction sheet applies for the Kenall MRIPS-312 External Power Supply. It describes the proper mounting procedure and wiring instructions for singular and multiple fi xture confi gurations. A separate instruction sheet is provided with the MRI luminaire(s). Both sheets together are intended to provide comprehensive instructions on system installation and electrical wiring. The Kenall MRIPS-312 power supply and EMI fi lter (by others) must be installed outside the shielded MRI environment. It contains ferrous components that can damage or interfere with MRI equipment.

2 Power Supply Mounting Procedure Follow instructions provided with the luminaires for the proper installation procedure. Make electrical connections to power supply after luminaires are mounted. 1. Locate suitable mounting location for the power supply. Location should be chosen based on the following requirements: A. Ambient Temperature/Humidity: The surrounding ambient temperature must stay below 104 F (40 C). Allowable relative humidity is 20~90% non-condensing. Product is rated for DRY locations only. B. Wire Distance: The length of 24V DC supply wires from power supply to luminaires should not exceed 50 feet (15m). In multiple-luminaire confi gurations, this is the distance to the last luminaire in the run. C. Ventilation Hole Spacing: Maintain at least 3 of free-air spacing must exist around all sides and at least 6 over exhaust fan. D. Contaminants: Location should not allow excessive dirt/dust to clog ventilation holes and prevent internal air circulation. 2. Securely mount enclosure to a mechanically-sound surface. Use hardware appropriate for the installation (not provided). Single Power Supply Wiring Procedure Use the following procedure if only one power supply is to be connected in this installation. Refer to page 3 for multiple power supply installations. 3. Open wire access cover to expose wiring compartments (see Figure 1). 4. Secure conduit to low voltage and line voltage compartments using either the front or side KO locations. Class 1 wiring is required. 5. Make 120-240VAC, 50/60Hz supply connections on line voltage side. Make sure proper ground is connected. NOTE: 24VDC and Dimming Wires to be run through same conduit.

3 6. Run conduit and DC wiring to an MRI room EMI fi lter sized to the load of the power supply (supplied by others). See Figure 2. Make sure wiring is completely enclosed in grounded conduit. Any gaps, regardless of size, must be closed or wrapped in copper foil tape. 7. If a 0-10V dimmer is to be connected, install at this time. See Figure 2. Dimmer must be installed outside the shielded MRI environment with an intermediate MRI room EMI fi lter to the luminaires. Kenall recommends using a Leviton lllumatech IP710 series dimmer or Grafi k Eye GRX-TVI control interface. Contact Kenall for suitability of using an alternate sink-type 0-10V dimmer. WARNING: all DC power and dimming signal wiring must be run through separate EMI fi lters. 8. Run low voltage supply wires to luminaires using at least 18 AWG wires. Wire distances should not exceed 50 feet (15m) to prevent signifi cant line losses. Class 1 wiring is required. Make sure wiring is completely enclosed in grounded conduit. Any gaps, regardless of size, must be closed or wrapped in copper foil tape. Special attention should be paid to the wiring entry point into the shielded space. 9. Make connections to luminaires following the procedure in the luminaire installation instructions. NOTE: see Maximum Fixture Connection section for the maximum number of luminaires that can be connected to each power supply. 10. Complete any remaining steps on luminaire installation. 11. Connect power on line voltage side and test system operation. Test operation of lighting during MRI machine idle mode and during scanning operations. 12. Fill out the Installation Registration Form (attached) and fax to Kenall at (847) 360-1781. Multiple Power Supply Wiring Procedure Installations involving many luminaires may require multiple power supplies to handle the load. This section describes the procedure for properly wiring this situation. See Maximum Fixture Connection section for the maximum number of fi xtures that can be connected to each power supply. 13. Mount power supplies in the same manner as described in Section II. 14. Wire line voltage and low voltage connections similar to Section II, except follow the wiring diagram shown in Figure 3 to connect to each fi xture group. All DC Ground (black) leads must be tied together. WARNING: do not exceed the rated wattage of each power supply (312W). MRI room EMI fi lters are still required and must be sized to the load of the supply.

4 Maximum Fixture Connection Use the table below to determine the maximum number of luminaires that can be connected to an individual power supply. The maximum recommended DC amperage leaving the power supply should not exceed 13.0A. MRI LUMINAIRES CONNECTION PER POWER SUPPLY Amps Max. Luminaires per per Power Supply Luminaires Luminaire per room CSMRI22.35 28 CSMRI24 0.7 16 CSMRI44 1.4 8 MRIDL6 (13L) 0.8 13 MRIDL6 (23L) 1.2 8 MRIDL6 (31L) 1.7 6 MRIMAS813 (6W) 0.4 28 MRIMAS813 (14W) 0.7 16 MRIMAS826 1.0 10 MRIMAS838 1.3 8 MRIMAS850 1.7 6 MRIAUC 18 0.7 16 MRIAUC 36 1.4 8 ME11MRI 1.4 8 LPS5MRI-12 0.7 16 LPSR5MRI-12 0.7 16 CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY When installed to these instructions, this product is warranted by Kenall to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the external power supply carries a three year warranty from the date of invoice. The warranty is void if all power and dimming signal wiring is not completely shielded in grounded aluminum conduit and installed with a suitable MRI room fi lter (by others). Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notifi cation and confi rmation by its local representative of the defect. Kenall also reserves the right to test and examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, installed in applications for which it is not intended. This includes operation in ambient temperatures above stated limits for any length of time. Failure by electrical surge shall not be covered under warranty. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product. The foregoing warranty is exclusive of all other warranties and no other warranties of any kind are expressed or implied.