LOW PRESSURE CELERIS CONTROLLERS

Similar documents
LOW-PRESSURE SHUT-OFF CONTROLLERS

MEDIUM-PRESSURE SHUT-OFF CONTROLLERS

BASE UPGRADEABLE VALVES FOR TIERED SOLUTIONS

SLIM LINE FUME HOOD MONITOR

COMPACT CAGE RACK VALVES

TRACCEL BACNET CONTROLLERS

THERIS BACNET CONTROLLERS

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

THERIS LONMARK CONTROLLERS

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

ComfortPoint Programmable Lon, VAV/Unitary Controllers

TRACCEL LONMARK CONTROLLERS

X30 SERIES FUME HOOD MONITORS

Excel 15 W7760A BUILDING MANAGER

SASH SENSORS. part of the sensor bar, closing the magnetic switches it overlaps. The sensor bar changes resistance and a variable

Acid Resistant AVC6000

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Laboratory Room Controller

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

UHC-202 Hardware Guide

THERIS FAMILY OF VALVES

TRACCEL FAMILY OF VALVES LONMARK Certified

SENTRY FUME HOOD DISPLAY

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

LF Series Spring Return Direct Coupled Actuator

Spyder BACnet Programmable Controllers

Excel 10 W7751H3007 VAV ACTUATOR

CP-VL6436A, CP-VL6438N, CP-UL6438 ComfortPoint Programmable, VAV/Unitary Controllers

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

ACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES

Excel 10 W7751J Smart VAV Actuator

Installation/ Operation Maintenance. VariTrac Dampers

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

University of Delaware

Excel 10 W7751H SMART VAV ACTUATOR BEFORE INSTALLATION INSTALLATION

Healthcare Solutions Room Pressure Monitors and Controls

SAV Electronic Valve Actuator

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

SAX Electronic Valve Actuator

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Excel 10 W7751J Smart VAV Actuator

Laboratory Exhaust Air Terminal

Laboratory Room Single Duct Supply Air Terminal

Laboratory Solutions. pricecriticalcontrols.com

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Acid Resistant AVT6000

Installation and Operating Manual

MODEL RPM10/RPM20 (-LON)/RPM20-CC PRESSURA ROOM PRESSURE MONITOR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Digital/Analog Amplifiers Installation Instructions

GE Measurement & Control

Application Engineering

Application Engineering

MS Application. Features. Proportional Valve Actuator General Instructions

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Variable Air Volume Dampers

RETROFIT TERMINAL UNITS

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

VOC Duct and Rough Service Sensor

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Adaptive Power Module

Installation Instructions

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Non-Spring Return EconoDrive Floating Actuator

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

BUSWAY Low Voltage (Pow-R-Flex)

FAN POWERED TERMINAL UNITS

3 Phase Power Systems - Designed for Canada

Excel 10 W7751H Smart VAV Actuator

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

Condensed Version of Operator s Manual For The VI/VP700 Series Flowmeter and VI800 Series Flowmeter

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

SECTION WELDING FUME EXHAUST SYSTEM

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Laboratory Exhaust Systems

The Battery is a client module in the Cabinet Control. It is a backup/ups module which

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Adaptive Power Module

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Transcription:

LOW PRESSURE CELERIS CONTROLLERS Variable air volume (VAV) control schemes are commonly used for fume hoods, general exhaust, and room supply air. For typical fume hood applications, high-speed (< second speed of response) actuation is required. The Celeris valve controller interfaces with our current fume hood monitors for control and monitoring. Celeris controllers also provide room-level control functions in either standalone or integrated systems. For Tracking pair control (non-vav applications where make-up air control and an interface with the fume hood monitors are not required) Celeris controllers with lowspeed electric actuation offer an economical solution for room-level ventilation, pressurization, temperature and humidity control in either standalone or integrated systems. VAV fume hood controller VAV supply + S Two-state canopy (P) or (B) CV snorkel (C) + VAV supply booster VAV exhaust VAV supply + T FEATURES FEATURE/OPTION VAV (EXV/MAV) Control type L N M Actuator type Low-speed electric Pneumatic* High-speed electric Flow feedback signal Failsafe Last Position NO/NC NO/NC/Last Position Factory-insulated valve body (supply) Field-adjustable flow Flow alarm via feedback circuit Flow alarm via pressure switch Option Option Low noise diffuser construction All valves include pressure independent controller, factory-calibrated position controller. Phoenix Controls venturi valves are designed to reduce sound over all frequencies, but significantly target the lower bands (-00 Hz) to help eliminate the need for silencers. *The pneumatic actuator is not available for the -inch valve at this time. OSHPD Certified* This device is certified for OSHPD Seismic Certification Preapproval per 0 CBC, 0 IBC, ASCE -0, and IEC-ES-AC-. OSHPD Special Certification number OSP-090-0. *Vertical applications approval pending. NVLAP Accreditation All venturi valves are characterized on NVLAP Accredited Airstations, Lab Code 0099-0. NVLAP is administered by the National Institute of Standards and Technology (NIST). ISO Phoenix Controls Designs, Develops, Manufactures, and sells products, systems, and service to control the environment and airflow of critical spaces. Phoenix Controls is registered to ISO 900:00. Warranty Phoenix Controls Warrants all venturi valves against defects in material and workmanship for a period of years. In addition, all other equipment manufactured by Phoenix Controls, such as sash sensors, fume hood monitors, and equipment supplied but not manufacturered by Phoenix Controls is covered by a year warranty. TABLE OF CONTENTS Specifications... Ordering Guide... Typical Valve Controllers and Options... Points and Wiring... Transformers... Power Conductor Sizing... Discovery Way Acton, MA 00 USA Tel (9) 9- Fax (9) 9- www.phoenixcontrols.com 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0 MKT-0 MPC-

SPECIFICATIONS Construction ga. spun aluminum valve body with continuous welded seam Valve bodies available as uncoated aluminum or with corrosionresistant baked phenolic coatings Composite Teflon shaft bearings Spring grade stainless steel spring and polyester or PPS slider assembly Supply valves* insulated with /" (9. mm) flexible closed-cell polymer-based foam. Flame/smoke rating /0. Density is. lb/ft (.0 kg/m ) Operating Range - F (0-0 C) ambient 0-90% non-condensing RH Performance Pressure independent over a 0."-.0" WC (-0 Pa) drop across valve Volume control accurate to ±%, cfm of airflow command signal No additional straight duct runs needed before or after valve Available in flows from -00 cfm (0-9 m /hr) Response time to change in command signal: < second (control type M and N) < minute (control type L) Response time to change in duct static pressure: < second Pneumatic Actuation (Not available with the -inch valve) 0 psi (-0/+ psi) with a 0 micron filter main air required Compressor sizing: Phoenix Controls venturi valves are not continuous air-consuming devices. For compressor sizing, use: single and dual valves: 0 scim triple and quad valves: 0 scim Sound Designed for low sound power levels to meet or exceed ASHRAE noise guidelines. Power Vac (±%) @ 0/0 Hz Power Consumption Singles/Duals per valve Low-speed Electric: 0 VA High-speed Electric: 0 VA Pneumatic: 0 VA Notes:.All power consumption VA ratings listed here are based on fullyloaded I/O. I/O Available for connecting field devices: universal inputs. Accepts volt, ma, ohms or NTC or thermistor signals. digital input analog outputs. Provides volt or ma signals. digital output (Type C, amp @ Vac/Vdc) Input accuracy: Voltage, current, resistance: ±% full scale Output accuracy 0 to 0 Vdc: ±% full scale into 0 k minimum to 0 ma: ±% full scale into 00 +0/-0 Room-level Communications FTT-0, KB, bus topology, LonTalk network Building-level Communications TP-0,. MB, bus topology, LonTalk network Regulatory Compliance RoHS FCC This device complies with part of the FCC Rules. Operation is subject to the following two conditions:. This device may not cause harmful interference.. This device must accept any interference received, including interference that may cause undesired operation. EU Contact Address: Honeywell GmbH Boeblinger Str. 0 Schoenaich Germany * Not applicable to CVV series. Teflon is a registered trademark of DuPont Company. LonWorks is a registered trademark of Echelon Corporation. OF LOW PRESSURE CELERIS CONTROLLERS MKT-0 MPC- 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0

ORDERING GUIDE MAV A L - A M E H O - SFB REI VALVE FAMILY EXV = Celeris exhaust valve MAV = Celeris supply valve (comes standard with insulation) VALVE CONSTRUCTION A = Body and cone uncoated aluminum; uncoated stainless steel shaft B = Body and cone with baked-on phenolic coating; PFA-coated stainless steel shaft C = Body and cone with baked-on phenolic coating; hardware with titanium or baked-on epoxy phenolic coating; PFA-coated stainless steel shaft D = Body and cone with PVDF coating; hardware with PVDF or baked-on epoxy phenolic coating; PFA-coated stainless steel shaft; see Note NUMBER OF VALVE BODIES F = Single valve body with welded circular flange = One valve body no flange = Two valve bodies as one unit (dual); 0", ", and " valves only VALVE SIZE 0 = " valve (."/00 mm actual diameter) 0 = 0" valve (9."/ mm actual diameter) = " valve (."/0 mm actual diameter) = " valve (."/mm actual diameter) FLOW/PRESSURE OPERATING RANGE L = Low pressure operation; pressure independent over a range of 0. to.0" WC ( to 0 Pa), associated pressure switch trips at 0." WC See Standard Valve Flow/Pressure Operating Range table below VALVE OPTIONS EVI = Exhaust valve with insulation blocks and insulation IBO = Insulation blocks only, no insulation PSL = Pressure switch, low limit REI = Remote electronics; indoor applications only; see Note REO = Remote electronics; outdoor applications only, pneumatic actuation only; see Note WRE = Weather resistant electronics; outdoor applications, electric actuation; see Note SFB = Square flanges on both ends of single-body valves; see Note SFX = Single square flange mounted on either the exhaust inlet or supply discharge; see Note FAIL-SAFE POSITION C = Normally closed O = Normally opened Z = Fails to last position VALVE ORIENTATION H = Horizontal U = Vertical upflow D = Vertical downflow VALVE CONTROLLER DESIGNATION E = Electronic controller H = Hood exhaust valve with pressure switch; see Note CONTROL TYPE I = IP low-speed electric; only available on single-body valves in sizes 0, 0, L = Low-speed electric M = High-speed electric N = Pneumatic VALVE DESIGN A = Conical-shaped diffuser FLOW/PRESSURE OPERATING RANGE FOR STANDARD VALVE DESIGNS Designation L = Low Pressure Size 0" 0" " " Operating Range in CFM (m/hr) Single Dual -00 (0-) 0-0 00-00 (-90) (0-0) 90-00 0-00 (-0) (0-0) 00-00 00-00 (0-) (0-0) Pressure Drop Across Valve 0.-.0" WC (-0 Pa) NOTES:. Construction D is ONLY available in single-body valves (Number of Bodies = F or ) WITHOUT square flanges (Options SFB or SFX). Rectangular plates can be purchased as special products to field assemble two, three or four single-body round-flanged valves into multi-body configurations. For sizes 0, 0, and only.. Option REI: Remote Electronics, Indoor installations ONLY. The distance to the valve controller is limited to: - feet (. meters) of pneumatic tubing for pneumatic actuators (Control Type = N). - 0 inches ( meter) of gauge cable for high-speed electric actuators (Control Type = M). - 0 feet (. meters) of gauge cable for low-speed electric actuators (Control Type = L or I).. Option REO: Remote Electronics, Outdoor installations ONLY. Limited to PNEUMATICALLY actuated valves ONLY (Control Type = N). - HORIZONTAL orientation ONLY. - Includes: sealed Vpot, small weather-resistant NEMA R box mounted on base channel for others to connect Vpot cables, and a valve controller in an enclosure that has been disconnected from the base channel and shipped in the same box as the valve. - Maximum distance between remote mounted enclosure and valve is feet (. meters), the maximum allowable length of pneumatic tubing. - REQUIRES use of a dog house enclosure, provided by others, to protect valve from the elements and maintain temperature and humidity conditions within Phoenix s specifications.. Option WRE: Weather Resistant Electronics, outdoor installations. Applies to ELECTRICALLY actuated valves with sufficient IP ratings only - Control = I or M for single-body valves; Control = L or M for multi-body valves. - HORIZONTAL orientation ONLY. - Includes: sealed Vpot and large weather-resistant IP box mounted on base channel that houses the controller and all electric connections to/from it. - When used in Low-Speed Electric applications for 0", 0", and " single-body valves, WRE must ALSO be ordered with Control Type I (IP actuator) in place of the standard Control Type L. - When used in High-Speed Electric applications, standard actuators are sufficient (Control Type = E or M) since they are IP actuators. - REQUIRES use of a dog house enclosure, provided by others, to protect valve from the elements and maintain temperature and humidity conditions within Phoenix s specifications.. Celeris Hood valves cannot have Low Speed actuators (Control Type = L or I). 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0 MKT-0 MPC- LOW PRESSURE CELERIS CONTROLLERS OF

VALVE CONTROLLERS AND OPTIONS Valve Controller Designation Controller Type E Suitable for supply, make-up air, and general exhaust valve applications. Controller Type H Suitable for fume hood applications and includes a pressure switch for alarming. Valve Options (components added to enhance a valve s functions) Single square flange (SFX) Provides a single connection from a round single body valve to a square duct (on the inlet of single body exhaust valves; discharge of single body supply valves). typically used in Neutralizer TM applications. Two square flanges (SFB) Transitions each end of a single body valve from a round to square duct. Pressure switch (PSL) Detects low static pressure across the valve. Installed on non-hood exhaust valves to provide low static pressure alarm monitoring. POINTS AND WIRING NOTE: See submittal wiring diagram for project-specific details. Celeris Valve Controller UI TB TB NET A NET B Jumper Configuration for UI, and (S, S, S) Jumper Configuration for AO and AO UI S S V A R S- UI Voltage DI NO COM NC DO AO AO TB S- A V S S S TB R G B P.S. TB L L GND NOTES:. Power AWG (Controller Type M). High-speed electric valves must be connected in a star configuration.. Power AWG (Controller Type L).. Control signal AWG multi conductor, twisted pair. Communication AWG level ; AWG Belden (or equivalent). Each termination block (except TB, and ) uses a depluggable connector with screw-down terminations for ease of installation. TB CCW N CW TB B R Voltage Current Resistance/ Contact/ Thermistor Current TERMINAL BLOCKS CELERIS VALVE CONTROLLERS Terminal Block Typical Function Number of Terminations TB Input connections TB Output connections TB vpot and pressure switch TB Power ( Vac input) TB Actuator (control type L only) TB Communication (FTT-0) TB Actuator (control type M only) OF LOW PRESSURE CELERIS CONTROLLERS MKT-0 MPC- 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0

Typical Wiring Diagrams Hood Applications Tracking Pair Applications Hood Valve Vac c To Next Device Vac FTT-0 Channel c c From Previous Device MAV or EXV Tracking Valve TB TB TB TB TB TB TB TB I/O Connections for field devices as needed c VAV Fume Hood Monitor (FHM0/0) TB VacN TB TB VacH From AC Power Supply Red Black To TB- To TB- Vertical Sash Sensor Reel Sensor (See Note ) Zone Presence Sensor (ZPS00) TB Ground User Status Ground AMB Signal Sec In Vac Vac FTT-0 Channel c To Next Device c c From Previous Device TB TB TB TB TB TB Supply Valve TB TB Exhaust Valve c c c c I/O Connections for field devices as needed From space temp sensor From duct temp sensor DI to activate shut-off mode DO for confirmation c To reheat valve Network Wiring Room-level Network Echelon Corporation has tested and approved cables types for use with the FTT0 communications transceiver. Based on availability, cost and maximum distance limitations, we have focused our recommendation to two cable types: Generic NEMA level cable, AWG (0. mm)* Belden, AWG (. mm) cable (or equivalent) NOTE: Level cable specified by Echelon as originally defined by the NEMA differs from the Category specification proposed by the Electronic Industries Association/Telecommunication Industry Association (EIA/TIA). The cables Phoenix Controls recommends are stranded, two-conductor, twisted-pair (TP) without a shield. A shield, or drain wire, is not required for Celeris communications wiring and should not be used. Both of these cables are available from multiple sources either solid or stranded, in plenum and non-plenum rated versions. If two conductors are to be placed in a terminal opening, twist the bare conductors prior to inserting these in the terminal opening. If a wall-mounted sensor with a communications jack is used, the connections to the jack must be treated as either a bus connection or an EOL connection. While the room-level communications wiring is not polarity sensitive, it is recommended that a consistent color-coding and polarity convention be followed. Each terminal on the terminal block will accommodate up to two AWG (. mm) stranded conductors. Communications connections are to be made following a bus or daisy chain topology. Two end-of-line (EOL) terminators must be installed, one at each end of the room-level network. Maximum Cable Lengths When using Level cable operating in a bus topology, the maximum cable length is 00 feet (0 meters). When using AWG cable operating in a bus topology, the maximum cable length is 00 feet (0 meters). 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0 MKT-0 MPC- LOW PRESSURE CELERIS CONTROLLERS OF

Phoenix Controls Wiring Recommendations Use cables recommended by Phoenix Controls. Stranded wire is strongly recommended for ease of installation. Follow good wiring practices: Do not run the communications cable in the same conduit or wire way as the power cables. If the communications cables must cross power cables, it is best to do so at a 90-degree angle. Shield or drain wires, if present, should be wrapped with insulating tape to prevent contact with exposed conductors or contacts. Maintain a consistent color code or polarity all the way through the wiring system. All connections must meet the requirements of an NEC Class circuit. Local and national electrical codes take precedence. Consult the project specific wiring diagrams for exact details. TRANSFORMERS The Celeris valve controller requires the use of a step-down transformer (either 0/ volt or 0/ volt). Any transformer used to power Celeris valve controllers must meet the requirements of an NEC Class circuit. The secondary transformer must be limited to a maximum of 0 Vac. Secondary power shall be current limited with either internal circuit breaker protection or with a four-amps slow-blow fuse, in accordance with NEC Class power requirements. Phoenix Controls offers the following recommendations; however, designers, installers and owners should always consult their national and local electrical codes before selecting transformers for their systems. Transformers should not exceed 00 VA. Use multiple transformers, rather than larger transformers, when more than 00 VA is required. Each pressurization zone should have either a dedicated single-phase primary circuit or a secondary circuit disconnect. If an earth ground is provided, it should not be connected to the Celeris valve controller, even though there is a threeterminal connector on the controller board. NOTE: AC line voltage polarity must be maintained on all Celeris valve controllers and AC powered ancillary devices. Transformer Sizing To size a transformer, all of the VA loads for the circuit must be totaled. This table outlines the power ratings of Celeris products and related outside purchased equipment. Use these values to size the power transformers for the Celeris system. Celeris Valve Controller Control type L (low-speed electric) Single/dual valve body 0 VA Control type M (high-speed electric) Single/dual valve body 0 VA Control type N (pneumatic) Single/dual valve body 0 VA External Devices Router/repeater modules VA Sensor Approved thermistor 0 VA Heating valve Belimo LM (-state) VA Heating valve Belimo LMSR (propor) VA Each -0 ma device Example: transducers 0. VA OF LOW PRESSURE CELERIS CONTROLLERS MKT-0 MPC- 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0

Power Conductor Sizing Low-Speed Electric and Pneumatic Valves Can be powered in a BUS configuration For loads up to 9 VA, use AWG cable with a maximum length of 0 feet ( meters) between the transformer and the last daisy-chained device High-Speed Electric Valves in a HOME-RUN Configuration MUST be powered in a HOME-RUN configuration For loads up to 9 VA, use a dedicated AWG cable with a maximum length of 0 feet ( meters) home-run between the transformer and the valve No other valves can be daisy-chained from this power Bus power configurations are NOT allowed between high-speed valves MAINTENANCE Celeris valves require no ongoing maintenance. Once the field engineer has completed the field startup, the valves will provide years of continuous operation. 999 Phoenix Controls. Specifications subject to change without notice. Rev. 0/0 MKT-0 MPC- LOW PRESSURE CELERIS CONTROLLERS OF