RZVA. Vacuum Circuit Breakers Type BPC-110. Technical Information НКАИ ТИ

Similar documents
TRANSFORMER SUBSTATIONS PRODUCT CATALOGUE

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

AF series contactors (9 2650)

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

3TM Vacuum Contactors

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

7 Switching Equipment and Control Devices

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

NXPLUS C Single busbar. Maintenance-free for lifetime

AF series contactors (9 2650)

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

HD4. Gas insulated MV circuit-breakers kv A ka

Product Specification

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Publication No.: PSG

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Extensible Unit - VCE2a

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Solid Dielectric, Three Phase Reclosers CATALOG VS11

kv А

Metal Clad Air Insulated Switchgear

Instruction for Installation and Operation

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Outdoor vacuum breaker for railway applications - FSK II

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Live Tank Circuit Breakers Buyer s Guide

01 Spectra Plus - Introduction

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

FUSES PN22 SERIES Technical description and user manual

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

045 : 2000 CEB STANDARD

8DJ. Maintenance-free for lifetime

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

AUTOMATIC STANDBY ACTIVATION. Operation Manual

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

شركة كهرباء محافظة القدس المساهمة المحدودة

Medium Voltage Metal-Enclosed Switches

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Medium Voltage Metal-Enclosed Switches

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Benefits, typical uses

Medium voltage vacuum circuit breaker. E-VAC series

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

ZX-Family Gas-insulated medium voltage switchgear

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

EMPAC Metal enclosed capacitor bank for wind applications

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

MEDIUM VOLTAGE SWITCHGEAR

SAFETY FUSES PP57U SERIES Technical description and user manual

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Solid Dielectric, Single Phase Recloser

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

B kv T&D GAS INSULATED SWITCHGEAR

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

132/11 kv, 25 MVA MOBILE SUBSTATION

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

OHB Outdoor sulphur Hexafluoride circuit-breaker

Domae. The right solution for distribution boards

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

123/145kV SF6 Gas-Insulated Switchgear incorporating VCB. 145kV-1250~2000A-31.5kA

vertical fuse switch disconnectors

Industrial Contactors CTX 3 3P 185A - 800A

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Independent Testing Laboratory for High Voltage Equipment

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Air-insulated switchgear UniGear type ZS1

36kV Gas Insulated Medium Voltage Switchgear

CPG.0 Single busbar gas-insulated cubicles

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Transcription:

RZVA Vacuum Circuit Breakers Type BPC-0 Technical Information НКАИ.670049.04 ТИ Edition 7 04

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ CONTENTS Page Introduction 3 General Information 3 Conventional Symbols Representing Circuit Breakers 4 3 Main Technical Parameters 5 4 Composition and Operation 9 5 Completeness of Delivery 0 6 Ordering the Circuit Breakers Supplement A Overall, Installation and Fitting Dimensions of BPC-0 Vacuum Circuit Breakers Supplement B Electrical Diagram 4 of BPC-0 Vacuum Circuit Breakers Supplement C. Configuration Data Sheet for Ordering Circuit Breakers (how to fill) 5 Supplement C. Configuration Data Sheet for Ordering Circuit Breakers 6

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Introduction The following technical information is provided for the professionals of instates, engineering and operating companies which deal with developing and modernisation of packaged transformer substations and units of factory-assembled switchgears of railway substations. We have deliberately avoided the framework of typical catalogues and have provided a wider range of technical characteristics and peculiarities of circuit breakers. General Information BPC-0 vacuum circuit breakers for outdoor installation are the first single break vacuum circuit breakers. The poles have solid-cast silicone insulation. Circuit breakers are produced with spring actuator. The following circuit breakers meet the requirements of GOST P 5565-006 and technical specifications ТУ 344-0-95799595-00. BPC-0 circuit breakers are used for switching of electric high-voltage circuits under normal and emergency modes in three-phase alternating current networks with rated voltage of 0 kv and the frequency of 50 Hz with grounded neutral and earth fault quotient of,4. BPC-0 circuit breakers are used as components for 0 kv open switchgears of packaged transformer substations КТПБР-0/35/0(6). Circuit breakers have earthquake resistant design and can be operated at an altitude of 0, m with ductility level event (DLE) of 9 points according to MSK-64 scale. Due to a number of their advantages BPC-0 circuit breakers can also be used for the enhancement of current substations or the replacement of obsolete air circuit breakers. Main advantages are: - minimum level of maintenance; - minimum amount of installation works because circuit breakers are delivered completely assembled and adjusted. The customer only has to install the supports and to add the actuator (without adjusting); - mechanical durability is up to 0000 cycles BO ( O opening operation, B closing operation); - commutation durability is 5 O ( Open ) operations at rated breaking current; - commutation durability is 0000 cycles BO at rated current ( O opening operation, B closing operation); - solid-cast silicone insulation of the poles as compared to ceramic cover reduces weight and dimensions of the circuit breaker and significantly increases the reliability of insulation; - warranty period is years commencing from the day of putting into operation. Besides, the design of BPC-0 circuit breakers provides: - lateral position of spring actuator of the circuit breakers which provides good access to the spring actuator; - possibility of operation within wide range of temperatures from -60 C to +50 C; According to electrical diagram of the actuator, external connections of secondary circuits and the amounts of current consumption BPC-0 circuit breakers are compatible with previously installed circuit breakers in the substations. 3

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Conventional Symbols Representing Circuit Breakers ВРС 0 III / УХЛ climatic design and placement category according to GOST 550-69 and GOST 5543.-89 rated current, A rated breaking current of the circuit breaker, ka level of insulation pollution according to GOST 990-89 rated voltage, kv trade mark BPC (vacuum circuit breaker for outdoor installation with spring actuator) The following conventional symbols represent BPC-0 circuit breakers with spring actuator for rated voltage of 0 kv with level III of insulation pollution, rated breaking current of 3,5 ka, rated current of 500 A with УХЛ climatic design and placement category: BPC-0 III-3,5/500 УХЛ ТУ 344-0-95799595-00. Main Technical Parameters The following are the rated values of climatic factors for circuit breakers according to GOST 5543.-89 and GOST 550-69: a) altitude above sea level not exceeding 000 m; b) upper working value and effective value of air temperature surrounding the circuit breaker is +50 C and +40 C; c) lower working value of air temperature surrounding the circuit breaker is -60 C; d) standard slick thickness is 5 mm at an altitude of 0 m above ground level with recurrence interval of once in 5 years; e) standard wind load is 80 kgf/m (800 H/m ) under the conditions of ice slick at an altitude of 0 m above ground level with recurrence interval of once in 5 years; As far as earthquake resistance is concerned the circuit breakers can be operated at an altitude of 0, m with ductility level event (DLE) of 9 points according to MSK-64 scale according to GOST 756.-90. 4

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Electric strength of insulation of the circuit breaker meets the requirements of GOST 56.3-96 for the devices with voltage of 0 kv and with standard insulation. External insulation under the conditions of pollution meets the requirements of level III of insulation pollution according to GOST 990-89. The circuit breakers work in operations O and B and in cycles O-0,3sec-BO-80sec-BO, O-0,3sec-BO-0sec-BO and O-80sec-BO-80sec-BO ( O opening operation, B closing operation). The circuit breakers belong to the class C according to ГОСТ Р 5565-006. Circuit breakers are capable make and breake in this circuit the no-load currents of overhead lines up to the rated values of the breaking currents of unloaded overhead lines specified in Table of this technical information, with a low probability of restrike. Main technical parameters of BPC-0 circuit breakers are shown in Table. Table Parameter Requirements for the modification BPC-0 III-3,5/500 УХЛ BPC-0 III-40/350 УХЛ Rated voltage, kv 0 Maximum operating voltage, kv 6 3 Rated current at frequency of 50Hz, A 500 350 4 Rated breaking current, ka 3,5 40 5 Standard parameters of making current, ka: a) initial active value of periodic component b) maximum peak 3,5 8 6 Standard parameters of short-circuit steady leakage current, ka: a) maximum peak (electrodynamic endurance 8 current) b) root-mean-square value of the current during its flowing (thermal endurance current for the period of 3,5 3 sec) c) initial active value of periodic component 3,5 7 Standard breaking current of unloaded overhead line, A, not exceeding 3,5 40 0 0 40 40 5

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Table continued Requirements for the modification Parameter BPC-0 III-3,5/500 УХЛ BPC-0 III-40/350 УХЛ 8 Standard percentage of aperiodic component, %, 40 not exceeding 9 Intrinsic turn-on time, msec, not exceeding 80 0 Intrinsic turn-off time, msec, not exceeding 3 Total turn-off time, msec, not exceeding 47 Dead time of auto reclose, sec, not less than 0,3 3 Test voltage of internal and external insulation of 450 full lightning impulse, kv 4 Test short-term voltage of internal and external insulation in dry condition with partial discharge 00 absence check, kv 5 Test short-term alternating voltage of internal and 00 external insulation in the rain, kv 6 Absolute pressure of gas flushing (N) at the 5 temperature of 0 C of internal insulation plates of the circuit breaker, kpa 7 Absolute pressure of alarm actuation of gas 00 pressure reduction (N) at the temperature of 0 C of internal insulation plates of the circuit breaker, kpa 8 Gas weight (N) at the temperature of 0 C of 0,7 internal insulation plates of the circuit breaker, kg 9 Potential annual gas leak (N), %, not exceeding 0, 0 Volume ratio of water vapour in nitrogen, %, not 0,004 exceeding Mechanical durability, number of cycles BO 0000 ( O opening operation, B closing operation) Commutation durability: - at rated current, number of cycles BO - at rated breaking current, number of operations O 0000 5 ( O opening operation, B closing operation) 3 Weight of the circuit breaker, kg 645 700 6

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Main parameters of the secondary circuits of BPC-0 circuit breakers are shown in Table. Table Parameter Requirement Rated voltage of the circuit of closing spring charging motor (M) of the actuator: - at direct current, V 0; 0 - at alternating current, V 30; 0 Operating voltage range of the circuit of closing spring charging motor (M) of the actuator in percentage to rated voltage at direct or alternating 85-0 current 3 Current consumption of the circuit of closing spring charging motor (M) of the actuator measured at the moment of maximum shaft load: - at direct voltage of 0 V and alternating voltage of 30 V, A, not 4,6 exceeding; - at direct voltage of 0 V and alternating voltage of 0 V, A, not 9, exceeding 4 Initial starting current of the circuit of closing spring charging motor (M) of the actuator: - at direct voltage of 0 V and alternating voltage of 30 V, A, not 30 exceeding; - at direct voltage of 0 V and alternating voltage of 0 V, A, not 60 exceeding 5 Time of the circuit of closing spring charging motor per one closing 5 operation at minimum voltage, sec, not exceeding 6 Rated voltage of the circuit of closing electromagnet (YAC) at direct current, V 0; 0 7 Rated voltage of the circuit of tripping electromagnet (YAT) at direct current, V 0; 0 8 Rated voltage of circuit of independent power tripping electromagnet (YAV) at direct current, V 0; 0 9 Operating voltage range of the circuits of control electromagnets at direct current in percentage to rated voltage: - YAC - YAT and YAV 0 Current consumption of control electromagnets (YAC, YAT, YAV): - at direct voltage of 0 V, A, not exceeding; - at direct voltage of 0 V, A, not exceeding; Heating capacity of the actuator box at alternating voltage of 30 V, kw 80-0 70-0,5 3,0 0,5 7

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Interlock contacts of circuit breaker position are installed in the actuator box of the circuit breaker. Technical parameters of interlock contacts are shown in Table 3. Table 3 Parameter Requirement Rated voltage, V 0 Test voltage, kv,0 Thermal endurance current for the period of sec., A 0 According to electrical diagram interlock contacts of circuit breakers have 6 normally closed contacts and 6 normally opened contacts. Overall, installation and fitting dimensions of circuit breakers are shown in supplement A. Electrical diagram of circuit breakers is shown in supplement B. Note: Subject to previous agreement, circuit breakers can be produced according to customer s climatic, mechanical and electrical requirements which may differ from those indicated in the following chapter. 4 Construction and principles of operation Circuit breaker BPC-0 type consists of the following basic parts: unit pole, box with the spring actuator and bearing metal constructions (bars). Unit pole consist of: - three poles with vacuum chambers, made with a unit-cast silicone insulation and filled with nitrogen; - frames, with poles installed on it, adjustable tractions and conditional nitrogen pressure indicator installed in it; Pole of circuit breaker type BPC-0 consist of vacuum arc-quenching chamber (VBC), bearing envelope, insulation traction, upper and lower contacts, champs and components of compression for the pole sealing. Upper and lower pole parts are made of glass-plastic pipe, covered outside with silicone insulation. For ensuring the insulation strength inside of the pole: space between upper envelope and vacuum chamber is filled with polymeric insulation, inner surface of lower envelope covered with silicone insulation. Insulation pole traction is covered with silicone insulation as well. Current traction insulation is accomplished with ribbing in order to augment leakage path. To prevent dampness occurrence and influence, inner pole hollows are filled with nitrogen with absolute pressure of 5 kpa at 0 C. Current pole hollows are connected with communicating pipes. And nitrogen pumping is performed through the clapper, installed on the one last pole, and conditional pressure indicator is installed on the other last pole. Conditional nitrogen pressure indicator (SP) has temperature compensating mechanism and control nitrogen density point in all circuit breaker s temperature range. It always at every temperature range of the circuit breaker displays the excess of nitrogen pressure 0,05 MPa on default (indicators scale in the green sector 0,5 Bar), which corresponds to the absolute pressure of the nitrogen load in the amount of 5 kpa at temperature 0 C. In case if the absolute nitrogen pressure reduces to 00 kpa at 0 C, the indicator of the nitrogen pressure on default the normally open signalizing contact will close, the 8

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ point on the indicators scale will be in the red sector 0,6 0 Bar, which indicates on the necessity for execution of the additional nitrogen loading of the poles. The spring actuator of the circuit breaker type BPC-0 is installed in the actuator s box and kinematically connected through tractions with circuit breaker s poles. The controlling by circuit breaker s activator is performed through the chain of the electro engine (M) with starting of the closing spring and through the controlling chain and protections, exactly through electromagnet s tripping chain (YIT), through the closing electromagnet chain (YAC) and through the tripping electromagnet s chain which disconnects from the independent power supply (YAV). All chains of controlling, protection and heating of the actuator are lead out to the clamp row XT, which is installed in the actuator s box. Two slugs are installed for connection to the external secondary chains on the bottom of the actuator s box, through which two lead wires can be installed for connecting clamp row XT. Turning off of the circuit breaker is performed due to energy of the closing actuator s spring. Starting of the actuator s closing spring can be performed automatically with the help of electro engine (M) or manually with lever for starting of the closing spring. After the starting of the closing spring, the operation B can be performed, which is executed by voltage supply in the electro magnet s closing chain (YAC) or by pushing the button On. After the execution of the operation B the automatic starting of the closing spring will be performed for possibility of executing of Automatic power supply of circuit breaker. The circuit breaker in the working position can be turned off by power supply in the closing electro magnets chain (YAT), closing electro magnets chain from independent power supply (YAV) or with the help of button Off. Turning off is executed due to the energy of spring constriction mechanisms of the poles and closing spring which are started during the turning on of the circuit breaker. In the control scheme of circuit breaker type (BPC-0) there is the blocking relay against the repeated turning on (KBS). The switch SACY which is installed in the actuator s box and designed for the selection of circuit breakers mode of control. The switch has two fixed positions: local, distant. The control of the circuit breaker is turned off in the neutral position (commands are not active), and only the contact of signalization, which indicates this position, is closed. In the actuator s box also the switch SA is installed for giving of commands ON and OFF designed for the local control. The switch is with self-back function in the neutral position. 5 The complete set of delivery The complete basic delivery set for the circuit breakers BPC-0 execution includes: - pole unit, piece.... - box with spring actuator, unit... - bar HKAИ.304.73, unit.. - bar HKAИ.304.73-0, unit... - grounding bus HKAИ.68564.03, unit..4 - protecting screen HKAИ.304.69 with fixing elements, unit. 9

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ - lever designed for starting of actuator s closing spring, unit... - list of manual usage documents of electric circuit breaker, copy... - complete set of the manual usage documents with the list of electric circuit breaker (registration certificate passport, operating manual list of spare parts and equipment, etc.), set..... - complete set of spare parts, instruments and equipment in accordance with a list of single list of spare parts and equipment, set........ - the complete set of spare parts, instruments and equipment in accordance with a list of repairing spare parts and equipment, set...... Attention:* delivered in accordance with separate order and payment. 6 ORDERING OF CIRCUIT BREAKERS During the ordering of circuit breakers (look supplement С), besides the structure of indication of the type execution of the circuit breakers and Technical Conditions current type, voltage in volts frequency have to be indicated additionally: a) chains of the electro engine (M) of actuator s closing spring starting b) closing electromagnet s chains (YAT); c) closing electromagnet s chains (YAC); d) closing electromagnet s chain design for disconnecting from the independent power supply (YAV). Besides the aforementioned, it is necessary to indicate the usage sphere of circuit breaker: in case of replacement it is necessary to indicate the type of the replaced circuit breaker and in case of fundamental building indicate the usage of basic execution. In case of absence of the additional indications in the order, circuit breaker type BPC-0 is produced with the electro engine chain (M) of starting of the closing actuator s spring, closing electromagnet s chains (YAT) and closing electromagnet (YAC), chains of closing electromagnet designed for disconnection from independent power supply (YAV) for direct current voltage 0 volts with scheme of the electrical connections in accordance with supplement B and to support bar and protecting screen in accordance with Figure A. Contact information Limited Liability Company Highvoltage union RZVA Bielaya St., 6, City of Rivne 3300, Ukraine Telephone: (+38 036)6-7-94 Fax: (+38 036)6-7-0 0

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Supplement À 56 453 43 500± 500± 394 30 À 60 6 hole Ç8 0 60 À 30 0 055 60 0 45 Protection screen 0 400 3640 4 480 4 hole Ç4 7,5 B 45 36 4 64 75 476 580 500 400± 400± 4 grooves 380 500 490 B 00 530± bar 400 Figure A. - Overall, adjusting and adjoint dimensions of the vacuum circuit breakers tupe BPC-0 III-3,5/500 ÓÕË

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Continue of the supplement À 56 453 43 500± 500± 394 À 60 30 6 hole Ç8 0 60 À 30 0 60 0 45 055 Protection screen 0 400 3640 4 480 4 hole Ç4 7,5 B 45 36 4 64 75 476 580 500 400± 400± 4 grooves 380 500 490 530± bar 400 00 B Figure A. - Overall, adjusting and adjoint dimensions of the vacuum circuit breakers tupe BPC-0 III-40/350 ÓÕË

500± 500± Continue of the supplement À Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ 400 879 440 30 70 3905 5066 4 0 0 530± 63 Polling (bars) 545 700 800 850 Figure A.3 - Overall, adjusting and adjoint dimensions of the vacuum circuit breakers tupe BPC-0 (for replacement of circuit breakers BMT-0) 3

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ XÒ78 XÒ76 XÒ73 XÒ84 XÒ96 3 SA -45 0Å +45 SACY Î Â Ì Ä SA -45 0Å +45 Î Â 4 4 SACY Ì Ä SF 3 KM 3 4 KBS 5 KBS 3 4 8 7 3 5 6 M M 4 3 0 9 3 4 7 8 Supplement B A YAC KBS PC A YAT XÒ93 5 6 38 37 A A SK 9 30 34 33 68 67 A A KM SM SK XÒ75 4 3 95 96 A A XÒ5 XÒ97 XÒ60 XÒ/ XÒ77 XÒ85 SF0 SF XÒ53 XÒ54 XÒ/ XÒ/3 XÒ/4 XÒ45 XÒ55 XÒ50 6 6 EK 0 SP KL A A 7 5 4 XÒ05 BK X0 KL EK KL3 9 A A 7 5 4 BK KL 3 4 KM 9 30 SK 3 4 SK 6 5 KM XÒ46 XÒ49 SF 3 4 6 5 XÒ58 XÒ57 III II YAV KM SA HLR HLG XÒ59 I XÒ/6 SM 5 6 Heating XÒ94 XÒ5 XÒ98 XÒ80 XÒ79 XÒ83 XÒ8 XÒ8 XÒ8 Closing electromagnet Blocking relay against the repeated turning on Ñounter Tripping electromagnet Tripping electromagnet from the independent power supply Contactor of the engine control VCB is ON VCB is OFF Motor of the spring starting Siglization of the gas pressure in circuit breaker's poles Plug XÒ9 XÒ89 XÒ4 XÒ XÒ69 XÒ87 XÒ68 XÒ7 XÒ67 6 8 Ì SACY Ä 5 6 SF SM SK 97 98 SF0 KM 43 44 5 XÒ9 7 XÒ3 "Distant" "Local" XÒ5 XÒ3 XÒ9 XÒ88 XÒ30 XÒ3 XÒ6 Indication YAT KBS YAV Description Tripping electromagnet Relay KBS Tripping electromagnet from the independent power supply Blocking contacts of the actuators position SM, SM (signalization of the spring starting M, Motor Blocking contacts of the circuit breakers positions HLR ON indicator EK,EK,EK Heater SF, SF0, SF Àutomatic YAC Closing electromagnet PC Ñounter KM, KM Contactor KL, KL3 Intermediate relay SA, SACY Switch HLG OFF indicator SP Contact of monostat SK Thermal release BK, BK Temperature indicator X0 Socket XT Connecting clamps XT Connecting clamps VCB is ON VCB is OFF Power supply of the motor of the spring starter Spring is charget Motor overload Heating Running the motor Signalization of the switch position SACY Number 3 3 46 7 XÒ35 XÒ4 XÒ47 XÒ37 XÒ39 XÒ6 XÒ9 XÒ00 XÒ0 XÒ7 XÒ XÒ XÒ5 XÒ9 XÒ3. The position of the scheme elements corresponds to the circuit breakers position "Turnet off", drive is discharged.. Contact SP of monostat is opened while working gas pressure of gas in poles. XÒ XÒ3 XÒ7 7 5 8 6 5 6 9 0 3 4 7 8 9 3 7 3 35 39 5 0 4 8 3 36 40 6 33 34 37 38 Figure B - Electrical principal scheme of the circuit breakers type BPC-0 XÒ36 XÒ4 XÒ48 XÒ38 XÒ40 XÒ44 XÒ0 XÒ0 XÒ03 XÒ8 XÒ43 XÒ XÒ6 XÒ0 XÒ4 XÒ XÒ4 XÒ8 XÒ/5 KL3 EK KL3 3 4 XÒ/7 4

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Supplement С. How to fill Interrogatory list Of the order of the vacuum circuit breakers type BPC-0 IS FILLED BY THE CUSTOMER Customer LLC Promet Object name p/c Horenichi Circuit breaker technical data 3 Characteristics Rated voltage кв 0 4 of the main Closing rated voltage ка 3,5 5 chains Rated voltage А 500 6 Climatic execution and the category of placement according to GOST 550 УХЛ УХЛ 7 Characteristics Current type and chain rated voltage of the electro engine (M) of В of the starting closing actuator s spring = 0 8 secondary Current type and chain rated voltage of the closing electromagnet В chains (YAC) = 0 9 Current type and chain rated voltage of the electromagnet (YAC) В = 0 0 Current type and chain rated voltage of the closing electromagnet with В independent power supply (YAV) = 0 The sphere of - for a circuit breaker change:вмт-0 - ; ВГТ-0 - ; LTB - ; -. usage - for the fundamental building (basic execution of the circuit breaker BPC0 ) Х. Order of the necessary equipment Number of the ordered circuit breaker s of one type = N 5 3 Structural (on default) indication of the circuit breaker in accordance with technical maintenance (or technical instruction) BPC-0 III-3,5 / 500 УХЛ Full name and position of the person responsible for the order Chief engineer of p/c Horenichi Contact telephones, fax +38 064 433840 Date and signature 7.07.0 Note: For circuit breaker s with different parameters and sphere of usage fill in the separate interrogatory lists FILLED IN BY THE MANUFACTURING ENTERPRISE Specification for the order executing 4 Breaker s code Number 5 5 Structural (on default) indication BPC-0 III-3, 5/500 УХЛ 6 Circuit breaker Indication of the drawing on НКАИ.67453.0 default 7 Principal electrci scheme НКАИ.67009.39 ЭЗ Equipment concerning the order Name Indication Number * for the basic execution. The 8 Set of parts of the documentation set must include НКАИ.67453.0 Д* Montagnais the installment drawing 9 НКАИ.67453.0 МЧ 0 3 4 Specification is concluded by: Date and signature: 5

Edition 7 НКАИ.4-04 НКАИ.670049.04 ТИ Supplement С. Interrogatory list Of the order of the vacuum circuit breakers type BPC-0 Customer Object name IS FILLED BY THE CUSTOMER Circuit breaker technical data 3 Characteristics Rated voltage кв 4 of the main Closing rated voltage ка 5 chains Rated voltage А 6 Climatic execution and the category of placement according to GOST 550 УХЛ 7 Characteristics Current type and chain rated voltage of the electro engine (M) of В 8 of the secondary starting closing actuator s spring Current type and chain rated voltage of the closing electromagnet В chains (YAC) 9 Current type and chain rated voltage of the electromagnet (YAC) В 0 Current type and chain rated voltage of the closing electromagnet with independent power supply (YAV) В The sphere of - for a circuit breaker change:вмт-0 ; ВГТ-0 ; LTB ;. usage - for the fundamental building (basic execution of the circuit breaker BPC0 ). Order of the necessary equipment Number of the ordered circuit breaker s of one type = N 3 Structural (on default) indication of the circuit breaker in accordance with technical maintenance (or technical instruction) Full name and position of the person responsible for the order Contact telephones, fax Date and signature Note: For circuit breaker s with different parameters and sphere of usage fill in the separate interrogatory lists FILLED IN BY THE MANUFACTURING ENTERPRISE Specification for the order executing 4 Breaker s code Number 5 Structural (on default) indication 6 Circuit breaker Indication of the drawing on default 7 Principal electrci scheme Equipment concerning the order Name Indication Number 8 9 0 3 4 Specification is concluded by: Date and signature: 6