유량계전문제조업체. Electro Magnetic FLOWMETER

Similar documents
E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

SITRANS F M flow sensors 711/A and 711/911E

Magnetic Inductive Flowmeter EP / UMF2 (B)

ISTEC MAGNETIC METERS

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Electromagnetic Flowmeters. Product Overview.

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Electromagnetic Flow Meter Owner s Manual HARDWARE

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Electromagnetic amplifier Primo Advanced for all detectors

Magnetic-inductive flow meter for hazardous areas

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Electromagnetic amplifier type ModMAG M10 for all detectors

F6700 ELECTROMAGNETIC METER

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Options guide. Electromagnetic flowmeters. M9xx

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-ENG

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Electromagnetic flowmeter EMKO E

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

SHENITECH, LLC

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-6-ENG

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

PROCESSAUTOMATIC MAGNETIC FLOWMETER

ProcessAutomatic EZ-Mag

Electro-Magnetic Flowmeters Sensors MagMaster MFE

FLOWX3 F3.60M.S Insertion Magmeter

SENSOR MUT2400EL. Electromagnetic flowmeter. The electromagnetic flowmeter designed for food industry DS200-1-ENG

Field IT Electro-Magnetic Flowmeters Sensors

Full Profile Insertion

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

UniMag DT Series Electromagnetic Flow Tubes

Armstrong In-Line and Insertion Vortex Flow Meters

Detector (for water measurement applications)

Electromagnetic flowmeters

VLM20 In-line Vortex Flowmeter

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

Differential Pressure Gauges (701P Series)

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Electromagnetic flowmeters for water and seewage

Botlek Studiegroep Basics Electro Magnetic Flowmeters

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Metal tube variable area flowmeter for gases, liquids and steam

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Multivariable Vortex Flow Meter

General Specifications

STEEMCO Flowmeter for Steam

Rosemount 8750WB Magnetic Flowmeter System

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

HENRI Flowmeter for Pulp Slurry

CM2-MGG User s Manual

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

F-2600 SERIES INLINE VORTEX FLOW METER

Multivariable Vortex Flow Meter

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

OPTIFLUX 6000 Technical Datasheet

MagFlux Q 8200 Series

Magnetic-Inductive flow Meter fmi

KTLDE Intelligent Electromagnetic Flowmeter

Electromagnetic Flow Monitor magphant

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Positive Displacement Flowmeters

The readings you need, right where you need them. AX Series Vortex Meters

Plastic tube variable area flowmeter for liquids and gases

SRT1000 Series THERMAL FLOWMETER

Vortex Flow Meter Model DVH

Technical Information Proline Promag 10L

Magnetic-Inductive Flow Meter FMI

ORIMAS Mass Flowmeter

Design and application

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

Electromagnetic Flow Monitor magphant

AquaMaster4 Electromagnetic flowmeter flanged sensor

The readings you need, right where you need them. AX Series Vortex Meters

Insertion magnetic inductive flowmeter

Appendix. Clearance. Skewed profiles. Application Schematics

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Vortex Flowmeter Model DVE

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Time Delta S Fixed Transit-Time Flow Meter System

Magnetic-Inductive Flow Meter FMQ

RCM - Direct Reading Flowmeters

Magnetic Inductive Flow

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Quick Start Guide. Tek-Flux 1400A. 796 Tek Drive, Crystal Lake, IL USA

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Transcription:

유량계전문제조업체 w w w. f c k o r e a i n s. c o m Electro Magnetic FLOWMETER

ELECTRO-MAGNETIC FLOW METER Contents Principle of Operation 04 Grounding Method 05~07 Piping Installation 08 CN-400 CNT-2 Flanged Combined Type Battery Type Flanged Separate Type 09 ~ 17 19 ~ 22 23 ~ 29 CNW-1 / CNW-2 Wafer Type 31 ~ 44 Appendix Easy Manual for Converter 45 ~ 47 Flange Dimension 49 ~ 53

1. Principle of Electromagnetic Flowmeter 1-1. Principle of Operation The electromagnetic flowmeters are the ideal flowmeters for metering the flow of all liquids, slurries and sludges that have a specific minimum electrical conductivity. These flowmeters measure accurately, create no additional pressure drop, contain no moving or protruding parts, are wear free and corrosion resistant. Installations are possible in any existing piping system. The electromagnetic flowmeter has proven itself over many decades and is the preferred flowmeter in the Chemical, Pharmaceutical and Cosmetic industries, Municipal Water and Waste Water treatment facilities and in the Food and Paper industries. 1-2. Measurement Principle Faraday s Laws of induction form the basis form the basis for the electromagnetic flowmeter which states that a voltage is generated in a conductor as it moves through a magnetic field. This principle is applied to a conductive fluid which flows through the meter tube perpendicular to the direction of the magnetic field. (see the figure 1.) 04 Magnet Coil Metering Tube Electrode Ea B D y E v x z E = Electrode Voltage B = Magnetic Induction D = Electrode Distance V = Average Flow Velocity qv = Volume Flowrate Ea ~ B D v qv = Ea ~ qv D² π 4 v Electrode Voltage Figure 1. Basic operating principle of an Electromagnetic Flowmeter The voltage induced in the fluid is measured by two electrodes located diametrically opposite to each other. This electrode voltage Ea is proportional to the magnetic induction B, the electrode distance D and the average flow velocity v. Nothing that the magnetic induction B and the electrode distance D are constant values indicates that a proportionality exists between the electrode voltage Ea and the average flow velocity v. From the equation for calculating the volume flowrate Ea~qv, it follows that the signal voltage is linear and proportional to the volumetric flowrate.

2. Grounding 2-1. General information on ground connections Observe the following items when grounding the device; - The flowmeter grounding is one of the most important things for flowmeter installation. - For plastic pipes or pipes with insulating lining, the grounding is provided by the grounding ring. - When stray potentials are present, install a grounding ring upstream and downstream of the flowmeter sensor. - For measurement-related reasons, the potential in the station ground and in the pipeline should be identical. Important-Notice If the flowmeter sensor is installed in plastic or earthenware pipelines, or in pipelines with an insulating lining, transient current may flow through the grounding electrode in special cases. In the long term, it may destroy the sensor, since the ground electrode will turn in degrade electrochemically. In these special cases, the connection to the ground must be performed using grounding plates. Install a grounding ring upstream and downstream of the device in this case. 2-2. Metal pipe with fixed flanges Use a copper wire (at least 2.5mm²) to establish the ground connection between the sensor, the pipeline flanges and an appropriate grounding point. 05 CN - 0 CNW-1 Flange Type Earth Ground Wafer Type Earth Ground Figure 2. : Metal pipe, without liner (over 50A sizes)

CN - 0 CNW-1 Earth Ground Earth Ground Flange Type Wafer Type Figure 3. : Metal pipe, without liner (from A to 40A sizes) 06 2-3. Plastic pipes, non-metallic pipes or pipes with insulating liner For plastic pipes or pipes with insulating lining, the ground for the measuring agent is provided by the grounding ring. If grounding electrodes are used, the grounding ring is not necessary. a) Install the flowmeter sensor with grounding ring in the pipeline. b) Connect the terminal lug for the grounding ring and grounding connection on the flowmeter sensor with the grounding strap. c) Use a copper wire (min. 2.5mm²) to link the ground connection to a suitable grounding point. It is essential to use this grounding method in an electrolysis process at a plating factory. CN - 0 CNW-1 Grounding Rings Grounding Rings Grounding Rings Grounding Rings Earth Ground Earth Ground Flange Type Wafer Type Figure 4. : Plastic pipes, non-metallic pipes or pipes with insulating liner

2-3. Ground for pipes with flexible connection For pipes with flexible connection, it should be welded M16 or 1/4 sized bolts on both sides of the pipes as shown the figure 5 to get proper ground results. Make sure to use a copper wire (min. 2.5mm²) to link the ground connection to a suitable grounding point. CN - 0 M16 or 1 4 bolt welded on pipe for grounding flexible connection 07 Flange Type Earth Ground CNW-1 M16 or 1 4 bolt welded on pipe for grounding flexible connection Earth Ground Wafer Type Figure 5. : Ground for pipes with flexible connection

ELECTRO - MAGNETIC FLOW METER 3. Piping Installation 3-1. Upstream Downstream Piping Installation Methods (Standard) To ensure specific accuracy over widely varying process conditions, install the flowtube with a minimum of five straight upstream and two pipe diameters downstream from the electrode plane, as shown below. This flowtube placement is usually adequate to allow for disturbances created by elbows, valves and reducers. 5 Pipe Diameters 2 Pipe Diameters Valve Valve Flow Upstream and Downstream Straight Pipe Diameter 08 NOTE : It can be measured a correct flowrate only when a detector is full with fluid inside completely. Make sure to operate it with fluid in full inside. 3-2. Required Pipe Length on Piping Connections If various joints are used upstream of the detector outlet, the straight pipe length as show in figure below is required. By Pass Line L Horizental Straight Line L = 5D "T" Bow Line L L = 5D L L = 5D : Fully opened sluice valve L = D : Other valves (not fully opened) Reduction & Extension Line 90 Band Line L = D L L = 5D L The figure above required straight pipe length on the upstream side It follows the regulations of JIS B 7554 and KS B 0612 standards for the straight-pipe length installation conditions of electromagnetic flowmeter. Note L : Required straight pipe length-straight pipe length plus half length of the detector. D : Normal bore size (diameter)

Flanged Combined Type www.fckoreains.com

ELECTRO - MAGNETIC FLOW METER 1. Summary The Electromagnetic Flowmeter can be used to accurately measure the flowrate of liquids, paper pulp, slurry and mineral slurry which has an electrical conductivity greater than 20 /cm, is a flow measurement system in a compact design which integrates the primary and signal converter. MODEL TYPE COMBINED TYPE Normal Type EX-Proof Type Option Combined Type () Assembly Way Power Supply I/O Converter Body

2. Specifications MODEL Type Size Process connection Measuring range Accuracy Fluid temperature Ambient temperature Conductivity Power supply Power consumption Display Output Protection class Special feature Combined Type mm (3/8") ~ 1,000mm (39") Flange type-standard KS/JISK RF (Option: ANSI, DIN) 0.2m/s-m/s ±0.5% F.S. (15A~800A) ±1.0% F.S.(900A ~ : It needs for site calibration) Teflon (- ~160 ) Hard rubber (0 ~60 ) - ~60 μs /cm (Option: 5~μs /cm) AC 85-250V (50~60Hz) DC 24V, Surge Arrester Max 15VA LCD Display Flowrate: 5-digit Display Total: 9-digit Display With Back light Analog: 4-20mA (isolated) Pulse: Open Collector Digital: RS485 IP66 Ex-proof: KC, IECEx (Option) - ExdⅡC T5 (IP66) 1 Self check 2 Empty pipe 3 Enable to reverse flow direction 4 Data logging 5 Error message 11 3. Standard Material No. Description Material A ~ 1,000A 1 1 2 3 4 5 Head Body Flange Liner Electrode Cast Aluminum SUS304 SUS304 / Carbon Steel Teflon (PTFE) / Hard Rubber Hastelloy-C Option : Platinum Titanium Tantalum 2 5 4 3 FC KOREA Co., LTD. Address: #173-409, Gajwa-Dong, Seo-Gu, Incheon, Korea 404-811 Tel : +82-32-876-7339 / Fax : +82-32-876-7377 http://www.fckoreains.com

4. Measuring Range In the normal industry application, it is better to set the measured medium speed as 2~4m/s, under the special situation, the minimum speed should be more than 0.2m/s and maximum speed less than 8m/s, if there are solid granules in liquid, the usual speed should be less than 3m/s for purpose to avoid the over-attrition between lining and electrical poles. For viscid liquid, the speed can choose as 2m/s, the fast flow speed makes for the automatic elimination of obstructive substances glued on poles, therefore improve the inspection s preciseness. 12 Size (mm) A 15A 20A 25A 32A 40A 50A 65A 80A 0A 125A 150A A 250A 300A 350A 400A 450A 500A 600A 700A 800A 900A 00A 1A 1400A 1600A 1800A 0A Velocity (m/s) Minimum Flow rate 3 (m /h) 0.08 0.19 0.34 0.53 0.87 1.36 2.12 3.58 5.43 8.48 13.25 19.08 33.91 52.99 Flow range Velocity (m/s) 0.2 76.30 3.86 135.65 171.68 211.95 305.21 415.42 542.59 686.72 847.80 1220.83 1661.69 2170.37 2746.87 3391.20.0 Maximum Flow rate 3 (m /h) 2.82 6.35 11.29 17.64 28.91 45.71 70.58 119.28 180.68 282.32 441.12 636.21 1129.27 1764.48 2540.86 3458.39 4517.08 5716.93 7057.94 163.43 13833.55 18068.31 22867.71 28231.74 40653.71 55334.21 72273.25 91470.84 112926.96 Graph Illustration of Diameter, Flow Speed and Volume of Flowmeter 300 32 0 250 40 65 15 25 50 80 150 350 400 450 mm Flow velocity ( m/s ) 1.0 0.3 0.1-2 -1 1 1 3 Flow volume ( m /h) 2 3 4

5. External Dimension For Integration [ KS / JISK ] Size (mm) Working Pressure (Bar) L (mm) D (mm) K (mm) H (mm) n ØA Integration Weight(Kg) 90 65 300 4-Ø15 6 15 95 70 300 4-Ø15 7 20 0 75 3 4-Ø15 7 25 32 40 125 135 90 0 3 320 4-Ø19 4-Ø19 8 8 40 140 5 330 4-Ø19 9 50 155 120 350 4-Ø19 65 175 140 360 8-Ø19 11 80 185 150 380 8-Ø19 13 0 250 2 175 400 8-Ø19 17 125 16 250 250 2 440 8-Ø23 20 150 300 280 240 460 8-Ø23 30 350 330 290 5 12-Ø23 41 250 400 400 355 570 12-Ø25 58 300 350 400 500 500 600 445 490 560 400 445 5 630 680 730 12-Ø25 16-Ø25 16-Ø27 70 82 6 13 450 500 600 600 620 675 565 620 780 850 20-Ø27 20-Ø27 116 130 600 600 745 730 950 24-Ø33 185 700 700 905 840 80 24-Ø33 230 800 800 20 950 1170 24-Ø33 300 900 00 6 900 00 1120 1235 50 1160 12 1320 28-Ø33 20-Ø39 380 480 H(mm) : Allowance ±mm Integration installation type K n-øa H D L FC KOREA Co., LTD. Address: #173-409, Gajwa-Dong, Seo-Gu, Incheon, Korea 404-811 Tel : +82-32-876-7339 / Fax : +82-32-876-7377 http://www.fckoreains.com

6. Ordering Code MODEL SPECIFICATION DESCRIPTION COMBINED TYPE 14 METER SIZE 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 [Example] CN 0 7 A E A A Model CONNECTION FLANGE STANDARD A B C D E F G H ELECTRODE MATERIAL A B C D E F GROUND RING MATERIAL A B C D E F N LINER MATERIAL A B C A (3/8") 15A (1/2") 20A (3/4") 25A (1") 32A (1-1/4") 40A (1-1/2") 50A (2") 65A (2-1/2") 80A (3") 0A (4") 125A (5") 150A (6") A (8") 250A (") 300A (12") 350A (14") 400A (16") 450A (18") 500A (20") 550A (22") 600A (24") 650A 700A 750A 800A 900A 00A JIS K JIS 16K JIS 20K ANSI 150# ANSI 300# DIN PN DIN PN16 Other 316LSS Ti (titanium) Pt-Ir (platinum iridium) Ta (tantalum) Hastelloy C Other 316SS 316LSS Ti (titanium) Ta (tantalum) Pt-Ir (platinum iridium) Hastelloy C None PTFE HARD RUBBER Other

7. Dimension Size 7-1. Normal Combined Type Electric Connection: M20x1.5(Female) 140 1 130 1 15 7-2. Ex-Proof Combined Type Electric Connection: PF 2" (Female) 140 1 237 150 1 FC KOREA Co., LTD. Address: #173-409, Gajwa-Dong, Seo-Gu, Incheon, Korea 404-811 Tel : +82-32-876-7339 / Fax : +82-32-876-7377 http://www.fckoreains.com

8. Wiring 8-1. Wiring Connection on Converter Description for PCB connection functions COMM Frequency and Pulse POUT Frequency (Pulse) Output for Bi-directional Flow ALM1 Alarm Output for Upper Limit ALM2 Alarm Output for Low Limit COMM Current and Alarm Com IOUT Current Output of Flux (Two Routes Out) Isolated TRX+ + Communication Signal Input TRX- - Communication Signal Input IVIN External DC Power 24V LN- Power Supply LN+ Power Supply 16 Grounding 1) Power : AC 85V ~ AC250V (50~60Hz) 2) Grounding Note: Wires colors are not required. It needs to be inquired question separately for vessel using purpose. COMM P O U T A L M 1 A L M 2 COMM I O U T T R X - T R X + I V I N Function part Power part Fuse

8-2. Controller Wiring Diagram 1) Power : AC 85V ~ AC250V (50~60Hz) 2) Analog Output : DC 4~20mA (Isolated) 3) Pulse Output : Open Collector Pulses 4) Alarm Output : HI & LOW Alarm Output 5) Network Function : RS-485 6) Grounding 7) Surge Arrester 8-3. Controller Wiring Connection Function Pulse IN- Counter Frequency Pulse Output Connection Hi-Alarm Low-Alarm Alarm Output Connection Indicator Analog Output Connection DC 4~20mA (Isolated) PLC DC24V (Pulse+) Communication Connection RS-485 COMM P O U T A L M 1 A L M 2 COMM I O U T T R X - T R X + I V I N 17 Indicator Power supply DC 24V Analog Output Connection DC 4~20mA (2 Wires) FC KOREA Co., LTD. Address: #173-409, Gajwa-Dong, Seo-Gu, Incheon, Korea 404-811 Tel : +82-32-876-7339 / Fax : +82-32-876-7377 http://www.fckoreains.com

www.fckoreains.com