PORTABLE 2 UV CURING SYSTEM OPERATING INSTRUCTIONS

Similar documents
Universal Bench-top Conveyor OPERATOR S GUIDE

Submersible Pond Pump with UV 800 Gallons Per Hour

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

Safety, Installation and Service Manual Models 1952, 1953 & 1972

2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

UV PROCESS SUPPLY, INC.

Premium Pond Pump 330 Gallons Per Hour

Mechanical Filter Box Kit

Container Fountain Kit with LED Light

Premium Waterfall Pump 1200 Gallons Per Hour

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Requests for Daily Care and Maintenance

Illumifalls Patio Pond

Submersible Waterfall Pump 1200 Gallons Per Hour

Installation and Operation Instructions Safety Director Arrow

Door Edge Protection Film 36 inch

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Energy efficient low voltage dichroic mirror halogen reflector lamps

NANOpure Infinity UV Module Upgrade

CeraLux Lamp Module Assembly Instructions

Installation Instructions for Part #: KRB01 Radiator and Reserve Tank Relocation Kit for K-Powered Civics

CeraLux Lamp Module Assembly Instructions

Requests for Daily Care and Maintenance

Mechanical Filter Pump Kit Up to 500 gallons

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

Submersible Waterfall Pump 1250 Gallons Per Hour

DODGE CUMMINS Air-Boss CR Intake Plenum

NEW GEN OWNER S MANUAL

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

HARDWARE KIT INSTALLATION GLOVES

Container Fountain Kit

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Pressurized Pond Filter Up to 850 gallons

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Submersible Waterfall Pump 3600 Gallons Per Hour

EQUIPMENT OPERATION MANUAL. Loctite ZETA 7401 UV Chamber

The Double Ended DE Metal Halide lamp types, up to 1800 micromol/s, are available in 1000W, 6000K for Open rated fixtures.

INFINITY-1 HALOGEN LIGHT BAR INSTALLATION MANUAL 7000 SERIES

Low-Water Auto Shutoff Pump with Light 300 Gallons Per Hour

INFINITY-3 STROBE LED BAR INSTALLATION MANUAL 7700 SERIES

User s guide SIRH series Infrared radiator heater models: SIRH4002W*, SIRH4203W*, SIRH6002W* *Add R for the weather-resistant model

MaxLite LED Linear HighBay Fixtures

Natural Fiber Planter Fountain

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

HyperFlex 12G.

EQUIPMENT Operation Manual. Loctite Zeta 7401 UV Chamber Part Number 98039

Illumifalls Kit REMINDER CALL BEFORE RETURNING TO STORE.

Female Plug. connecting to Fuel Quantity

Guardian NV Flywheel Coupling

Guardian FBA Flywheel Coupling

21", 33", 45", & 61" Installation & Operation Manual

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

OPK-300N OPTIMAX Multi-Lite

Guardian Steel Gear Shaft Coupling

TECHNICAL INFORMATION Puissant 30-Watt Shortwave UV Light Sources Catalog Nos. SKSUV30, SKSUV40

Guardian Taper Grid Shaft Coupling

Submersible Waterfall Pump 3600 Gallons Per Hour

MODEL V-24 OWNER'S MANUAL PARTS

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

END USER TERMS OF USE

Guardian HH Shaft Coupling

Installer s Manual. PCO/UV N-Duct Model

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

EQUIPMENT Operation Manual. Loctite Zeta 7411 UV Flood Curing System. Part Number 98027

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Bulb Replacement REPLACING BULBS

CU6703 Module Installation Guide

UV Flood Curing System

ROOM AIR SANITIZER GERMICIDAL ULTRAVIOLET ADVANTAGES OF THE SANITAIRE SYSTEM

LT-EL138 LED Flashlight

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Further information: Berriman Associates Model 850P.2 Owners Manual

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

INSTALLATION INSTRUCTIONS

Installation Instructions for Part #: KPS01 - KPS07 Karcepts A/C & P/S Removal Kit (With Alternator Relocation)

Operating Manual. Follow all safety precautions!

Do not install and/or operate this safety product unless you have read and understand the safety information contained

4-20 ELECTRONIC VERTICAL FLOW METERS

II DISTRIBUTION & SUBSTATION TYPE C

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

INSTALLATION AND USER INSTRUCTIONS

ARALDITE AV 8574 Resin Hardener HV 8574

20250 Module Installation Guide

Guardian FH Flywheel Coupling

Air-Boss VP Intake Plenum

3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

INSTALLATION NOTES: nbeckon-26

Model E600 Tarping System

FIGURE 310A & 311A 3-PIECE BALL VALVE

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

INTRODUCTION INSTALLATION

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Transcription:

PORTABLE 2 UV CURING SYSTEM OPERATING INSTRUCTIONS

Table of Contents Disclaimer 3 I. Overview 4 II. Introduction 5 III. Positioning 5 IV. Cooling 6 V. Shielding 6 VI. Lamp focusing/mounting 7 VII. Chassis Mounting 8 VIII. Electrical/Start-up 8 IX. Cleaning 9 X. Changing Reflectors 9 XI. Inventory of Replacement Parts 10 2

DISCLAIMER WARNING: 1.) When operating this unit, air flow must be fully unobstructed 2.) User must provide appropriate shielding to protect against UV radiation exposure. 3.) Heat generated from the lamp must be effectively evacuated from within the lamp housing. RECOMMENDATION: We recommend a minimum of 10 CFM of air flow within the lamp housing per 100 watts/inch energy supplied to the UV lamp. IMPORTANT NOTE: Excessive cooling will diminish lamp operating voltage and effectiveness. *In systems provided with a shutter: If the shutter is activated (closed), switch lamp power to low (standby) power. Failure to do so will cause the lamp to overheat, and may cause electrical component (fans, wiring, etc.) failure. LIABILITY LIMITATION: The Buyer of this product accepts full responsibility and understanding for the terms and specifications set forth herein. Con-Trol-Cure makes no claim, expressed or implied, as to the performance of this product. ANY LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED. CON-TROL-CURE s LIABILITY IN ALL EVENTS IS LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID. All risk arising out of the performance of this unit remains solely with the Buyer. In no event shall Con-Trol-Cure be held liable for lost profits, lost savings, incidental or direct damages or other economic consequential damages regardless of any statement, expressed or implied, of such liability by Con-Trol-Cure employees or any of its authorized agents. In addition, Con-Trol-Cure and its suppliers will be held harmless for any damages claimed on behalf of any third party. 3

I. Overview Maintaining a UV curing unit is critical as UV lamps must operate at their peak performance to provide a full cure. CON-TROL-CURE has designed and developed this irradiator system to provide ease of maintenance, flexibility, maximum efficiency and highest UV output. Using field research and state of the art technology, the P2 irradiator requires less effort to produce maximum output with minimal waste. With a maintenance-friendly design, the ability to replace the reflector quickly is a key design feature in our lamp system. The P2 system aims to achieve quick, easy and inexpensive reflector replacement by allowing the elliptical half-side reflectors to be removed and replaced within five minutes. Since you can change the lamp s retrofitted components easily, and, therefore, frequently, you can be assured of maintaining consistent, high UV output. This cost-effective approach ultimately provides the highest level of assurance for effective UV curing. 4

II. Introduction High intensity, medium pressure, mercury vapor lamps can generate extreme heat and corrosive temperatures. However, the P2 s components (thin reflector sheets, gap for cooling and fans) are designed to withstand the harsh environment created within a UV curing chamber, and to provide optimum cooling. IMPORTANT: UV radiation can cause severe burns to eye and skin. Use protective materials (goggles, glasses), filter screens and curtains to ensure personnel safety. Proper maintenance procedures, including maintaining an inventory of spare lamps and reflectors, should also be practiced in order to prevent downtime. III. Positioning As this is a portable device, positioning of this unit for different applications will provide varying cure results. As a benchmark of performance, and to properly position the P2 for most effective curing, please note the lamp s optimal focal point is 3 ¼ measured from the 1/8 (3 mm.) reference hole in the lens housing end plate to the substrate surface. (see Figure 1). The focal point has been factory set for optimum performance. V reflector strip #U004-006 Elliptical half side section Figure 1: Non-Shuttered System 1/8 Reference hole 5

IV. Cooling of Lamp Cooling is accomplished by a thermally activated fan located at one end of the P2 s lamp housing. The fan blows air across both sides of the reflector and away from the lamp. The airflow changes drastically if the fan blows against any static pressure caused by obstructions, therefore, ensure that the fan operates completely unobstructed. *Important note: The fan will only turn on when the lamp reaches operating temperature. This can take 10-20 minutes depending on the positioning of the housing. V. Shielding UV radiation can cause severe burns to eye and skin. Looking directly at the UV light should be avoided. Wearing sufficient shielding and following safety practices are effective protective measures. Personnel must be taught proper precautionary procedures in order to avoid the possibility of skin and eye irritation. The cornea, lens and retina have been shown to be susceptible to damage from light in the ultraviolet, visible and infrared range. By using shielding materials, you can greatly reduce this hazard to a safe level. OSHA requires employers to make available and require employees to wear suitable eye and face protection where eye injuries may occur. In order to help comply with OSHA requirements and provide safety for your personnel, we offer an array of safety glasses and filter materials, which were carefully selected for the needs of UV applications. Protect the eyes by wearing safety glasses or goggles. They provide the best protection from large amounts of UV and visible light. UV Filter Safety Glasses protect the eyes by absorbing shortwave UV radiation to up to 400nm (yellow - # I005-018) (green - # I005-020) (clear - # I005-021) (gray - # I005-022). Disposable UV Filter Glasses (# I005-023) are offered at very low cost to encourage safety-wear even for people visiting your production shop. UV Viewing Goggles glass filter offers maximum eye protection from UV light (# I005-016). Figure 2: UV Filter Safety Glasses UV Filter Screens and Blackout Curtains can also be used to protect personnel from the potential harm of overexposure to UV radiation. However, this is not intended as a substitute for approved eye protection necessary for direct and close range viewing. The Portable UV Filter Screen (# F007-010) will block ultraviolet light emitting from the UV curing equipment. These self-standing screens absorb and filter light waves to 600 nanometers. UV Blackout Curtains (30 x 40 - # F007-018), (37 x 48 - # F007-019), (40 x 50 - # F007-020), (40 x 60 - # F007-021) block out UV light, eliminate light leakage, and allow optimum light penetration. 6

Electrical connections and wires should be examined on regular basis. A harsh UV curing environment produces excessive heat, UV light and (usually) ozone. Exposure to harsh UV will deteriorate the integrity of internal components. However, parts of the irradiator (thin reflector sheets, gap for cooling and fans on top of the lamp housing) are designed to withstand the harmful effects of UV. We strongly recommend maintaining an inventory of replacement parts to prevent downtime. VI. Lamp mounting Before replacing a lamp be sure that the unit has been disconnected from its power source and, if the unit was in use, that the lamp and lamp housing have completely cooled. Two spring loaded lamp holders hold the lamp in place and provide electrical current to the lamp (Figure 3). To install lamp in the lamp housing: 1. The new lamp must be completely free of dirt, grease or fingerprints- failure to do so will contribute to shorter lamp life and decreased performance. Clean the lamp thoroughly using UV Process Lamp and Reflector Cleaning Solution (#A002-019) and a lint free, non-scratch wiping pad such as Webril Handi-Pads (#J006-030). When handling the lamp for installation use Cotton Inspection Gloves (#I004-002). Figure 3 Figure 4 Spring loaded lamp holder 2. Hold the lamp at its middle and insert one end through the unslotted reflector end (Figure 4). Unslotted reflector end 3. Then slide the flattened end of the other side of the lamp down through the slot in the other end reflector (Figure 5). Figure 5 Slotted reflector end 7

4. Insert the ceramic lamp end into the lamp holder on the unslotted side and apply pressure along the length of the lamp, pushing the lamp into the spring-loaded lamp holder (right) until the opposite end of the lamp is free to be inserted into its lamp holder. 5. Inspect you installation to be sure that the lamp is properly seated in the two lamp holders by moving it from side to side to feel the spring tension at both ends. Installing the lamp in the holder *** When installing any lamp, do not touch the quartz envelope directly. Always wear cotton inspection gloves. Do not allow fingers or hands to touch the lamp body after cleaning or during lamp mounting. Dirt and foreign particles can cause a lamp to fail or create an obstruction of the UV light.*** VII. Chassis Mounting The P2 housing features slots along the length of its exterior shell which accept ¼ bolts for attaching different brackets. Configure your P2 mounting needs utilizing these channels. VIII. Electrical/Start-up With the lamp and reflector secured in place, and all shields locked down, you are ready to power up the unit. Plug the female end of the power cord into its grounded outlet at the base of the P2. Plug the male end into a grounded 110V, 15A service outlet. With the reflector and lamp directed away and shielded against harmful exposure, turn the unit On. The P2 will require approximately 10 minutes to reach stabilization. After the warm-up period is complete, the lamp is ready to use for your curing application. IMPORTANT: Remember to wear UV protective eye wear and clothing when operating this system. Also protect from heat exposure as unit temperature may significantly exceed 125 o F. 8

IX. Cleaning Dust and dirt on the lamp should be removed prior to installation to assure that they do not contaminate the quartz. Dirt on the lamp and reflector can cut curability dramatically. Accumulation of deposits during production will prevent uniform delivery of light, reduce UV intensity and lessen cure efficiency. The lamp will absorb the UV energy and turn it into unwanted infrared. Avert equipment failure by proper maintenance. Keeping a log will define future operating procedure and maintenance programs. Prevent costly downtime and ensure maximum UV output by having a routine clean up of irradiator system. All components should be cleaned. C.1. Cleaning the lamp and Reflector Lamp and Reflector Cleaning solution (Part # - A002-019) will prevent of foreign matter from accumulating on the lamp and reflector. Regular use of this cleaning solution to clean lamps and reflectors will ensure optimum light transmission and consistent peak performance. Dampen the lint-free wiping towel (Part # - A002-021) with the said lamp cleaning solution. Wipe the UV lamp directly with the dampened cloth. Dry and polish lamp with a clean wiper. Use a lint free wiper that contains no chemical binds. Figure 7: Lamp and Reflector Maintenance Kit Always wear cotton inspection gloves (Men s - #1004-022) (Ladies - #1004-031) when handling the UV lamps. Do not allow fingers or hands to touch the lamp body after cleaning or during lamp mounting. The CON-TROL-CURE UV Lamp and Reflector Maintenance Kit (see Figure 14) contains everything you need to clean UV lamps and reflectors thoroughly: cleaning solution, soft, lint-free wiping towels and cotton inspection gloves. X. Changing Reflectors The reflector is a vital component in the irradiator system since it affects the amount of light focused on the curing surface. During production, various deposits accumulate on reflector surfaces and will greatly lessen cure efficiency. You may choose to replace the reflector rather than clean it. It is advisable to change the reflector once they become contaminated, scratched, or once their mirror-like appearance. 9

The P2 s design allows easy, low-cost reflector replacement so you can change the reflector as frequently as necessary, quickly and economically. The lamp housing reflector kit consists of the V reflector strip and elliptical half sides (see Figure 1). Figure 8: View of Reflectors Replace the V reflector strip, elliptical half side section (V reflector strip and elliptical half side section - #U004-006) found on the center of the lamp housing by alternately twisting it behind the hooks of the rib. Make sure the hooks are alternately opposite each other. If the first hook on the first rib is on the right side, the second hook on the second rib must be on the left side of the lamp housing. Highly polished reflector ends are critical since the lamp degradation begins at the lamp s ends. The reflector end (#U004-009) helps ensure greater consistency along the entire length of the lamp. By removing the side shield on the lamp, the elliptical half side reflectors pop out for easy replacement. Figure 9: With side shield removed, reflectors can be easily replaced. Changing reflectors frequently is a cost-effective measure, since it provides the highest level of assurance for effective and consistent UV curing. When cleaning reflectors, use the same cleaning procedures as recommended for cleaning lamps. Never use abrasive cleaning compounds or steel wool. These harsh products will remove its reflective finish and reduce the reflector s efficiency. XI. Inventory of replacement parts Lamp burnout and failure cannot be predicted. Avoid costly downtime by keeping a proper inventory of replacement parts. We stock a huge variety and inventory of UV lamps. Since our volume of lamp purchasing is greater than any equipment manufacturer, our prices are competitive with other lamp sources. In addition to lamp and reflector maintenance supplies, be sure to purchase filter materials, ballast and condensers. 10

This document provides information about a product distributed by UV Process Supply, Inc ("the Seller"). The information provided in this document is offered in good faith and is believed to be reliable, but is made WITHOUT WARRANTY, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER. This document is not intended to provide advice (technical, legal or otherwise) for a particular set of facts, but is of a general nature. Users of this document should consult with their own advisors and appropriate sources. The Seller and its employees do not assume any responsibility for the user's compliance with any applicable instructions, laws or regulations, nor for any persons relying on the information contained in this document. All risk arising out of the performance of this product and/or the understanding of its usage remains solely with the Buyer. In no event shall the Seller be held liable for lost profits, lost savings, incidental or direct damages or other economic consequential damages regardless of any statement, expressed or implied, of such liability by the Seller's employees or any of its authorized agents. In addition, the Seller and its suppliers will be held harmless for any damages claimed on behalf of any third party. The Buyer of this product accepts full responsibility and understanding for the terms and specifications set forth herein. 11