Common Bus and Line Regeneration

Similar documents
SDC,Inc. SCR-Regenerative Ac Drive

For motors controlled

AC DRIVES. AC Drives. The word "drive" is used loosely in the industry. It seems that people involved

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

U1000 INDUSTRIAL MATRIX DRIVE

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

American Traction Systems

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

Application Note CTAN #127

The cement and minerals industry

DC-DC CONVERTER. 5.1 Advantages & Disadvantages of DC-DC Converters

Optimizing Drive Systems for Energy Savings

The Application of Power Electronics to the Alberta Grid

Innovative Power Supply System for Regenerative Trains

Philosophy of Topology and Component Selection for Cost and Performance in Automotive Converters.

V1000, A1000, E7, F7, G7,

AC/DC FFE converter power module

When to use a Soft Starter or an AC Variable Frequency Drive

SPIRO SOLUTIONS PVT LTD POWER ELECTRONICS 1. RENEWABLE ENERGY PROJECT TITLES I. SOLAR ENERGY

CT430 - Soft Starters on Motor Applications

Development of the Regenerative Power Compensation Device SANUPS K23A (R Type)

Application Case. Issued by Solution Center Date May, 2013 Pages 5

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Inverter with MPPT and Suppressed Leakage Current

VFD Best Practices: Getting the Most from Your VFD Investment

An Energy Efficiency Measurement Scheme for Electric Car Charging Pile Chun-bing JIANG

ECE1750, Spring Motor Drives and Other

Implementation of a Grid Connected Solar Inverter with Maximum Power Point Tracking

690-V Inverters Equipped with SiC Hybrid Module FRENIC-VG Stack Series

MX1S Matrix Converter

Energy recovery during the braking operation

NOVEL MODULAR MULTIPLE-INPUT BIDIRECTIONAL DC DC POWER CONVERTER (MIPC) FOR HEV/FCV APPLICATION

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies

Targeted Application of STATCOM Technology in the Distribution Zone

Application Note. Common Bussing AC Drives. For 650 and 690+ series drives APP-AC-03

Research Paper MULTIPLE INPUT BIDIRECTIONAL DC-DC CONVERTER Gomathi.S 1, Ragavendiran T.A. S 2

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Hitachi America, Ltd.

Variable Speed Drives in Electrical Energy Management. Course Content

Welcome. Yaskawa Training Café Through the Combined Efforts of Drives Engineering and Technical Training Services

Frequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Steve Schouten. Donna Densmore

Technical News. Drives: benefits, operation, pitfalls and harmonic solutions. Issue #59 - January 2011

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Exercise 7. Thyristor Three-Phase Rectifier/Inverter EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Thyristor three-phase rectifier/inverter

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Diesel-Electric Propulsion Systems Power under Control

POWER ELECTRONICS & DRIVES

Energy Storage for Traction Power Supply Systems

Energy 142 NABCEP (North American Board of Certified Energy Practitioners) Entry Level Test Review. System Components

AC Adjustable Speed Drives (ASD s)

Features IN THIS CHAPTER

SECTION 3 HPS CENTURION R REACTORS AND RC DV/DT FILTERS

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Implications of. Digital Control. a High Performance. and Management for. Isolated DC/DC Converter. Technical Paper 003.

Industrial Motors. But first..servos!

Implications of. Digital Control. a High Performance. and Management for. Isolated DC/DC Converter. Technical Paper 003.

Eskisehir Light Train- Correcting Capacitive

Power Electronics Projects

GREE Photovoltaic DC Inverter Centrifugal Chiller

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

VARIABLE FREQUENCY DRIVES

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Creating Efficient Solutions for Motor Drive-based Systems CIRCUIT PROTECTION WHITE PAPER

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Three-Phase Power Conversion in a Single Step

Implications of Digital Control and Management for a High Performance Isolated DC/DC Converter

Contents. Prefece. List of Acronyms «xxi. Chapter 1 History of Power Systems 1

USOO A United States Patent (19) 11 Patent Number: 5,892,675 Yatsu et al. (45) Date of Patent: Apr. 6, 1999

Table of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1

Question Number: 1. (a)

PVI1000 : Outdoor High-Efficiency Power Conditioners for Mega Solar Projects

Study Solution of Induction Motor Dynamic Braking

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Five Reasons for VFDs in HVAC Applications

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

FRENIC-Mega Series of High-performance Multi-function Inverters

Ms.P.Ranjani/AP. Ms.M.Lincy Luciana/AP. Neural network based method for non linear load harmonics. Mr.S.Vignesh/AP

POWER ELECTRONICS TITLES LeMeniz Infotech

Technical Explanation for Inverters

RU Series AFE Unit & Regeneration Unit

LOAD SHARING WITH PARALLEL INVERTERS FOR INDUCTION MOTOR DRIVE APPLICATION

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

High-Voltage, High-Current DC- DC Converters Applications and Topologies

STUDY OF LARGE VSI DRIVE SYSTEM FOR OIL AND GAS INDUSTRY

Understanding The HA2500's Horiz Driver Test

Optimizing Drive Systems for Energy Savings

Liebert. FP 50Z kva

APPLICATION NOTE USING A MODEL 3060-MS AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract. Introduction. Dissipative Load Bank

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

ADF. Restoring the perfect wave

Medium voltage drive for single or multimotor applications, 3 27 MW

Oftentimes, that isn't the end of the story for the engineer.

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Kinetics Industries Inc. 140 Stokes Ave. Trenton, NJ Fax

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.

A new static DC drive system with AFE for mining excavators

Transcription:

Common Bus and Line Regeneration Addressing VFD applications when Regenerative Energy is Present Steve Petersen, Drives Technical Training Yaskawa America, Inc.

Variable frequency drives (VFDs) are implemented on a huge variety of applications due to their high performance, reliability, and energy savings. However, as with everything, there are some shortcomings with VFDs. The input diode bridge on most VFDs consists of six diodes. These diodes make up the converter portion of a VFD and rectify the 3-phase AC input to a fixed DC voltage. The current flow in the converter portion is typically unidirectional. This is a non-issue in a majority of applications. An issue arises when an application has regenerative energy present. Regenerative energy is present when a motor is braking or overhauling due to the load. This causes the motor to act as a generator with the energy flowing back into the VFD. The diode bridge will stop current from flowing back to the line; thus charging up the DC bus capacitors and potentially causing faults due to high DC bus voltage. In this article we will address this challenge by comparing various solutions which use line regeneration and common DC bus arrangements. The differing available solutions also entail varying benefits and opportunities for reduced space requirements, cost reduction, energy savings and increased reliability. Common DC Bus An application consisting of as few as two VFDs can benefit from a common DC bus. Sometimes called a shared bus, a common bus is established by simply interlinking the DC bus between VFDs via a fused connection (Figure 1). The key benefit of a common bus is the sharing and balancing of power. For example, take a system with two VFDs and two motors; one motor may be in a motoring state while the other motor is in a regenerating state*. During this condition the motoring VFD will consume the regenerative power instead of pulling from the grid. A reminder, two common conditions which can cause regeneration are an overhauled motor or when a motor is braking. In this article, regenerative energy can also be called braking energy. For simplicity we will just stick with the term regenerative. There are multiple ways to establish a common DC bus, each with its own strong points. However, there is no sole best method, as applications can vary wildly and system needs and cost must always be considered. *Motoring when an electric motor is converting electrical energy into mechanical energy to perform work Regenerating - when a motor is overhauling or braking it acts such as a generator. Mechanical energy generates electrical energy

A large stand-alone 6-pulse diode bridge rectifier can be purchased to establish a common bus. The diode bridge is used to rectify the AC input power to DC. The diode bridge must be sized appropriately to power all the connected VFDs and loads. The diode bridge is identical to the converter section of many VFDs. Inherently it is unidirectional, meaning that excess regenerative energy cannot be sent back to the grid. Motoring loads must be greater than regenerating loads to keep the voltage of the DC bus at a safe level. When regenerating loads is greater than the motoring loads then a common dynamic braking package or line regeneration must be implemented. Alternatively, when the amount of regenerative energy present is low you will find that wiring is simple and also reduced compared to a standard AC setup. (Figure 2) Line Regeneration If it is necessary to return excess regenerative energy to the grid this is where line regeneration comes into play. When excess regenerative energy is applied back to the line it is called line regeneration. To accomplish this, a regenerative converter is implemented. This converter is wired into the common DC bus just like the existing drives. This converter takes in excess DC from the bus and outputs a six-step waveform back to the grid. This results in reduced operating costs due to recycling the regenerative power back to the supply. The capacity of the regenerative converter is determined based on the total regenerative energy present. Instead of using a stand-alone diode bridge rectifier to provide a system with DC power, it may sometimes prove beneficial to use a larger VFD. A VFD has a built in rectification circuit on its front end. A common bus can be established by sizing the VFD to supply DC power to the connected VFDs and

motors. This topology is reflected in Figure 3. Note that when comparing this setup to Figure 2, the stand-alone rectifier is eliminated. The second VFD is being powered from the DC bus of the first one. This makes wiring simpler while keeping costs down. An industrial centrifuge is good example of application which would benefit from a common DC bus. A centrifuge consists of a main drive, which turns the drum, and a back drive, which turns the auger at a speed slightly slower than the drum to separate fluids or solids. The back drive is typically a smaller capacity than the main drive. In this application, the back drive is in constant regeneration since it is acting as a brake. This braking energy can be used to power the main drive, which is motoring. When the main drive needs to stop there is a huge inertial load present. This causes the regenerative energy to be excessively high during deceleration and warrants the need to send the power back to the grid through a regenerative converter.

Costs and space requirements are always a top priority. These are directly proportional to the amount of regenerative energy present. Therefore it is extremely important that an engineer confirms the amount of regenerative energy on a given application. Knowing this, the engineer can then either opt to oversize the larger VFD to increase bus capacity or utilize a regenerative converter to apply energy back to the grid. If the amount of regeneration taking place is low a dynamic braking setup will be the most cost effective solution. Dynamic braking simply burns off the excess voltage onto a bank of resistors. If it has been determined that a regenerative converter is necessary, take note of the additional devices which are required when using it. (Figure 3) The reactors are necessary to limit current being supplied back to the grid and also provide additional impedance between the AC source and load devices. There is also a detection circuit which is wired directly from the converter to the power supply. This circuit is used to detect the power supply phase order and voltage levels. Whenever a common DC bus or line regeneration is being considered, it is absolutely necessary to follow the manufacturer s wiring requirements for each device in the system. Pay particularly close attention to fusing recommendations, peripheral devices, power up sequencing, and maximum lengths for DC bus lines.

Harmonics and Active Front Ends The input diode bridge on a VFD conducts the line current in a discontinuous (non-linear) fashion. This is due to the input diodes only conducting during the peak voltage amplitude of each input phase. The result is a rippled voltage waveform, in turn causing input current distortion and harmonics applied back to the supply. A regenerative converter is always wired in parallel to the VFDs on a common bus. The VFDs diode bridge is not isolated from the supply. This means that the converter will not help mitigate harmonics generated by the diode bridge. Typically, when harmonics are a concern, passive front ends consisting of various reactors, filters, and multi-pulse transformers are implemented. These techniques will decrease harmonics but cannot handle line regeneration. Additionally, passive front ends tend to be both expensive and bulky. To mitigate harmonics while also allowing for line regeneration, a regenerative active front end (AFE) must be used. A regenerative AFE is wired in series with the VFDs being powered from it (Figure 4). Harmonics are low due to passive filtering and reactors paired with the AFE in combination with a pulsewidth modulated (PWM) switch array on the input of the front end. Fly back diodes on the insulated gate bipolar transistors (IGBTs) are used to rectify AC to DC for powering one or multiple drives. Additionally, the IGBTs use PWM to reconstruct an AC sine wave by switching the DC bus voltage back onto the supply when regenerative energy is present, making the AFE bidirectional.

Sizing a regenerative AFE is a matter of simple addition. Add up all VFD capacities which will be powered by the AFE. For example, an application is running four 45 kw VFDs and would like to know what size regenerative AFE to select. Formula: 45 kw x 4 = 180 kw Using very simple math we find that the AFE must be rated for at least 180 kw. This rating is required since the AFE is being used as a power supply for all of the connected VFDs. This differs from the regenerative converter mentioned earlier which was sized based solely on the amount of regenerative energy present.

Conclusion Deciding upon which components and setup is right for your system will take some research and evaluation. The amount of regenerative energy present, harmonic content, and cost should all be considered and prioritized. Upon selecting and implementing a common DC bus arrangement substantial energy savings and benefits can be realized.