Industry. Contents. Flender Foaming Test GG-V 425 Rev.1 Description of the testing instrument; carrying out the test; criteria

Similar documents
Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Fixed displacement radial piston pump

Radial piston pump, fixed displacement

Radial piston pump PR4 Series 1X

RENEP CGLP. High-performance slideway oils for machine tools, with excellent demulsification properties. Description. Advantages

Radial piston pump PR4 series 1X

High-performance slideway oils for machine tools, with excellent demulsification properties

Fixed Displacement Motor A10FM A10FE

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Klübersynth GH 6 oils Synthetic gear and high temperature oils

COOLING AND LUBRICATION SYSTEM

PROCEDURE FOR CHECKING FLUIDS (MILLS)

Operation Manual. Turboflotor Protein skimmer for aquaria up to 5000 litres

OLEOIDRAULICA RACCOMANDAZIONI CETOP ELIMINATE & CORRISPONDENTI NORMATIVE ISO

Output flow In l/min at 1500 min

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Oil/Air Lubrication Systems for Steel Production Facilities

TECHNICAL SPECIFICATIONS

Gear Pumps KF 0 Gear Pumps KF 0 with magnetic coupling

European Fire Pump Listing

APPLICATION NOTE. Mounting instructions for EasyPIM 750 and EasyPACK750 Modules with screw clamps

HAWLE-AIR RELEASE VALVES

TABLE 1: COMPARISON OF GREASE AND OIL LUBRICATION. housing structure and sealing method. speed. cooling effect. removal of foreign matter

Power Units / Systems

Higher performance. through longer life of gear units

655001G G

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

Biodiesel Unit Lesson 2

Type KKP. Combination pumps

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

MIXING DIFFERENT APPROVED BRANDS OF TYPE II IS AUTHORIZED. REFER TO THE GENERAL ELECTRIC SERVICE MANUAL BEFORE MIXING OIL BRANDS.

Page Customer Letter/ Warranty Scope Operating principle Construction Gas conveyed Working conditions...

Axial Piston Fixed Displacement Pump KFA

External gear pump Series G

Installation, User and Service Manual. Filter Unit WP1-B2-200

GD series Submersible Grinder Pump

Technical Series, Edition 16

Fixed displacement vane pumps Types PVV and PVQ

Vane pumps, direct controlled Type PV7...A

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Installation Notes for Ford Excursion 7.3L

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

PLANTOGEAR S. Environmentally acceptable lubricating oil and EP industrial gear oil based on synthetic saturated esters.

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

AXIAL PISTON PUMPS AND MOTORS

Axial Piston Fixed Pump A17FNO Series 10

2.4 HEAVY DUTY SERIES

Multiple disc brakes. pressure released and spring operated multiple disc brakes series LBD T brake. Installation- operating instructions

Axial Piston Variable Pump A2VK

Instructions for Installation, Operation, Care and Maintenance

In line high pressure filters. HF 725 series

Clamping and drive module

Thank you for selecting the GD submersible grinder pump.

Power Jacks have taken time, engineering excellence and the best people to produce the ultra compact Neeter Drive gearbox.

Lubrication system components

Handbuch für installation, betrieb und wartung Planetengetriebe

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

ADDINOL Eco Gear. The innovative solution for industrial gear sets. Welcome to the World of ADDINOL

OML and OMM Orbital motors. Technical Information

In line high pressure filters. HF 735 series

DIRECT CURRENT MOTORS

Axial Piston Fixed Motor A10FM / A10FE (US-Version)

TRUCK TYRE PRESSURES EFFECTS ON TRUCK AND ROAD

Wind Turbine Gear Lubricants

Internal gear pump Type PGH Fixed displacement

Feed Pumps VP / VPB / VPBM

Manual Kinematic Viscosity Bath Tamson TV12

Don t Freeze the Engine

RANDO HDZ. Rando HDZ, our premium, zinc additized, anti-wear hydraulic oil that helps provide you with:

RENOLIN CLP PLUS Long-term approved special gear oils with extremely high ageing stability and excellent detergency (DD) selfcleaning

SEM.Test Compliance Service Co., Ltd

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

WJ STEERING 19-1 STEERING CONTENTS POWER STEERING 3.1L VM DIESEL... 1 POWER STEERING PUMP 3.1L VM DIESEL... 2 POWER STEERING 3.

KISSsoft 03/2017 Tutorial 15

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

PNEUMATIC BOOSTER HIROTAKA MFG. CO.,LTD.

The range of products is completed by a number of accessories, including:

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

MATERIAL SPECIFICATION FOR EMULSIFIED ASPHALT

ASV Eccentric Pumps Type F and Type L

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

HYDRAULIC POWER UNITS ENERGY-SAVING HYDRAULIC POWER UNIT-TOYOPAC ECO K 2. Features. Description of the model designation.

Maintenance and repair of Gear Pump Test Rig

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Flow sharing control block in mono block / sandwich plate design M6-15

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

Starting up hydraulic systems

External gear pump Series G

AV 23 Balancing valves SETTER Inline

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

Flow sharing control block in mono block / sandwich plate design M6-22

Transcription:

Contents 1 Introduction...3 2 Description of the testing instrument...3 3 Carrying out the test...6 4 Evaluation and assessment of the foaming characteristics...7 5 Literature...7 6 Enclosures...7 _ Page 2 of 7

1 Introduction Excessive foaming and too slow an air release of dispersed air in gear oils have a negative influence on the load carrying capacity of gears and bearings. In addition, excessive foaming can result in oil leaking at shaft seals and breather screws. This is why gear oils should be checked for foaming characteristics and air release properties. In the "Flender Foaming Test", a gear pair rotates in the oil to be tested and thus mixes air into the oil. In this way it is possible to test in the short term how oil behaves with regard to the absorption of air, oil-air dispersion, and surface foam as well as their regeneration under boundary conditions as exist in gear units. 2 Description of the testing instrument The testing instrument is a closed housing to take one litre of the oil to be tested. In the housing with inside dimensions of 140 x 90 x 160 mm, two shafts are arranged vertically and supported in rolling bearings. The gears, serving to mix the oil with air, are fitted in the centre of the shafts. Technical data of the spur gears: Centre distance a = 50 mm Module m = 2 mm Facewidth b = 20 mm Numbers of teeth z 1, z2 = 25 The gears are arranged with their shafts vertically in such a way that with an oil filling of one litre (1000 cm 3 ) they dip into the oil to the centre of the teeth. In this way, an optimum amount of air is supplied to the oil. One of the two shafts is driven by a three-phase motor flanged to the housing upper part by means of a bell housing. Motor shaft and gear shaft are connected by means of a flexible coupling. Technical data of the motor: Power rating: P = 0.55 kw Speed: n = 1400 ± 5 rpm An opening is milled into the housing front and closed by means of a glass pane. The pane is provided with a scale from which the percentages of changes in oil volume can directly be read during the foaming test. The filling height of the oil sample before the test is started and after a starting temperature of 25 C 0.5 C has been reached is marked as the zero line. At the housing back wall, a heater with a heating capacity of 160 Watt is installed by means of which large-surface heating of the lubricant is achieved with low specific heat load. The oil temperature is always measured by means of a resistance thermometer which is fitted into the housing and has a measuring range between 0 and 60 C. The housing is provided with oil filler plug and oil drain valve for filling and draining. A diagrammatic view of the testing instrument is shown in Figure 2.1. In addition, the testing instrument is shown in a photograph in Figure 2.2. Page 3 of 7

Fig. 2.1: Diagrammatic view of the testing instrument Antriebsmotor driving Öleinflüllöffnung oil filler Sichtfenster inspection glass mit Skalierung with scale Zahnradpaar gear pair Ölablaßhahn oil drain valve Fig. 2.2: General view of the testing instrument Page 4 of 7

Fig. 2.3: View into the oil-filled working chamber of the testing instrument showing the gear teeth and the scale with indication in volume percent The photos in Figures 2.4 and 2.5 show by way of example different conditions of gear oil during a foaming test. Fig. 2.4: Example "Condition of the oil 1 minute after stopping the motor" Page 5 of 7

Fig. 2.5: Example "Change in the condition 5 minutes after stopping the motor" The Flender foam tester can be acquired by purchase from the company Strama-MPS in Straubing. 3 Carrying out the test First, a quantity of one litre of the oil to be tested is filled into the housing of the testing instrument via the oil filler hole. Prior to filling in the oil, the inside of the housing must be thoroughly cleaned, since contaminants or oil residues of former tests will have an influence on foaming. By means of a heater, the oil is slowly heated to a test temperature of 25 C 0.5 C in such a way that the testing instrument has approximately the same temperature (temperature equilibrium). It proved worthwhile to heat the oil to a temperature higher by 2 to 3 C and then let the oil temperature drop to the test temperature of 25 C. When the test temperature is reached, the oil level must be checked (zero line) and possibly corrected. The real test is started by starting the motor for a running time of 5 minutes 3 seconds. When the drive has been shut down, the increase in volume must be determined making a distinction between oil-air dispersion and surface foam. It turned out that the first reading for higher viscous oils does not always exactly represent the increase in volume because oil is still running down on the internal walls. Therefore, a second reading is taken after one minute. From this point of time it is possible to make a clear distinction between oil-air dispersion and surface foam. Over a period of 90 minutes, readings of the development of the foam are taken at fixed intervals and documented in a form sheet (see enclosure). The values for total increase in volume, oil-air dispersion, and surface foam must be entered in the specified columns. As soon as the surface foam does no longer constitute a closed area, i.e. tears open, or forms foam isles, the surface foam volume is determined at 1%. In addition to the foam percentages, the oil temperature is recorded at least every 30 minutes. Before the next test can be made, the lubricant must be drained and the oil chamber thoroughly cleaned. To prevent corrosion in the testing instrument it is recommended to drain the oil and clean the chamber only until shortly before the new test is started. For cleaning, the foam tester must be disassembled and the individual parts must be cleaned separately. We recommend using Castrol Techniclean AS 40 for cleaning. Page 6 of 7

At present, the description of the testing instrument and the test procedure of the Flender Foaming Test are part of a standardization project which will be published as ISO standard 12152. 4 Evaluation and assessment of the foaming characteristics The time rate of foam development is shown in a chart (enclosure), where the curves of the oil-air dispersion and the surface foam are outlined over the rest period. The increase in volume caused by the rise of the oil temperature (approx. 2 to 3 C) is below 0.5% even in case of oils with higher viscosity and thus can be neglected. Assessment criteria which can be derived from the depiction are the volumes of the oil-air dispersion and the surface foam as well as their times of regeneration. In comparative tests, the charts can be directly used for assessment. For the evaluation of the foaming characteristics, two criteria are to be considered: 1. The percentage increase in the oil volume one minute after stopping the testing instrument (oil-air dispersion + foam) is rated as follows: up to 5% good foaming characteristics up to 10% satisfactory foaming characteristics up to 15% still acceptable foaming characteristics above 15% unacceptable foaming characteristics 2. The percentage increase in the volume of the oil-air dispersion five minutes after stopping the testing instrument is rated as follows: up to 4% good air release property up to 7% satisfactory air release property up to 10% still acceptable air release property above 10% unacceptable air release property The two criteria are equal. The more critical result is decisive for the rating of the oil. Oils with a percentage total increase in volume above 15% one minute after stopping the motor or a percentage increase in volume of the oil-air dispersion above 10% five minutes after stopping the motor are not recommended for use in industrial gear units since they have a negative influence on the load carrying capacity of the gear teeth. 5 Literature ISO/DIS 12152 Lubricants, industrial oils and related products Determination of the foaming characteristics and air release properties of industrial gear oils by using a cylindrical gear testing instrument Flender Foaming Test procedure 6 Enclosures Example of a test report Page 7 of 7

Test of the foaming characteristics and air release properties of gear oils on a cylindrical gear test rig (Flender Foaming Test) acc. to ISO/DIS 12152 and GG-V 425 Rev. 1 (Evaluation acc. to GG-V 425 Rev. 1) Page 1 of 3 Sample number: ISO VG: Sample designation: Date of receipt of sample: Date of test: _ Order number: Client: Notes: The analyses on which this test report is based have been made in accordance with the test procedures currently in force. Signature of the inspector Name of the inspector in block letters This test report consists of 3 pages (inclusive of this one) and only refers to the tested items. According to DIN EN ISO 17 025 it is not allowed to duplicate this test report without the consent of the testing laboratory. Name and address of the testing laboratory Enclosure

Test of the foaming characteristics and air release properties of gear oils on a cylindrical gear test rig (Flender Foaming Test) acc. to ISO/DIS 12152 and GG-V 425 Rev. 1 (Evaluation acc. to GG-V 425 Rev. 1) Page 2 of 3 Sample number: ISO VG: Sample designation: Time after stop of motor [min] Temperature [ C] Total increase oil-air dispersion Volume changes [%] surface foam Total increase Limit *1 oil-air dispersion Total evaluation: *) Limits according to current "Specification for the approval of gear oils for FLENDER gear units" Rating before start 25,3 0 10,5 10,5 0,0 1 11,0 7,5 3,5 15 passed 3 11,5 6,0 5,5 5 12,0 5,5 6,5 10 passed 10 12,0 4,0 8,0 15 12,0 4,0 8,0 20 12,0 3,5 8,5 30 28,3 12,0 2,5 9,5 45 12,0 1,0 11,0 60 26,8 12,0 0,0 12,0 90 25,8 8,0-1,5 9,5 passed Graphical representation of the test results 14 12 10 Increase in volume [%] 8 6 4 2 0-2 -4 0 10 20 30 40 50 60 70 80 90 Test period [min] Total increase Oil-air dispersion Enclosure

Test of the foaming characteristics and air release properties of gear oils on a cylindrical gear test rig (Flender Foaming Test) acc. to ISO/DIS 12152 and GG-V 425 Rev. 1 (Evaluation acc. to GG-V 425 Rev. 1) Page 3 of 3 Sample number: ISO VG: Sample designation: 1 minute after motor stop 5 minutes after motor stop Enclosure