Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Similar documents
Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

7 Lighting Technology

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

7 Lighting Technology

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire with LED Series EXLUX 6402/2

Sheet-Steel Light Fittings Series 6014 / 6414

Compact Sheet-Steel Light Fittings Series 6114/1

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Compact Sheet-Steel Light Fittings Series 6114

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight LED Series 6525

Floodlight LED Series 6525

7 Lighting Technology

Plug and Socket Devices SolConeX 16 A Series 8570

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Terminal Boxes Series 8125

Floodlight LED Series 6125

Sheet Steel Emergency Light Fitting Series 6018

Load disconnect switch Series 8146/5-V11

Floodlight Series 6121

Floodlight Series 6521/4

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Linear Luminaire for Fluorescent Lamps

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Safety Switches Series 8537

Tank Inspection Lights Series 6122

Position Switches Series 8060/2

Position Switches Series 8070/2

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Position Switches Series 8074/2

Control Buttons / Switches for Panel Mounting Series 8003

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Tubular Light Fitting with LED Series 6036

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

7 Lighting Technology

Ex UPS standard Series 8265

Control switch/load disconnect switch Series 8008

7 Lighting Technology

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Linear fluorescent luminaire LED V-CG-S

Battery Boxes Series 8316

Linear Luminaire with LED

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Pendant Light Fitting IEC

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Portable Lamps Series HS6145, HSL145

Control Device System NEC Series ConSig 8040

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Load and Motor Switches, Load-Break Switches Series 8549

Control Buttons Series 8082

Metal Position Switch Series 8074

Operating Instructions

10 Load and Motor Switchgear

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

K: bracket type. L: pole type

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Load and Motor Switches, Load-Break Switches Series 8544

Linear fittings EVDL LED fitting - zones 21, & 22

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

EXEL-L. Detail of the internal side. Transparent polycarbonate

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Linear fittings EVNL LED fitting - zones 2, & 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Operating Instructions

Load and Motor Switches, Load-Break Switches Series 8544

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Terminal Boxes Series 8252/1

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Easy and safe installation

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Transcription:

> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600 are useable for normal lighting, but also as group or centrally-supplied emergency light fitting. ATEX / IECEx / GOST NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 6600/52 and 6600/54 6600/56 x x x 6600/52 and 6600/54 x x x 6600/56 x 6600/52 and 6600/54 x 6600/56 x x x x x x x x x x WebCode 6600A Lighting /1

Selection table Version Lamps Electronic ballast Order number Weight Number of lamps Lamp wattage W kg ECOLUX 6600 1 18 1 channel ECG 6600/521-8...-6... 2.500 2 18 1 channel ECG 6600/522-8...-6... 2.500 1 36 1 channel ECG 6600/541-8...-6... 4.600 2 36 1 channel ECG 6600/542-8...-6... 4.600 1 58 1 channel ECG 6600/561-8...-6... 5.800 2 58 1 channel ECG 6600/562-8...-6... 5.800 Order number supplement Through wiring Standard: without 6600/...-.0..-... Special: with 3 conductors 6600/...-.3..-... Special: with 5 conductors 6600/...-.5..-... Cable entry Standard: M25 x 1.5; 1 cable entry, 6600/...-..2.-... 2 stopping plugs Special: M20 or M 25 in moulded material or metal Specify on order 6600/...-..1.-... Switching off Standard: without 6600/...-...0-... Special: with switch 8080, 2-pole 6600/...-...1-... ECG 220... 240 V 1xDC (18 W, 36 W and 58 W; IEC-standard) 6600/...-...-0... 110... 240 V 1xDC (18 W and 36 W; IEC-standard) 6600/...-...-4... 120... 277 V 2xDC (17 W, 32 W and 40 W; NEC-standard) 6600/...-...-8... Terminal strip Special: terminal strip 8184, 4 / 6 mm 2 solid / finely stranded 6600/...-...-.1.. Standard: WAGO 265 2.5 mm 2 6600/...-...-.2.. Number of terminals Standard: with 3 cores; L1 + N + PE 6600/...-...-..3. Special: with 5 cores; L1 + L2 + L3 + N + PE 6600/...-...-..5. Address module Standard: without 6600/...-...-...0 Special: ADR20 ILS 6600/...-...-...2 Note The light fittings are supplied without tubes and mounting accessories. These parts must be ordered separately. Explosion protection Explosion protection Global (IECEx) Gas and dust IECEx BVS 07.0023X Ex na II T4 Gc Ex tc IIIC T * C Dc oder Ex tb IIIC T * C Db * surface temperature see test certificate Europe (ATEX) Gas Zone 2: DMT 01 E 085 X Zone 2: E II 3 G Ex na IIC T4 Gc Dust Zone 21: DMT 01 ATEX E 086X Zone 22: DMT 01 E 085X Zone 21: E II 2D Ex tb IIIC T * C Db Zone 22: E II 3D Ex tc IIIC T * C Dc * surface temperature see test certificate Certificates and approvals Certificates Other approvals IECEx, ATEX, Brazil (UL do Brasil), Kazakhstan (GOST-K), Russia (GOST-R), USA Canada (FM), Belarus (GOST-B), Taiwan (ITRI) ship approval (GL) /2 Lighting

Technical data Electrical data Ballast Power factor cos p Disconnection of the light 6600/5..-...-0... 6600/5..-...-4... Lamp start Cold start Cold start Voltage 220... 240 Vac 110... 240 Vac Voltage 198 264 Vdc 104 264 Vdc DC during switching on Voltage 176 264 Vdc 104 264 Vdc DC during operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC with 1 lamp with 2 lamps Lamps standard IEC 60081 IEC 60081 Lamp power 18, 36, 58 W 18, 36 W Nominal current 1x18W 85mA 2x18W 170mA 1x36W 160mA 2x36W 320mA 1x58W 250mA 2x58W 500mA cos p ) 0.96 capacitive; additional compensation not required 1x18W 85 175mA 2x18W170 345mA 1x36W155 330mA 2x36W 310 660mA 6600/5..-...-6... 6600/5..-...-8... Lamp start Cold start Cold start Voltage 220... 240 Vac 120... 277 Vac Voltage 198 264 Vdc 113 294 Vdc DC during switching on Voltage 176 264 Vdc 113 294 Vdc DC during operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC with 2 lamps with 2 lamps Lamps standard IEC 60081 ANSI C78.81 Lamp power 18, 36, 58 W 17, 32, 40 W Nominal current On opening the diffuser Faulty lamp 1x18W 75mA 2x18W 150mA 1x36W 150mA 2x36W 300mA 1x58W 240mA 2x58W 480mA 1x17W 80 155mA 2x17W 160 305mA 1x32W 135 285mA 2x32W 270 570mA 1x40W 160 360mA 2x40W 325 715mA optional when opening the fastening mechanism of one of the quick fasteners, voltage to ballast will be switched off all-pole; contacts are positively opening, reconnection when cover and quick fasteners are closed. If lamp is faulty, power supply of lamps is switched off automatically by electronic ballast; when using a 2-channel-ECG power is switched off only to the defective lamp. Lighting /3

Technical data Luminous Characteristics Measures for light guidance Luminous intensity distribution Standard Wide beam, reflector painted white. Colour: signal white RAL 9003; prismatic structure for anti-glare in the diffuser sides. Special Additional reflector (easily mounted), broad deep-beam, aluminium anodized and semi-polished. 08258E00 Version 1-lamp, without reflector 1-lamp, with reflector Accuracy class acc. to LitG B21 B31 08257E00 Ambient conditions Ambient temperature 08259E00 Version 2-lamp, without reflector 2-lamp, with reflector Accuracy class acc. to LitG B21 B31 without trough wiring with trough wiring T a T s max T a T s max 220.. 240 V (IEC) 6600/52.-...-0... - 25... + 55 C + 80 C - 25... + 55 C + 80 C 6600/54.-...-0... - 25... + 55 C + 80 C - 25... + 55 C + 80 C 6600/56.-...-0... - 25... + 55 C + 80 C - 25... + 55 C + 80 C 110... 240 V (IEC) 6600/52.-...-4... - 25... + 50 C + 95 C - 25... + 45 C + 95 C 6600/54.-...-4... - 25... + 50 C + 95 C - 25... + 45 C + 95 C 220... 240 V (IEC) 6600/52.-...-6... - 25... + 55 C + 70 C - 25... + 55 C + 70 C 6600/54.-...-6... - 25... + 55 C + 70 C - 25... + 55 C + 70 C 6600/56.-...-6... - 25... + 55 C + 75 C - 25... + 55 C + 75 C 120... 277 V (NEC) 6600/53.-...-6... - 25... + 55 C + 85 C 6600/55.-...-6... - 25... + 55 C + 85 C 6600/57.-...-6... - 25... + 55 C + 85 C Mechanical data Degree of protection IP66 (IP64 when using breather 8162) Protection class I (with internal PE connection terminal) Material Enclosure Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Lamp cover Polycarbonate Seal Silicone-gasket foamed into diffuser Quick-acting locks Polyamide, glass fibre reinforced, black / white Assembly parts Polyester resin, glass fibre reinforced, colour white, similar RAL 9010 Cover options Quick fasteners to open with screw-driver; cover hinged for access. 08257E00 /4 Lighting

Technical data Mounting / installation Mounting Cable glands Connection Standard Special 2 x M8 inserts in housing Mounting grooves in housing to accommodate bracket fitting and ceiling rails for variable light installation. Variable mounting distances of light fittings; see dimension drawings 1 x cable gland 8161, M25 x 1.5, cable dia. range: d 7... 17 mm 2 x stopping plugs 8290, M25 x 1.5 Entry parts in moulded plastic (8161 / 8290): M20 Metal glands: M20; M25; Metal cable gland earthing via metal adapter plates Spring cage terminal connection cross-section: max. 2 x 2.5 mm 2 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Terminal block with screw terminals connection cross-section: max. 2 x 6 mm 2 (solid) max. 2 x 4 mm 2 (flexible) numbers of terminals: 3 pole (terminal marking: L1 + N + PE) 5 pole (terminal marking: L1 + L2 + L3 + N + PE) Installation notes Looping through of There are 2 M25 x 1.5 cable entries on the connection side for looping through of connection cables cable (entry and exit on one side). Through wiring Fittings can be supplied with internal through-wiring. Entry and exit holes for connection cables are positioned on opposite sides. A through-wiring kit can be fitted after manufacture (see accessories). Terminals: See technical data top Wiring cross-section: 2.5 mm 2 for max. 16 A Monitoring module Function Monitoring and switching module for emergency light systems according to VDE 0108: The module is used for the monitoring of individual lights and for the control of network and safety lights. The module offers the following functions: Control of the light (ON / OFF) and function test Up to 20 addresses can be set for each electric circuit by means of a coding switch The operating mode of the lamp (continuous light, stand-by light or activation by means of a switch) is freely programmable Mixed operation within one circuit is possible Input voltage (Input between L+ and N-) Control input (between L and N) Connected power (output to light) Ambient temperature U N U DC U N P 230 (+ 10 % / - 15 %) V AC, 50 Hz 175... 275 V DC 230 (+ 10 % / - 15 %) V AC, 50 Hz 4... 100 W T a (Module) - 10... + 50 C Dimensions L x W x H = 95 x 40 x 32 mm Lighting /5

Accessories and spare parts Designation Figure Description Art. no. Weight Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white 18 W 1350 Im kg 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Diffuser cover Switch 05329E00 for light fitting 18 W 124890 0.500 for light fitting 36 W 124897 0.860 for light fitting 58 W 124904 0.800 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 Mounting kit for through wiring Reflectors 10809E00 05503E00 05324E00 For later installation into standard-light fitting DV3, tension clamp terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W 124925 0.120 36 W 124927 0.300 58 W 124929 0.300 DV5, tension clamp terminals 5 x 2.5 mm 2, 0.000 max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W 124919 0.300 36 W 124921 0.300 58 W 124923 0.300 DV3, screw terminals 3 x 2.5 mm 2, max. 16 A terminal marking: L1 + N + PE 18 W 124912 0.400 36 W 124915 0.400 58 W 124917 0.400 DV5, screw terminals 5 x 2.5 mm 2, max. 16 A terminal marking: L1 + L2 + L3 + N + PE 18 W 124895 0.400 36 W 124902 0.400 58 W 124909 0.400 for later installation, broad deep beam For 1-lamp light fittings 18 W 117128 0.082 For 1-lamp light fittings 36 W 117137 0.172 For 1-lamp light fittings 58 W 117150 0.218 For 2-lamps light fittings18 W 117098 0.265 For 2-lamps light fittings36 W 117115 0.234 For 2-lamps light fittings 58 W 117145 0.290 /6 Lighting

Accessories and spare parts Designation Figure Description Art. no. Weight kg Adapter plates for earth continuity when using metal glands; 1 x M20 x 1.5 1 piece 115815 0.070 05755E00 1 x M25 x 1.5 1 piece 1 x NPT 1 / 2 1 piece 115818 0.070 115821 0.070 1 x NPT 3 / 4 1 piece 115824 0.070 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 115826 0.060 115828 0.060 Lamp-holder 2 x NPT 1 / 2 1 piece 115829 0.060 Lamp holder for two-pin cap lamps G 13 107275 0.008 05888E00 Mounting rail for a variable mounting distance of 1 pair 124894 0.210 05895E00 Mounting clamp bracket Mounting bracket mounted on the mounting rail for a variable mounting distance of 1 pair 124901 0.300 05896E00 Ring bolts M8, direct mounting in insert nuts, 1 pair 115736 0.120 Wall-mounting bracket Ceiling mounting bracket 05378E00 05460E00 to mount the lamps as side-entry lamps using a tube with a length of 1300 mm, d 42 mm (for pipe clamp R 1 1 / 2 ) 109281 6.000 for ceiling suspension of the lamp, 1 pair 124908 0.230 Pipe clamps 05897E00 with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 4 (d 42 mm) 124913 1.140 Mounting set,,grid cable rack 09402E00 R 1 1 / 2 (d 48 mm) 124891 1.160 R 2 (d 60 mm) 124898 1.300 for grid cable racks, with a cable diameter of 6 mm; 124905 1.560 with mounting rail for a variable mounting distance; Material: stainless steel Ceiling and wallmounting bracket 04361E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 05898E00 1 pair 124910 1.150 Lighting /7

Accessories and spare parts Designation Figure Description Art. no. Weight kg Cable gland of moulded material, series 8161 05864E00 8161/5-M20-13 1 piece 138518 0.012 8161/5-M20-13 50 pieces 138454 0.600 Stopping plug 04840E00 8161/5-M25-17 8161/5-M25-17 of moulded material, series 8290 8290/3-M20 1 piece 8290/3-M20 8290/3-M25 x 1,5 8290/3-M25 1 piece 50 pieces 100 pieces 1 pieces 100 pieces 138520 0.020 138456 1.000 143522 0.005 143543 0.500 143524 0.007 143544 0.700 Breathing gland 05703E00 for installation in lights; in moulded material; without counter nut Thread: M25 x 1.5 1 pc Thread: M25 x 1.5 20 pcs 138573 0.010 138576 0.200 /8 Lighting

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Light fittings ECOLUX 6600, 18 W, 36 W, 58 W 04824E00 Dimensions Light fitting 18 W 36 W 58 W L1 700 1310 1610 L2 1) 400 800 800 L3 2) 340... 460 680... 920 795... 1030 1) Fixed mounting distance 2) Variable mounting distance Pipe clamp 04717E00 Mounting set grid cable rack 04822E00 04716E00 04833E00 Ceiling- and wall-mounting bracket Ceiling mounting bracket 04823E00 04715E00 04834E00 Wall mounting bracket for pole-mounting version Ring bolt Mounting clamp bracket Installation accessories We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /9